Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 789-799, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37955700

RESUMO

PURPOSE: To investigate associations between contrast sensitivity (CS) and vascular metrics on wide-field swept-source optical coherence tomography angiography (WF-SS-OCTA) in patients with retinal vein occlusion (RVO). METHODS: This prospectively recruited, cross-sectional observational study included RVO patients who underwent quantitative CS function (qCSF) testing and WF-SS-OCTA using 3 × 3, 6 × 6, and 12 × 12 mm angiograms on the same day. The study measured several qCSF outcomes and WF-SS-OCTA vascular metrics, including vessel density (VD), vessel skeletonized density (VSD), and foveal avascular zone (FAZ). The data were analyzed using multivariable regression analysis controlling for age and central subfield thickness (CST). RESULTS: A total of 43 RVO eyes of 43 patients and 30 fellow eyes were included. In RVO eyes, multiple vascular metrics were associated with CS outcomes but not visual acuity (VA). On 12 × 12 images, CS thresholds at 1 cpd, 1.5 cpd, and 3 cpd were significantly associated with VD and VSD, but VA was not. When comparing standardized regression coefficients, we found that vascular metrics had a larger effect size on CS than on VA. For instance, the standardized beta coefficient for FAZ area and CS at 6 cpd (ß* = - 0.46, p = 0.007) was larger than logMAR VA (ß* = 0.40, p = 0.011). CONCLUSION: Microvascular changes on WF-SS-OCTA in RVO had a larger effect size on CS than VA. This suggests CS may better reflect the microvascular changes of RVO compared to VA. qCSF-measured CS might be a valuable adjunct functional metric in evaluating RVO patients.


Assuntos
Macula Lutea , Oclusão da Veia Retiniana , Humanos , Sensibilidades de Contraste , Oclusão da Veia Retiniana/diagnóstico , Tomografia de Coerência Óptica , Estudos Transversais , Angiografia
2.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2111-2120, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38376563

RESUMO

PURPOSE: To investigate the impact of anti-VEGF therapy on vascular metrics in eyes with macular edema secondary to central retinal vein occlusion (CRVO) using wider field swept-source OCT angiography (WF SS-OCTA). METHODS: We included 23 eyes with macular edema associated with non-ischemic CRVO from 22 patients treated with anti-VEGF therapy (median number of injections: 5 [2-9]). Changes in vessel density (VD), vessel skeletonized density (VSD), and foveal avascular zone (FAZ) parameters were measured using WF SS-OCTA. Visual acuity (VA) and central subfield thickness (CST) were also measured. RESULTS: Median CST decreased significantly from 369 µm (305-531) to 267 µm (243-300, p < 0.001). VD and VSD parameters in 12 × 12 mm images showed significant reductions. For instance, VSD in the whole retina decreased from a median of 13.37 (11.22-13.74) to 11.29 (9.36-12.97, p = 0.013). Additionally, a significant increase in FAZ circularity was found, suggesting improved microvascular integrity. Significant inverse correlations were found between the number of anti-VEGF injections and all VSD and VD parameters on the 12 × 12 mm images (p < 0.05). Notably, the reductions in VSD and VD on 12 × 12 mm angiograms in the deep capillary plexus (DCP) after each injection significantly correlated with increased logMAR VA (worse VA). CONCLUSION: Anti-VEGF therapy in CRVO patients not only mitigates macular edema but also alters the overall microvascular morphology and functionality as revealed by WF SS-OCTA.


Assuntos
Inibidores da Angiogênese , Ranibizumab , Oclusão da Veia Retiniana , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Angiogênese/uso terapêutico , Inibidores da Angiogênese/administração & dosagem , Bevacizumab/uso terapêutico , Bevacizumab/administração & dosagem , Angiofluoresceinografia/métodos , Seguimentos , Fundo de Olho , Injeções Intravítreas , Edema Macular/tratamento farmacológico , Edema Macular/diagnóstico , Edema Macular/etiologia , Edema Macular/fisiopatologia , Ranibizumab/administração & dosagem , Receptores de Fatores de Crescimento do Endotélio Vascular/uso terapêutico , Receptores de Fatores de Crescimento do Endotélio Vascular/antagonistas & inibidores , Receptores de Fatores de Crescimento do Endotélio Vascular/administração & dosagem , Oclusão da Veia Retiniana/tratamento farmacológico , Oclusão da Veia Retiniana/diagnóstico , Oclusão da Veia Retiniana/fisiopatologia , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Acuidade Visual
3.
J Neuroophthalmol ; 44(3): 301-307, 2024 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-39167561

RESUMO

BACKGROUND: With the SARS-CoV-2 pandemic (COVID-19), data on central and peripheral nervous system involvement, including those causing cranial nerve 6 (CN6) palsy, have been limited to case reports. To extract clinically relevant features of COVID-19-related CN6 palsy, we report on a recurrent pediatric case and analysis of reported cases associated with infection or immunization. METHODS: A PubMed search revealed 18 cases of isolated CN6 palsy in addition to the index case (n = 19). Clinical characteristics, workup, and temporal associations between systemic symptoms onset or vaccination, symptoms onset, and resolution were compiled and analyzed. RESULTS: The median age of CN6 onset was 43 years (interquartile range [IQR]: 28-52). Sixteen cases (84.2%) were associated with COVID-19 illness and 3 (15.8%) were associated with COVID-19 vaccination. Four cases (23.5%) had positive neuroimaging findings. The median latency from first COVID-19 symptoms or vaccination to onset of CN6 palsy was 6 days (IQR: 2.3-16), and the median time from onset to resolution was 30 days (IQR: 14-60). Latency to onset of CN6 palsy was significantly and directly associated with time to resolution (R 2 = 0.401, P = 0.010). Patients who had a positive SARS-CoV-2 antibody test had significantly longer days from symptoms to onset (6.0 vs 24.5, P = 0.030), and patients with a positive SARS-CoV-2 polymerase chain reaction test had a significantly shorter time to resolution (17.50 vs 90, P = 0.042). CONCLUSIONS: Isolated CN6 palsy from COVID-19 is rare, can occur in infants as young as 7 months, and can be recurrent. Longer latency from systemic symptoms onset portends greater recovery times, and this relationship may reflect multiple mechanisms by which COVID-19 (and/or an immune response thereto) causes cranial neuropathies with direct clinical relevance.


Assuntos
Doenças do Nervo Abducente , COVID-19 , Recidiva , SARS-CoV-2 , Humanos , COVID-19/complicações , COVID-19/epidemiologia , COVID-19/diagnóstico , Doenças do Nervo Abducente/etiologia , Doenças do Nervo Abducente/diagnóstico , Lactente , Masculino , Feminino , Pandemias
4.
Graefes Arch Clin Exp Ophthalmol ; 261(7): 1835-1859, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36680613

RESUMO

PURPOSE: Data from healthy eyes is needed to interpret optical coherence tomography angiography (OCTA) findings. However, very little normative data is available for wide-field swept-source OCTA (WF SS-OCTA), particularly 12 × 12-mm and disc-centered angiograms. Therefore, we aim to report quantitative metrics in a large sample of control eyes. METHODS: In this cross-sectional observational study, 482 eyes of 375 healthy adults were imaged on the 100 kHz Zeiss PLEX® Elite 9000 using protocols centered on the fovea (3 × 3, 6 × 6, and 12 × 12-mm) and optic disc (6 × 6 and 12 × 12-mm) between December 2018 and January 2022. The ARI Network (Zeiss Portal v5.4) was used to calculate vessel density (VD) and vessel skeletonized density (VSD) in the superficial capillary plexus, deep capillary plexus, and whole retina, as well as foveal avascular zone (FAZ) parameters. Mixed-effect multiple linear regression models were used for statistical analysis. RESULTS: The subjects' median age was 55 (38-63) years, and 201 (53.6%) were female. Greater age and worse best-corrected visual acuity (BCVA) were associated with significantly lower VD and VSD (p < 0.05). VD and VSD differed based on race and cataract status, but not sex, on some scan protocols (p < 0.05). FAZ circularity decreased with age, and FAZ dimensions differed based on race and ethnicity in certain scan protocols. CONCLUSIONS: We report a large database of parafoveal and peripapillary vascular metrics in several angiogram sizes. In referencing these values, researchers must consider characteristics such as age, race, and BCVA, but will have a valuable point of comparison for OCTA measurements in pathologic settings.


