Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Chest ; 130(4): 1063-71, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17035439

RESUMO

Studies of the efficacy of heliox in patients with severe asthma have shown mixed results. Among the factors that are responsible for variable outcomes, the failure of heliox delivery systems to prevent room air entrainment (RAE) during beta-agonist delivery is probably the most critical. While keeping the rotameter flow rate (FR) of heliox mixed 70:30 to a nebulizer at 10 L/min, the FR of heliox from a second gas source to a T-connector (TC) was increased during the delivery of the beta-agonist with a conventional T-nebulizer delivery system (TNDS). A negative peak inspiratory flow (pneumotachometer reading) or a helium concentration of < 70% (quadralizer reading) were indicators of RAE. RAE was tested during spontaneous tidal breathing and acute asthma. A rotameter FR of 10 L/m to the nebulizer with no flow from a second gas source to a TC (conventional TNDS) resulted in a significant drop in helium concentration during tidal breathing (46.2%) and acute asthma (27.5%) due to RAE. This degree of helium dilution can negate the beneficial effects of heliox to lung mechanics almost completely. A rotameter FR of 10 L/m each to a nebulizer and a TC resulted in a helium concentration 69.8% during tidal breathing (no RAE), but 49% (significant RAE) during asthma events. A rotameter FR of 15 L/m (pressure regulator setting, 100 lbs per square inch) to a TC, while maintaining a rotameter FR of 10 L/m to a nebulizer prevented RAE during asthma (helium concentration, 69.9%). Conventional TNDS may be used to deliver the beta-agonist with heliox during asthma without RAE.


Assuntos
Agonistas Adrenérgicos beta/administração & dosagem , Ar , Resistência das Vias Respiratórias/efeitos dos fármacos , Albuterol/administração & dosagem , Asma/tratamento farmacológico , Sistemas de Liberação de Medicamentos/instrumentação , Hélio/administração & dosagem , Nebulizadores e Vaporizadores , Oxigênio/administração & dosagem , Relação Dose-Resposta a Droga , Humanos , Técnicas In Vitro , Modelos Biológicos , Troca Gasosa Pulmonar/efeitos dos fármacos , Volume de Ventilação Pulmonar/efeitos dos fármacos
3.
Trop Doct ; 32(3): 135-8, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12139150

RESUMO

A study was undertaken on 500 children under the age of 5 years belonging to a low income group. All were attending the paediatrics outpatient department of a large teaching hospital in New Delhi, India. Only 25% were found to have received complete primary immunization as per the National Immunization Schedule (bacille Calmette-Guérin at birth, three doses of diphtheria, pertussis and tetanus and oral poliovirus vaccine at 6,10 and 14 weeks and measles vaccine at 9 months). The major reasons for non-immunization of the children were: migration to a native village (26.4%); domestic problems (9.6%); the immunization centre was located too far from their home (9.6%); and the child was unwell when the vaccination was due (9%). Twelve per cent of mothers could not give any reason for non-immunization. In addition to the migration of children to rural areas, the other significant finding was an indirect effect of intensive OPV administration as part of polio eradication initiative. The lack of awareness and fear of side effects constituted a small minority of reasons for non-immunization.


Assuntos
Conhecimentos, Atitudes e Prática em Saúde , Imunização/estatística & dados numéricos , Pré-Escolar , Feminino , Acessibilidade aos Serviços de Saúde , Humanos , Índia , Lactente , Masculino , Dinâmica Populacional , Pobreza , População Urbana
4.
J Hosp Med ; 3(3): 200-5, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18571776

RESUMO

BACKGROUND: Sleep deprivation, compounded by circadian disruptions, is a common problem in health care workers. Sleepiness in nurses has important implications for patients as well as nurses' own safety. OBJECTIVE: The objective of the study was to assess comprehensively sleepiness levels in post-night-shift nurses. METHODS: Post-night-shift nurses in the ICU and on general floors (medicine and surgery) were assessed using subjective (Epworth Sleepiness Scale [ESS]) and objective (Mean Sleep Latency Test [MSLT]) measures. RESULTS: ESS was abnormal (>8) in 7 of 10 ICU nurses compared with 2 of 10 floor nurses (P < .005), and mean ESS score was also higher (8.7 +/- 3.9 vs. 5.6 +/- 2.1, respectively; P = 0.042). MSLT values for the first nap period were in the pathologic range in the ICU nurses compared with the floor nurses (4.65 +/- 5.5 vs. 10.85 +/- 7.4 minutes, respectively; P < .05). CONCLUSIONS: Post-night-shift RNs working in the ICU have a pathologic degree of sleepiness.


Assuntos
Cuidados Críticos/organização & administração , Recursos Humanos de Enfermagem Hospitalar/organização & administração , Admissão e Escalonamento de Pessoal/organização & administração , Fases do Sono , Tolerância ao Trabalho Programado , Adulto , Feminino , Pesquisa sobre Serviços de Saúde , Humanos , Masculino , Projetos Piloto , Qualidade da Assistência à Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA