Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Mol Sci ; 24(3)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36769254

RESUMO

The covalent functionalization of synthetic peptides allows the modification of different biomaterials (metallic, polymeric, and ceramic), which are enriched with biologically active sequences to guide cell behavior. Recently, this strategy has also been applied to decellularized biological matrices. In this study, the covalent anchorage of a synthetic peptide (REDV) to a pericardial matrix decellularized via Schiff base is realized starting from concentrated peptide solutions (10-4 M and 10-3 M). The use of a labeled peptide demonstrated that as the concentration of the working solution increased, the surface density of the anchored peptide increased as well. These data are essential to pinpointing the concentration window in which the peptide promotes the desired cellular activity. The matrices were extensively characterized by Water Contact Angle (WCA) analysis, Differential Scanning Calorimetry (DSC) analysis, geometric feature evaluation, biomechanical tests, and preliminary in vitro bioassays.


Assuntos
Peptídeos , Pericárdio , Materiais Biocompatíveis
2.
Int J Mol Sci ; 23(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35269969

RESUMO

Bladder cancer (BC) is among the most common malignancies in the world and a relevant cause of cancer mortality. BC is one of the most frequent causes for bladder removal through radical cystectomy, the gold-standard treatment for localized muscle-invasive and some cases of high-risk, non-muscle-invasive bladder cancer. In order to restore urinary functionality, an autologous intestinal segment has to be used to create a urinary diversion. However, several complications are associated with bowel-tract removal, affecting patients' quality of life. The present study project aims to develop a bio-engineered material to simplify this surgical procedure, avoiding related surgical complications and improving patients' quality of life. The main novelty of such a therapeutic approach is the decellularization of a porcine small intestinal submucosa (SIS) conduit to replace the autologous intestinal segment currently used as urinary diversion after radical cystectomy, while avoiding an immune rejection. Here, we performed a preliminary evaluation of this acellular product by developing a novel decellularization process based on an environmentally friendly, mild detergent, i.e., Tergitol, to replace the recently declared toxic Triton X-100. Treatment efficacy was evaluated through histology, DNA, hydroxyproline and elastin quantification, mechanical and insufflation tests, two-photon microscopy, FTIR analysis, and cytocompatibility tests. The optimized decellularization protocol is effective in removing cells, including DNA content, from the porcine SIS, while preserving the integrity of the extracellular matrix despite an increase in stiffness. An effective sterilization protocol was found, and cytocompatibility of treated SIS was demonstrated from day 1 to day 7, during which human fibroblasts were able to increase in number and strongly organize along tissue fibres. Taken together, this in vitro study suggests that SIS is a suitable candidate for use in urinary diversions in place of autologous intestinal segments, considering the optimal results of decellularization and cell proliferation. Further efforts should be undertaken in order to improve SIS conduit patency and impermeability to realize a future viable substitute.


Assuntos
Neoplasias da Bexiga Urinária , Animais , DNA , Humanos , Mucosa Intestinal , Intestino Delgado , Qualidade de Vida , Suínos , Engenharia Tecidual/métodos , Neoplasias da Bexiga Urinária/cirurgia
3.
J Mater Sci Mater Med ; 32(8): 86, 2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34313865

RESUMO

Over the years, several devices have been created (and the development of many others is currently in progress) to be in permanent contact with blood: mechanical circulatory supports represent an example thereof. The hemocompatibility of these devices largely depends on the chemical composition of blood-contacting components. In the present work, an innovative material (hybrid membrane) is proposed to fabricate the inner surfaces of a pulsatile ventricular chamber: it has been obtained by coupling a synthetic polymer (e.g., commercial polycarbonate urethane) with decellularized porcine pericardium. The hemocompatibility of the innovative material has been preliminarily assessed by measuring its capacity to promote thrombin generation and induce platelet activation. Our results demonstrated the blood compatibility of the proposed hybrid membrane.


Assuntos
Plaquetas/efeitos dos fármacos , Sangue/efeitos dos fármacos , Materiais Revestidos Biocompatíveis , Membranas Artificiais , Ativação Plaquetária , Adulto , Animais , Sangue/metabolismo , Feminino , Humanos , Teste de Materiais/métodos , Pericárdio/química , Pericárdio/efeitos dos fármacos , Cimento de Policarboxilato/química , Polímeros/química , Estresse Mecânico , Propriedades de Superfície , Suínos , Trombina/química , Uretana/química
4.
Annu Rev Biomed Eng ; 21: 85-110, 2019 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-30795701

RESUMO

There are limited therapeutic options for final treatment of end-stage heart failure. Among them, implantation of a total artificial heart (TAH) is an acceptable strategy when suitable donors are not available. TAH development began in the 1930s, followed by a dramatic evolution of the actuation mechanisms operating the mechanical pumps. Nevertheless, the performance of TAHs has not yet been optimized, mainly because of the low biocompatibility of the blood-contacting surfaces. Low hemocompatibility, calcification, and sensitivity to infections seriously affect the success of TAHs. These unsolved issues have led to the withdrawal of many prototypes during preclinical phases of testing. This review offers a comprehensive analysis of the pathophysiological events that may occur in the materials that compose TAHs developed to date. In addition, this review illustrates bioengineering strategies to prevent these events and describes the most significant steps toward the achievement of a fully biocompatible TAH.


Assuntos
Materiais Biocompatíveis/química , Calcinose/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Coração Artificial , Desenho de Prótese , Cardiologia/tendências , Matriz Extracelular/metabolismo , Coração/fisiologia , Humanos , Prognóstico , Propriedades de Superfície , Engenharia Tecidual/métodos
5.
Artif Organs ; 42(5): 540-548, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29280157

RESUMO

Bovine and porcine pericardia are currently used for manufacturing prosthetic heart valves: their design has become an increasingly important area of investigation in parallel with progressively expanding indications for the transcutaneous approach to heart valves replacement. Before being cut and shaped, pericardial tissues are expected to be properly characterized. Actually, the mechanical assessment of these biomaterials lacks standardized protocols. In particular, the role of preconditioning for achieving a constant mechanical response of tissue samples is still controversial. In the present work, the mechanical response to uniaxial load of native bovine and porcine pericardia, with and without preconditioning was assessed; moreover, the mechanical behavior of pericardia was investigated and explained. It was demonstrated that: (i) pericardial tissue samples hold memory of the loading history but just within the extent of the deformation applied; (ii) the behavior of native bovine and porcine pericardia in response to load is explained by a mechanism based on the additive recruitment of collagen fibers; (iii) the current concept that plasticity is absent in pericardium has to be at least in part reconsidered.


Assuntos
Colágeno/análise , Pericárdio/fisiologia , Pericárdio/ultraestrutura , Animais , Fenômenos Biomecânicos , Bioprótese , Bovinos , Colágeno/metabolismo , Próteses Valvulares Cardíacas , Teste de Materiais , Pericárdio/química , Suínos , Resistência à Tração , Suporte de Carga
6.
J Artif Organs ; 20(4): 394-398, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29018980

RESUMO

The formation of thrombotic deposits affects the functionality of mechanical prosthetic heart valves; as a consequence, mechanical valves thrombosis needs early diagnosis to prevent thromboembolic events. This paper compares the acoustic signals produced by two commercial bileaflet mechanical heart valves in the closing phase to detect the presence of thrombi. The closing sounds were recorded in vitro by means of a phonocardiographic device under different hydrodynamic conditions. Thrombotic deposits of different weight and shape were applied onto the valve leaflet and the annular housing, until the movement of one leaflet was completely blocked. From the acoustic signals, the corresponding spectra were calculated and four diagnostic frequency bands were identified: their comparison allowed detecting malfunctioning valves because of the presence of thrombotic formations.


Assuntos
Acústica , Doenças das Valvas Cardíacas/diagnóstico , Próteses Valvulares Cardíacas , Trombose/diagnóstico , Doenças das Valvas Cardíacas/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Valvas Cardíacas , Humanos , Hidrodinâmica , Desenho de Prótese , Trombose/etiologia
7.
Cell Tissue Res ; 366(1): 51-61, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27130570

RESUMO

Haemophilic arthropathy is the major cause of disability in patients with haemophilia and, despite prophylaxis with coagulation factor concentrates, some patients still develop articular complications. We evaluate the feasibility of a tissue engineering approach to improve current clinical strategies for cartilage regeneration in haemophiliacs by using autologous chondrocytes (haemophilic chondrocytes; HaeCs). Little is known about articular chondrocytes from haemophilic patients and no characterisation has as yet been performed. An investigation into whether blood exposure alters HaeCs should be interesting from the perspective of autologous implants. The typical morphology and expression of specific target genes and surface markers were therefore assessed by optical microscopy, reverse transcription plus the polymerase chain reaction (PCR), real-time PCR and flow-cytometry. We then considered chondrocyte behaviour on a bio-hybrid scaffold (based on polyvinyl alcohol/Wharton's jelly) as an in vitro model of articular cartilage prosthesis. Articular chondrocytes from non-haemophilic donors were used as controls. HaeC morphology and the resulting immunophenotype CD44(+)/CD49c(+)/CD49e(+)/CD151(+)/CD73(+)/CD49f(-)/CD26(-) resembled those of healthy donors. Moreover, HaeCs were active in the transcription of genes involved in the synthesis of the extracellular matrix proteins of the articular cartilage (ACAN, COL1A, COL2A, COL10A, COL9A, COMP, HAS1, SOX9), although the over-expression of COL1A1, COL10A1, COMP and HAS was observed. In parallel, the composite scaffold showed adequate mechanical and biological properties for cartilage tissue engineering, promoting chondrocyte proliferation. Our preliminary evidence contributes to the characterisation of HaeCs, highlighting the opportunity of using them for autologous cartilage implants in patients with haemophilia.


Assuntos
Condrócitos/citologia , Condrogênese , Hemofilia A/patologia , Cartilagem Articular/efeitos dos fármacos , Cartilagem Articular/patologia , Proliferação de Células/efeitos dos fármacos , Forma Celular/efeitos dos fármacos , Condrócitos/efeitos dos fármacos , Condrócitos/metabolismo , Condrócitos/ultraestrutura , Condrogênese/efeitos dos fármacos , Módulo de Elasticidade/efeitos dos fármacos , Feminino , Regulação da Expressão Gênica/efeitos dos fármacos , Hemofilia A/genética , Humanos , Imunofenotipagem , Masculino , Pessoa de Meia-Idade , Álcool de Polivinil/farmacologia , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Reação em Cadeia da Polimerase em Tempo Real , Estresse Mecânico , Alicerces Teciduais , Transplante Autólogo
8.
Biomimetics (Basel) ; 9(4)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38667213

RESUMO

The inner structures of the eye are protected by the cornea, which is a transparent membrane exposed to the external environment and subjected to the risk of lesions and diseases, sometimes resulting in impaired vision and blindness. Several eye pathologies can be treated with a keratoplasty, a surgical procedure aimed at replacing the cornea with tissues from human donors. Even though the success rate is high (up to 90% for the first graft in low-risk patients at 5-year follow-up), this approach is limited by the insufficient number of donors and several clinically relevant drawbacks. Alternatively, keratoprosthesis can be applied in an attempt to restore minimal functions of the cornea: For this reason, it is used only for high-risk patients. Recently, many biomaterials of both natural and synthetic origin have been developed as corneal substitutes to restore and replace diseased or injured corneas in low-risk patients. After illustrating the traditional clinical approaches, the present paper aims to review the most innovative solutions that have been recently proposed to regenerate the cornea, avoiding the use of donor tissues. Finally, innovative approaches to biological tissue 3D printing and xenotransplantation will be mentioned.

9.
Bioengineering (Basel) ; 11(5)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38790303

RESUMO

The production of biomedical devices able to appropriately interact with the biological environment is still a great challenge. Synthetic materials are often employed, but they fail to replicate the biological and functional properties of native tissues, leading to a variety of adverse effects. Several commercial products are based on chemically treated xenogeneic tissues: their principal drawback is due to weak mechanical stability and low durability. Recently, decellularization has been proposed to bypass the drawbacks of both synthetic and biological materials. Acellular materials can integrate with host tissues avoiding/mitigating any foreign body response, but they often lack sufficient patency and impermeability. The present paper investigates an innovative approach to the realization of hybrid materials that combine decellularized bovine pericardium with polycarbonate urethanes. These hybrid materials benefit from the superior biocompatibility of the biological tissue and the mechanical properties of the synthetic polymers. They were assessed from physicochemical, structural, mechanical, and biological points of view; their ability to promote cell growth was also investigated. The decellularized pericardium and the polymer appeared to well adhere to each other, and the two sides were distinguishable. The maximum elongation of hybrid materials was mainly affected by the pericardium, which allows for lower elongation than the polymer; this latter, in turn, influenced the maximum strength achieved. The results confirmed the promising features of hybrid materials for the production of vascular grafts able to be repopulated by circulating cells, thus, improving blood compatibility.

10.
J Biomed Mater Res A ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783716

RESUMO

Population aging, reduced economic capacity, and neglecting the treatments for oral pathologies, are the main causal factors for about 3 billion individuals who are suffering from partial/total edentulism or alveolar bone resorption: thus, the demand for dental implants is increasingly growing. To achieve a good prognosis for implant-supported restorations, adequate peri-implant bone volume is mandatory. The Guided Bone Regeneration (GBR) technique is one of the most applied methods for alveolar bone reconstruction and treatment of peri-implant bone deficiencies. This technique involves the use of different types of membranes in association with some bone substitutes (autologous, homologous, or heterologous). However, time for bone regeneration is often too long and the bone quality is not simply predictable. This study aims at engineering and evaluating the efficacy of modified barrier membranes, enhancing their bioactivity for improved alveolar bone tissue regeneration. We investigated membranes functionalized with chitosan (CS) and chitosan combined with the peptide GBMP1α (CS + GBMP1α), to improve bone growth. OsseoGuard® membranes, derived from bovine Achilles tendon type I collagen crosslinked with formaldehyde, were modified using CS and CS + GBMP1α. The functionalization, carried out with 1-ethyl-3-(3 dimethylaminopropyl)carbodiimide and sulfo-N-Hydroxysuccinimide (EDC/sulfo-NHS), was assessed through FT-IR and XPS analyses. Biological assays were performed by directly seeding human osteoblasts onto the materials to assess cell proliferation, mineralization, gene expression of Secreted Phosphoprotein 1 (SPP1) and Runt-Related Transcription Factor 2 (Runx2), and antibacterial properties. Both CS and CS + GBMP1α functionalizations significantly enhanced human osteoblast proliferation, mineralization, gene expression, and antibacterial activity compared to commercial membranes. The CS + GBMP1α functionalization exhibited superior outcomes in all biological assays. Mechanical tests showed no significant alterations of membrane biomechanical properties post-functionalization. The engineered membranes, especially those functionalized with CS + GBMP1α, are suitable for GBR applications thanks to their ability to enhance osteoblast activity and promote bone tissue regeneration. These findings suggest a potential advancement in the treatment of oral cavity problems requiring bone regeneration.

11.
J Heart Valve Dis ; 22(6): 828-36, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24597405

RESUMO

BACKGROUND AND AIM OF THE STUDY: The main disadvantage of a mechanical heart valve (MHV) is thrombosis, a serious complication that is associated with high morbidity and mortality. The early detection of thrombotic formations is crucial for a prompt diagnosis and correct therapy before critical symptoms appear in patients. The present study describes the in-vitro assessment of thrombotic deposits by ultrasound phonocardiography on five commercially available bileaflet MHVs. METHODS: The closing sounds produced by bileaflet MHVs were acquired in the frequency range from 6 to 55 kHz. The corresponding power spectra were calculated and then analyzed by an artificial neural network (ANN) trained to classify the presence of simulated thrombotic formations of different weight and shape. Simulations were performed in a Sheffield pulse duplicator under different hydrodynamic regimes. RESULTS: Classification performances of the ANN depend on the range of frequency considered: better performances (up to 100% correct classification) are achieved when the entire spectrum is considered, rather than the audible (down to 87%) and ultrasound (down to 61%) regions, separately. CONCLUSION: Good and very good classification performances are achieved in vitro when phonocardiography is applied to detect and analyze the closing sounds produced by MHVs. Interestingly, extension of the analysis to the ultrasound region can improve classification efficiency. This finding allows the consideration of potential clinical applications of the proposed method to assign an MHV recipient to a risk class, thus enabling a prompt diagnosis.


Assuntos
Doenças das Valvas Cardíacas/diagnóstico , Próteses Valvulares Cardíacas/efeitos adversos , Fonocardiografia/métodos , Trombose/diagnóstico , Ultrassom , Simulação por Computador , Diagnóstico Precoce , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/fisiopatologia , Hidrodinâmica , Teste de Materiais , Modelos Cardiovasculares , Redes Neurais de Computação , Valor Preditivo dos Testes , Desenho de Prótese , Processamento de Sinais Assistido por Computador , Trombose/etiologia , Trombose/fisiopatologia
12.
Biomimetics (Basel) ; 8(1)2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36810380

RESUMO

During the last 20 years, tantalum has known ever wider applications for the production of endosseous implantable devices in the orthopedic and dental fields. Its excellent performances are due to its capacity to stimulate new bone formation, thus improving implant integration and stable fixation. Tantalum's mechanical features can be mainly adjusted by controlling its porosity thanks to a number of versatile fabrication techniques, which allow obtaining an elastic modulus similar to that of bone tissue, thus limiting the stress-shielding effect. The present paper aims at reviewing the characteristics of tantalum as a solid and porous (trabecular) metal, with specific regard to biocompatibility and bioactivity. Principal fabrication methods and major applications are described. Moreover, the osteogenic features of porous tantalum are presented to testify its regenerative potential. It can be concluded that tantalum, especially as a porous metal, clearly possesses many advantageous characteristics for endosseous applications but it presently lacks the consolidated clinical experience of other metals such as titanium.

13.
Polymers (Basel) ; 15(4)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36850103

RESUMO

Right ventricle outflow tract obstruction (RVOTO) is a congenital pathological condition that contributes to about 15% of congenital heart diseases. In most cases, the replacement of the right ventricle outflow in pediatric age requires subsequent pulmonary valve replacement in adulthood. The aim of this study was to investigate the extracellular matrix scaffold obtained by decellularization of the porcine pulmonary valve using a new detergent (Tergitol) instead of Triton X-100. The decellularized scaffold was evaluated for the integrity of its extracellular matrix (ECM) structure by testing for its biochemical and mechanical properties, and the cytotoxicity/cytocompatibility of decellularized tissue was assessed using bone marrow-derived mesenchymal stem cells. We concluded that Tergitol could remove the nuclear material efficiently while preserving the structural proteins of the matrix, but without an efficient removal of the alpha-gal antigenic epitope. Therefore, Tergitol can be used as an alternative detergent to replace the Triton X-100.

14.
J Funct Biomater ; 14(3)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36976065

RESUMO

Conduit substitutes are increasingly in demand for cardiovascular and urological applications. In cases of bladder cancer, radical cystectomy is the preferred technique: after removing the bladder, a urinary diversion has to be created using autologous bowel, but several complications are associated with intestinal resection. Thus, alternative urinary substitutes are required to avoid autologous intestinal use, preventing complications and facilitating surgical procedures. In the present paper, we are proposing the exploitation of the decellularized porcine descending aorta as a novel and original conduit substitute. After being decellularized with the use of two alternative detergents (Tergitol and Ecosurf) and sterilized, the porcine descending aorta has been investigated to assess its permeability to detergents through methylene blue dye penetration analysis and to study its composition and structure by means of histomorphometric analyses, including DNA quantification, histology, two-photon microscopy, and hydroxyproline quantification. Biomechanical tests and cytocompatibility assays with human mesenchymal stem cells have been also performed. The results obtained demonstrated that the decellularized porcine descending aorta preserves its major features to be further evaluated as a candidate material for urological applications, even though further studies have to be carried out to demonstrate its suitability for the specific application, by performing in vivo tests in the animal model.

15.
J Funct Biomater ; 13(4)2022 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-36412863

RESUMO

Among the urinary tract's malignancies, bladder cancer is the most frequent one: it is at the tenth position of most common cancers worldwide. Currently, the gold standard therapy consists of radical cystectomy, which results in the need to create a urinary diversion using a bowel segment from the patient. Nevertheless, due to several complications associated with bowel resection and anastomosis, which significantly affect patient quality of life, it is becoming extremely important to find an alternative solution. In our recent work, we proposed the decellularized porcine small intestinal submucosa (SIS) as a candidate material for urinary conduit substitution. In the present study, we create SIS-based hybrid membranes that are obtained by coupling decellularized SIS with two commercially available polycarbonate urethanes (Chronoflex AR and Chronoflex AR-LT) to improve SIS mechanical resistance and impermeability. We evaluated the hybrid membranes by means of immunofluorescence, two-photon microscopy, FTIR analysis, and mechanical and cytocompatibility tests. The realization of hybrid membranes did not deteriorate SIS composition, but the presence of polymers ameliorates the mechanical behavior of the hybrid constructs. Moreover, the cytocompatibility tests demonstrated a significant increase in cell growth compared to decellularized SIS alone. In light of the present results, the hybrid membrane-based urinary conduit can be a suitable candidate to realize a urinary diversion in place of an autologous intestinal segment. Further efforts will be performed in order to create a cylindrical-shaped hybrid membrane and to study its hydraulic behavior.

16.
Polymers (Basel) ; 14(6)2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35335556

RESUMO

The most common aortic valve diseases in adults are stenosis due to calcification and regurgitation. In pediatric patients, aortic pathologies are less common. When a native valve is surgically replaced by a prosthetic one, it is necessary to consider that the latter has a limited durability. In particular, current bioprosthetic valves have to be replaced after approximately 10 years; mechanical prostheses are more durable but require the administration of permanent anticoagulant therapy. With regard to pediatric patients, both mechanical and biological prosthetic valves have to be replaced due to their inability to follow patients' growth. An alternative surgical substitute can be represented by the acellular porcine aortic valve that exhibits less immunogenic risk and a longer lifespan. In the present study, an efficient protocol for the removal of cells by using detergents, enzyme inhibitors, and hyper- and hypotonic shocks is reported. A new detergent (Tergitol) was applied to replace TX-100 with the aim to reduce toxicity and maximize ECM preservation. The structural integrity and efficient removal of cells and nuclear components were assessed by means of histology, immunofluorescence, and protein quantification; biomechanical properties were also checked by tensile tests. After decellularization, the acellular scaffold was sterilized with a standard protocol and repopulated with bone marrow mesenchymal stem cells to analyze its biocompatibility profile.

17.
Cells ; 11(19)2022 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-36230907

RESUMO

Esophageal reconstruction through bio-engineered allografts that highly resemble the peculiar properties of the tissue extracellular matrix (ECM) is a prospective strategy to overcome the limitations of current surgical approaches. In this work, human esophagus was decellularized for the first time in the literature by comparing three detergent-enzymatic protocols. After decellularization, residual DNA quantification and histological analyses showed that all protocols efficiently removed cells, DNA (<50 ng/mg of tissue) and muscle fibers, preserving collagen/elastin components. The glycosaminoglycan fraction was maintained (70-98%) in the decellularized versus native tissues, while immunohistochemistry showed unchanged expression of specific ECM markers (collagen IV, laminin). The proteomic signature of acellular esophagi corroborated the retention of structural collagens, basement membrane and matrix-cell interaction proteins. Conversely, decellularization led to the loss of HLA-DR expression, producing non-immunogenic allografts. According to hydroxyproline quantification, matrix collagen was preserved (2-6 µg/mg of tissue) after decellularization, while Second-Harmonic Generation imaging highlighted a decrease in collagen intensity. Based on uniaxial tensile tests, decellularization affected tissue stiffness, but sample integrity/manipulability was still maintained. Finally, the cytotoxicity test revealed that no harmful remnants/contaminants were present on acellular esophageal matrices, suggesting allograft biosafety. Despite the different outcomes showed by the three decellularization methods (regarding, for example, tissue manipulability, DNA removal, and glycosaminoglycans/hydroxyproline contents) the ultimate validation should be provided by future repopulation tests and in vivo orthotopic implant of esophageal scaffolds.


Assuntos
Detergentes , Elastina , Colágeno , DNA/metabolismo , Esôfago/metabolismo , Glicosaminoglicanos/metabolismo , Humanos , Hidroxiprolina , Laminina , Proteômica
18.
Front Bioeng Biotechnol ; 10: 1042434, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36578513

RESUMO

Structural cardiac lesions are often surgically repaired using prosthetic patches, which can be biological or synthetic. In the current clinical scenario, biological patches derived from the decellularization of a xenogeneic scaffold are gaining more interest as they maintain the natural architecture of the extracellular matrix (ECM) after the removal of the native cells and remnants. Once implanted in the host, these patches can induce tissue regeneration and repair, encouraging angiogenesis, migration, proliferation, and host cell differentiation. Lastly, decellularized xenogeneic patches undergo cell repopulation, thus reducing host immuno-mediated response against the graft and preventing device failure. Porcine small intestinal submucosa (pSIS) showed such properties in alternative clinical scenarios. Specifically, the US FDA approved its use in humans for urogenital procedures such as hernia repair, cystoplasties, ureteral reconstructions, stress incontinence, Peyronie's disease, penile chordee, and even urethral reconstruction for hypospadias and strictures. In addition, it has also been successfully used for skeletal muscle tissue reconstruction in young patients. However, for cardiovascular applications, the results are controversial. In this study, we aimed to validate our decellularization protocol for SIS, which is based on the use of Tergitol 15 S 9, by comparing it to our previous and efficient method (Triton X 100), which is not more available in the market. For both treatments, we evaluated the preservation of the ECM ultrastructure, biomechanical features, biocompatibility, and final bioinductive capabilities. The overall analysis shows that the SIS tissue is macroscopically distinguishable into two regions, one smooth and one wrinkle, equivalent to the ultrastructure and biochemical and proteomic profile. Furthermore, Tergitol 15 S 9 treatment does not modify tissue biomechanics, resulting in comparable to the native one and confirming the superior preservation of the collagen fibers. In summary, the present study showed that the SIS decellularized with Tergitol 15 S 9 guarantees higher performances, compared to the Triton X 100 method, in all the explored fields and for both SIS regions: smooth and wrinkle.

19.
Biomimetics (Basel) ; 7(3)2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35997424

RESUMO

Human and animal pericardia are among the most widely exploited materials suitable to repair damaged tissues in the cardiovascular surgery context. Autologous, xenogeneic (chemically treated) and homologous pericardia are largely utilized, but they do exhibit some crucial drawbacks. Any tissue treated with glutaraldehyde is known to be prone to calcification in vivo, lacks regeneration potential, has limited durability, and can result in cytotoxicity. Moreover, autologous tissues have limited availability. Decellularized biological tissues represent a promising alternative: decellularization removes cellular and nuclear components from native tissues and makes them suitable for repopulation by autologous cells upon implantation into the body. The present work aims to assess the effects of a new detergent, i.e., Tergitol, for decellularizing bovine and porcine pericardia. The decellularization procedure successfully removed cells, while preserving the histoarchitecture of the extracellular matrix. No cytotoxic effect was observed. Therefore, decellularized pericardia showed potential to be used as scaffold for cardiovascular tissue regeneration.

20.
Front Bioeng Biotechnol ; 10: 912617, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36267444

RESUMO

Current surgical options for patients requiring esophageal replacement suffer from several limitations and do not assure a satisfactory quality of life. Tissue engineering techniques for the creation of customized "self-developing" esophageal substitutes, which are obtained by seeding autologous cells on artificial or natural scaffolds, allow simplifying surgical procedures and achieving good clinical outcomes. In this context, an appealing approach is based on the exploitation of decellularized tissues as biological matrices to be colonized by the appropriate cell types to regenerate the desired organs. With specific regard to the esophagus, the presence of a thick connective texture in the decellularized scaffold hampers an adequate penetration and spatial distribution of cells. In the present work, the Quantum Molecular Resonance® (QMR) technology was used to create a regular microchannel structure inside the connective tissue of full-thickness decellularized tubular porcine esophagi to facilitate a diffuse and uniform spreading of seeded mesenchymal stromal cells within the scaffold. Esophageal samples were thoroughly characterized before and after decellularization and microperforation in terms of residual DNA content, matrix composition, structure and biomechanical features. The scaffold was seeded with mesenchymal stromal cells under dynamic conditions, to assess the ability to be repopulated before its implantation in a large animal model. At the end of the procedure, they resemble the original esophagus, preserving the characteristic multilayer composition and maintaining biomechanical properties adequate for surgery. After the sacrifice we had histological and immunohistochemical evidence of the full-thickness regeneration of the esophageal wall, resembling the native organ. These results suggest the QMR microperforated decellularized esophageal scaffold as a promising device for esophagus regeneration in patients needing esophageal substitution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA