Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Med Imaging (Bellingham) ; 9(3): 031509, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-36267352

RESUMO

Purpose: The morphology of a polymer aligner, designed according to an orthodontic treatment plan, determines clinical outcomes. A fundamental element of orthodontic tooth movement with aligner treatment is the fit of the aligner's surface to the individual teeth. Gaps between the aligner and teeth do occur because current aligner fabrication is not capable of completely reproducing the complex anatomy of the individual denture. Our study aims at a quantitative three-dimensional assessment of the fit between optically transparent aligners placed on a polymeric model of the upper dental arch for two thermofoil thicknesses at preselected thermoforming temperatures. Approach: Using an intraoral scan of a subject's upper dental arch, eight models were printed using a stereolithographic system. A series of eight NaturAligners® was manufactured with a pressure molding process, using thermofoils with thicknesses of 550 and 750 µ m and preselected process temperatures between 110°C and 210°C. These aligners placed on the corresponding models were imaged by an advanced micro computed tomography system. The aligners and the models were segmented to extract the gaps and aligners' local thicknesses as a function of the processing temperature for the two foil thicknesses. Results: The results indicate that the aligners show a better fit when the foils are processed at higher temperatures. Nevertheless, processing temperatures can be kept below 150°C, as the gain becomes negligible. Thermal processing reduces the average thickness of the aligners to 60% with respect to the planar starting foil. These thickness distributions demonstrate that the aligners are generally thicker on the occlusal surfaces of molars and premolars but thinner around the incisors and buccal as well as on oral surfaces. Conclusions: Hard x-ray tomography with micrometer resolution is a powerful technique employed to localize the gaps between aligners and teeth, and it also enables film thickness measurements after thermoforming. The thicker film on the occlusal surfaces is most welcome because of aligner abrasion during wear. The NaturAligner® surfaces consist of a 25 - µ m -thin cellulose layer, and thus the microplastics released via abrasion of less than this thickness are expected to be substantially less critical than for other commercially available, optically transparent aligners.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA