Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Rev Mal Respir ; 30(1): 77-80, 2013 Jan.
Artigo em Francês | MEDLINE | ID: mdl-23318194

RESUMO

INTRODUCTION: Acute respiratory distress syndrome caused by Mycoplasma pneumoniae infection has rarely been described. OBSERVATION: We report a case of community-acquired pneumonia occurring in a patient with Down's syndrome. Persisting hypoxemia raised the questions of nosocomial pneumonia, of the occurrence of a fibrosing alveolitis or of the resistance of the strain to macrolides. After a long period of very severe respiratory impairment, the evolution was progressively favourable and the patient was discharged from ICU with full respiratory recovery 43 days after admission. CONCLUSION: Acute respiratory distress syndrome caused by M. pneumoniae infection is rare but must be considered when the appropriate clinical and radiological pattern occurs. The question of the susceptibility of the strain to macrolides has to be raised in some circumstances.


Assuntos
Resistência Microbiana a Medicamentos , Pneumonia por Mycoplasma/complicações , Síndrome do Desconforto Respiratório/etiologia , Adulto , Infecções Comunitárias Adquiridas/complicações , Infecções Comunitárias Adquiridas/diagnóstico , Infecções Comunitárias Adquiridas/diagnóstico por imagem , Síndrome de Down/complicações , Síndrome de Down/diagnóstico por imagem , Resistência Microbiana a Medicamentos/fisiologia , Feminino , Humanos , Unidades de Terapia Intensiva , Mycoplasma pneumoniae/fisiologia , Pneumonia por Mycoplasma/diagnóstico , Pneumonia por Mycoplasma/diagnóstico por imagem , Radiografia Torácica , Síndrome do Desconforto Respiratório/diagnóstico , Síndrome do Desconforto Respiratório/diagnóstico por imagem
2.
Ann Fr Anesth Reanim ; 29(5): 347-53, 2010 May.
Artigo em Francês | MEDLINE | ID: mdl-20347564

RESUMO

INTRODUCTION: We have prospectively compared simulated-difficult tracheal intubation characteristics of four glottiscopes: Airtraq, GlideScope, McGrath, LMA CTrach with that of the conventional Macintosh laryngoscope. STUDY DESIGN: prospective with the airway devices proposed in a randomly assigned order. MATERIALS AND METHOD: Forty-two physicians, naïve to glottiscope handling accepted participating this study after the learning curve of each airway device was completed. Participants were requested to perform two series of five tracheal intubations on the manikin Airman, the first in standard situation and the second in difficult tracheal intubation simulation. The airway devices were chosen in a randomly assigned order. For each airway tool, the following tracheal intubation characteristics were recorded: laryngeal exposure quality, tracheal intubation and apnea durations. A performance index was calculated and a tracheal intubation difficulty was measured during simulation. RESULTS: More than 1600 supervised tracheal intubations were performed, including 1000 for the learning process of the glottiscopes, which was completed after 10 uses on the manikin. During standard situation, laryngeal exposure quality was similar with the five airway devices. As compared to the Macintosh laryngoscope, GlideScope, McGrath, tracheal intubation duration was shorter (p<0.05) with the Airtraq and longer (p<0.01) with the LMA CTrach. During difficult tracheal intubation simulation, laryngeal exposure and tracheal intubation duration was of better quality and shorter with the four glottiscopes as compared to that of LM, respectively. Performance index during difficult tracheal intubation simulation simulation was significantly more important (p<0.01) with the Airtraq and the LMA CTrach. Airtraq and Macintosh laryngoscope were respectively the simplest (p<0.01) and the most difficult (p<0.01) airway devices to manage a simulated difficult tracheal intubation. CONCLUSION: When difficult airway was simulated on the manikin, the four glottiscopes were superior to the Macintosh laryngoscope to improve laryngeal exposure quality and to reduce duration of tracheal intubation. Airtraq and the LMA CTrach both demonstrated remarkable advantage over GlideScope and McGrath for simulated difficult intubation management.


Assuntos
Glote , Intubação Intratraqueal/métodos , Laringoscópios , Manequins , Desenho de Equipamento , Humanos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA