Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Environ Manage ; 358: 120863, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38615396

RESUMO

This study aims to remove Congo red dye from industrial effluent using economical agriculturally-based nano-biosorbents like magnetic orange peel, peanut shells, and tea waste. The nano-biosorbents were characterized by various analytical techniques like SEM, FT-IR, BET and XRD. The highest adsorption capacity was obtained under the following ideal conditions: pH = 6 (orange peel and peanut shells), pH = 3 (tea waste), and dosages of nano-biosorbents with varying timeframes of 50 min for tea waste and peanut shells and 30 min for orange peel. The study found that tea waste had the highest removal rate of 94% due to its high porosity and responsible functional groups, followed by peanut shells at 83% and orange peel at 68%. The Langmuir isotherm model was found to be the most suitable, with R2 values of 0.99 for tea waste, 0.92 for orange peel, and 0.71 for peanut shells. On the other hand, a pseudo-second-order kinetic model was very feasible, showing an R2 value of 0.99 for tea waste, 0.98 for peanut shells and 0.97 for orange peel. The significance of the current study lies in its practical application, enabling efficient waste management and water purification, thereby preserving a clean and safe environment.


Assuntos
Vermelho Congo , Vermelho Congo/química , Cinética , Adsorção , Agricultura , Poluentes Químicos da Água/química , Resíduos Industriais , Espectroscopia de Infravermelho com Transformada de Fourier , Chá/química , Arachis/química , Concentração de Íons de Hidrogênio
2.
Molecules ; 24(16)2019 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-31394856

RESUMO

Paper-based microfluidic devices have advanced significantly in recent years as they are affordable, automated with capillary action, portable, and biodegradable diagnostic platforms for a variety of health, environmental, and food quality applications. In terms of commercialization, however, paper-based microfluidics still have to overcome significant challenges to become an authentic point-of-care testing format with the advanced capabilities of analyte purification, multiplex analysis, quantification, and detection with high sensitivity and selectivity. Moreover, fluid flow manipulation for multistep integration, which involves valving and flow velocity control, is also a critical parameter to achieve high-performance devices. Considering these limitations, the aim of this review is to (i) comprehensively analyze the fabrication techniques of microfluidic paper-based analytical devices, (ii) provide a theoretical background and various methods for fluid flow manipulation, and iii) highlight the recent detection techniques developed for various applications, including their advantages and disadvantages.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Microfluídica/instrumentação , Microfluídica/métodos , Algoritmos , Desenho de Equipamento , Humanos , Modelos Teóricos , Papel
3.
RSC Adv ; 14(15): 10331-10347, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38549795

RESUMO

Vitamins are crucial micronutrients found in limited quantities in food, living organisms, and soil. Since most vitamins are not produced within the human body, a lack of these essential nutrients can result in various physiological disorders. Analyzing vitamins typically involves costly, time-consuming methods, requiring skilled personnel, automated equipment, and dedicated laboratory setups. The pressing need is for the development of efficient, portable, and user-friendly detection techniques that are cost-effective, addressing the challenges associated with traditional analytical approaches. In recent years, electrochemical sensors and electrochemical microfluidic devices have garnered prominence owing to their remarkable sensitivity, quick analysis, cost-effectiveness, and facile fabrication procedures. Electrochemical sensing and microfluidics are two distinct fields that are often integrated to create powerful and versatile sensing devices. The connection between them leverages the advantages of both fields to create highly efficient, miniaturized, and portable analytical systems. This interdisciplinary approach has led to the development of innovative devices with broad applications in various scientific, medical, and environmental domains. This review begins by outlining the importance of vitamins in human nutrition and health and emphasizing the need for precise and reliable sensing techniques. Owing to the limited literature available on electrochemical detection of vitamin B complexes, this review offers an in-depth analysis of modern electrochemical sensing of water-soluble vitamins, focusing on B1, B2, B6, B9, and B12. The challenges faced by researchers are addressed, including selectivity, sensitivity, interference, matrix effects, and calibration, while also exploring promising prospects such as nanomaterial integration, miniaturization, microfluidics-based IoTs, and innovative sensor designs.

4.
Food Chem ; 455: 139869, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38850977

RESUMO

Although citric acid (CA) has antioxidant, antibacterial, and acidulating properties, chronic ingestion of CA can cause urolithiasis, hypocalcemia, and duodenal cancer, emphasizing the need for early detection. There are very few documented electrochemical-based sensing methods for CA detection due to the challenging behavior of electrode fouling caused by reactive oxidation products. In this study, a novel, non-enzymatic, and economical electrochemical sensor based on cobalt oxide nanoparticles (CoOxNPs) is successfully reported for detection CA. The CoOxNPs were synthesized through a simple thermal decomposition method and characterized by SEM, FT-IR, EDX, and XRD techniques. The proposed sensing platform was optimized by various parameters, including pH (7.0), time (15 min), and concentration of nanoparticles (100 mM) etc. In a linear range of 0.05-2500 µM, a low detection limit (LOD) of 0.13 µM was achieved. Theoretical calculations (ΔRT), confirmed hydrogen bonding and electrostatic interactions between CoOxNPs and CA. The detection method exhibited high selectivity in real media like food and biological samples, with good recovery values when compared favorably to the HPLC method. To facilitate effective on-site investigation, such a sensing platform can be assembled into a portable device.


Assuntos
Ácido Cítrico , Cobalto , Técnicas Eletroquímicas , Óxidos , Cobalto/química , Técnicas Eletroquímicas/instrumentação , Óxidos/química , Ácido Cítrico/química , Nanopartículas Metálicas/química , Limite de Detecção , Nanopartículas/química
5.
Sci Prog ; 107(1): 368504241235508, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38426804

RESUMO

This research explores the flow penetration in porous media by virtue of capillary action and geometric control of the liquid imbibition rate in microfluidic paper-based analytical devices (µPADs) having applications in food quality management, medical diagnostics, and environmental monitoring. We examine changes in flow resistance and membrane geometry, aiming to understand factors influencing capillary penetration rates for various practical applications. We conducted experiments and simulations using lateral porous membranes and altered the flow resistance by changing the liquids or the paper channel geometry by adding cavities. From experiments, it was revealed that by creating a circular cavity in the paper channel, the penetration rate was sufficiently altered. Moreover, increasing the cavity size and type of liquid (w.r.t. viscosity) also caused a decrease in the flow rate. Imbibition rates were also influenced by the position of the cavities in the paper channel. The maximum delay for water was almost 2 times with a 16 mm circular cavity located at 3 cm from strip bottom edge. Overall, we attained a maximum delay in the case of castor oil which was almost 85 times slower than water and 3.7 times slower than olive oil. A good agreement was observed with CFD analysis. We believe that this research would help in developing advance techniques to enhance the flow control strategies in µPADs and indicators.

6.
ACS Omega ; 7(15): 12937-12946, 2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35474789

RESUMO

Multilayer CdZnS (CZS) thin film was deposited on soda lime glass substrates. After deposition, the films were vacuum and air annealed at 100 °C, 200 °C, 300 and 400 °C for 1 h. Effects of vacuum and air annealing on structural, morphological, optical, and electrical properties of multilayer CZS films with increasing annealing temperature (IAT) were studied. The structural analysis revealed that the films were polycrystalline with hexagonal structure having a prominent/intensive peak along the (002) plane at 300 and 400 °C. The crystallite size of nanoparticles increased from 18.4 to 20.5 nm under air annealing and from 18.4 to 26.9 nm under vacuum annealing, showing the significance of annealing on nanoparticle grain growth. According to morphological analysis, the multilayer technique provides homogeneous film distribution over the substrate. The transmittance graphs of films revealed that it increased up to 92% in the visible and NIR regions under vacuum annealing and up to 52% under air annealing. Vacuum annealing enhanced the band gap energies more significantly than air annealing. The electrical resistivity increased with IAT, showing that structural, morphological, optical, and electrical properties of the multilayer thin films of CZS were strongly dependent on vacuum and air annealing.

7.
Biomicrofluidics ; 16(6): 064106, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36536792

RESUMO

Paper has attracted significant attention recently as a microfluidic component and platform, especially in passive pumping devices due to its porous and uniform absorbing nature. Many investigations on 1D and 2D fluid flows were carried out. However, no experimental work has been reported on the three-dimensional effect in porous geometry to improve pumping characteristics in microchannels. Therefore, in this study, the fluid flow in 3D paper-based passive pumps was investigated in microchannels using cylindrical pumps. The effect of pump diameter, porosity, and programmability was investigated to achieve desired flow variations. The results indicated that the flow rate of water increased with an increase in the diameter and porosity of paper pumps. Maximum flow rates achieved for 14 mm diameter pumps of 0.5 and 0.7 porosities were 5.29 mm3/s (317.4 µl/min) and 6.97 mm3/s (418.2 µl/min), respectively. The total volume of fluid imbibition ranged between 266 and 567 µl for 8 and 14 mm diameter pumps, respectively. Moreover, 3D passive pumps can transport larger volumes of liquid with an improved flow rate, programmability, and control, in addition to being inexpensive and simple to design and fabricate. Most importantly, a single 3D paper pump showed an increasing, decreasing, and constant flow rate all in a single microchannel. With these benefits, the passive pumps can further improve the pumping characteristics of microfluidic platforms enabling a cost effective and programmable point-of-care diagnostic device.

8.
J Am Heart Assoc ; 10(8): e019467, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33834845

RESUMO

Background Major bleeding after acute coronary syndrome predicts a poor outcome but is challenging to define. The choice of antiplatelet influences bleeding risk. Methods and Results Major bleeding, subsequent myocardial infarction (MI), and all-cause mortality to 1 year were compared in consecutive patients with acute coronary syndrome treated with clopidogrel (n=2491 between 2011 and 2013) and ticagrelor (n=2625 between 2012 and 2015) in 5 English hospitals. Clinical outcomes were identified from national hospital episode statistics. Bleeding and MI events were independently adjudicated by 2 experienced clinicians, blinded to drug, sequence, and year. Bleeding events were categorized using Bleeding Academic Research Consortium 3 to 5 and PLATO (Platelet Inhibition and Patient Outcomes) criteria and MI by the Third Universal Definition. Multivariable regression analysis was used to adjust outcomes for case mix. The median age was 68 years and 34% were women. 39% underwent percutaneous coronary intervention and 13% coronary artery bypass graft surgery. Clinical outcome data were 100% complete for bleeding and 99.7% for MI. No statistically significant difference was seen in crude or adjusted major bleeding for ticagrelor compared with clopidogrel (Bleeding Academic Research Consortium 3-5, hazard ratio [HR], 1.23; 95% CI, 0.90-1.68; P=0.2, PLATO major adjusted HR, 1.30; 95% CI, 0.98-1.74; P=0.07) except in the non-coronary artery bypass graft cohort (n=4464), where bleeding was more frequent with ticagrelor (Bleeding Academic Research Consortium 3-5, adjusted HR, 1.58; 95% CI, 1.09-2.31; P=0.017; and PLATO major HR, 1.67; 95% CI, 1.18-2.37; P=0.004). There was no difference in crude or adjusted subsequent MI (adjusted HR, 1.20; 95% CI, 0.87-1.64; P=0.27). Crude mortality was higher in the clopidogrel group but not after adjustment, using either Cox proportional hazards or propensity matched population (HR, 0.90; 95% CI, 0.76-1.10; P=0.21) as was the case for stroke (HR, 0.82; 95% CI, 0.52-1.32; P=0.42). Conclusions This observational study indicates that the apparent benefit of ticagrelor demonstrated in a clinical trial population may not be observed in the broader population encountered in clinical practice. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02484924.


Assuntos
Síndrome Coronariana Aguda/terapia , Clopidogrel/efeitos adversos , Hemorragia/epidemiologia , Ticagrelor/efeitos adversos , Síndrome Coronariana Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Causas de Morte/tendências , Clopidogrel/uso terapêutico , Inglaterra/epidemiologia , Feminino , Hemorragia/induzido quimicamente , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Taxa de Sobrevida/tendências , Ticagrelor/uso terapêutico
9.
J Hazard Mater ; 365: 261-269, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30447633

RESUMO

A region suffering from an attack of a nerve agent requires not only a highly sorptive material but also a fast-acting catalyst to decontaminate the lethal chemical present. The product should be capable of high sorptive capacity, selectivity and quick response time to neutralize the long lasting harmful effects of nerve agents. Herein, we have utilized organophosphorus hydrolase (OPH) as a non-toxic bio-catalytic material held in with the supporting matrix of poly-ß-cyclodextrin (PCD) as a novel sorptive reinforced self-decontaminating material against organophosphate intoxication. OPH coated PCD (OPH-PCD) will not only be providing support for holding enzyme but also would be adsorbing methyl paraoxon (MPO) used as a simulant, in a host-guest inclusion complex formation. Sorption trend for PCD revealed preference towards the more hydrophobic MPO against para-nitrophenol (pNP). The results show sorption capacity of 1.26 mg/g of 100 µM MPO with PCD which was 1.7 times higher compared to pNP. The reaction rate with immobilized OPH-PCD was found to be 23% less compared to free enzyme. With the help of OPH-PCD, continuous hydrolysis (100%) of MPO into pNP was observed for a period of 24 h through packed bed reactor with good reproducibility and stability of enzyme. The long-term stability also confirmed its stable nature for the investigation period of 4 days where it maintained activity. Combined with its fast and reactive nature, the resulting self-decontaminating regenerating material provides a promising strategy for the neutralization of nerve agents and preserving the environment.


Assuntos
Arildialquilfosfatase/química , Substâncias para a Guerra Química/química , Inibidores da Colinesterase/química , Descontaminação/métodos , Enzimas Imobilizadas/química , Inseticidas/química , Paraoxon/análogos & derivados , beta-Ciclodextrinas/química , Adsorção , Biocatálise , Concentração de Íons de Hidrogênio , Paraoxon/química
10.
Int J Cardiol ; 102(1): 1-7, 2005 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-15939093

RESUMO

Spontaneous coronary artery spasm is an important cause of morbidity both in patients with coronary artery disease and in those with variant angina. A number of pharmacological agents have been identified which can provoke coronary artery spasm in susceptible patients. The role of provocation testing in the clinical diagnosis of coronary spasm is controversial. This is reflected by variations in the clinical use of provocation testing between specialist cardiac centres. Provocation testing appears to be a sensitive method of identifying patients with variant angina and active disease but such patients can often be diagnosed clinically. The specificity is less clear. There is little evidence that altering patient therapy on the basis of a positive test modifies prognosis. There may be a role for provocation testing in rare patients with refractory disease to identify a target site for coronary stenting. A more widespread use of these tests in patients with undiagnosed chest pain syndromes would not currently be recommended.


Assuntos
Vasoespasmo Coronário/diagnóstico , Teste de Esforço , Vasoconstrição/efeitos dos fármacos , Vasodilatadores , Vasoespasmo Coronário/fisiopatologia , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/fisiopatologia , Diagnóstico Diferencial , Humanos
12.
Cardiol Res ; 5(6): 195-197, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28352454

RESUMO

Although most of the patients presenting with ischemic heart disease have chest pains, there are other rare presenting symptoms like cardiac cephalgia. In this report, we present a case of acute coronary syndrome with an only presentation of exertional headache. It was postulated as acute presentation of coronary artery disease, due to previous history of similar presentation associated with some chest pains with previous left coronary artery stenting. We present an unusual case with cardiac cephalgia in a young patient under the age of 50 which was not reported at that age before. There are four suggested mechanisms for this cardiac presentation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA