Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neoplasma ; 64(6): 954-961, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28895416

RESUMO

Current guidelines for follow-up after resection of colorectal cancer (CRC) recommend regular measurements of carcinoembryogenic antigen (CEA) and imaging tests. Multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) are currently primary imaging modalities, while the role of fluorine-18-fluoro-deoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), which is recommended in patients with negative MDCT and increased CEA, is still uncertain. Our aim was to compare diagnostic performance and prognostic significance of 18F-FDG PET/CT with MRI and tumor markers CEA and carbohydrate antigen 19-9 (CA 19-9) in detection of recurrent CRC. This prospective study included 35 patients with resected CRC, referred to 18F-FDG PET/CT examination for suspected recurrence. During median follow-up of 24.4±1.5 months 18F-FDG PET/CT and MRI results and tumor marker levels were compared with findings of histopathological examination or with results of clinical and imaging follow-up. Management plan before the 18F-FDG PET/CT scan was considered and compared to the final treatment decision. The sensitivity, specificity, positive and negative predictive value and accuracy of 18F-FDG PET/CT and MRI in detection of recurrent colorectal cancer in patient-based analysis were 92.6%, 75%, 92.6%, 75% and 88.6%, and 65.4%, 66.7%, 85%, 40% and 65.7%, respectively. In lesion-based analysis the sensitivity of 18F-FDG PET/CT and MRI was 83.1% and 68.2%, respectively. The overall accuracy of CEA and CA 19-9 in recurrence detection was 48.6% and 54.3%, respectively. PET/CT induced therapy alterations in 13/35 (37.1%) patients. Progression was observed in 16/35 patients during follow-up, with significantly lower risk of progression in patients with treatment changes based on PET findings (Multivariate Cox regression; p=0.017). In addition, elevated CA 19-9 levels in time of PET scan and male gender carried significantly higher risk of progression (p=0.007 and p=0.016, respectively). Kaplan-Meier Log rank test showed significantly longer progression-free survival time in patients who had treatment plan changed based on PET/CT (p=0.046). We can conclude that 18F-FDG PET/CT showed better sensitivity and accuracy compared to MRI in detection of recurrent colorectal cancer, with much better sensitivity compared to CEA and CA 19-9. Patients with treatment changes based on 18F-FDG PET/CT had significantly better prognosis and longer progression-free survival, while elevated values of CA 19-9 and male gender were associated with worse prognosis.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Biomarcadores Tumorais/análise , Antígeno CA-19-9/análise , Antígeno Carcinoembrionário/análise , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Recidiva Local de Neoplasia , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
2.
Neoplasma ; 63(2): 313-21, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26774154

RESUMO

Higher intensity of FDG uptake on PET/CT in primary tumor is seen in patients with IDC compared to ILC, also in high grade tumours, tumours with negative ER and higher Ki67 values, while data are inconsistent in case of relation between primary tumor's PgR and HER2 expression with its metabolic activity levels. On account of the lack of studies that include research of breast cancer metastatic lesion metabolism level and its relation to tumor histology and biology, our goal was to investigate the association of metastatic lesions' glucose metabolism level on PET/CT with different histological and biological characteristics of primary tumor. In a total number of N=100 patients, highest SUVmax values for each patient were used in testing difference between metastatic metabolic activity in patients with different tumor histology, grade, ER, PgR and HER2 status, subtype, as well in testing relation of Ki67 index to metastasis' metabolism level. In testing difference between histological types of breast cancer, SUVmax values were also compared separately for each specific anatomical site (regional and distant lymph nodes, bones and liver). No difference was found regarding metastatic SUVmax values in patients with primary IDC (n=55, median SUVmax 9.70) and ILC (n=34, median SUVmax 7.20) independently of anatomic site, and for each of analysed sites separately. No difference was found as well between SUVmax detected in metastasis in patients with different grade (grade II: n=58, median SUVmax 7.70; grade III: n=12, median SUVmax 10.20), ER (59 positive, median SUVmax 8.50; 22 negative, median SUVmax 8.05), PgR (55 positive, median SUVmax 8.50; 23 negative, median SUVmax 7.80), and HER2 (14 positive, median SUVmax 6.84; 51 negative, median SUVmax 8.63) expression in primary tumor, and between patients with different tumor subtype. Ki67 was also not associated with tumor metastatic SUVmax values (n=11, rs = -0.21, p=0.53). We conclude that there is no association of primary breast cancer histological type, grade, ER, PgR, HER2 and Ki67 expression with metabolic activity in metastasis detected on PET/CT.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Metabolismo Energético/fisiologia , Fluordesoxiglucose F18/metabolismo , Glucose/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/metabolismo , Neoplasias Ósseas/metabolismo , Neoplasias Ósseas/secundário , Feminino , Humanos , Antígeno Ki-67/metabolismo , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/secundário , Linfonodos/metabolismo , Metástase Linfática/patologia , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Receptor ErbB-2/metabolismo , Receptores de Estrogênio/metabolismo , Receptores de Progesterona/metabolismo
3.
Neoplasma ; 62(3): 449-55, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25866225

RESUMO

Neuroblastoma is the most common malignancy in children comprising 7.6% of all infantile cancers. MIBG scintigraphy is a mandatory neuroblastoma diagnostic test, which is among others methods, semi-quantified by the SIOPEN method. The aim of this study was to test both the skeletal and the soft tissue segments of the SIOPEN scoring method in the diagnostic milieu and to correlate them with the Curie score. Since there is little knowledge of their diagnostic power, the following variables were tested: VMA, HVA, LDH, and MYCN, ferritin, bone marrow infiltration, the INSS and the INPC classification. The cross-sectional study with repeated measurements of 143 scintigrams was performed on 76 pediatric patients with suspected or proven neuroblastoma, who had been referred to the Center for Nuclear Medicine of the Clinical Center of Serbia in the period 2007-2012. The range of the SIOPEN soft tissue scores was 0-5. The range of the SIOPEN skeletal scores was 0-57. The range of the Curie scores was 0-26. The skeletal SIOPEN scores were significantly higher in bone marrow positive children, in children with pathologically elevated urinary VMA levels and in children having a more advanced clinical stage. There was no difference in the SIOPEN soft tissue score due to higher VMA levels, or depending on the clinical stage and positive bone marrow assessment. There was no difference between the SIOPEN skeletal and soft tissue scores on one hand and the histological grade of the tumor; elevated or normal levels of HVA, LDH, NSE and ferritin, or the presence or absence of MYNC amplification in the neuroblastoma cell line, on the other hand. The results of both SIOPEN scores showed a high linear correlation with the Curie score. The conclusion is that the soft tissue segment of the SIOPEN score needs further elucidation in a more controlled milieu. Excellent correlation between all segments of the two semi-quantitative scoring methods speaks in favor of the application of the complete SIOPEN scoring system in every day mIBG scanning.

4.
Neoplasma ; 62(2): 295-301, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25591595

RESUMO

UNLABELLED: Multi-detector computed tomography (MDCT) is most commonly used for staging of non-small cell lung cancer (NSCLC). In recent years, 18F- fluorodeoxyglucose positron emission tomography combined with computed tomography (18F-FDG PET/CT) has also been used for the same purpose. Since studies comparing these two methods are scarce, our aim was to determine how the TNM classification and thereby staging of NSCLC compare between 18F-FDG PET/CT and MDCT. 18F-FDG PET/CT and MDCT were collected in 83 patients with NSCLC 3 to 30 days apart (median 17 days). The investigators interpreting 18F-FDG PET/CT were unaware of MDCT results. The Cohen's kappa (κ) was calculated to determine the rate of agreement. The hypothesis was that the strength of agreement between the two methods will be at least moderate (κ>0.40) based on the adopted criteria (κ<0.20 poor; 0.21-0.40 fair; 0.41-0.60 moderate; 0.61-0.80 good; 0.81-1.00 very good agreement). The agreement was moderate for determining the T class (κ=0.45, overall agreement 58%), poor for the N class (κ=0.13, 42%) and fair for the M class (κ=0.22, 58%). The agreement for overall staging of NSCLC was poor (κ=0.20, 45%). The major source of disagreement was that metastases were present more frequently and/or in larger number on 18F-FDG PET/CT than MDCT in the contralateral mediastinal, supraclavicular, and distant lymph nodes, as well as in the bones and suprarenal glands. Since 18F-FDG PET/CT detected more regional and distant metastases than MDCT, we conclude that FDG PET/CT is useful for staging/restaging and planning treatment of patients with NSCLC. KEYWORDS: Non-small cell lung cancer, positron emission tomography, multidetector computed tomography, metastases detection.

5.
J BUON ; 17(3): 537-42, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23033296

RESUMO

PURPOSE: To assess the value of whole body scintigraphy using (99m)Tc-HYNIC-TOC (Tektrotyd) and with single photon emission computerized tomography (SPECT) in the detection of primary and metastatic neuroendocrine tumors (NETs). METHODS: Thirty patients with different neuroendocrine tumors, mainly gastroenteropancreatic (GEP), were investigated. Whole body scintigraphy was performed 2 h (if necessary 10 min and 24h) after i.v. administration of 740 Mbq (99m)Tc-Tektrotyd, Polatom. In cases of unclear findings obtained by whole body scintigraphy, investigation was followed by SPECT. RESULTS: From 12 patients with NETs of unknown origin, there were 10 true positive (TP), and 2 false negative (FN) findings. Diagnosis was made with SPECT in 6 patients. From 8 patients with gut carcinoids, there were 4 TP, 2 true negative (TN), one FN, and one false positive (FP) finding. Diagnosis was made with SPECT in 2 patients. From 7 patients with neuroendocrine pancreatic carcinomas there were 4 TP and 3 TN findings. Diagnosis was made with SPECT in 2 patients. From 3 patients with gastrinomas there were 2 TP findings and one TN findings. Diagnosis was made with SPECT findings in 2 patients. Sensitivity of (99m)Tc-HYNIC-TOC was 87%, specificity 86%, positive predictive value 95%, negative predictive value 67% and accuracy 87%. CONCLUSION: We concluded that scintigraphy with (99m)Tc-Tektrotyd is an useful method for diagnosis, staging and follow up of the patients with NETs.


Assuntos
Tumores Neuroendócrinos/diagnóstico por imagem , Octreotida/análogos & derivados , Compostos de Organotecnécio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tumores Neuroendócrinos/patologia
6.
J BUON ; 17(4): 695-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23335527

RESUMO

PURPOSE: The aim of this study was to evaluate the clinical reliability of the immunoscintigraphy with iodinated monoclonal antibodies for the detection of metastases and recurrences of colon carcinomas. METHODS: A total of 45 patients with colon carcinoma was investigated with gamma camera, after intravenous application of iodinated monoclonal antibodies. RESULTS: The sensitivity of the method was 90%, specificity 86%, positive predictive value 93%, negative predictive value 80% and accuracy 87%. There was statistically significant relationship between immunoscintigraphic and ultrasonographic (US) findings (p=0.005). Also, there was significant relationship between immunoscintigraphy and Dukes stage (p=0.019). Tumor marker levels were not significantly correlated with immunoscintigraphic findings (p<0.05). Significant difference was noted in patients with positive findings for malignancy on US and immunoscintigraphic findings (p=0.006), i.e. patients with positive findings for malignancy had more frequently immunoscintigraphic findings of malignancy. Correlation with other diagnostic procedures (rectoscopy, colonoscopy, CT) did not show significant correlations. CONCLUSION: We conclude that immunoscintigraphy can be helpful in the detection of metastases and recurrences of colon carcinomas.


Assuntos
Neoplasias do Colo/diagnóstico por imagem , Radioisótopos do Iodo , Radioimunodetecção/métodos , Adulto , Idoso , Anticorpos Monoclonais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Neoplasma ; 57(1): 68-73, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19895175

RESUMO

UNLABELLED: Our aim was to assess clinical utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for evaluation of lung lesions in patients with neuroendocrine tumors (NETs). Single photon emission computed tomography (SPECT) of the thorax and whole body scintigraphy were performed in 34 patients using 99mTc-EDDA/HYNIC-TOC. Visual assessment was complemented by semiquantitative evaluation based on tumor to non-tumor (T/NT) ratio. Clinical, laboratory, and histological findings served as the standard for comparison. Enhanced tracer uptake was observed on both SPECT and whole body scintigraphy in 29 of 34 patients (88% sensitivity). T/NT ratios were significantly higher on SPECT than whole body images (2.96+/-1.07 vs.1.70+/-0.43, p KEYWORDS: 99mTc-EDDA/Hynic-TOC, lung involvement of NETs, T/NT ratio.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Tumores Neuroendócrinos/diagnóstico por imagem , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Proliferação de Células , Feminino , Humanos , Antígeno Ki-67/análise , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/patologia , Tumores Neuroendócrinos/radioterapia , Imagem Corporal Total
8.
Neoplasma ; 56(1): 1-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19152238

RESUMO

Immunoscintigraphy combines the advances in immunology and nuclear medicine to target tumor sites. Visualization of colorectal carcinomas is based on different monoclonal antibodies and their fragments against tumor-associated antigens labeled with gamma emitting radionuclides which accumulate in the tumor tissue due to their interaction with corresponding antigens. Available data on the role of immunoscintigraphy in detection of recurrence and metastases of colorectal carcinomas are reviewed. Despite a variety of investigations related to the application of immunoscintigraphy in diagnostics of colorectal cancer, using different radiolabeled immunoreactive agents and imaging methods there has not been a consensus among the investigators regarding the best modality of the method, including the specific radiopharmaceutical for this purpose. Some general conclusions concerning potentials of immunoscintigraphy in such diagnostics, including expectancy of the newly developed SPECT/CT systems, are suggested. The possibilities of PET imaging of colorectal carcinomas using monoclonal antibodies labeled with positron emitting radionuclides, as well as of the radioimmunoguided surgery and radioimmunotherapy are also discussed. Key words: Immunoscintigraphy, colorectal cancer, recurrences, metastases, radioimmunoguided surgery, SPECT/CT.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Radioimunodetecção/métodos , Cintilografia/métodos , Anticorpos Monoclonais , Humanos , Compostos Radiofarmacêuticos
9.
Neoplasma ; 53(5): 444-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17013541

RESUMO

The aim of the study was evaluation of the clinical reliability of the immunoscintigraphy for the detection of metastases and recurrences of colorectal carcinomas using three different radiopharmaceutical substances. With IMACIS 1, the number of true negative findings (TN) was 4/7 and true positive (TP) 3/7, while in one patient, the results of immunoscintigraphy significantly influenced the therapeutical management. With INDIMACIS 19-9, there were 2/8 TN and 6/8 TP. In three patients, immunoscintigraphy results influenced patient further management. With ONCOSCINT in 2 patients findings were TN, in one FN and in one FP. In 3 patients, immunoscintigraphy influenced the management of the patient. Other imaging methods (CT, US, MRI) have advantage in detection of liver metastases, while immunoscintigraphy is more specific for the assessment of reccurences of the abdominal tumors. Thus immunoscintigraphy should be applied in patients with suggested recurrences and inconclusive outcome of routine diagnostic workup.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico por imagem , Metástase Neoplásica/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Radioimunodetecção/métodos , Compostos Radiofarmacêuticos , Anticorpos Monoclonais , Humanos , Radioisótopos de Índio , Sensibilidade e Especificidade
10.
Hepatogastroenterology ; 52(62): 491-5, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15816464

RESUMO

BACKGROUND/AIMS: The aim of the study is detection and evaluation of the abdominal and gastrointestinal infective foci using 99mTc-ciprofloxacin (Laboratory for radioactive isotopes, Vinca). METHODOLOGY: In total 21 patients with clinical suspicion on abdominal or gastrointestinal infection were investigated. In all the patients, planar liver/spleen scintigraphy was performed. Ciprofloxacin chloride (3.5 mg) was mixed with 555 MBq of 99mTc in 3 mL of physiological solution and incubated for 20 min. After slow i.v. injection in a cubital vein, dynamic acquisition (1 f/min) was performed during the first 60 min in the position of interest, followed by static acquisition (500,000 imp) anterior and posterior view, abdomen and pelvis after 1 h and 4 h in all patients. When necessary, additional scintigrams were acquired after 24 h. In all the patients with negative or equivocal findings of planar scintigraphy, emission computerized tomography (SPECT) was performed (60 positions, 6 degrees). Interpretation was made by three independent observers. Additional data were provided using clinical findings, ultrasonography, computed tomography and magnetic resonance imaging, laboratory analyses, and surgical or microbiological confirmation of infection. RESULTS: There were eleven true-positive findings, seven true negative, two were false negative while one was false positive due to intestinal obstruction. Sensitivity was 79%, specificity 91%, positive predictive value 92%, negative predictive value 77%, accuracy 84%. CONCLUSIONS: According to our results, scintigraphy with radiolabeled ciprofloxacin is a useful method for detection and assessment of exact localization of abdominal and gastrointestinal infections.


Assuntos
Abdome/diagnóstico por imagem , Infecções Bacterianas/diagnóstico por imagem , Ciprofloxacina/análogos & derivados , Gastroenteropatias/diagnóstico por imagem , Compostos de Organotecnécio , Infecções Bacterianas/metabolismo , Ciprofloxacina/farmacocinética , Reações Falso-Negativas , Reações Falso-Positivas , Gastroenteropatias/metabolismo , Humanos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Compostos de Organotecnécio/farmacocinética , Valor Preditivo dos Testes , Cintilografia , Sensibilidade e Especificidade , Baço/diagnóstico por imagem , Baço/metabolismo , Distribuição Tecidual
11.
Eur J Radiol ; 84(3): 350-359, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25579474

RESUMO

PURPOSE: Standardized perfusion value (SPV) is a universal indicator of tissue perfusion, normalized to the whole-body perfusion, which was proposed to simplify, unify and allow the interchangeability among the perfusion measurements and comparison between the tumor perfusion and metabolism. The aims of our study were to assess the standardized perfusion value (SPV) of the esophageal carcinoma, and its correlation with quantitative CT perfusion measurements: blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) of the same tumor volume samples, which were obtained by deconvolution-based CT perfusion analysis. METHODS: Forty CT perfusion studies of the esophageal cancer were analyzed, using the commercial deconvolution-based CT perfusion software (Perfusion 3.0, GE Healthcare). The SPV of the esophageal tumor and neighboring skeletal muscle were correlated with the corresponding mean tumor and muscle quantitative CT perfusion parameter values, using Spearman's rank correlation coefficient (rS). RESULTS: Median SPV of the esophageal carcinoma (7.1; range: 2.8-13.4) significantly differed from the SPV of the skeletal muscle (median: 1.0; range: 0.4-2.4), (Z=-5.511, p<0.001). The cut-off value of the SPV of 2.5 enabled discrimination of esophageal cancer from the skeletal muscle with sensitivity and specificity of 100%. SPV of the esophageal carcinoma significantly correlated with corresponding tumor BF (rS=0.484, p=0.002), BV (rS=0.637, p<0.001) and PS (rS=0.432, p=0.005), and SPV of the skeletal muscle significantly correlated with corresponding muscle BF (rS=0.573, p<0.001), BV (rS=0.849, p<0.001) and PS (rS=0.761, p<0.001). CONCLUSIONS: We presented a database of the SPV for the esophageal cancer and proved that SPV of the esophageal neoplasm significantly differs from the SPV of the skeletal muscle, which represented a sample of healthy tissue. The SPV was validated against quantitative CT perfusion measurements and statistically significant correlation was proved.


Assuntos
Neoplasias Esofágicas/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Imagem de Perfusão , Tomografia Computadorizada por Raios X , Volume Sanguíneo , Neoplasias Esofágicas/complicações , Neoplasias Esofágicas/patologia , Humanos , Masculino , Perfusão , Imagem de Perfusão/métodos , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Hepatogastroenterology ; 46(26): 1234-7, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10370698

RESUMO

The aim of the study is assessment of the relationship between enterogastric reflux and the presence of Helicobacter pylori infection as factors that cause gastritis, peptic ulcer and adenocarcinoma ventriculi. The study was performed in 52 patients with different digestive disorders, using gamma camera, during 90 min (1 frame/min) after intravenous injection of 185 MBq 99mTc-dietil IDA in the cubital vein. According to time/activity curves from the region of hepatobiliary system and stomach, index of enterogastric reflux (EGR) was assessed. There was no correlation between the presence of Helicobacter pylori and EGR (r = 0.181, df = 52, p > 0.05). However, Helicobacter pylori was present more frequently in the patients with positive EGR (p < 0.01), but there were no significant differences (p > 0.05) in reflux value in patients with either positive or negative findings of Helicobacter pylori.


Assuntos
Refluxo Duodenogástrico/diagnóstico por imagem , Infecções por Helicobacter/diagnóstico por imagem , Helicobacter pylori , Adulto , Idoso , Refluxo Duodenogástrico/microbiologia , Feminino , Infecções por Helicobacter/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Fatores de Risco
13.
Hepatogastroenterology ; 47(33): 738-41, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10919022

RESUMO

BACKGROUND/AIMS: The aim of the study was to introduce the chosen and modified model of the nuclear medicine method for the detection and quantification of enterogastric reflux, as well as evaluation of its clinical validity. METHODOLOGY: The study was performed in 172 patients: with gastric and duodenal ulcer, after Billroth I and Billroth II gastrectomy, with gastroesophageal reflux, after cholecystectomy, with chronic cholecystitis and chronic duodenal disease. Acquisition was performed with a gamma camera, during 90 min after intravenous application of 185MBq 99mTc-Dietil IDA. Test meal was given in the 30th minute, while the gastric region was marked at the end of the study. On the basis of the radioactivity changes in the regions of the stomach and hepatobiliary system, the presence of enterogastric reflux was determined and its index calculated. RESULTS: In all the groups of patients, values were significantly higher than in the controls (P < 0.05). The most frequent occurrence and the largest quantity of reflux was present in patients after Billroth II gastrectomy with significantly different values from other groups of patients (P < 0.05). CONCLUSIONS: The obtained results approve clinical value of the chosen and modified scintigraphy of enterogastric reflux, as a non-invasive and physiological method, which provides exact data about its presence and quantity.


Assuntos
Úlcera Duodenal/diagnóstico por imagem , Refluxo Gastroesofágico/diagnóstico por imagem , Úlcera Gástrica/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Sistema Biliar/diagnóstico por imagem , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Cintilografia/métodos
14.
Hepatogastroenterology ; 50(52): 1029-31, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12845972

RESUMO

BACKGROUND/AIMS: The aim of the study is detection of the recurrences and metastases of colorectal carcinomas using 111In-labeled antibodies B72.3. METHODOLOGY: Fourteen patients underwent planar immunoscintigraphy and/or tomoscintigraphy. RESULTS: With tomography in comparison to planar scintigraphy, we can access better distinction of tumor and estimation of its size. Other imaging methods (computed tomography, ultrasonography) have an advantage in detection of liver metastases, while immunoscintigraphy is more specific for the assessment of malignant abdominal tumors and extrahepatic metastases. CONCLUSIONS: The first results point out that Oncoscint CR-103 can be useful in diagnosis of recurrences and metastases of colorectal carcinoma, viability assessment after radiotherapy and in the choice of the adequate surgical treatment in dependence of the spread of the disease.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Anticorpos Monoclonais , Neoplasias Colorretais/diagnóstico por imagem , Radioisótopos de Índio , Recidiva Local de Neoplasia/diagnóstico por imagem , Oligopeptídeos , Ácido Pentético/análogos & derivados , Radioimunodetecção , Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias Colorretais/patologia , Humanos , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/secundário
15.
Nucl Med Rev Cent East Eur ; 3(1): 53-6, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-14600981

RESUMO

BACKGROUND: The purpose of this study was to investigate bladder function parameters by means of quantitative radionuclide cystography (QRC) in anxious, irritable children with unstable bladder. METHODS: Quantitative radionuclide cystography was performed in 18 children aged between 8 and 12 years, without evidence of neurologic and nephrologic disorders. Findings were compared with those obtained in 10 healthy children aged between 7 and 10 years. The dynamics of the bladder emptying were studied after intravenous injection of 37 MBq/10 kg b.w. 99mTc-diethylenetriaminepentaacetic acid (DTPA) in the posterior views. Images of 90 frames every 2 sec. were stored in the 64 x 64 computer matrix during voiding. The patients voided into a container and the volumes were measured. RESULTS: The parameters evaluated were: functional bladder capacity (ml)--FBC, expected bladder capacity (ml)--EBC, percentage of EBC (%), voided urine volume (ml)--VV, residual urine (ml)--RU, voiding time (sec)--VT, average flow rate (ml/sec)--AFR and peak flow rate (ml/sec)--PFR. There was a statistically significant difference between controls and children with unstable bladder in the following parameters: FBC 288 +/- 33 vs. 244 +/- 27 ml (p < 0.001), % of EBC 99 +/- 6 vs. 82 +/- 6% (p < 0.0001), VV 265 +/- 37 vs. 202 +/- 35 ml (p < 0.0001), RU 22 +/- 11 vs. 48 +/- 19 ml (p < 0.007), AFR 13 +/- 5 ml/sec vs. 9 +/- 4 ml/sec. (p < 0.01) and PFR 19 +/- 2 vs. 13 +/- 3 ml/s (p < 0.0001), respectively. The VT obtained from the control group of 23 +/- 9 s did not differ significantly from the value of children with unstable bladder of 28 +/- 14 s. CONCLUSION: The results show that quantitative radionuclide cystography is a simple, noninvasive method, which allows a good separation of patients with unstable bladder from the children with normal voiding pattern.

16.
Nucl Med Rev Cent East Eur ; 4(2): 113-5, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-14600897

RESUMO

A 62-year-old patient presented with flatulence, abdominal distension and other symptoms of ileus. Roentgenographic finding found compression on duodenum. Blood pool scintigraphy ((99m)Tc erythrocytes) showed aortal aneurysm, while simultaneous gastric emptying study with liquid meal ((99m)Tc-S-colloid) showed dislocation of duodenum and compression from abdominal aortal aneurysm.

17.
Nucl Med Rev Cent East Eur ; 1(1): 2-5, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-14601001

RESUMO

BACKGROUND: The aim of the study is to evaluate gallbladder (GB) motor function, by infusion cholescintigraphy, in patients after total gastrectomy (Roux-en-Y) with expected disturbances in the physiological regulation of biliary tract motility. METHODS: The study was done in 10 controls, as well as in 12 patients early (less than 2 months) and in 14 late (6 months-2 years) after surgery. Anterior abdominal imaging by gamma camera and computer acquisition was performed during three-hours infusion of 150 MBq, preceded by the loading dose of 50 MBq of 99mTc-EHIDA in bolus injection. The test meal stimulation was done in the 120th min of the study. GB TA curve was obtained and five parameters of GB motility were analysed: durations of filling (ascending) and emptying (descending) phases, filling and emptying rate ratio and ejection fraction and rate. RESULTS: Our results have shown that in the early period after the operation GB filling is prolonged and emptying impaired, while after several months GB motor function is normalised. CONCLUSIONS: It can be concluded that the infusion cholescintigraphy is potentially useful in patients after such surgery to decide on the specific treatment introduction in order to prevent GB calculosis and other complications.

18.
Nucl Med Rev Cent East Eur ; 4(2): 101-3, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-14600894

RESUMO

Helicobacter pylori infection is supposed to be one of the major causes of digestive and other diseases. Among a lot of invasive and non-invasive methods for its detection, none is ideal. The aim is an assessment of the Helicobacter pylori infection in the stomach using breath test and comparison to other diagnostic methods, as well as following up the effects of therapy. In 17 patients with digestive discomfort, breath test, rapid urease test and histology were performed, while in 47 patients with proven HP infection the effect of therapy was followed up using breath test and clinical findings. Breath test was performed after per oral administration of the capsule of (14)C urea (37 kBq). Findings of the breath and urease tests were in accordance in 14/17 patients (83%) while breath test and histology in 16/17 patients (94%). During follow-up of the therapeutic effects, breath test and clinical findings were in accordance in 43/47 patients (98%). Breath test can be useful in diagnosis but is a method of choice in following up the patients after therapy for H. pylori infection, because it is non-invasive, fast and precise.

19.
Acta Chir Iugosl ; 55(1): 11-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18510056

RESUMO

The aim of this study is the assessment of the relative arterial and venous contribution to the total liver blood flow (hepatic perfusion index-HPI), with two methods (S1 and S2), and estimation of their value. With this correction, HPI nonsignificantly increases (p>0.05) in all the groups of patients, with a very high correlation between the HPI (S1) and HPI (S2) values (p<0.01). In comparison to the portal perfusion in controls, values were significantly (p<0.01) lower in chronic active hepatitis and liver cirrhosis and differed between themselves (p<0.01). In the groups of cirrhotic patients with esophageal varices, sclerosated esophageal varices, recanalized umbilical vein, portal thrombosis and cavernous portal vein, portal perfusion was lower (p<0.01) than in controls, chronic active hepatitis and liver cirrhosis without collaterals. Both angioscintigraphic methods are useful for the estimation of the disturbances in the portal system. Because of the more exact estimation of the liver perfusion, S2 is recommended.


Assuntos
Circulação Hepática , Sistema Porta/diagnóstico por imagem , Varizes Esofágicas e Gástricas/etiologia , Varizes Esofágicas e Gástricas/fisiopatologia , Hepatite Crônica/complicações , Hepatite Crônica/diagnóstico por imagem , Hepatite Crônica/fisiopatologia , Humanos , Hipertensão Portal/diagnóstico por imagem , Hipertensão Portal/etiologia , Hipertensão Portal/fisiopatologia , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/fisiopatologia , Angiografia Cintilográfica , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/fisiopatologia
20.
Acta Chir Iugosl ; 53(1): 23-7, 2006.
Artigo em Sr | MEDLINE | ID: mdl-16989142

RESUMO

The aim of the study is evaluation of hepatocellular function, as well as morphology and patency of the biliary three of the liver transplants by dynamic hepatobiliary scintigraphy. The study was performed in 10 controls and 10 patients after orthotopic transplantation (up to two years). Sixty minutes dynamic acquisition (1 frame/min) was performed with scintillation camera after injection of 360 MBq 99mTc-diethyl- IDA. Hepatobiliary scintigrams were analysed for morphology, and parenchymal and hepatobiliary TA curves were generated and analysed as regard to the time to maximal acitivity (Tmax) and the time to half of maximum acitivity (T1/2). Uptake of the radiopharmaceutical was slightly but not significantly delayed (Tmax=18.5 +/- 2.9 min) in comparison to the controls (Tmax=14.2 +/- 3.4min), while excretion was significantly prolonged (T1/2=59.5 +/- 12.1 min) than physiological (Tmax=34.2 +/- 4.1min). Intrahepatic bile flow was nonsignificantly prolonged (Tmax=31.3 +/- 3.7 min) in comparison to the controls (Tmax=25.7 +/- 3.5 min) while extrahepatic one is high significantly prolonged (T1/2=89.0 +/- 14.3 min) than physiological (T1/2 =45.0 +/- 7.2 min). Biliary phase of hepatobiliary scintigraphy showed increased accumulation of radiopharmaceutical in the left (n=1) or right (n=2) hepatic duct. Radionuclide methods are noninvasive, and apear to be sensitive and valuable for the monitoring of liver transplants.


Assuntos
Sistema Biliar/diagnóstico por imagem , Transplante de Fígado/diagnóstico por imagem , Fígado/diagnóstico por imagem , Humanos , Fígado/fisiopatologia , Cintilografia , Compostos Radiofarmacêuticos , Ácido Dietil-Iminodiacético Tecnécio Tc 99m
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA