Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Intern Med ; 175(7): JC77, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35785544

RESUMO

SOURCE CITATION: Bahnson TD, Giczewska A, Mark DB, et al. Association between age and outcomes of catheter ablation versus medical therapy for atrial fibrillation: results from the CABANA trial. Circulation. 2022;145:796-804. 34933570.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Humanos , Resultado do Tratamento
2.
JACC Clin Electrophysiol ; 10(9): 2088-2096, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39001765

RESUMO

BACKGROUND: There are no randomized data to inform the extent to which transvenous cardiac leads cause tricuspid regurgitation (TR). OBJECTIVES: This study sought to determine the effect of a transvenous implantable cardioverter-defibrillator (TV-ICD) on TR severity, and secondarily, on right ventricular (RV) size and function. METHODS: We evaluated TR severity before and 6 months after implantable cardioverter-defibrillator insertion in a post hoc analysis of adults randomized to receive a transvenous (n = 252) or subcutaneous implantable cardioverter-defibrillator (S-ICD) (n = 251) device. TR and RV size and systolic function were assessed by echocardiographic images analyzed in a core laboratory. RESULTS: At baseline, at least mild TR was present in 30% of individuals. At 6 months, the proportion of participants with any TR in the TV-ICD group was 42% vs 19% in the S-ICD group (P < 0.001). The proportion with moderate or severe TR was 7% in the TV-ICD group vs 2% in the S-ICD group (P = 0.021). At 6 months, the OR of at least 1 grade worsening of TR in the TV-ICD group as compared with the S-ICD group was 7.2 (95% CI: 3.3-15.8; P < 0.001). There were no differences between groups with respect to RV size or systolic function. CONCLUSIONS: Six months following TV-ICD insertion, there was a 7-fold increase in the risk of at least 1 grade worsening of TR, with 7% of individuals having TR that was moderate or severe. There was no detectable difference in RV size or function; however, longer follow-up is needed.


Assuntos
Desfibriladores Implantáveis , Ventrículos do Coração , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Desfibriladores Implantáveis/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Idoso , Valva Tricúspide/diagnóstico por imagem , Ecocardiografia , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA