Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur Radiol ; 31(9): 7077-7087, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33755754

RESUMO

OBJECTIVES: To assess changes in working patterns and education experienced by radiology residents in Northwest Italy during the COVID-19 pandemic. METHODS: An online questionnaire was sent to residents of 9 postgraduate schools in Lombardy and Piedmont, investigating demographics, changes in radiological workload, involvement in COVID-19-related activities, research, distance learning, COVID-19 contacts and infection, changes in training profile, and impact on psychological wellbeing. Descriptive and χ2 statistics were used. RESULTS: Among 373 residents invited, 300 (80%) participated. Between March and April 2020, 44% (133/300) of respondents dedicated their full time to radiology; 41% (124/300) engaged in COVID-19-related activities, 73% (90/124) of whom working in COVID-19 wards; 40% (121/300) dedicated > 25% of time to distance learning; and 66% (199/300) were more involved in research activities than before the pandemic. Over half of residents (57%, 171/300) had contacts with COVID-19-positive subjects, 5% (14/300) were infected, and 8% (23/300) lost a loved one due to COVID-19. Only 1% (3/300) of residents stated that, given the implications of this pandemic scenario, they would not have chosen radiology as their specialty, whereas 7% (22/300) would change their subspecialty. The most common concerns were spreading the infection to their loved ones (30%, 91/300), and becoming sick (7%, 21/300). Positive changes were also noted, such as being more willing to cooperate with other colleagues (36%, 109/300). CONCLUSIONS: The COVID-19 pandemic changed radiology residents' training programmes, with distance learning, engaging in COVID-19-related activities, and a greater involvement in research becoming part of their everyday practice. KEY POINTS: • Of 300 participants, 44% were fully dedicated to radiological activity and 41% devoted time to COVID-19-related activities, 73% of whom to COVID-19 wards. • Distance learning was substantial for 40% of residents, and 66% were involved in research activities more than before the COVID-19 pandemic. • Over half of residents were exposed to COVID-19 contacts and less than one in twenty was infected.


Assuntos
COVID-19 , Internato e Residência , Radiologia , Humanos , Itália/epidemiologia , Pandemias , SARS-CoV-2 , Inquéritos e Questionários
2.
Diagn Interv Imaging ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38866665

RESUMO

PURPOSE: The purpose of this study was to identify potential association between transverse sinus stenosis (TSS) and temporal bone thinning downstream of TSS on computed tomography (CT). MATERIALS AND METHODS: Clinical and radiological data of patients with venous pulsatile tinnitus due to TSS (TSS group) and treated with stenting from 2019 to 2022 were retrospectively collected. An age-matched control group of patients with venous or neutral pulsatile tinnitus (control group) was built. CT measurements of temporal bone thickness were performed at the level of transverse-sigmoid sinus junction (E1) and the occipitomastoid suture (E2). E1; E2 and E1/E2 ratios obtained in TSS and control groups were compared. RESULTS: A total of 122 patients with venous pulsatile tinnitus were included. There were 56 patients with TSS (TSS group; 56 women; mean age, 35.5 ± 11.3 [standard deviation] years) and 66 patients without TSS (control group; 54 women; mean age, 37.7 ± 10.5 [standard deviation] years). E1 measurements and E1/E2 ratios on the symptomatic and dominant sides were significantly lower in the TSS group by comparison with the contralateral side of the same group (P < 0.05) and the ipsilateral side of the control group (P < 0.05). There were no differences in median E2 values between the TSS group (6.8 mm; range: 3.5-10.8 mm) and the control group (7.1 mm; range: 2.9-11.2 mm) (P = 0.098). E1 = 0 mm was found only in the TSS group. At receiver operating characteristic (ROC) analysis, an E1/E2 ratio threshold of 0.562 maximized the ability to predict presence of TSS. An E1/E2 ratio < 0.562 was predictive of symptomatic TSS with an accuracy of 74% (95% confidence interval: 65-82%). The AUC for the diagnosis of TSS was 0.807 (95% CI: 0.729-0.885). CONCLUSION: Temporal bone thickness is significantly reduced downstream of the stenosis on the pulsatile tinnitus side and may be a good indicator of symptomatic TSS.

3.
Eur J Radiol ; 132: 109272, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32971326

RESUMO

PURPOSE: To report real-world diagnostic performance of chest x-ray (CXR) readings during the COVID-19 pandemic. METHODS: In this retrospective observational study we enrolled all patients presenting to the emergency department of a Milan-based university hospital from February 24th to April 8th 2020 who underwent nasopharyngeal swab for reverse transcriptase-polymerase chain reaction (RT-PCR) and anteroposterior bedside CXR within 12 h. A composite reference standard combining RT-PCR results with phone-call-based anamnesis was obtained. Radiologists were grouped by CXR reading experience (Group-1, >10 years; Group-2, <10 years), diagnostic performance indexes were calculated for each radiologist and for the two groups. RESULTS: Group-1 read 435 CXRs (77.0 % disease prevalence): sensitivity was 89.0 %, specificity 66.0 %, accuracy 83.7 %. Group-2 read 100 CXRs (73.0 % prevalence): sensitivity was 89.0 %, specificity 40.7 %, accuracy 76.0 %. During the first half of the outbreak (195 CXRs, 66.7 % disease prevalence), overall sensitivity was 80.8 %, specificity 67.7 %, accuracy 76.4 %, Group-1 sensitivity being similar to Group-2 (80.6 % versus 81.5 %, respectively) but higher specificity (74.0 % versus 46.7 %) and accuracy (78.4 % versus 69.0 %). During the second half (340 CXRs, 81.8 % prevalence), overall sensitivity increased to 92.8 %, specificity dropped to 53.2 %, accuracy increased to 85.6 %, this pattern mirrored in both groups, with decreased specificity (Group-1, 58.0 %; Group-2, 33.3 %) but increased sensitivity (92.7 % and 93.5 %) and accuracy (86.5 % and 81.0 %, respectively). CONCLUSIONS: Real-world CXR diagnostic performance during the COVID-19 pandemic showed overall high sensitivity with higher specificity for more experienced radiologists. The increase in accuracy over time strengthens CXR role as a first line examination in suspected COVID-19 patients.


Assuntos
Competência Clínica/estatística & dados numéricos , Infecções por Coronavirus/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Radiografia Torácica/métodos , Betacoronavirus , COVID-19 , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pandemias , Radiografia Torácica/normas , Radiologistas/normas , Reprodutibilidade dos Testes , Estudos Retrospectivos , SARS-CoV-2 , Sensibilidade e Especificidade
4.
Eur Radiol Exp ; 4(1): 68, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33319321

RESUMO

BACKGROUND: Integration of imaging and clinical parameters could improve the stratification of COVID-19 patients on emergency department (ED) admission. We aimed to assess the extent of COVID-19 pulmonary abnormalities on chest x-ray (CXR) using a semiquantitative severity score, correlating it with clinical data and testing its interobserver agreement. METHODS: From February 22 to April 8, 2020, 926 consecutive patients referring to ED of two institutions in Northern Italy for suspected SARS-CoV-2 infection were reviewed. Patients with reverse transcriptase-polymerase chain reaction positive for SARS-CoV-2 and CXR images on ED admission were included (295 patients, median age 69 years, 199 males). Five readers independently and blindly reviewed all CXRs, rating pulmonary parenchymal involvement using a 0-3 semiquantitative score in 1-point increments on 6 lung zones (range 0-18). Interobserver agreement was assessed with weighted Cohen's κ, correlations between median CXR score and clinical data with Spearman's ρ, and the Mann-Whitney U test. RESULTS: Median score showed negative correlation with SpO2 (ρ = -0.242, p < 0.001), positive correlation with white cell count (ρ = 0.277, p < 0.001), lactate dehydrogenase (ρ = 0.308, p < 0.001), and C-reactive protein (ρ = 0.367, p < 0.001), being significantly higher in subsequently dead patients (p = 0.003). Considering overall scores, readers' pairings yielded moderate (κ = 0.449, p < 0.001) to almost perfect interobserver agreement (κ = 0.872, p < 0.001), with better interobserver agreement between readers of centre 2 (up to κ = 0.872, p < 0.001) than centre 1 (κ = 0.764, p < 0.001). CONCLUSIONS: Proposed CXR pulmonary severity score in COVID-19 showed moderate to almost perfect interobserver agreement and significant but weak correlations with clinical parameters, potentially furthering CXR integration in patients' stratification.


Assuntos
COVID-19/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Radiografia Torácica/métodos , Idoso , Serviço Hospitalar de Emergência , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2 , Sensibilidade e Especificidade , Índice de Gravidade de Doença
5.
Invest Radiol ; 54(4): 191-197, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30379729

RESUMO

OBJECTIVE: This study compares the incidence of new-onset symptoms within 24 hours after enhanced magnetic resonance imaging (eMRI) with intravenous administration of gadodiamide or gadoterate meglumine compared with a control group undergoing unenhanced MRI (uMRI). MATERIALS AND METHODS: A prospective cohort study (n = 1088 patients) was designed to assess the incidence of symptoms within 24 hours after administration of gadodiamide or gadoterate meglumine. The participants underwent a structured questionnaire by phone call before and 24 hours after the MRI scan to check for symptoms that were not present before the scan. The questionnaire included a list of active questions aimed to test the prevalence of symptoms that have been proposed in the debated definition of gadolinium deposition disease (GDD) and that we recorded in this study as GDD-like. In particular, the following symptoms and signs were tested: central torso pain, arm or leg pain, bone pain, headache, skin redness (any site of the body), fatigue, and mental confusion.Fisher exact test was used to test differences between groups with significance threshold set at P < 0.05. RESULTS: Within the 24 hours after the MRI scan, 8.3% of patients reported at least one new-onset symptom in the uMRI group versus 17.4% in the gadodiamide eMRI versus 17.8% in the gadoterate meglumine eMRI group. The difference between the eMRI and the uMRI group was statistically significant (P < 0.001 for gadodiamide and P < 0.001 for gadoterate meglumine). There was not a different incidence of symptoms between the gadodiamide and the gadoterate meglumine eMRI groups. For gadodiamide, fatigue (P < 0.05) and dizziness (P < 0.05) were symptoms significantly more frequent than uMRI group; for gadoterate meglumine, fatigue (P < 0.01), mental confusion (P < 0.01), and diarrhea (P < 0.01) were significantly more frequent than uMRI group. CONCLUSIONS: We found that the onset of new symptoms within 24 hours after exposure to gadolinium-based contrast agent was more frequent than after uMRI. Among GDD-like symptoms, fatigue and mental confusion were the most frequent symptoms reported after eMRI. The other GDD-like symptoms were not overreported after eMRI versus uMRI. Thus, these results are questioning the term GDD.


Assuntos
Meios de Contraste/efeitos adversos , Gadolínio DTPA/efeitos adversos , Aumento da Imagem/métodos , Meglumina/efeitos adversos , Compostos Organometálicos/efeitos adversos , Inquéritos e Questionários/estatística & dados numéricos , Administração Intravenosa , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Incidência , Imageamento por Ressonância Magnética/métodos , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Estudos Prospectivos , Adulto Jovem
7.
Phys Med Biol ; 50(11): 2469-88, 2005 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-15901949

RESUMO

The first time-resolved optical mammograph operating beyond 900 nm was tested in a retrospective clinical study involving 194 patients with malignant and benign lesions, to investigate the diagnostic potential for the detection and characterization of breast lesions. For the first part of the study (101 patients with 114 lesions), the system was operated at 683, 785, 913 and 975 nm. Subsequently, to improve the spectral content of optical images, the number of wavelengths was increased (up to 7) and the spectral range was extended (637-985 nm). Late gated intensity and scattering images provide sensitivity to tissue composition (oxy- and deoxyhaemoglobin, water and lipids) and physiology (total haemoglobin content and oxygen saturation), as well as to structural changes. Tumours are typically identified because of the strong blood absorption at short wavelengths (637-685 nm), while cysts are characterized by low scattering, leading to a detection rate of approximately 80% for both lesion types, when detection is required in both cranio-caudal and oblique views. The detection rate for other benign lesions, such as fibroadenomas, is presently much lower (<40%). The effectiveness of the technique in localizing and identifying different lesion types was analysed as a function of various parameters (lesion size, compressed breast thickness, age, body mass index, breast parenchymal pattern). The possibility that physiologic changes due to the development of a malignant lesion could affect the entire breast was investigated. The capacity to assess the density of breast based on the average scattering properties was also tested.


Assuntos
Doenças Mamárias/diagnóstico , Cisto Mamário/diagnóstico , Neoplasias da Mama/diagnóstico , Ensaios Clínicos como Assunto , Feminino , Fibroadenoma/diagnóstico , Doença da Mama Fibrocística/diagnóstico , Humanos , Processamento de Imagem Assistida por Computador , Estudos Retrospectivos , Tomografia Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA