Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Transfus Apher Sci ; 61(2): 103318, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34782243

RESUMO

BACKGROUND: The introduction of chemiluminescent immunoassay (CLIA) in blood donor screening has led to a gradual replacement of enzyme-linked-immunosorbent assay (ELISA) as the former offers automation, higher sensitivity and lower turn-around-time. However, only a few CLIA platforms are used for blood donor screening in India. The present study evaluated one such newer platform viz., Adiva Centaur XP CLIA for screening of HBV, HCV, HIV and syphilis. MATERIAL AND METHODS: Prospective comparative study wherein 4843 whole blood donors were screened for HBsAg, Anti-HCV, HIV Ag-Ab and Anti-treponemal antibodies in both Advia Centaur XP and Architect i2000SR platforms. Additional tests were performed in samples which were reactive in only one of the platforms. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy, false positive rate and false negative rate of both the platforms were compared. Kappa coefficient was calculated to determine the agreement between the testing platforms. RESULTS: The sensitivity of Advia Centaur platform for HBV, HCV, HIV and syphilis detection were 94.9 %, 100 %, 100 % and 100 % respectively as compared to 96.6 %, 100 %, 100 % and 100 % in Architect i2000SR platform. The specificity of both the platforms were 99.8-99.9 % for all the four tests. The agreement between the two platforms was almost perfect for HBV, HCV and syphilis testing; and fair for HIV testing. CONCLUSION: The Advia Centaur CLIA platform was found to be comparable with the Architect CLIA platform for blood donor screening. Unexpected finding was the occurrence of HBV false negatives in both the platforms, possibly due to HBsAg mutations.


Assuntos
Infecções por HIV , Hepatite C , Sífilis , Doadores de Sangue , Infecções por HIV/diagnóstico , Antígenos de Superfície da Hepatite B , Vírus da Hepatite B , Hepatite C/diagnóstico , Humanos , Imunoensaio , Luminescência , Estudos Prospectivos , Sífilis/diagnóstico
2.
Vox Sang ; 116(5): 497-503, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33103772

RESUMO

INTRODUCTION: Numerous concerns regarding maintenance of blood inventory have been raised after SARS-CoV-2 pandemic outbreak. These concerns were based on the experience of blood centres in previous pandemics where shortage of blood components was reported. The present study had tried to understand the impact of SARS-CoV-2 pandemic on blood collection and demand as well as the impact of disaster planning in maintaining an adequate inventory. METHODS: Data related to blood supply and demand were collected retrospectively using blood bank management software for pre-COVID-19 and COVID-19 time period and compared. Strategies adopted and effects of changes in existing disaster plans to maintain an adequate inventory were studied. RESULTS: A drastic fall in the red cell inventory was observed as compared to pre-COVID-19 time period was observed due to disproportionate decrease in blood collection (1/6 to 1/9 of the previous collection) and demand (1/2 of the previous demand). The buffer stock fell gradually over a period of three weeks with cancellation of planned blood donation drives. A buffer stock equivalent to 2-week inventory led to adequate inventory in the initial lockdown periods. Similar fall was observed in the platelet inventory with reduction in the blood collection but almost a proportionate reduction in the platelet demand led to adequate inventory. No increase in wastage was observed for both red cells and platelets during this period. DISCUSSION: A buffer stock of blood and blood components, strict adherence to the transfusion triggers, good coordination with the clinical staff and a prospective review of blood transfusion requests to ensure rational blood transfusion were some of the steps which helped us to successfully maintain transfusion requirements in the initial phases of the COVID-19 pandemic. Use of first-in-first-out policy prevented any wastage due to outdating of blood.


Assuntos
Bancos de Sangue/organização & administração , Segurança do Sangue/normas , COVID-19/epidemiologia , Bancos de Sangue/normas , Doadores de Sangue/provisão & distribuição , Segurança do Sangue/métodos , Hospitais/normas , Humanos
3.
J Clin Apher ; 36(1): 41-47, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32894894

RESUMO

BACKGROUND: Single donor apheresis platelets are superior in quality, but their usage is limited in a developing country due to cost and time constraints. Hence the product obtained must exceed in terms of yield, donor safety and technical convenience. Previous literature available on cell separators is on older versions. AIMS: Prospective comparison of 5 latest cell separators (AmiCORE, COM.TEC, Haemonetics MCS+, SpectraOptia and TrimaAccel) for product yield, performance variables and donor adverse effects. MATERIAL & METHODS: From October 2019 - March 2020, 1108 donors were randomly allotted to a cell separator. Post-donation sample was taken from the donor 15-20 minutes after procedure completion. The platelet yield from the product collected was measured twice (day 0 and day 1). Donor demography, pre-and post-procedural donor peripheral blood values, performance and product variables were statistically analyzed. RESULTS: AmiCORE had an optimal collection efficacy (44.6%) and collection rate (0.037 x 1011/minute). Haemonetics MCS+ had a better collection efficacy (48.4%) and rate (0.038 x 1011/minute). Spectra Optia achieved least procedural time (59.5 minutes), donor adverse effects (6.3%); highest collection efficacy (52.8%) and rate (0.056 x 1011/minute). Trima Accel achieved highest collection rate (0.056 x 1011/minute) and the least product volume (228 ml). CONCLUSION: Highest collection efficacy was achieved by Trima Accel, highest collection rate by Trima Accel and Spectra Optia, lowest donor adverse effects by Spectra Optia and least number of procedural troubleshooting by COM.TEC. Apart from this, fiscal factors and service availability also need to be considered before choosing a cell separator.


Assuntos
Plaquetoferese/instrumentação , Adulto , Doadores de Sangue , Feminino , Humanos , Masculino , Estudos Prospectivos , Centros de Atenção Terciária , Adulto Jovem
4.
Indian J Hematol Blood Transfus ; 38(3): 437-443, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35035128

RESUMO

Temporarily deferred donors are a forgotten pool of potential blood source. When dealt appropriately, they can easily be inducted back to the main stream pool of voluntary donors. Although there are multiple studies from India on the deferral rates and patterns; not much has been done with respect to the follow up of these donors and active efforts to bring them back to donate blood. In this narrative review, we discuss the impact of temporary deferral, factors affecting the return and appropriate strategies to improve the return rate of these donors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA