Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Rev Lett ; 104(4): 043401, 2010 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-20366708

RESUMO

The complete fragmentation of highly excited and multicharged C(n)(q+) clusters (n=5-10; q=2-4), produced in high velocity collisions of C(n)(+) with atoms, has been measured. Multiplicity distributions are presented and used to deduce, within a statistical framework, the partitioning of energy between the fragments' production and fragments' kinetic energy. This partitioning is found to scale as the charge over mass ratio of the cluster.

2.
J Chem Phys ; 130(19): 194301, 2009 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-19466830

RESUMO

The photofragmentation dynamics of Ar(2)(+) and Ar(3)(+) clusters has been investigated at a 527 nm wavelength (2.35 eV) using a setup that allows simultaneous detection of the ionic and neutral fragments in a coincidence experiment. Measurement of positions and times of flight enables in principle a complete description of the fragmentation dynamics. The photofragmentation dynamics of Ar(3)(+) clusters is similar to that of Ar(2)(+) with, in addition, the ejection of a third fragment that can be neutral or ionized via a resonant electron capture. This is attributed to the triangular geometry of the Ar(3)(+) ion.

3.
Rev Sci Instrum ; 82(10): 103301, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22047285

RESUMO

We show that an x-ray charge coupled device (CCD) may be used as a particle detector for atomic and molecular mega-electron-volt (MeV) projectiles of around a few hundred keV per atomic mass unit. For atomic species, spectroscopic properties in kinetic energy measurements (i.e., linearity and energy resolution) are found to be close to those currently obtained with implanted or surface barrier silicon particle detectors. For molecular species, in order to increase the maximum kinetic energy detection limit, we propose to put a thin foil in front of the CCD. This foil breaks up the molecules into atoms and spreads the charges over many CCD pixels and therefore avoiding saturation effects. This opens new perspectives in high velocity molecular dissociation studies with accelerator facilities.

4.
J Chem Phys ; 128(12): 124312, 2008 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-18376924

RESUMO

We have measured fragmentation branching ratios of neutral C(n)H and C(n)H(+) cations produced in high velocity (4.5 a.u) collisions between incident C(n)H(+) cations and helium atoms. Electron capture gives rise to excited neutral species C(n)H and electronic excitation to excited cations C(n)H(+). Thanks to a dedicated setup, based on coincident detection of all fragments, the dissociations of the neutral and cationic parents were recorded separately and in a complete way. For the fragmentation of C(n)H, the H-loss channel is found to be dominant, as already observed by other authors. By contrast, the H-loss and C-loss channels equally dominate the two-fragment break up of C(n)H(+) species. For these cations, we provide the first fragmentation data (n>2). Results are also discussed in the context of astrochemistry.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA