Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
3.
ACS Macro Lett ; 11(3): 317-322, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35575357

RESUMO

The COVID-19 pandemic has highlighted the need for innovative biosensing, diagnostic, and surveillance platforms. Here we report that glycosylated, polymer-stabilized, gold nanorods can bind the SARS-CoV-2 spike protein and show correlation to the presence of SARS-CoV-2 in primary COVID-19 clinical samples. Telechelic polymers were prepared by reversible addition-fragmentation chain-transfer polymerization, enabling the capture of 2,3-sialyllactose and immobilization onto gold nanorods. Control experiments with a panel of lectins and a galactosamine-terminated polymer confirmed the selective binding. The glycosylated rods were shown to give dose-dependent responses against recombinant truncated SARS-CoV-2 spike protein, and the responses were further correlated using primary patient swab samples. The essentiality of the anisotropic particles for reducing the background interference is demonstrated. This highlights the utility of polymer tethering of glycans for plasmonic biosensors of infection.


Assuntos
COVID-19 , Nanotubos , COVID-19/diagnóstico , Ouro , Humanos , Pandemias , Polímeros , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/metabolismo
4.
ACS Sens ; 6(10): 3696-3705, 2021 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-34634204

RESUMO

The COVID-19 pandemic, and future pandemics, require diagnostic tools to track disease spread and guide the isolation of (a)symptomatic individuals. Lateral-flow diagnostics (LFDs) are rapid and of lower cost than molecular (genetic) tests, with current LFDs using antibodies as their recognition units. Herein, we develop a prototype flow-through device (related, but distinct to LFDs), utilizing N-acetyl neuraminic acid-functionalized, polymer-coated, gold nanoparticles as the detection/capture unit for SARS-COV-2, by targeting the sialic acid-binding site of the spike protein. The prototype device can give rapid results, with higher viral loads being faster than lower viral loads. The prototype's effectiveness is demonstrated using spike protein, lentiviral models, and a panel of heat-inactivated primary patient nasal swabs. The device was also shown to retain detection capability toward recombinant spike proteins from several variants (mutants) of concern. This study provides the proof of principle that glyco-lateral-flow devices could be developed to be used in the tracking monitoring of infectious agents, to complement, or as alternatives to antibody-based systems.


Assuntos
COVID-19 , Nanopartículas Metálicas , Ouro , Humanos , Pandemias , Polissacarídeos , SARS-CoV-2
5.
J Appl Psychol ; 101(4): 582-604, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26653532

RESUMO

In this study, we examine the structures of 10 personality inventories (PIs) widely used for personnel assessment by mapping the scales of PIs to the lexical Big Five circumplex model resulting in a Periodic Table of Personality. Correlations between 273 scales from 10 internationally popular PIs with independent markers of the lexical Big Five are reported, based on data from samples in 2 countries (United Kingdom, N = 286; United States, N = 1,046), permitting us to map these scales onto the Abridged Big Five Dimensional Circumplex model (Hofstee, de Raad, & Goldberg, 1992). Emerging from our findings we propose a common facet framework derived from the scales of the PIs in our study. These results provide important insights into the literature on criterion-related validity of personality traits, and enable researchers and practitioners to understand how different PI scales converge and diverge and how compound PI scales may be constructed or replicated. Implications for research and practice are considered.


Assuntos
Modelos Psicológicos , Inventário de Personalidade/estatística & dados numéricos , Inventário de Personalidade/normas , Personalidade , Análise Fatorial , Feminino , Humanos , Masculino , Psicometria , Reprodutibilidade dos Testes , Reino Unido , Estados Unidos
6.
Rev Saude Publica ; 50: 52, 2016 Aug 22.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27556966

RESUMO

OBJECTIVE: To adapt and validate the Team Climate Inventory scale, of teamwork climate measurement, for the Portuguese language, in the context of primary health care in Brazil. METHODS: Methodological study with quantitative approach of cross-cultural adaptation (translation, back-translation, synthesis, expert committee, and pretest) and validation with 497 employees from 72 teams of the Family Health Strategy in the city of Campinas, SP, Southeastern Brazil. We verified reliability by the Cronbach's alpha, construct validity by the confirmatory factor analysis with SmartPLS software, and correlation by the job satisfaction scale. RESULTS: We problematized the overlap of items 9, 11, and 12 of the "participation in the team" factor and the "team goals" factor regarding its definition. The validation showed no overlapping of items and the reliability ranged from 0.92 to 0.93. The confirmatory factor analysis indicated suitability of the proposed model with distribution of the 38 items in the four factors. The correlation between teamwork climate and job satisfaction was significant. CONCLUSIONS: The version of the scale in Brazilian Portuguese was validated and can be used in the context of primary health care in the Country, constituting an adequate tool for the assessment and diagnosis of teamwork. OBJETIVO: Adaptar e validar a escala Team Climate Invetory, de medida do clima de trabalho em equipe, para o idioma português, no contexto da atenção primária à saúde no Brasil. MÉTODOS: Estudo metodológico com abordagem quantitativa de adaptação transcultural (tradução, retrotradução, síntese, comitê de especialistas e pré-teste) e validação com 497 trabalhadores de 72 equipes da Estratégia Saúde da Família no município de Campinas, São Paulo. Verificou-se confiabilidade pelo alfa de Cronbach, validade de construto pela análise fatorial confirmatória pelo software SmartPLS e correlação com escala de satisfação no trabalho. RESULTADOS: Foi problematizado a sobreposição dos itens 9, 11 e 12 do fator participação na equipe e o fator objetivos da equipe no tocante à sua definição. A validação mostrou que não houve sobreposição dos itens e a confiabilidade variou entre 0,92 a 0,93. A análise fatorial confirmatória indicou adequação do modelo proposto com distribuição dos 38 itens nos quatro fatores. A correlação entre clima de trabalho em equipe e satisfação no trabalho foi significativa. CONCLUSÕES: A versão da escala em português falado no Brasil foi validada e pode ser utilizada no contexto da atenção primária à saúde no País, constituindo ferramenta adequada para a avaliação e diagnóstico do trabalho em equipe.


Assuntos
Comparação Transcultural , Equipe de Assistência ao Paciente/organização & administração , Gestão da Segurança , Inquéritos e Questionários , Traduções , Brasil , Humanos , Relações Interpessoais , Satisfação no Emprego , Reprodutibilidade dos Testes
7.
Rev. saúde pública (Online) ; 50: 52, 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-962236

RESUMO

ABSTRACT OBJECTIVE To adapt and validate the Team Climate Inventory scale, of teamwork climate measurement, for the Portuguese language, in the context of primary health care in Brazil. METHODS Methodological study with quantitative approach of cross-cultural adaptation (translation, back-translation, synthesis, expert committee, and pretest) and validation with 497 employees from 72 teams of the Family Health Strategy in the city of Campinas, SP, Southeastern Brazil. We verified reliability by the Cronbach's alpha, construct validity by the confirmatory factor analysis with SmartPLS software, and correlation by the job satisfaction scale. RESULTS We problematized the overlap of items 9, 11, and 12 of the "participation in the team" factor and the "team goals" factor regarding its definition. The validation showed no overlapping of items and the reliability ranged from 0.92 to 0.93. The confirmatory factor analysis indicated suitability of the proposed model with distribution of the 38 items in the four factors. The correlation between teamwork climate and job satisfaction was significant. CONCLUSIONS The version of the scale in Brazilian Portuguese was validated and can be used in the context of primary health care in the Country, constituting an adequate tool for the assessment and diagnosis of teamwork.


RESUMO OBJETIVO Adaptar e validar a escala Team Climate Invetory, de medida do clima de trabalho em equipe, para o idioma português, no contexto da atenção primária à saúde no Brasil. MÉTODOS Estudo metodológico com abordagem quantitativa de adaptação transcultural (tradução, retrotradução, síntese, comitê de especialistas e pré-teste) e validação com 497 trabalhadores de 72 equipes da Estratégia Saúde da Família no município de Campinas, São Paulo. Verificou-se confiabilidade pelo alfa de Cronbach, validade de construto pela análise fatorial confirmatória pelo software SmartPLS e correlação com escala de satisfação no trabalho. RESULTADOS Foi problematizado a sobreposição dos itens 9, 11 e 12 do fator participação na equipe e o fator objetivos da equipe no tocante à sua definição. A validação mostrou que não houve sobreposição dos itens e a confiabilidade variou entre 0,92 a 0,93. A análise fatorial confirmatória indicou adequação do modelo proposto com distribuição dos 38 itens nos quatro fatores. A correlação entre clima de trabalho em equipe e satisfação no trabalho foi significativa. CONCLUSÕES A versão da escala em português falado no Brasil foi validada e pode ser utilizada no contexto da atenção primária à saúde no País, constituindo ferramenta adequada para a avaliação e diagnóstico do trabalho em equipe.


Assuntos
Humanos , Equipe de Assistência ao Paciente/organização & administração , Traduções , Comparação Transcultural , Gestão da Segurança , Brasil , Inquéritos e Questionários , Reprodutibilidade dos Testes , Relações Interpessoais , Satisfação no Emprego
8.
Med Sci Monit ; 8(11): CR725-7, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12444374

RESUMO

BACKGROUND: Microalbuminuria, a marker of endothelial cell dysfunction, is associated with atherosclerosis and is a predictor of coronary heart disease. It has been suggested that patients with coronary heart disease have exaggerated exercise-induced urinary microalbumin excretion but this is controversial. We, therefore, measured urine microalbumin excretion in men before and after an exercise electrocardiogram. MATERIAL/METHODS: Urine microalbumin excretion expressed as the albumin-creatinine ratio (ACR) was measured before and after an exercise electrocardiogram in 10 subjects with exercise-induced myocardial ischaemia and 14 subjects without exercise-induced myocardial ischaemia. RESULTS: In subjects with a positive exercise electrocardiogram, the pre-exercise electrocardiogram ACR 3.3 +/- 5.50; (mean+/-SD) significantly increased (p=0.0371) following exercise (6.30 +/-10.25). In subjects with a negative exercise electrocardiogram, the pre-exercise electrocardiogram ACR (0.73 +/-0.52) also significantly increased (p=0.0295) following exercise (2.04 +/-1.81). Pre-exercise ACR was higher (p=0.0164) in subjects with a positive exercise electrocardiogram (3.3 +/-5.50) than in those subjects with a negative exercise electrocardiogram (0.73 +/-0.52). Incremental and post-exercise ACR were not significantly different in those with normal and abnormal exercise electrocardiograms. CONCLUSIONS: Patients with exercise-induced myocardial ischaemia have pre-exercise urine microalbumin excretion. Exaggerated urine microalbumin excretion in response to exercise is not associated with exercise-induced myocardial ischaemia.


Assuntos
Albuminúria/etiologia , Exercício Físico , Isquemia Miocárdica , Idoso , Doença da Artéria Coronariana/terapia , Eletrocardiografia , Teste de Esforço , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
9.
Med Sci Monit ; 9(12): CR511-4, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14646972

RESUMO

BACKGROUND: Nitric oxide (NO) plays a pivotal role in the pathophysiology of coronary heart disease (CHD). Low plasma concentrations of NO metabolites (nitrite and nitrate), the stable oxidation products of NO have been reported in patients with CHD but this is controversial. Plasma nitrite and nitrate concentrations during symptomatic myocardial ischaemia and in response to exercise in subjects with CHD have not been studied. We therefore measured plasma nitrite and nitrate concentrations in subjects before and after an exercise tolerance test (ETT). MATERIAL/METHODS: Plasma nitrite and nitrate concentrations were measured before and after an ETT in 24 subjects with symptomatic exercise-induced myocardial ischaemia (positive ETT) and in 27 subjects without exercise-induced myocardial ischaemia (negative ETT). RESULTS: Plasma nitrate concentrations were higher (p<0.002) before and after the ETT in subjects with a positive ETT (31.51+/-21.80 mol/L and 30.86+/-21.42 mol/L respectively) than in the subjects with a negative ETT (14.75+/-6.71 mol/L and 15.64+/-6.50 mol/L respectively). Plasma nitrite concentrations before and after the ETT were similar in both groups. Within each group, plasma nitrite and nitrate concentrations were not altered by exercise. CONCLUSIONS: Subjects with exercise-induced myocardial ischaemia have higher plasma nitrate concentration than subjects without exercise-induced myocardial ischaemia. This is consistent with either a compensatory or an inflammatory response of the vascular endothelium to endothelial damage. Symptomatic exercise-induced ischaemia is not associated with altered plasma NO metabolite concentrations.


Assuntos
Isquemia Miocárdica/metabolismo , Óxido Nítrico/metabolismo , Adulto , Idoso , Estudos de Casos e Controles , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/sangue , Nitratos/sangue , Nitritos/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA