Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 93(47): 15744-15751, 2021 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-34783529

RESUMO

We present a pH nanosensor conceived for single intracellular measurements. The sensing architecture consisted of a two-electrode system evaluated in the potentiometric mode. We used solid-contact carbon nanopipette electrodes tailored to produce both the indicator (pH nanosensor) and reference electrodes. The indicator electrode was a membrane-based ion-selective electrode containing a receptor for hydrogen ions that provided a favorable selectivity for intracellular measurements. The analytical features of the pH nanosensor revealed a Nernstian response (slope of -59.5 mV/pH unit) with appropriate repeatability and reproducibility (variation coefficients of <2% for the calibration parameters), a fast response time (<5 s), adequate medium-term drift (0.7 mV h-1), and a linear range of response including physiological and abnormal cell pH levels (6.0-8.5). In addition, the position and configuration of the reference electrode were investigated in cell-based experiments to provide unbiased pH measurements, in which both the indicator and reference electrodes were located inside the same cell, each of them inside two neighboring cells, or the indicator electrode inside the cell and the reference electrode outside of (but nearby) the studied cell. Finally, the pH nanosensor was applied to two cases: (i) the tracing of the pH gradient from extra-to intracellular media over insertion into a single PC12 cell and (ii) the monitoring of variations in intracellular pH in response to exogenous administration of pharmaceuticals. It is anticipated that the developed pH nanosensor, which is a label-free analytical tool, has high potential to aid in the investigation of pathological states that manifest in cell pH misregulation, with no restriction in the type of targeted cells.


Assuntos
Eletrodos Seletivos de Íons , Prótons , Concentração de Íons de Hidrogênio , Potenciometria , Reprodutibilidade dos Testes
2.
Anal Chem ; 92(16): 11325-11331, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32692153

RESUMO

We have designed and fabricated a microwell array chip (MWAC) to trap and detect the entire content of individual vesicles after disruption of the vesicular membrane by an applied electrical potential. To understand the mechanism of vesicle impact electrochemical cytometry (VIEC) in microwells, we simulated the rupture of the vesicles and subsequent diffusion of entrapped analytes. Two possibilities were tested: (i) the vesicle opens toward the electrode, and (ii) the vesicle opens away from the electrode. These two possibilities were simulated in the different microwells with varied depth and width. Experimental VIEC measurements of the number of molecules for each vesicle in the MWAC were compared to VIEC on a gold microdisk electrode as a control, and the quantified catecholamines between these two techniques was the same. We observed a prespike foot in a significant number of events (∼20%) and argue this supports the hypothesis that the vesicles rupture toward the electrode surface with a more complex mechanism including the formation of a stable pore intermediate. This study not only confirms that in standard VIEC experiments the whole content of the vesicle is oxidized and quantified at the surface of the microdisk electrode but actively verifies that the adsorbed vesicle on the surface of the electrode forms a pore in the vicinity of the electrode rather than away from it. The fabricated MWAC promotes our ability to quantify the content of vesicles accurately, which is fundamentally important in bioanalysis of the vesicles.


Assuntos
Catecolaminas/análise , Técnicas Eletroquímicas/métodos , Lipossomos/análise , Técnicas Analíticas Microfluídicas/métodos , Técnicas Eletroquímicas/instrumentação , Eletrodos , Ouro/química , Dispositivos Lab-On-A-Chip , Lipossomos/química , Técnicas Analíticas Microfluídicas/instrumentação
3.
J Nanosci Nanotechnol ; 15(5): 3429-36, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26504962

RESUMO

Simultaneous determination of N-acetyl-L-cysteine (NAC) and Tryptophan (Trp) has been studied at the surface of glassy carbon electrode (GCE) modified with multi-walled carbon nanotubes (MWCNTs) in the presence of 4-chlorocatechol as homogenous electrochemical catalyst in aqueous media. The electrocatalytic properties of GCE modified with MWCNTs in the presence of 4-chlorocatechol toward the electrocatalytic oxidation of NAC and Trp was studied using cyclic voltammetry (CV), double-step potential chronoamperometry and differential pulse voltammetry (DPV). The results has shown that NAC participates in Michael type addition reaction with electrogenerated quinone from electrooxidation of 4-chlorocatechol at MWCNT/GCE to form the corresponding thioquinone derivative. The reoxidation of the adduct leads to increase in the oxidative current which is proportional to the concentration of NAC. Differential pulse voltammogram peak currents of NAC and Trp increased linearly with their concentration at the ranges of 5-60 µM and 5-50 µM, respectively and the detection limits for NAC and Trp were sequentially 3.427 µM and 2.494 µM. The proposed method was successfully used for the determination of NAC in pharmaceutical samples and the obtained results were found to be reasonable.


Assuntos
Acetilcisteína/análise , Catecóis/química , Técnicas Eletroquímicas/métodos , Nanotubos de Carbono/química , Triptofano/química , Eletrodos , Limite de Detecção , Oxirredução
5.
Chem Sci ; 11(43): 11869-11876, 2020 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34123212

RESUMO

Using a nano-injection method, we introduced phospholipids having different intrinsic geometries into single secretory cells and used single cell amperometry (SCA) and intracellular vesicle impact electrochemical cytometry (IVIEC) with nanotip electrodes to monitor the effects of intracellular incubation on the exocytosis process and vesicular storage. Combining tools, this work provides new information to understand the impact of intracellular membrane lipid engineering on exocytotic release, vesicular content and fraction of chemical release. We also assessed the effect of membrane lipid alteration on catecholamine storage of isolated vesicles by implementing another amperometric technique, vesicle impact electrochemical cytometry (VIEC), outside the cell. Exocytosis analysis reveals that the intracellular nano-injection of phosphatidylcholine and lysophosphatidylcholine decreases the number of released catecholamines, whereas phosphatidylethanolamine shows the opposite effect. These observations support the emerging hypothesis that lipid curvature results in membrane remodeling through secretory pathways, and also provide new evidence for a critical role of the lipid localization in modulating the release process. Interestingly, the IVIEC data imply that total vesicular content is also affected by in situ supplementation of the cells with some lipids, while, the corresponding VIEC results show that the neurotransmitter content in isolated vesicles is not affected by altering the vesicle membrane lipids. This suggests that the intervention of phospholipids inside the cell has its effect on the cellular machinery for vesicle release rather than vesicle structure, and leads to the somewhat surprising conclusion that modulating release has a direct effect on vesicle structure, which is likely due to the vesicles opening and closing again during exocytosis. These findings could lead to a novel regulatory mechanism for the exocytotic or synaptic strength based on lipid heterogeneity across the cell membrane.

6.
Biosens Bioelectron ; 85: 814-821, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27290665

RESUMO

A novel biosensing platform based on fractal-pattern of iron oxides magnetic nanostructures (FIOMNs) and mixed hemi/ad-micelle of sodium dodecyl sulfate (SDS) was designed for the magnetic immobilization of hemoglobin (Hb) at a screen printed carbon electrode (SPCE). The FIOMNs was successfully synthesized through hydrothermal approach and characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM) and X-ray diffraction (XRD). In order to provide guidelines for the mixed hemi/ad-micelle formation, zeta-potential isotherms were investigated. The construction steps of the biosensor were evaluated by electrochemical impedance spectroscopy, cyclic voltammetry and Fourier transform infrared spectroscopy. Direct electron transfer of Hb incorporated into the biocomposite film was realized with a pair of quasi-reversible redox peak at the formal potential of -0.355V vs. Ag/AgCl attributing to heme Fe(III)/Fe(II) redox couple. The results suggested that synergistic functions regarding to the hyper-branched and multidirectional structure of FIOMNs and the dual interaction ability of mixed hemi/ad-micelle array of SDS molecules not only induce an effective electron transfer between the Hb and the underlying electrode (high heterogeneous electron transfer rate constant of 2.08s(-1)) but also provide powerful and special microenvironment for the adsorption of the redox proteins. Furthermore, the biosensor displayed an excellent performance to the electrocatalytic reduction of H2O2 with a detection limit of 0.48µM and Michaelis-Menten constant (Km) value of 44.2µM. The fabricated biosensor represented the features of sensitivity, disposable design, low sample volume, rapid and simple preparation step, and acceptable anti-interferences, which offer great perspectives for the screen-determination of H2O2 in real samples.


Assuntos
Técnicas Biossensoriais/métodos , Compostos Férricos/química , Hemoglobinas/química , Peróxido de Hidrogênio/análise , Proteínas Imobilizadas/química , Imãs/química , Nanoestruturas/química , Catálise , Técnicas Eletroquímicas/métodos , Eletrodos , Transporte de Elétrons , Humanos , Peróxido de Hidrogênio/sangue , Peróxido de Hidrogênio/urina , Micelas , Antissépticos Bucais/análise , Nanoestruturas/ultraestrutura , Oxirredução , Chuva/química , Dodecilsulfato de Sódio/química
7.
Biosens Bioelectron ; 74: 518-25, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26183073

RESUMO

An efficient procedure for the physical entrapment of proteins within a biocompatible matrix and their immobilization on electrode surfaces is of utmost importance in the fabrication of biosensors. In this work, the magnetic entrapment of hemoglobin (Hb) at the surface of a screen-printed carbon electrode (SPCE), through mixed hemi/ad-micelles (MHAM) array of positively charged surfactant supported iron oxide magnetic nanoparticles (Mag-NPs), is reported. The Hb/MHAM@Mag-NPs biocomposite is captured at SPCE by a super magnet (Hb/MHAM@Mag-NPs/SPCE). To gain insight in the configuration of the mixed hemi/ad-micelles of CTAB at Mag-NPs, zeta-potential measurements were performed. The entrapment of Hb at MHAM@Mag-NPs was confirmed by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and Fourier transform infrared spectroscopy (FT-IR). Direct electron transfer of the Hb intercalated into the composite film showed a pair of well-defined quasi-reversible redox peak at formal potential of -0.255 V vs. Ag/AgCl corresponding to heme Fe(III)/Fe(II) redox couple. It shows that the MHAM@Mag-NPs composite could increase the adsorption ability for Hb, thus provides a facile direct electron transfer between the Hb and the substrate. The proposed biosensor showed excellent electrocatalytic activity to the H2O2 reduction in the wide concentration range from 5.0 to 300.0 µM obtained by amperometric measurement. The Michaelis-Menten constant (Km) value of Hb at the modified electrode is 55.4 µM, showing its high affinity. Magnetic entrapment offers a promising design for fast, convenient and effective immobilization of protein within a few minutes for determination of the target molecule in low sample volume at disposable cost-effective SPCE.


Assuntos
Condutometria/instrumentação , Eletrodos , Hemoglobinas/química , Peróxido de Hidrogênio/análise , Separação Imunomagnética/instrumentação , Nanopartículas de Magnetita/química , Adsorção , Carbono/química , Catálise , Materiais Revestidos Biocompatíveis/síntese química , Equipamentos Descartáveis , Desenho de Equipamento , Análise de Falha de Equipamento , Peróxido de Hidrogênio/química , Nanopartículas de Magnetita/ultraestrutura , Impressão Tridimensional
8.
Colloids Surf B Biointerfaces ; 109: 287-93, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-23680846

RESUMO

For the first time, electrocatalytic oxidation and selective determination of methadone (Mtd), as a long-acting opioid, in the presence of acetaminophen (Ac) has been investigated at a glassy carbon electrode modified with functionalized multi-walled carbon nanotubes. This simple and sensitive electrochemical sensor was fabricated through the drop-casting of functionalized multi-walled carbon nanotubes (fMWCNT) on the surface of a glassy carbon electrode (GCE). The electrocatalytic oxidations of Ac and Mtd are both individually and simultaneously investigated at the surface of the fMWCNT modified glassy carbon electrode (fMWCNT/MGCE) through using cyclic and differential pulse voltammetric studies. The fMWCNT/MGCE offered a considerable enhancement in the anodic peak current of Ac and Mtd associated with separating their overlapping voltammetric responses with potential difference of 290 mV. The catalytic peak currents obtained from differential pulse voltammetry of Ac and Mtd increased linearly with their concentration at the ranges of 0.45-90.0 µM and 0.5-100.0 µM, respectively, and the detection limits for Ac and Mtd were sequentially 0.35 µM and 0.28 µM. Furthermore, this electrochemical sensor was successfully implemented for the quantitative determination of Ac and Mtd in human urine, saliva and pharmaceutical samples using standard addition method and the obtained results were found to be satisfactory.


Assuntos
Acetaminofen/química , Analgésicos Opioides/análise , Carbono/química , Metadona/análise , Nanotubos de Carbono/química , Saliva/química , Urina/química , Analgésicos Opioides/química , Catálise , Técnicas Eletroquímicas , Eletrodos , Vidro/química , Humanos , Metadona/química , Oxirredução , Tamanho da Partícula , Propriedades de Superfície , Comprimidos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA