Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 389(18): 1685-1692, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37913506

RESUMO

Two siblings presented with cardiomyopathy, hypertension, arrhythmia, and fibrosis of the left atrium. Each had a homozygous null variant in CORIN, the gene encoding atrial natriuretic peptide (ANP)-converting enzyme. A plasma sample obtained from one of the siblings had no detectable levels of corin or N-terminal pro-ANP but had elevated levels of B-type natriuretic peptide (BNP) and one of the two protein markers of fibrosis that we tested. These and other findings support the hypothesis that BNP cannot fully compensate for a lack of activation of the ANP pathway and that corin is critical to normal ANP activity, left atrial function, and cardiovascular homeostasis.


Assuntos
Arritmias Cardíacas , Cardiomiopatias , Átrios do Coração , Hipertensão , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Arritmias Cardíacas/metabolismo , Arritmias Cardíacas/patologia , Fibrilação Atrial , Fator Natriurético Atrial/sangue , Fator Natriurético Atrial/genética , Fator Natriurético Atrial/metabolismo , Cardiomiopatias/sangue , Cardiomiopatias/diagnóstico , Cardiomiopatias/genética , Cardiomiopatias/metabolismo , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/metabolismo , Átrios do Coração/patologia , Hipertensão/sangue , Hipertensão/genética , Hipertensão/metabolismo , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/genética , Peptídeo Natriurético Encefálico/metabolismo , Serina Endopeptidases/sangue , Serina Endopeptidases/genética , Serina Endopeptidases/metabolismo , Irmãos
2.
Acta Radiol ; 64(9): 2518-2525, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37448307

RESUMO

BACKGROUND: Pressure overload of the right heart (pulmonary hypertension [PH]) can be an acute or a chronic process with various pathophysiologic changes affecting the dimensions of the heart chambers. The automatic four-chamber volumetric analysis tool is now available to measure the volume of the cardiac chambers in patients undergoing a computed tomography pulmonary angiogram (CTPA). PURPOSE: To characterize the volumetric changes that occurred in response to increased systolic pulmonary arterial pressures (sPAP) in acute events, such as acute pulmonary embolism (APE), compared with other etiologies. MATERIAL AND METHODS: Consecutive patients who underwent CTPA and echocardiography within 24 h between 2011 and 2015 were included. Differences in cardiac chamber volumes were investigated in correlation to the patients' sPAP. RESULTS: The final cohort of 961 patients included 221 (23%) patients diagnosed with APE. The right (RV) to left (LV) ventricular volume ratio (VVR) was higher, while the left atrial (LA) volume index was smaller (P < 0.001) in the patients with APE. A decision tree for the prediction of APE showed that an RV to left VVR >2.8 was characteristic of APE, whereas an LA volume index >37.5 mL/m² was more compatible with PH due to other etiologies (P < 0.001). CONCLUSION: The combination of VVR and LA volume index may help in differentiating between APE and chronic PH. CTPA-based volumetric information may be used to help clarify the underlying etiology of the dyspnea.


Assuntos
Hominidae , Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Animais , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Algoritmos
3.
Emerg Radiol ; 30(2): 167-174, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36680669

RESUMO

INTRODUCTION: The reported yield of non-contrast computed tomography (NCCT) in assessing flank pain and obstructive urolithiasis (OU) in emergency departments (EDs) is only ~ 50%. We investigated the potential capability of serum and urinary markers to predict OU and improve the yield of NCCT in EDs. METHODS: All consecutive ED patients with acute flank pain suggestive of OU and assessed by NCCT between December 2019 and February 2020 were enrolled. Serum white blood cells (WBC), C-reactive protein (CRP) and creatinine (Cr) levels, and urine dipstick results were analyzed for association with OU, and unjustified NCCT scan rates were calculated. RESULTS: NCCTs diagnosed OU in 108 of the 200 study patients (54%). The median WBC, CRP, and Cr values were 9,100/µL, 4.3 mg/L, and 1 mg/dL, respectively. Using ROC curves, WBC = 10,000/µL and Cr = 0.95 mg/dl were the most accurate thresholds to predict OU. Only WBC ≥ 10,000/µL (OR = 3.7, 95% CI 1.6-8.3, p = 0.002) and Cr ≥ 0.95 mg/dl (OR = 5, 95% CI 2.3-11, p < 0.001) were associated with OU. Positive predictive value and specificity for detecting OU among patients with combined WBC ≥ 10,000 and Cr ≥ 0.95 were 83% and 89%, respectively. Patients negative to the serum markers criteria underwent significantly more unjustified NCCTs (p = 0.03). The negative predictive value of the serum criteria for justified NCCT scanning was 81%. CONCLUSIONS: WBC and Cr may be valuable serum markers in predicting OU among patients presenting to EDs with acute flank pain. They may potentially reduce the number of unjustified NCCT scans in the ED setting.


Assuntos
Dor Aguda , Cálculos Ureterais , Urolitíase , Humanos , Dor no Flanco/complicações , Cálculos Ureterais/diagnóstico por imagem , Cálculos Ureterais/complicações , Biomarcadores , Serviço Hospitalar de Emergência
4.
World J Urol ; 40(6): 1553-1560, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35366108

RESUMO

BACKGROUND: Computerized tomography (CT) is considered indispensable in percutaneous nephrolithotomy (PCNL) planning. We aimed to define the reliability of pre-PCNL CT for planning renal access by assessing renal positional changes between supine and prone CTs. SUBJECTS AND METHODS: CT urographies (CTU) of 30 consecutive patients were reviewed for distances upper pole (UP)-diaphragm, UP-diaphragm attachment, renal pelvis (RP)-lateral body wall, RP- posterior body wall, and lower pole (LP)- anterior-superior iliac spine (ASIS). The posterior and lateral renal axes angles were also calculated. RESULTS: The most consistent overall movement in transition from prone to supine was backward rotation, as demonstrated by a decrease in distance UP-posterior body wall (p = 0.010) and increase in the posterior renal angle (p < 0.0001). This finding correlated with the patient's body mass index (BMI) (p = 0.029). The left kidney was more mobile than the right one, moving significantly for five of the measured parameters compared to the right kidney which moved significantly for only two parameters. The UP-diaphragm distance of the left kidney correlated with age (p = 0.014), the RP-lateral wall distance correlated with previous abdominal surgery (p = 0.006), and the RP-posterior wall distance with BMI (p = 0.017). On the right, the UP-diaphragm distance correlated with gender (p = 0.002) and the lateral renal rotation was smaller (p = 0.046). CONCLUSIONS: Kidneys present significant mobility between supine and prone positions. CT assessment should be performed in the position expected during surgery and should be interpreted with caution, while a real-time imaging modality should be used in the operating room.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Humanos , Cálculos Renais/cirurgia , Nefrostomia Percutânea/métodos , Posicionamento do Paciente/métodos , Decúbito Ventral , Reprodutibilidade dos Testes , Decúbito Dorsal , Tomografia Computadorizada por Raios X
5.
Isr Med Assoc J ; 11(22): 688-695, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33249789

RESUMO

BACKGROUND: Acute pulmonary embolism (PE) is considered to be one of the most common cardiovascular diseases with considerable mortality. Conflicting data imply possible role for echocardiography in assessing this disease. OBJECTIVES: To determine which of the echo parameters best predicts short-term and long-term mortality in patients with PE. METHODS: We prospectively enrolled 235 patients who underwent computed tomography of pulmonary arteries (CTPA) and transthoracic Echocardiography (TTE) within < 24 hours. TTE included a prospectively designed detailed evaluation of the right heart including right ventricular (RV) myocardial performance index (RIMP), RV end diastolic and end systolic area, RV fractional area change, acceleration time (AT) of pulmonary flow and visual estimation. Interpretation and performance of TTE were blinded to the CTPA results. RESULTS: Although multiple TTE parameters were associated with PE, all had low discriminative capacity (AUC < 0.7). Parameters associated with 30-day mortality in univariate analysis were acceleration time (AT) < 81 msec (P = 0.04), stroke volume < 44 cc (P = 0.005), and RIMP > 0.42 (P = 0.05). The only RV independent echo parameter associated with poor long-term prognosis (adjusted for significant clinical, and routine echo associates of mortality) was RIMP (hazard ratio 3.0, P = 0.04). The only independent RV echo parameters associated with mortality in PE patients were RIMP (P = 0.05) and AT (P = 0.05). Addition of RIMP to nested models eliminated the significance of all other parameters assessing RV function. CONCLUSIONS: Doppler-based parameters like pulmonary flow AT, RIMP, and stroke volume, have additive value in addition to visual RV estimation to assess prognosis in patients with PE.


Assuntos
Ecocardiografia Doppler/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Volume Sistólico/fisiologia , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia/métodos , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Embolia Pulmonar/mortalidade , Tomografia Computadorizada por Raios X
6.
Cardiology ; 139(1): 11-16, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29130963

RESUMO

AIMS: Shift work disrupts the normal circadian rhythm and is associated with risk factors for coronary artery disease (CAD) and a higher incidence of CAD morbidity and mortality. Cardiac computed tomography angiography (CCTA) is a robust noninvasive modality for assessing the presence, extent, and severity of CAD. We sought to investigate whether shift workers are prone to a higher burden of CAD compared to non-shift workers. METHODS: We conducted a historically prospective study in consecutive patients who underwent CCTA and answered a telephonic questionnaire. Due to significant differences in age and gender, we compared 89 well-matched pairs of shift workers and non-shift workers with the use of propensity scores. RESULTS: Our cohort consisted of 349 participants, of whom 94 (26.9%) were shift workers. The mean age was 50.7 years, and 62.5% were males. After pairing, we showed that shift workers had a higher prevalence of CAD than non-shift workers (74.2 vs. 53.9%, respectively, p = 0.01), and a lower prevalence of coronary calcium scores of zero (46.8 vs. 63.4%, respectively, p = 0.034). Stenosis >50% was more prevalent in shift workers than in non-shift workers (20.2 vs. 11.2%, respectively, p = 0.006), and the extent of CAD (defined as the presence of ≥1-vessel disease) tended to be higher in shift workers than in non-shift workers (25.8 vs. 13.5%, respectively, p = 0.06). CONCLUSIONS: In this CCTA study, we showed in a well-matched cohort of consecutive patients that shift workers had a higher prevalence and extent of CAD than non-shift workers.


Assuntos
Doença da Artéria Coronariana/etiologia , Jornada de Trabalho em Turnos/efeitos adversos , Adulto , Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Pontuação de Propensão , Estudos Prospectivos , Fatores de Risco , Inquéritos e Questionários , Tolerância ao Trabalho Programado
7.
Cardiology ; 139(1): 62-69, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29237153

RESUMO

OBJECTIVES: To evaluate the association between very small left atria (VSLA) on nongated computed tomography pulmonary angiography (CTPA) and mortality in patients without pulmonary embolism (PE). METHODS: Patients who underwent nongated CTPA between 2011 and 2015 in order to rule out PE, and had an echocardiogram within 24 h of the CTPA, were retrospectively identified. The left atrial volume of nongated CTPA was calculated using automatic 4-chamber volumetric analysis software. The association between the lowest 5th percentile of the left atrial volume index, referred to as the VSLA group, and mortality was investigated after adjustment for age, gender, background diseases, and laboratory values. RESULTS: The study cohort included 241 patients. Patients with VSLA had a left atrial volume index <24 mL/m2 (n = 11). Demographics and background diseases did not differ between the study groups. The median follow-up was 22.7 months (IQR 0.03-54.3). VSLA was an independent predictor of mortality (HRadj = 3.6; 95% CI 1.46-8.87; p = 0.005), along with malignancy (HRadj = 2.28; 95% CI 1.32-3.93; p = 0.003) and lower hemoglobin (HRadj = 0.86; 95% CI 0.76-0.99; p = 0.032). CONCLUSIONS: Our findings suggest that VSLA on nongated CTPA may serve as a marker for mortality. The use of CTPA volumetric analysis can help risk stratification in patients with dyspnea and no PE.


Assuntos
Biomarcadores , Angiografia por Tomografia Computadorizada , Átrios do Coração/anatomia & histologia , Mortalidade , Artéria Pulmonar/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Tomografia Computadorizada de Feixe Cônico , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Prognóstico , Software , Análise de Sobrevida
8.
J Cardiovasc Electrophysiol ; 28(2): 240-248, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27763695

RESUMO

INTRODUCTION: A new imaging software (CARTO® Segmentation Module, Biosense Webster) allows preprocedural 3-D reconstruction of all heart chambers based on cardiac CT. We describe our initial experience with the new module during ablation of ventricular arrhythmias. METHODS AND RESULTS: Eighteen consecutive patients with idiopathic ventricular arrhythmias or ischemic ventricular tachycardia (VT) were studied. In the latter group, a combined endocardial and epicardial ablation was performed. Of the 14 patients with idiopathic arrhythmias, 12 were ablated in the outflow tract (OT), 1 in the midseptal left ventricle, and 1 at the left posterior fascicular area; acute successful ablation was achieved in 11 (78.6%) patients. The procedure was discontinued due to close proximity of the arrhythmia origin to the coronary arteries (CA) in 2 patients. Acute successful uncomplicated ablation was achieved in all 4 patients with ischemic VT. During ablation in the coronary cusps commissures, the CARTO® Segmentation Module accurately defined the cusps anatomy. The precise anatomic location provided by the module assisted in successfully ablating when information from activation mapping was not optimal, by ablating at the opposite side of the cusps. In addition, by demonstrating the precise location of the CA, it allowed safe ablation of arrhythmias that originated in close proximity to the CA both in the OT area and the epicardium, eliminating the need for repeat angiography. CONCLUSIONS: The CARTO® Segmentation Module is useful for accurate definition of the exact anatomic location of ventricular arrhythmias and for safely ablating them especially in close proximity to the CA.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Design de Software , Cirurgia Assistida por Computador/métodos , Taquicardia Ventricular/cirurgia , Fibrilação Ventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Técnicas de Imagem de Sincronização Cardíaca , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cirurgia Assistida por Computador/efeitos adversos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico por imagem , Fibrilação Ventricular/fisiopatologia
9.
Emerg Radiol ; 24(5): 519-523, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28397010

RESUMO

PURPOSE: We evaluated the corona mortis (CM) anatomy by means of three-dimensional computerized tomography angiographic (CTA). METHODS: Patient demographic, anastomosis incidence, artery diameter, artery distance from the symphysis pubis, and pelvic size (distance between both acetabular upper labrum) parameters were assessed. The 100 patients included 66 males and 34 females (average age of 67.8 years). RESULTS: There were 66 (33%) arterial anastomoses in the 200 evaluated arteries, 30 in the right side and 36 in the left side, 36 unilaterally and 15 bilaterally. No anastomoses were detected in 49 patients. The average diameter was 2.4 mm for the right-sided arteries and 2.24 in the left-sided ones. The distance was 55.2 mm from the right symphysis and 57.2 from the left symphysis (greater for females, 62.2 versus 55.85 mm [p = 0.037] only on the left side). The artery disappears in smaller-sized pelvises. There was a non-occluded arterial pattern in 47 (71%) and a partially occluded one in 19 (29%, all with peripheral vascular disease). CONCLUSION: One-third of the evaluated CTAs revealed competent CMs. CMs were more lateral in females than in males and were absent in small-sized pelvises. It is highly recommended that the radiologist and the surgeon should be familiar with CM existence for decision-making with regard to emergency radiology imaging and intervention as well as when operating in proximity of that anatomic site.


Assuntos
Anastomose Arteriovenosa/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Imageamento Tridimensional/métodos , Pelve/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
J Urol ; 195(2): 377-82, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26254723

RESUMO

PURPOSE: We assessed the approachability of the upper calyx through lower calyx access for prone and supine percutaneous nephrolithotomy and used computerized tomography to analyze anatomical factors that may influence it. MATERIALS AND METHODS: A prospective series of 45 patients treated with percutaneous nephrolithotomy were operated on in the prone (20) and supine (25) positions. Computerized tomography simulated access to the lower and upper calyx longitudinal axes were used to measure skin-to-lower calyx distance, thickness of the body wall, muscle and fat, the muscle-to-fat thickness ratio and the angle between the lower calyx tract and the upper calyx axis. Intraoperative approachability to the upper calyx was also evaluated. RESULTS: The upper calyx was successfully approached in 20% of prone and 80% of supine percutaneous nephrolithotomies (p <0.0001). The average skin-to-lower calyx distance was 98.4 mm (range 65.3 to 128.6) in the prone position and 98.7 mm (range 60.8 to 150) in the supine position (p = 0.99). Body wall and muscular thickness, and the muscle-to-fat thickness ratio were significantly lower in supine than prone nephrolithotomy (p <0.001, <0.0005 and <0.05, respectively). The average angle between the lower and upper calyces axes was wide in the supine position (141 degrees, range 90 to 170) and acute in the prone position (84 degrees, range 65 to 110, p <0.05(E-10)). CONCLUSIONS: Upper calyx endoscopic approachability through the lower calyx is significantly higher in supine than in prone percutaneous nephrolithotomies, possibly due to a thinner body wall, a thinner muscular layer, a lower muscle-to-fat thickness ratio and a wider angle between the lower and upper calyx axes.


Assuntos
Cálculos Renais/diagnóstico por imagem , Cálculos Renais/cirurgia , Cálices Renais/diagnóstico por imagem , Cálices Renais/cirurgia , Nefrostomia Percutânea/métodos , Tomografia Computadorizada por Raios X , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Decúbito Ventral , Estudos Prospectivos , Decúbito Dorsal
11.
Catheter Cardiovasc Interv ; 87(6): 1156-63, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26526673

RESUMO

OBJECTIVES: To investigate the impact of preprocedural left ventricular (LV) diastolic function on outcomes of patients with postprocedural aortic regurgitation (ARpost ) following transcatheter aortic valve replacement (TAVR). BACKGROUND: The predictors and mechanisms of the increased mortality in patients with ARpost are inadequately defined. METHODS: Baseline clinical and echocardiographic variables from a prospective TAVR registry were analyzed. Preprocedural correlates of late outcomes (all-cause mortality and the composite of mortality, stroke, heart failure, and new-onset atrial fibrillation) were examined according to the presence and severity of ARpost . RESULTS: Of the 418 patients undergoing TAVR, ARpost was present in 212 (51%): mild 36%, moderate-severe 15%. Mean follow-up was 909 ± 489 days. All-cause mortality and composite endpoint rates were significantly increased in patients with moderate-severe ARpost compared with patients with either none or only mild ARpost (38, 22, 21%, P = 0.02; and, 56, 35, 40%, P = 0.01; respectively). Moderate-severe (though not mild) ARpost was independently associated with mortality and the composite endpoint (HR = 1.93 [95%CI 1.15-3.14], P = 0.01; HR = 1.85 [95%CI 1.22-2.77], P = 0.004], respectively). By multivariate analysis, preprocedural LV deceleration time (DT) < 160 ms was independently associated with the risk of all-cause mortality and the composite endpoint among patients with mild AR (HR = 1.74 [95%CI 1.14-2.60], P = 0.01; and, HR = 1.73 [95%CI 1.23-2.41], P = 0.002, respectively) and moderate-severe ARpost (HR = 1.81 [95%CI 1.28-2.51], P < 0.001; HR = 1.86 [95%CI 0.22-2.80], P = 0.004, respectively). CONCLUSIONS: Preprocedural impairment of LV filling, reflected by short DT, portends an adverse prognosis in TAVR patients who develop ARpost independently of other clinical and echocardiocardigraphic measures including AS severity and systolic LV function. © 2015 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Função Ventricular Esquerda/fisiologia , Idoso de 80 Anos ou mais , Angiografia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Diástole , Ecocardiografia Doppler , Feminino , Próteses Valvulares Cardíacas , Humanos , Israel/epidemiologia , Masculino , Período Pré-Operatório , Prognóstico , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências
12.
Can Assoc Radiol J ; 67(2): 173-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26847811

RESUMO

PURPOSE: With the increased use of breast ultrasound for different indications, sonographically abnormal axillary lymph nodes are not a rare finding. We examined clinical and imaging characteristics in correlation with pathological reports of the sonographic guided biopsies to assess the yield of needle biopsy of these nodes. METHODS: Clinical, imaging and pathology data were collected for 171 consecutive patients who underwent sonographic guided needle biopsy of an abnormal lymph node between 2008 and 2013. Malignancy rates were examined for different clinical settings: palpable axillary mass, previous history of breast cancer, findings suggestive of a systemic disease, and those with a breast finding of low suspicion or an incidental abnormal axillary lymph node. Patients with newly diagnosed breast cancer were excluded. RESULTS: Twelve patients (7%) were found to have a malignancy on their axillary lymph node biopsy. Malignancy rates increased with age, and varied with clinical presentation: Axillary mass (8, 26%); history of breast cancer (2, 11%); systemic disease (0%) and breast finding of low suspicion or incidental abnormal lymph node on screening (1, 1%). Low rates of malignancy were found when the cortex was <6 mm (1, 0.8%). The most important imaging finding associated with malignancy was lack of a preserved hilum, in which case almost a third (10, 29%) of the biopsies were malignant. Only 1 of 89 women with a breast finding of low suspicion or an incidental abnormal axillary lymph node was found to have malignancy. In this case the lymph node had no hilum. CONCLUSIONS: In women without breast cancer, a highly suspicious breast mass or an axillary mass, more stringent criteria should be used when evaluating an abnormal axillary lymph node on sonography, as the malignancy rates are very low (1%).


Assuntos
Neoplasias da Mama/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Axila , Biópsia por Agulha , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia de Intervenção , Ultrassonografia Mamária , Adulto Jovem
13.
Radiology ; 277(1): 236-46, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25961630

RESUMO

PURPOSE: To use cardiovascular data from computerized tomographic (CT) pulmonary angiography for facilitating the identification of pulmonary hypertension (PH) in patients without acute pulmonary embolism. MATERIALS AND METHODS: The institutional human research committee approved this retrospective study; informed consent was waived. Patients without pulmonary embolism who underwent CT pulmonary angiography and echocardiography within 24 hours of each other between December 2008 and October 2012 were retrospectively identified. The diameters of the pulmonary artery, aorta, and right and left ventricles and the severity of reflux of contrast material were assessed. The volumes of each cardiac compartment were calculated. Doppler echocardiography served as a reference standard for PH. A prediction model for PH was built by using backward logistic regression and was presented on a nomogram. The prediction model was evaluated with 10-fold cross-validation, and a test group of patients was studied between November 2012 and June 2014. RESULTS: The final study group included 182 patients, of whom 98 (54%) were given a diagnosis of PH on the basis echocardiographic results. Age of 67 years or older (odds ratio [OR] = 4.46), reflux grade of 3 or higher (OR = 2.63), right atrial volume of greater than or equal to 106 cm(3) (OR = 3.59), pulmonary artery diameter greater than or equal to 28 mm (OR = 2.52) and pulmonary artery diameter to aorta diameter ratio of greater than or equal to 0.86 (OR = 2.17) were independently associated with PH. The logistic model showed good discrimination ability (area under the curve = 0.844, discrimination slope = 0.359). Tenfold cross-validation showed 85.7% sensitivity, 60.7% specificity, 71.3% positive predictive value, and 76.1% negative predictive value for identification of PH, while the test group showed similar results (84.1%, 60.5%, 71.2%, and 76.7%, respectively). CONCLUSION: Cardiovascular data derived from CT pulmonary angiography are associated with PH, and a nomogram can be created that may facilitate identification of PH after exclusion of acute pulmonary embolism.


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Nomogramas , Artéria Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Embolia Pulmonar , Estudos Retrospectivos
15.
J Endourol ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38919126

RESUMO

Background: Preoperative identification of the bowel on imaging is essential in planning renal access during percutaneous nephrolithotomy (PCNL) and avoiding colonic injury. We aimed this study to assess which noncontrast computed tomography (NCCT) window setting provides the optimal colonic identification for PCNL preoperative planning. Methods: Ten urologic surgeons (four seniors, six residents) reviewed 22 images of NCCT scans in both abdomen and lung window settings in a randomized blinded order. Colonic area delineation in each image was performed using a dedicated, commercially available area calculator software. A comparison of the marked colonic area between the abdomen and lung window settings was performed. Results: Overall, the mean marked colonic area was greater in the lung window compared with the abdomen window (8.82 cm2 vs 7.4 cm2, respectively, p < 0.001). Switching the CT window from abdomen to lung increased the identified colonic area in 50 cases (50%). Intraclass correlation showed good agreement between the senior readers and among all readers (0.92 and 0.87, respectively). Similar measurements of the colonic area in both abdomen and lung windows were observed in 26/44 (60%) of the seniors cases and in 7/66 (10%) of the resident cases (p = 0.002). Conclusion: Lung window solely or in combination with abdomen window appears to provide the most accurate colonic identification for preoperative planning of PCNL access and potentially reduce the risk of colonic injury. This pattern is more evident among young urologists, and we propose to introduce it as a standard sequence in PCNL preplanning.

16.
Clin Res Cardiol ; 113(1): 11-17, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36995477

RESUMO

BACKGROUND: Chronic coronary syndrome (CCS) is common among elderly patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). Current guidelines recommend performance of percutaneous coronary intervention (PCI) of any > 70% proximal coronary lesions prior to TAVI. AIMS: To evaluate the outcomes of two diagnostic approaches for CCS clearance pre-TAVI and to determine the reduction in the need of invasive angiography (IA). METHODS: We investigated 2219 patients undergoing TAVI for severe aortic stenosis at two large centers with different pre-procedural strategies for CCS assessment: pre-TAVI computed tomography angiography (CTA) with selective invasive angiography according to CTA results or mandatory IA. We preformed propensity score matching analysis using a 1:1 ratio. The final study cohort included 870 matched patients. Peri-procedural complications were documented according to the VARC-2 criteria. Mortality rates were prospectively documented. RESULTS: Mean age of the study population was 82 ± 7, of whom 55% were female. Patients in the IA group had significantly higher rates of pre-TAVI PCI compared to the CTA group (39% vs. 22%, p < 0.001). Following TAVI, peri-procedural myocardial infarction (MI) rates were similar between the two groups (0.3% vs. 0.7%, p value = 0.41), but spontaneous MI were significantly lower among the IA group (0% vs. 1.3%, p value = 0.03). Kaplan-Meier's survival analysis found that the cumulative probability of 1-year morality was similar between the two groups (p value log rank = 0.65). Cox regression analysis did not find association between CCS clearance strategy and outcome. CONCLUSIONS: In elderly patients, CTA-driven approach for CCS evaluation pre-TAVI is a valid strategy with similar outcome as compared to invasive approach. CTA strategy significantly reduces invasive procedures rates without compromising patient's outcome.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Masculino , Substituição da Valva Aórtica Transcateter/métodos , Intervenção Coronária Percutânea/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Pontuação de Propensão , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Doença da Artéria Coronariana/cirurgia , Infarto do Miocárdio/complicações , Valva Aórtica/cirurgia , Estudos Retrospectivos
17.
J Thorac Imaging ; 39(4): 208-216, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38635472

RESUMO

PURPOSE: Small left atrial (LA) volume was recently reported to be one of the best predictors of acute pulmonary embolism (PE)-related adverse events (AE). There is currently no data available regarding the impact that body surface area (BSA)-indexing of atrial measurements has on the association with PE-related adverse events. Our aim is to assess the impact of indexing atrial measurements to BSA on the association between computed tomography (CT) atrial measurements and AE. MATERIALS AND METHODS: Retrospective study (IRB: 2015P000425). A database of hospitalized patients with acute PE diagnosed on CT pulmonary angiography (CTPA) between May 2007 and December 2014 was reviewed. Right and left atrial volume, largest axial area, and axial diameters were measured. Patients undergo both echocardiographies (from which the BSA was extracted) and CTPAs within 48 hours of the procedure. The patient's body weight was measured during each admission. LA measurements were correlated to AE (defined as the need for advanced therapy or PE-related mortality at 30 days) before and after indexing for BSA. The area under the ROC curve was calculated to determine the predictive value of the atrial measurements in predicting AE. RESULTS: The study included 490 acute PE patients; 62 (12.7%) had AE. There was a significant association of reduced BSA-indexed and non-indexed LA volume (both <0.001), area (<0.001 and 0.001, respectively), and short-axis diameters (both <0.001), and their respective RA/LA ratios (all <0.001) with AE. The AUC values were similar for BSA-indexed and non-indexed LA volume, diameters, and area with LA volume measurements being the best predictor of adverse outcomes (BSA-indexed AUC=0.68 and non-indexed AUC=0.66), followed by non-indexed LA short-axis diameter (indexed AUC=0.65, non-indexed AUC=0.64), and LA area (indexed AUC=0.64, non-indexed AUC=0.63). CONCLUSION: Adjusting for BSA does not substantially affect the predictive ability of atrial measurements on 30-day PE-related adverse events, and therefore, this adjustment is not necessary in clinical practice. While LA volume is the better predictor of AE, LA short-axis diameter has a similar predictive value and is more practical to perform clinically.


Assuntos
Superfície Corporal , Angiografia por Tomografia Computadorizada , Átrios do Coração , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagem , Feminino , Estudos Retrospectivos , Masculino , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Angiografia por Tomografia Computadorizada/métodos , Tamanho do Órgão , Ecocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso de 80 Anos ou mais
18.
Catheter Cardiovasc Interv ; 82(4): E578-82, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23592438

RESUMO

BACKGROUND: The relative radiation dose (RD) of patients undergoing transcatheter aortic valve implantation (TAVI) with either the Edwards Sapien XT (ESX) or the Medtronic CoreValve (MCV) prostheses has not been studied in depth. Our aim was to quantify RD in uncomplicated transfemoral TAVI with either prosthesis. METHODS: We analyzed 248 consecutive patients undergoing uncomplicated transfemoral TAVI between March 2009 and September 2012, at a single tertiary care facility. Total air Kerma, cumulated dose area product (DAP), and fluoroscopy time were determined in each case. RESULTS: The ESX and MCV prostheses were implanted in 44 and 204 patients, respectively. Though mean fluoroscopy time was higher during ESX valve implantation, overall RD per total air Kerma and DAP was significantly higher during MCV implantation (P < 0.05 for both comparisons). By multivariate regression analyses, prosthesis type was an independent predictor of RD according to both total air Kerma and DAP (r(2) = 0. 498; P < 0.01 and r(2) = 0.363; P < 0.01, respectively). CONCLUSION: In uncomplicated transfemoral TAVI, RD is greater during MCV implantation than during ESX implantation.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Artéria Femoral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Doses de Radiação , Radiografia Intervencionista , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Distribuição de Qui-Quadrado , Feminino , Fluoroscopia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Desenho de Prótese , Monitoramento de Radiação , Radiografia Intervencionista/efeitos adversos , Fatores de Risco , Resultado do Tratamento
19.
Diagnostics (Basel) ; 13(14)2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37510080

RESUMO

Hypersensitivity pneumonitis (HP) is a heterogeneous interstitial lung disease (ILD) that may be difficult to confidently diagnose. Recently, the 2020 ATS/JRS/ALAT HP diagnostic guidelines were published, yet data validating their performance in real-life settings are scarce. We aimed to assess the diagnostic performance of the HP guidelines compared to the gold-standard multidisciplinary discussion (MDD). For this purpose, we included consecutive ILD patients that underwent diagnostic bronchoscopy between 2017 and 2020 in three large medical centers. Four diagnostic factors (antigen exposure history, chest computed tomography pattern, bronchoalveolar lavage lymphocyte count, and histology results) were used to assign guidelines-based HP diagnostic confidence levels for each patient. A sensitivity analysis was performed, with MDD diagnosis as the reference standard. Overall, 213 ILD patients were included, 45 (21%) with an MDD diagnosis of HP. The guidelines' moderate (≥70%) confidence threshold produced optimal performance with 73% sensitivity for HP, 89% specificity, and a J-index of 0.62. The area under the receiver operating characteristic curve (AUC) for a correct guidelines-based diagnosis was 0.86. The guidelines had better performance for non-fibrotic than fibrotic HP (AUC 0.92 vs. 0.82). All diagnostic factors, except bronchoalveolar lavage lymphocyte count, were independent predictors for MDD diagnosis of HP in a multivariate analysis. In conclusion, the HP guidelines exhibited a good diagnostic performance compared to MDD diagnosis in real-life setting.

20.
J Clin Oncol ; 41(14): 2503-2510, 2023 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-36669135

RESUMO

PURPOSE: Cancer is the second leading cause of death globally. However, by implementing evidence-based prevention strategies, 30%-50% of cancers can be detected early with improved outcomes. At the integrated cancer prevention center (ICPC), we aimed to increase early detection by screening for multiple cancers during one visit. METHODS: Self-referred asymptomatic individuals, age 20-80 years, were included prospectively. Clinical, laboratory, and epidemiological data were obtained by multiple specialists, and further testing was obtained based on symptoms, family history, individual risk factors, and abnormalities identified during the visit. Follow-up recommendations and diagnoses were given as appropriate. RESULTS: Between January 1, 2006, and December 31, 2019, 8,618 men and 8,486 women, average age 47.11 ± 11.71 years, were screened. Of 259 cancers detected through the ICPC, 49 (19.8%) were stage 0, 113 (45.6%) stage I, 30 (12.1%) stage II, 25 (10.1%) stage III, and 31(12.5%) stage IV. Seventeen cancers were missed, six of which were within the scope of the ICPC. Compared with the Israeli registry, at the ICPC, less cancers were diagnosed at a metastatic stage for breast (none v 3.7%), lung (6.7% v 11.4%), colon (20.0% v 46.2%), prostate (5.6% v 10.5%), and cervical/uterine (none v 8.5%) cancers. When compared with the average stage of detection in the United States, detection was earlier for breast, lung, prostate, and female reproductive cancers. Patient satisfaction rate was 8.35 ± 1.85 (scale 1-10). CONCLUSION: We present a proof of concept study for a one-stop-shop approach to cancer screening in a multidisciplinary outpatient clinic. We successfully detected cancers at an early stage, which has the potential to reduce morbidity and mortality as well as offer substantial cost savings.[Media: see text].


Assuntos
Detecção Precoce de Câncer , Neoplasias dos Genitais Femininos , Masculino , Humanos , Feminino , Estados Unidos , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Idoso , Idoso de 80 Anos ou mais , Mama , Pulmão , Sistema de Registros , Programas de Rastreamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA