RESUMO
BACKGROUND: To quantify the volumetric aortic remodeling of patients with acute type B aortic dissection treated with the stent-assisted balloon-induced intimal disruption and relamination (STABILISE) technique. METHODS: All patients with acute type B aortic dissection operated with the STABILISE technique between 2014 and 2017 with preoperative, postoperative, and >12 months (follow-up) computed tomography scans were included in this study. True lumen and total aortic volume were accurately assessed in the thoracic and abdominal portions with a semiautomatic three-dimensional tool. Associations with long-term adverse events were estimated. RESULTS: Seventeen patients were measured at preoperative, postoperative, and a mean follow-up of 19 ± 8 months. The false lumen to total volume ratio decreased on average from 63% to 18% after STABILISE (P < 0.001) and remained around 12% at follow-up. These remodeling was more pronounced in the thoracic aorta (7%) than in the abdominal aorta (28%). The trend in aortic size growth was stronger for volumes than for maximum areas or diameters (P < 0.001, P < 0.05, and P < 0.05, respectively). Adverse events were identified in 4 patients during a long-term follow-up of 76 ± 18 months. The only aortic size variable assessed preoperatively that was associated with undesirable events was the total volume of the abdominal aorta (P < 0.05). CONCLUSIONS: A volumetric analysis of dissected aortic size after the STABILISE procedure allowed accurate quantification of mid-term aortic remodeling and helped to identify the abdominal aortic volume as a preoperative variable associated with undesirable long-term events.
RESUMO
BACKGROUD: The learning curve and midterm results of aortoiliac occlusive disease (AIOD) revascularization by robot-assisted laparoscopic (RAL) surgery may be known. METHODS: A prospective single-center study was conducted in the vascular surgery department of Georges Pompidou European Hospital (Paris, France). Patients with AIOD treated by RAL from February 2014 to February 2019 were included. Demographic characteristics, past medical history, Trans-Atlantic Inter-Society Consensus (TASC) lesions classifications, mortality, primary and secondary patency, as well as complication rates were collected. Safety was analyzed by the cumulative sum control chart method with a conversion rate of 10%, operative time by cumulative average-time model, and primary and secondary patency by the Kaplan-Meier method. RESULTS: Seventy patients were included, 18 (25.7%) with TASC C lesions and 52 (74.3%) with TASC D lesions. Before discharge, 14 (24.3%) patients had surgical complications. Among them, 10 (14.3%) required at least one reintervention. One (1.4%) patient died during the hospitalization. The learning curve in terms of safety (conversion rate) was 13 cases with an operating time of 220 minutes after 35 patients. During follow-up (median 37 months [21; 49]), 63 patients (91.3%) improved their symptoms, 53 (76.8%) became asymptomatic, and 3 graft limb occlusions occurred. The primary patency at 12, 24, 36, and 48 months was 94%, 92%, 92%, and 92%, respectively, while the secondary patency for the same intervals was 100%, 98.1%, 98.1%, and 98.1%, respectively. CONCLUSIONS: Robotic surgery in AIOD revascularization seems safe and effective; allowing to treat patients with few comorbidities and severe lesions, in a dedicated center experienced in RAL, with excellent patency. Prospective clinical trials should be performed to confirm safety.
Assuntos
Doenças da Aorta , Arteriopatias Oclusivas , Artéria Ilíaca , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos , Grau de Desobstrução Vascular , Humanos , Masculino , Feminino , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Artéria Ilíaca/cirurgia , Artéria Ilíaca/fisiopatologia , Artéria Ilíaca/diagnóstico por imagem , Idoso , Doenças da Aorta/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Doenças da Aorta/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Pessoa de Meia-Idade , Arteriopatias Oclusivas/cirurgia , Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/mortalidade , Estudos Prospectivos , Fatores de Risco , Complicações Pós-Operatórias/etiologia , Laparoscopia/efeitos adversos , Paris , Competência Clínica , Duração da CirurgiaRESUMO
BACKGROUND: The management of residual aortic dissection after initial type A repair with the Frozen elephant trunk technique remains mostly unexplored. This work aimed to evaluate endovascular second-stage surgery for patients with residual aortic dissection. METHODS: A retrospective analysis of consecutive patients that underwent Type A aortic repair with Frozen elephant trunk, followed by a second-stage endovascular procedure was done from March 2016 to December 2021. The primary outcome was aortic-related adverse events or mortality, and secondary outcomes were aortic remodeling and perioperative complications. Remodeling was assessed by comparing the difference in ratios for true lumen/total aortic diameters on pre-operative and follow-up scans. RESULTS: Thirty-four patients underwent second-stage surgery after Type A repair during the study period (7 thoracic endovascular aortic repair extensions, 1 STABLE/PETTICOAT, and 26 STABILISE). Median follow-up was 23 months (range 2-66 months). There were no perioperative deaths or major complications and 1 reoperation for left subclavian re-embolization. At the last follow-up, there was no aortic-related mortality. There were 5 aortic-related adverse events, including another subclavian re-embolization and a preplanned open conversion. Risk factors were connective tissue disorders (P = 0.01) and aortic aneurysms >55 mm (P = 0.03). Distal remodeling reached statistical significance in all segments (P < 0.01) and was greater for patients treated with the STABILISE technique when compared to extended thoracic endovascular aortic repair (P = 0.01). CONCLUSIONS: Second-stage endovascular management of residual aortic dissection after initial Frozen elephant trunk repair showed excellent perioperative and good midterm outcomes and induced significant remodeling of the entire aorta in most cases, particularly with the STABILISE procedure.
Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Estudos Retrospectivos , Resultado do Tratamento , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Prótese Vascular , StentsRESUMO
OBJECTIVE: A proximal scallop design allows aortic arch repair without complex endovascular manipulation in the aortic arch. The aim was to assess the safety and efficacy at one year of the Relay proximal scallop stent graft. METHODS: A prospective multicentre study evaluated consecutive patients treated with the Relay proximal scallop stent graft in 10 French aortic centres. All consecutive patients eligible for elective thoracic endovascular repair with proximal scallop in the 10 participating centres between January 2015 and July 2018 were included. Primary endpoints were 30 day mortality, stroke, and spinal cord ischaemia (SCI) rates. Outcomes including safety and efficacy, technical and clinical success, all cause death, neurological events, vessel patency, and device specific complications were analysed. Survival and survival without severe complications were estimated using Kaplan-Meier estimates. RESULTS: Ten aortic centres treated 40 patients for thoracic aortic aneurysm (45%), penetrating atherosclerotic aneurysm (30%), and dissection (25%). Half of the procedures (50%) targeted zone 0 of the aortic arch (zone 0 in 17.5% and zones 0/1 in 32.5%), 37.5% targeted zone 2 (35% zone 2 alone; 2.5% zones 1/2), and 15% targeted zone 1 (12.5% zone 1 alone). Median follow up was one year. Thirty day mortality, stroke, and SCI rates were 10%, 5%, and 0% respectively. Primary technical success was 95%. Type Ia, Ib, and III endoleaks rates were 5.4%, 0%, and 0% respectively at one month. The overall mortality rate at one year was 17.5%. Aneurysm expansion was > 5 mm in one case at one year associated with type Ia endoleak (3%). There was no supra-aortic trunk thrombosis, one (2%) graft kink, and no migration. CONCLUSION: One year outcomes showed that the Relay proximal scallop stent graft is an acceptable answer to thoracic aortic disease to deal with short proximal landing zones.
Assuntos
Aneurisma , Aneurisma da Aorta Torácica , Doenças da Aorta , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Stents/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/cirurgia , Doenças da Aorta/complicações , Endoleak/etiologia , Endoleak/cirurgia , Acidente Vascular Cerebral/cirurgia , Estudos RetrospectivosRESUMO
BACKGROUND: For same-day discharge lower extremity arterial disease (LEAD) endovascular procedures, femoral manual compression could be an alternative to arterial closure devices. The aim of this study was to assess the security and efficacy of same-day discharge after manual compression in patients treated for LEAD endovascular revascularization with 5F sheath. METHODS: FREEDOM OP was a national multicenter, prospective, single arm study. Patients with symptomatic LEAD (Rutherford 2-5) and eligible for same-day discharge were included. The primary endpoint was the total in-hospital admission rate, which includes overnight surveillance and rehospitalization rate at 1 month. RESULTS: Between September 2017 and August 2019, 114 patients were included. The mean age of the patients was 66 ± 10 years and most of them were claudicant (103; 94%). Mainly femoropopliteal lesions were treated (178; 70%) and the technical success was 97%. One hundred forty-two 5F stents and fifty one 5F drug coated balloon were delivered. The mean manual compression duration was 13 ± 4 min. Major access-related complications rate was 4.5%. Total in-hospital admission rate was 11%. Seven patients had overnight surveillance and 5 were rehospitalized (2 for the target lesion). No rehospitalisation was carried out within 24 hr after discharge. No major cardiovascular event, including death, was observed. The patients were significantly improved in term of clinical status (P < 0.0001) and hemodynamic (P < 0.0001) in comparison to baseline. CONCLUSION: FREEDOM OP showed that manual compression is feasible and safe for same-day discharge after LEAD revascularization with 5F sheath femoral approach.
Assuntos
Arteriopatias Oclusivas/cirurgia , Procedimentos Endovasculares , Artéria Femoral , Alta do Paciente/estatística & dados numéricos , Doenças Vasculares Periféricas/cirurgia , Idoso , Procedimentos Endovasculares/instrumentação , Feminino , França , Hospitalização/estatística & dados numéricos , Humanos , Perna (Membro)/irrigação sanguínea , Masculino , Pressão , Estudos Prospectivos , PunçõesRESUMO
BACKGROUND: COVID-19 infection is associated not only with venous thromboses but also with arterial thromboses (COV-ATs) in relation with an endothelial dysfunction, a coagulopathy and rhythm disorders. The incidence, the topography, and the prognosis of COV-ATs remain poorly known. The objective of this study was to report the overall experience of the Greater Paris University Hospitals (Assistance Publique - Hopitaux de Paris, AP-HP) during the first pandemic wave of COVID-19 infection. METHODS: After approval by the ethics committee, a study using the AP-HP clinical data warehouse was carried out between March and May 2020. Overall, 124,609 patients had a polymerase chain reaction for COVID-19 in our hospitals, of which 25,345 were positive. From 20,710 exploitable stays, patients tested positive for COVID who presented an episode of acute COV-AT (except coronary and intracranial arteries) were selected on the basis of the French medical classification for clinical procedures codes. The data are presented as absolute values with percentages and/or means with standard deviation. RESULTS: Over the studied period, 60 patients (aged 71±14 years, 42 men) presented a COV-AT at the time of their hospitalization, an incidence of 0.2%. The arterial complication occurred 3±7 days after the COVID infection and was inaugural in 30% of the cases (n = 18). The sites of COV-AT were the lower extremities (n = 35%, 58%), the abdominal aorta (n = 10%, 17%), the thoracic aorta (n = 7%, 12%), the upper limbs (n = 7%, 12%), the cerebral arteries (n = 7%, 12%), the digestive arteries (n = 6%, 10%), the renal arteries (n = 2%, 3%), and the ophthalmic artery (n = 1%, 2%). Multiple COV-ATs were observed in 13 patients (22%). At the time of diagnosis, 20 (33%) patients were in intensive care, including six (10%) patients who were intubated. On computed tomography angiography, COVID lesions were classified as moderate and severe in 25 (42%) and 21 (35%) cases, respectively. Revascularization was attempted in 27 patients (45%), by open surgery in 16 cases, using endovascular techniques in 8 cases and with a hybrid approach in three cases. Six patients (22%) required reinterventions. The duration of hospitalization was 12±9 days. Early mortality (in-hospital or at 30 days) was 30% (n = 18). Nine (15%) patients presented severe nonlethal ischemic complications. CONCLUSIONS: Arterial involvement is rare during COVID-19 infection. The aorta and the arteries of the limbs are the privileged sites. The morbi-mortality of these patients is high. Future studies will have to determine if the systematization of anticoagulation therapy decreases the incidence and the severity of the condition.
Assuntos
COVID-19 , Trombose , Masculino , Humanos , SARS-CoV-2 , Resultado do Tratamento , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/terapia , ArtériasRESUMO
OBJECTIVE: Carotid plaque vulnerability assessment could guide the decision to perform endarterectomy. Ultrafast ultrasound imaging (UF) can evaluate local flow velocities over an entire 2D image, allowing measurement of the wall shear stress (WSS). We aimed at evaluating the feasibility of WSS measurement in a prospective series of patients with carotid stenosis. METHODS: UF acquisitions, performed with a linear probe, had an effective frame rate of 5000âHz. The flow velocity was imaged over the entire plaque area. WSS was computed with the vector field speed using the formula: with the blood velocity and µ, the blood viscosity. The WSS measurement method was validated using a calibrated phantom. In vivo, WSS was analyzed in 5 areas of the carotid wall: common carotid artery, plaque ascent, plaque peak, plaque descent, internal carotid artery. RESULTS: Good correlation was found between in vitro measurement and the theoretical WSS values (R2â=â0.95; pâ<â0.001). 33 patients were prospectively evaluated, with a median carotid stenosis degree of 80â% [75-85]. The maximum WSS value over the cardiac cycle follows the shape of the plaque with an increase during the ascent, reaching its maximum value of 3.25âPa [2.26-4.38] at the peak of the plaque, and a decrease after passing of the peak (0.93âPa [0.80-1.19]) lower than the WSS values in the non-stenotic areas (1.47âPa [1.12-1.77] for the common carotid artery). CONCLUSION: UF allowed local and direct evaluation of the plaque's WSS, thus better characterizing local hemodynamics to identify areas of vulnerability. KEY POINTS: · Ultrafast vector Doppler allows calculation of the wall shear stress (WSS) by measuring velocity vectors over the entire 2D image.. · The setup to measure the WSS has been validated in vitro on a linear flow phantom by comparing measurements to in silico calculations.. · Applying this method to carotid plaque allows us to better describe the hemodynamic constraints that apply along the entire length of the plaque..
Assuntos
Estenose das Carótidas , Placa Aterosclerótica , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Estudos Prospectivos , Estresse MecânicoRESUMO
OBJECTIVE: The chimney technique (ChEVAR) allows for proximal landing zone extension for endovascular repair of complex aortic aneurysms. The aim of the present study was to assess ChEVAR national outcomes in French university hospital centres. METHODS: All centres were contacted and entered data into a computerised online database on a voluntary basis. Clinical and radiological data were collected on all consecutive ChEVAR patients operated on in 14 centres between 2008 and 2016. Patients were deemed unfit for open repair. Factors associated with early (30 day or in hospital) mortality and type 1 endoleak (Type I EL) were calculated using multivariable analysis. RESULTS: In total, 201 patients with 343 target vessels were treated. There were 94 juxtarenal (46.8%), 67 pararenal (33.3%), 10 Crawford type IV thoraco-abdominal (5%) aneurysms, and 30 (15.1%) proximal failures of prior repairs. The pre-operative diameter was 66.8 ± 16.7 mm and 28 (13.9%) ChEVAR were performed as an emergency, including six (2.9%) ruptures. There were 23 (11.7%) unplanned intra-operative procedures, mainly related to access issues. The rate of early deaths was 11.4% (n = 23). The elective mortality rate was 9.8% (n = 17). Nine patients (4.5%) presented with a stroke. The rate of early proximal Type I EL was 11.9%. Survival was 84.6%, 79.4%, 73.9%, 71.1% at 6, 12, 18, and 24 months, respectively. The primary patency of chimney stents was 97.4%, 96.7%, 95.2%, and 93.3% at 6, 12, 18, and 24 months, respectively. Performing unplanned intra-operative procedures (OR 3.7, 95% CI 1.3-10.9) was identified as the only independent predictor of post-operative death. A ChEVAR for juxtarenal aneurysm was independently associated with fewer post-operative Type I ELs (OR 0.17, 95% CI 0.05-0.58). CONCLUSION: In this large national ChEVAR series, early results were concerning. The reasons may lie in heterogeneous practices between centres and ChEVAR use outside of current recommendations regarding oversizing rates, endograft types, and sealing zones. Future research should focus on improvements in pre-operative planning and intra-operative technical aspects.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , França , Hospitais Universitários , Humanos , Masculino , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: The purpose of this study was to describe the use of the OUTBACK catheter to overcome aortic reentry issues in acute mesenteric ischemia (AMI) treated by retrograde open mesenteric stenting (ROMS). TECHNIQUE: The technique is demonstrated in two female patients presenting with late AMI related to flush occlusion of the superior mesenteric artery (SMA). In such cases of thrombotic AMI with clear preoperative evidence of intestinal necrosis, ROMS is the first-line revascularization technique in our intestinal stroke center. Following an open approach of the SMA through laparotomy, the SMA was punctured in a retrograde fashion. Retrograde mesenteric subintimal recanalization was initiated. In case of aortic reentry issue, the OUTBACK Elite (Cordis, Hialeah, Fl) catheter was advanced through the occlusion over a 0.014 guidewire. The aortic reentry was created by puncture of the aortic wall with the OUTBACK needle, positioned in the desired position. After low-profile balloon angioplasty of the reentry site and 0.035 guidewire exchange, ROMS was performed using balloon-expandable covered stent. CONCLUSIONS: The OUTBACK catheter appears to be a safe and effective tool to overcome aortic reentry issues in ROMS. This technical tip might therefore increase the technical success rate of challenging ROMS and decrease the need for bailout bypass in the septic context of AMI.
Assuntos
Angioplastia com Balão/instrumentação , Artéria Mesentérica Superior , Isquemia Mesentérica/terapia , Oclusão Vascular Mesentérica/terapia , Stents , Dispositivos de Acesso Vascular , Idoso , Angioplastia com Balão/efeitos adversos , Feminino , Humanos , Artéria Mesentérica Superior/diagnóstico por imagem , Artéria Mesentérica Superior/fisiopatologia , Isquemia Mesentérica/diagnóstico por imagem , Isquemia Mesentérica/fisiopatologia , Oclusão Vascular Mesentérica/diagnóstico por imagem , Oclusão Vascular Mesentérica/fisiopatologia , Desenho de Prótese , Circulação Esplâncnica , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
BACKGROUND: Common femoral artery (CFA) stenting appears as a promising alternative treatment to the open surgery for de novo CFA stenosis. The stenting of lesions just located at the CFA is simple, whereas stenting of CFA bifurcation lesions is more complex, and outcomes are still matter of debate. The aim of this study was to describe and to compare clinical outcomes of techniques used to treat simple over complex lesions for the stenting of CFA lesions. MATERIALS/METHODS: From the French randomized controlled trial, TECCO, a total of 54 patients underwent stenting intervention and were enrolled in this study. Patients were excluded if they had CFA thrombosis, restenosis, and nonatheromatous lesions. Patients were classified by simple and complex lesions based on the type of lesion. The primary end point was the primary sustained clinical improvement. RESULTS: Eighteen patients were included in the simple lesion group, and 36 patients, in the complex lesion group. Baseline characteristics of patients were comparable between the 2 groups. The technical success was 100% in the simple lesion group and 91.7% in the complex lesion group. There was no significant difference between the 2 groups, regarding the primary sustained clinical improvement. The primary patency rates at 24 months for simple and complex lesion groups were 86.3% and 79%, respectively (P = 0.66). Freedom from target lesion revascularization was of 93.3% and 82% in the simple and complex lesion group, respectively (P = 0.34). CONCLUSIONS: The stenting technique for CFA bifurcation lesions is a safe and effective technique. More trials with a large number of patients are needed to define the optimal stenting technique.
Assuntos
Procedimentos Endovasculares/instrumentação , Artéria Femoral , Doença Arterial Periférica/terapia , Stents , Idoso , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , França , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
PURPOSE: The growth phases of medically treated abdominal aortic aneurysms (AAA) are frequently associated with an 18F-fluorodesoxyglucose positron emission tomography (FDG-PET) pattern involving low baseline and subsequent higher FDG uptake. However, the FDG-PET patterns associated with the endovascular aneurysm repair (EVAR) of larger AAA are presently unknown. This study aimed to investigate the relationship between serial AAA FDG uptake measurements, obtained before EVAR and 1 and 6 months post-intervention and subsequent sac shrinkage at 6 months, a well-recognized indicator of successful repair. METHODS: Thirty-three AAA patients referred for EVAR (maximal diameter: 55.4 ± 6.0 mm, total volume: 205.7 ± 63.0 mL) underwent FDG-PET/computed tomography (CT) before EVAR and at 1 and 6 months thereafter, with the monitoring of AAA volume and of a maximal standardized FDG uptake [SUVmax] averaged between the axial slices encompassing the AAA. RESULTS: Sac shrinkage was highly variable and could be stratified into three terciles: a first tercile in which shrinkage was absent or very limited (0-29 mL) and a third tercile with pronounced shrinkage (56-165 mL). SUVmax values were relatively low at baseline in the 1st tercile (SUVmax: 1.69 ± 0.33), but markedly increased at 6 months (2.42 ± 0.69, p = 0.02 vs. baseline). These SUV max values were by contrast much higher at baseline in the 3rd tercile (SUVmax: 2.53 ± 0.83 p = 0.009 vs. 1st tercile) and stable at 6 months (2.49 ± 0.80), while intermediate results were documented in the 2nd tercile. Lastly, the amount of sac shrinkage, expressed in absolute values or in percentages of baseline AAA volumes, was positively correlated with baseline SUVmax (p = 0.001 for both). CONCLUSION: A low pre-EVAR FDG uptake and increased AAA FDG uptake at 6 months are associated with reduced sac shrinkage. This sequential FDG-PET pattern is similar to that already shown to accompany growth phases of medically treated AAA.
Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares , Tomografia por Emissão de Pósitrons , Aorta , Aneurisma da Aorta Abdominal/cirurgia , Fluordesoxiglucose F18 , Humanos , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
OBJECTIVES: This article reports mid-term results of 41 patients treated by the stent assisted balloon induced intimal disruption and relamination (STABILISE) technique for acute type B aortic dissection. METHODS: Between November 2011 and November 2017, 41 patients (10 male; median age 50 years) underwent proximal descending aortic stent grafting plus stent assisted balloon induced intimal disruption of the thoraco-abdominal aorta for acute type B aortic dissection. Serial computed tomography angiography was used to assess aortic remodelling. RESULTS: There were no intra-procedural complications. Fifteen branch arteries supplied by the false lumen were stented (9% of the visceral branch arteries). The thirty day incidence of death, stroke, and paralysis/visceral ischaemia was 2% (n = 1), 0%, 5% (n = 2), and 2% (n = 1) respectively. During a median follow up of 12 months (range 1-168) eight patients (20%) required re-intervention. Primary visceral stent patency was 93% (n = 14). No aortic related deaths occurred. On the most recent computed tomography angiogram, complete false lumen obliteration and aortic remodelling was obtained in all patients at the thoraco-abdominal level, and in 39% (n = 16) at the unstented infrarenal aorto-iliac level. The maximum aortic diameter increased in only two patients (5%) at the unstented infrarenal level. CONCLUSION: To obtain immediate and durable thoraco-abdominal aortic remodelling in acute type B dissections, the STABILISE technique is safe and reproducible while not compromising the patency of collateral branches.
Assuntos
Angioplastia com Balão/instrumentação , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Stents , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Angioplastia com Balão/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Circulação Colateral , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Remodelação VascularRESUMO
OBJECTIVE/BACKGROUND: To evaluate the experimental feasibility of endovascular fenestration using specific endovascular scissor prototypes in an ovine model of acute aortic dissection (AD). METHODS: A previously described endovascular technique was used to create a model of acute type B AD in sheep. Endovascular fenestrations using either endovascular scissor prototypes or a long sheath were compared. Four prototypes of endovascular fenestration scissors were evaluated. Both validity of the experimental model of AD and technical success of endovascular fenestration were assessed by haemodynamic criteria, completion angiography, transesophageal echocardiography, and post-procedural analysis of harvested aortas. RESULTS: Experimental acute AD was created by endovascular means in 17 sheep, with a technical success rate of 82%. Systolic blood pressure was lower in the false lumen than in the true lumen (58 ± 5 vs. 79 ± 3 mmHg, respectively; p < .001). Endovascular fenestration was performed in 11 models (endovascular scissors n = 8; long sheath n = 3). Controlled endovascular fenestration was obtained by the use of endovascular scissors (n = 5/8), resulting in a significant rise in false lumen systolic blood pressure after fenestration (60 ± 2 vs. 67 ± 9 mmHg before and after fenestration, respectively; p < .047). Long sheath fenestration resulted in an uncontrolled flap motion, leading to either pseudo-coarctation syndrome or aortic rupture (58 ± 6 vs. 40 ± 2 mmHg before and after fenestration, respectively; p < .001). CONCLUSION: In this experimental study, a reproducible AD model has been developed in sheep using endovascular procedures exclusively to evaluate endovascular fenestration techniques. Endovascular fenestration using a long sheath appeared hazardous and risky in vivo. Endovascular scissors constitute a dedicated and suitable tool to perform a safe controlled and effective endovascular fenestration in an ovine model.
Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares/instrumentação , Instrumentos Cirúrgicos , Dissecção Aórtica/patologia , Dissecção Aórtica/fisiopatologia , Animais , Aneurisma Aórtico/patologia , Aneurisma Aórtico/fisiopatologia , Pressão Arterial , Modelos Animais de Doenças , Desenho de Equipamento , Estudos de Viabilidade , Teste de Materiais , Carneiro DomésticoRESUMO
We describe an uncommon association of crossed pulmonary arteries and a right aortic arch with a Kommerell diverticulum and a left ligamentum arteriosum, resulting in disabling dysphagia in a 33-year-old woman. First, endovascular exclusion of the Kommerell diverticulum was performed using a thoracic stent graft, associated with left subclavian-carotid transposition. Second, open aneurysmorrhaphy and division of the left ligamentum arteriosum allowed a proper release of the oesophageal compression. Dysphagia completely disappeared in the postoperative course. Control computed tomography angiography at 6-month follow-up showed a satisfactory hybrid repair. A complete understanding of the combined effects of these two anatomical variations on oesophageal compression led to a suitable surgical management.
Assuntos
Aorta Torácica/anormalidades , Aneurisma da Aorta Torácica/complicações , Transtornos de Deglutição/etiologia , Divertículo/complicações , Artéria Pulmonar/anormalidades , Adulto , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Angiografia por Tomografia Computadorizada , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Transtornos de Deglutição/diagnóstico por imagem , Endoscopia do Sistema Digestório , Esôfago/diagnóstico por imagem , Esôfago/patologia , Feminino , Humanos , Artéria Pulmonar/diagnóstico por imagem , Stents , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Cirúrgicos Vasculares/métodosRESUMO
BACKGROUND: Closure of the proximal tear by thoracic endovascular aortic repair (TEVAR) at the acute phase appears to be a safe effective treatment to prevent aneurysmal degeneration type B dissection. However, it appears to be inefficient in up to a third of the patient. We report the technical aspects of our experience with patients undergoing secondary open repair after TEVAR for dissecting thoracoabdominal aneurysm despite early closure proximal tear by TEVAR. METHODS: During a period of 5 years, 96 patients presenting acute type B aortic dissections were treated by TEVAR and followed-up in our institution. Among them, 5 patients experienced an evolution to a dissecting thoracoabdominal aortic aneurysm. Their demographic data and initial medical conditions, delay to reintervention, operative technical details, perioperative and mid-term outcomes were collected and analyzed. RESULTS: All 5 patients (4 male, mean age 58 ± 9) were operated under peripheral normothermic bypass without deep circulatory arrest using the thoracic stent graft as an elephant trunk for completion of the proximal anastomosis. In cases of patency, the false lumen was reapproximated in the anastomosis, 6 visceral arteries were revascularized selectively. One patient died at day 1 of perioperative ventricular fibrillation due to an acute myocardial infarction. The 4 others are alive without complication after a median of 30 months, range (13-22). CONCLUSIONS: In our experience, TEVAR was not only efficient at the acute phase to deal with complications, but in cases of subsequent aneurysmal evolution, it made open repair even easier by avoiding very proximal cross-clamping/anastomosis and circulatory arrest.
Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Fatores de Tempo , Resultado do TratamentoRESUMO
The aim of this case study is to report a case of unusual manifestation of ruptured abdominal aortic aneurysm (AAA) involving an aortocaval fistula (ACF) as phlegmasia cerulea dolens (PCD). A 58-year-old male presented with acute signs of PCD of the right lower limb, confirmed on duplex ultrasonography. Computed tomography angiography revealed a 65-mm ruptured AAA with a large ACF. Successful emergent surgical repair was performed, using implantation of an aortobi-iliac graft with primary closure of the fistula and associated venous thrombectomy. PCD revealing a ruptured AAA with ACF is rare. Knowledge of this original entity might be the most important factor on the outcome.
Assuntos
Aneurisma da Aorta Abdominal/complicações , Ruptura Aórtica/etiologia , Fístula Arteriovenosa/etiologia , Tromboflebite/etiologia , Veia Cava Inferior , Trombose Venosa/etiologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Aortografia/métodos , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/cirurgia , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia/métodos , Trombectomia , Tromboflebite/diagnóstico por imagem , Tromboflebite/cirurgia , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/cirurgiaRESUMO
BACKGROUND: The atheromodulating activity of B cells during the development of atherosclerosis is well documented, but the mechanisms by which these cells are regulated have not been investigated. METHODS AND RESULTS: Here, we analyzed the contribution of Qa-1-restricted CD8(+) regulatory T cells to the control of the T follicular helper-germinal center B-cell axis during atherogenesis. Genetic disruption of CD8(+) regulatory T cell function in atherosclerosis-prone apolipoprotein E knockout mice resulted in overactivation of this axis in secondary lymphoid organs, led to the increased development of tertiary lymphoid organs in the aorta, and enhanced disease development. In contrast, restoring control of the T follicular helper-germinal center B-cell axis by blocking the ICOS-ICOSL pathway reduced the development of atherosclerosis and the formation of tertiary lymphoid organs. Moreover, analyses of human atherosclerotic aneurysmal arteries by flow cytometry, gene expression analysis, and immunofluorescence confirmed the presence of T follicular helper cells within tertiary lymphoid organs. CONCLUSIONS: This study is the first to demonstrate that the T follicular helper-germinal center B-cell axis is proatherogenic and that CD8(+) regulatory T cells control the germinal center reaction in both secondary and tertiary lymphoid organs. Therefore, disrupting this axis represents an innovative therapeutic approach.
Assuntos
Aterosclerose/imunologia , Linfócitos B/imunologia , Linfócitos T CD8-Positivos/imunologia , Centro Germinativo/imunologia , Túnica Adventícia/imunologia , Túnica Adventícia/patologia , Animais , Feminino , Humanos , Técnicas In Vitro , Ligante Coestimulador de Linfócitos T Induzíveis/imunologia , Ligante Coestimulador de Linfócitos T Induzíveis/metabolismo , Camundongos , Camundongos Knockout , Linfócitos T ReguladoresRESUMO
OBJECTIVE: Abdominal aortic aneurysm (AAA) is a particular form of arterial disease characterized by the dilation of the aortic wall and the presence of an intraluminal thrombus linked to a high proteolytic activity. The aim of this study was to investigate the effect of an elastase inhibitor (AZD9668 from AstraZeneca) on aneurysm progression. METHODS: For this purpose, we have used a rat model of elastase perfusion followed by repeated injection of Porphyromonas gingivalis (Pg), a weak periodontal pathogen recently reported to enhance AAA thrombus formation. Pg (1.10(7) colony-forming units) was injected through the jugular vein once a week for 4 weeks, and AZD9668, incorporated in the food, was delivered concomitantly. RESULTS: Our results show a beneficial effect of AZD9668 treatment on AAA progression and composition. The increased AAA diameter induced by Pg was significantly reduced by AZD9668 treatment. Histologic analyses allowed us to observe the persistence of a neutrophil-rich luminal thrombus associated with calcifications in Pg-injected rats and the presence of a healing process in the Pg/AZD9668-treated group. The enhanced concentrations of markers of neutrophil activation, cell-free DNA, and myeloperoxidase and elastase activity in Pg-injected rats were significantly reduced both in the conditioned medium of AAA tissue samples and in plasma of rats injected with Pg and treated with AZD9668. CONCLUSIONS: AZD9668 treatment could therefore constitute a new therapeutic tool for treatment of AAA.
Assuntos
Aorta Abdominal/efeitos dos fármacos , Aneurisma da Aorta Abdominal/tratamento farmacológico , Piridonas/farmacologia , Inibidores de Serina Proteinase/farmacologia , Sulfonas/farmacologia , Animais , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/induzido quimicamente , Aneurisma da Aorta Abdominal/microbiologia , Aneurisma da Aorta Abdominal/patologia , Fosfatos de Cálcio/metabolismo , Dilatação Patológica , Modelos Animais de Doenças , Progressão da Doença , Fibrose , Metaloproteinase 9 da Matriz/metabolismo , Ativação de Neutrófilo/efeitos dos fármacos , Elastase Pancreática , Peroxidase/metabolismo , Porphyromonas gingivalis , Piridonas/sangue , Ratos , Inibidores de Serina Proteinase/sangue , Sulfonas/sangue , Técnicas de Cultura de TecidosRESUMO
PURPOSE: To evaluate midterm outcomes of endovascular repair of types II and III thoracoabdominal aortic aneurysms (TAAA) using the Multilayer Flow Modulator (MFM) in patients unsuitable for open surgery or fenestrated stent-grafts. METHODS: In the prospective, multicenter, nonrandomized STRATO trial (EudraCT registration: 2009-013678-42; ClinicalTrials.gov identifier NCT01756911), 23 patients (mean age 75.8 years; 19 men) with Crawford type II and III TAAA (mean diameter 6.5 cm) were implanted between April 2010 and February 2011. Outcomes included all-cause mortality and stable aneurysm thrombosis with associated branch vessel patency. RESULTS: Through 36 months, there were 7 deaths (none confirmed as aneurysm-related), and no cases of spinal cord injury, device migration or fracture, or respiratory, renal, or peripheral complications. Three patients were lost to follow-up and 2 devices were explanted. The device was patent in the 11 remaining patients at 3 years. Stable aneurysm thrombosis was achieved for 15 of 20 patients at 12 months, 12 of 13 at 24 months, and 10 of 11 at 36 months. The rate of branch patency was 96% at 12 months (primary patency), 100% at 24 months, and 97% at 36 months. Nine patients suffered from endoleaks (attachment site or device overlap); 9 patients underwent 11 reinterventions (3 surgical). Maximum aneurysm diameter was stable for 18 of 20 patients at 12 months, 11 of 13 at 24 months, and 9 of 11 at 36 months. For 10 patients with computed tomography at 36 months, the mean ratio of aneurysm flow volume to total volume had decreased by 83%; the mean ratio of thrombus volume to total volume increased by 159%. CONCLUSION: Through 3 years, endovascular repair with the MFM appears to be safe and effective while successfully maintaining branch vessel patency.