Assuntos
Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Masculino , Angiofluoresceinografia/métodos , Vasos Retinianos/patologia , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Benchmarking , Acuidade Visual
5.
Graefes Arch Clin Exp Ophthalmol ; 261(11): 3113-3124, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37278906

RESUMO

PURPOSE: To evaluate the relationship between contrast sensitivity (CS) and widefield swept-source optical coherence tomography angiography (WF SS-OCTA) vascular metrics in diabetic macular edema (DME) was the purpose. METHODS: This prospectively enrolled cross-sectional observational study included 61 eyes of 48 patients that were tested with the quantitative CS function (qCSF) test on the same day as imaging with WF SS-OCTA (PLEX® Elite 9000, Carl Zeiss Meditec) 3 × 3, 6 × 6, and 12 × 12 mm scans. Outcomes included visual acuity (VA) and multiple qCSF metrics. Vascular metrics included vessel density (VD) and vessel skeletonized density (VSD) in the superficial (SCP) and deep capillary plexus (DCP) and whole retina (WR) and foveal avascular zone (FAZ) parameters. Mixed effects multivariable linear regression models controlling for age, lens status, and diabetic retinopathy stage were performed. Standardized beta coefficients were calculated by refitting the standardized data. RESULTS: SS-OCTA metrics had a significant association with CS and VA. The effect size of OCTA metrics was larger on CS compared to VA. For example, the standardized beta coefficients for VSD and CS at 3 cpd (ßSCP = 0.76, ßDCP = 0.71, ßWR = 0.72, p < 0.001) were larger than those for VA (ßSCP = - 0.55, p < 0.001; ßDCP = - 0.43, p = 0.004; ßWR = - 0.50, p < 0.001). On 6 × 6 mm images, AULCSF, CS at 3 cpd, and CS at 6 cpd were significantly associated with VD and VSD in all three slab types (SCP, DCP, and WR), while VA was not. CONCLUSION: Structure-function associations in patients with DME leveraging the qCSF device suggest microvascular changes on WF SS-OCTA are associated with larger changes in contrast sensitivity than VA.

6.
Graefes Arch Clin Exp Ophthalmol ; 261(3): 631-639, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36149494

RESUMO

PURPOSE: To investigate structure-function associations between retinal thickness, visual acuity (VA), and contrast sensitivity (CS), using the quantitative contrast sensitivity function (qCSF) method in patients with idiopathic epiretinal membrane (ERM). METHODS: Retrospective, cross-sectional observational study. Patients with a diagnosis of idiopathic ERM were included. Patients underwent complete ophthalmic examination, spectral-domain optical coherence tomography imaging (SD-OCT) (SPECTRALIS® Heidelberg), and CS testing using the qCSF method. Outcomes included area under the log CSF (AULCSF), contrast acuity (CA), and CS thresholds at 1, 1.5, 3, 6, 12, and 18 cycles per degree (cpd). RESULTS: A total of 102 eyes of 79 patients were included. Comparing standardized regression coefficients, retinal thickness in most ETDRS sectors was associated with larger reductions in AULCSF, CA, and CS thresholds at 3 and 6 cpd than those in logMAR VA. These differences in effect on VA and CS metrics were more pronounced in the central subfield and inner ETDRS sectors. Among the retinal layers, increased INL thickness had the most detrimental effect on visual function, being significantly associated with reductions in logMAR VA, AULCSF, CA, and CS thresholds at 3 and 6 cpd (all p < .01), as well as at 1.5 and 12 cpd (p < .05). CONCLUSION: Retinal thickness seems to be associated with larger reductions in contrast sensitivity than VA in patients with ERM. Measured with the qCSF method, contrast sensitivity may serve as a valuable adjunct visual function metric for patients with ERM.


Assuntos
Membrana Epirretiniana , Humanos , Membrana Epirretiniana/diagnóstico , Sensibilidades de Contraste , Estudos Retrospectivos , Estudos Transversais , Retina
7.
J Neuroophthalmol ; 2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37647242

RESUMO

BACKGROUND: With the SARS-CoV-2 pandemic (COVID-19), data on central and peripheral nervous system involvement, including those causing cranial nerve 6 (CN6) palsy, have been limited to case reports. To extract clinically relevant features of COVID-19-related CN6 palsy, we report on a recurrent pediatric case and analysis of reported cases associated with infection or immunization. METHODS: A PubMed search revealed 18 cases of isolated CN6 palsy in addition to the index case (n = 19). Clinical characteristics, workup, and temporal associations between systemic symptoms onset or vaccination, symptoms onset, and resolution were compiled and analyzed. RESULTS: The median age of CN6 onset was 43 years (interquartile range [IQR]: 28-52). Sixteen cases (84.2%) were associated with COVID-19 illness and 3 (15.8%) were associated with COVID-19 vaccination. Four cases (23.5%) had positive neuroimaging findings. The median latency from first COVID-19 symptoms or vaccination to onset of CN6 palsy was 6 days (IQR: 2.3-16), and the median time from onset to resolution was 30 days (IQR: 14-60). Latency to onset of CN6 palsy was significantly and directly associated with time to resolution (R2 = 0.401, P = 0.010). Patients who had a positive SARS-CoV-2 antibody test had significantly longer days from symptoms to onset (6.0 vs 24.5, P = 0.030), and patients with a positive SARS-CoV-2 polymerase chain reaction test had a significantly shorter time to resolution (17.50 vs 90, P = 0.042). CONCLUSIONS: Isolated CN6 palsy from COVID-19 is rare, can occur in infants as young as 7 months, and can be recurrent. Longer latency from systemic symptoms onset portends greater recovery times, and this relationship may reflect multiple mechanisms by which COVID-19 (and/or an immune response thereto) causes cranial neuropathies with direct clinical relevance.

8.
Clin Gastroenterol Hepatol ; 20(4): 756-765.e3, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33549871

RESUMO

BACKGROUND & AIMS: Tethered capsule endomicroscopy (TCE) involves swallowing a small tethered pill that implements optical coherence tomography (OCT) imaging, procuring high resolution images of the whole esophagus. Here, we demonstrate and evaluate the feasibility and safety of TCE and a portable OCT imaging system in patients with Barrett's esophagus (BE) in a multi-center (5-site) clinical study. METHODS: Untreated patients with BE as per endoscopic biopsy diagnosis were eligible to participate in the study. TCE procedures were performed in unsedated patients by either doctors or nurses. After the capsule was swallowed, the device continuously obtained 10-µm-resolution cross-sectional images as it traversed the esophagus. Following imaging, the device was withdrawn through mouth, and disinfected for subsequent reuse. BE lengths were compared to endoscopy findings when available. OCT-TCE images were compared to volumetric laser endomicroscopy (VLE) images from a patient who had undergone VLE on the same day as TCE. RESULTS: 147 patients with BE were enrolled across all sites. 116 swallowed the capsule (79%), 95/114 (83.3%) men and 21/33 (63.6%) women (P = .01). High-quality OCT images were obtained in 104/111 swallowers (93.7%) who completed the procedure. The average imaging duration was 5.55 ± 1.92 minutes. The mean length of esophagus imaged per patient was 21.69 ± 5.90 cm. A blinded comparison of maximum extent of BE measured by OCT-TCE and EGD showed a strong correlation (r = 0.77-0.79). OCT-TCE images were of similar quality to those obtained by OCT-VLE. CONCLUSIONS: The capabilities of TCE to be used across multiple sites, be administered to unsedated patients by either physicians or nurses who are not expert in OCT-TCE, and to rapidly and safely evaluate the microscopic structure of the esophagus make it an emerging tool for screening and surveillance of BE patients. Clinical trial registry website and trial number: NCT02994693 and NCT03459339.


Assuntos
Esôfago de Barrett , Neoplasias Esofágicas , Esôfago de Barrett/diagnóstico por imagem , Esôfago de Barrett/patologia , Biópsia , Neoplasias Esofágicas/patologia , Esofagoscopia/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia de Coerência Óptica/métodos
9.
Lasers Surg Med ; 54(7): 935-944, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35708124

RESUMO

BACKGROUND/OBJECTIVES: Optical coherence tomography (OCT) uses low coherence interferometry to obtain depth-resolved tissue reflectivity profiles (M-mode) and transverse beam scanning to create images of two-dimensional tissue morphology (B-mode). Endoscopic OCT imaging probes typically employ proximal or distal mechanical beam scanning mechanisms that increase cost, complexity, and size. Here, we demonstrate in the gastrointestinal (GI) tracts of unsedated human patients, that a passive, single-fiber probe can be used to guide device placement, conduct device-tissue physical contact sensing, and obtain two-dimensional OCT images via M-to-B-mode conversion. MATERIALS AND METHODS: We designed and developed ultrasmall, manually scannable, side- and forward-viewing single fiber-optic probes that can capture M-mode OCT data. Side-viewing M-mode OCT probes were incorporated into brush biopsy devices designed to harvest the microbiome and forward-viewing M-mode OCT probes were integrated into devices that measure intestinal potential difference (IPD). The M-mode OCT probe-coupled devices were utilized in the GI tract in six unsedated patients in vivo. M-mode data were converted into B-mode images using an M-to-B-mode conversion algorithm. The effectiveness of physical contact sensing by the M-mode OCT probes was assessed by comparing the variances of the IPD values when the probe was in physical contact with the tissue versus when it was not. The capacity of forward- and side-viewing M-mode OCT probes to produce high-quality B-mode images was compared by computing the percentages of the M-to-B-mode images that showed close contact between the probe and the luminal surface. Passively scanned M-to-B-mode images were qualitatively compared to B-mode images obtained by mechanical scanning OCT tethered capsule endomicroscopy (TCE) imaging devices. RESULTS: The incorporation of M-mode OCT probes in these nonendoscopic GI devices safely and effectively enabled M-mode OCT imaging, facilitating real-time device placement guidance and contact sensing in vivo. Results showed that M-mode OCT contact sensing improved the variance of IPD measurements threefold and side-viewing probes increased M-to-B-mode image visibility by 10%. Images of the esophagus, stomach, and duodenum generated by the passively scanned probes and M-to-B-mode conversion were qualitatively superior to B-mode images obtained by mechanically scanning OCT TCE devices. CONCLUSION: These results show that passive, single optical fiber OCT probes can be effectively utilized for nonendoscopic device placement guidance, device contact sensing, and two-dimensional morphologic imaging in the human GI tract in vivo. Due to their small size, lower cost, and reduced complexity, these M-mode OCT probes may provide an easier avenue for the incorporation of OCT functionality into endoscopic/nonendoscopic devices.


Assuntos
Tecnologia de Fibra Óptica , Tomografia de Coerência Óptica , Biópsia , Endoscópios , Endoscopia , Humanos
12.
J Card Surg ; 34(5): 318-322, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30900354

RESUMO

BACKGROUND: The fate of the spared bicuspid aortic valve in patients undergoing ascending aortic aneurysm surgery is relatively unknown. Our institutional policy has been to replace all aortic valves with significant abnormalities, as evidenced by intraoperative transesophageal echocardiography or direct visual inspection. In this study, we elaborate our experience regarding the long-term fate of preserved bicuspid aortic valves after ascending aortic aneurysm extirpation. MATERIALS AND METHODS: From 2000 to 2018, 407 consecutive ascending aortic aneurysm patients with concomitant bicuspid aortic valves underwent surgery by a single surgeon at our institution. Among these, 23 (5.65%) patients did not have their valve replaced, forming the study group. Postoperative and preoperative echocardiograms were compared to determine changes in valve function. RESULTS: Follow-up was complete in 100% of patients. The average time between preoperative and postoperative echocardiograms was 4.50 ± 4.09 years (0.19-15.63). Aortic stenosis or regurgitation changed from none to mild in 5 (21.7%) of patients, with an average echocardiographic interval follow-up of 3.08 years, and from none to severe in 2 (8.7%), with an interval of 11.7 years. One patient required reoperation, including aortic valve replacement, during follow-up. CONCLUSION: Bicuspid aortic valves free of aortic stenosis or insufficiency before surgery and "healthy" appearing at surgery can safely be preserved.


Assuntos
Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas , Tratamentos com Preservação do Órgão/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Valva Aórtica/fisiologia , Doença da Válvula Aórtica Bicúspide , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
13.
J Vitreoretin Dis ; 8(4): 428-434, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39148569

RESUMO

Purpose: To describe 2 cases in which video endoscopy was combined with heads-up 3-dimensional (3D) visualization. Methods: The imaging modalities of the heads-up 3D visualization system and video endoscopy were combined by converting the endoscope's S-Video output into a high-definition multimedia interface. The technique was used in 2 cases that included lens dislocation and endophthalmitis. Results: In the 2 cases, the heads-up split-screen view simplified the surgical setup. Simultaneously viewing the endoscopic image and widefield 3D image anecdotally appeared to improve ergonomics, help keep the probe oriented, and assist in guiding surgical movements endoscopically. Conclusions: These cases show the advantages of a heads-up 3D system to simultaneously view endoscopic and widefield images during ophthalmic endoscopy in vitreoretinal surgery.

14.
Ophthalmic Genet ; 45(5): 435-440, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38953718

RESUMO

PURPOSE: Bardet-Biedl Syndrome (BBS) is a rare autosomal recessive ciliopathy. Within corneal development, primary cilia serve a critical role. We sought to investigate the association of BBS with corneal astigmatism among a cohort of patients with BBS. METHODS: This was a cross-sectional, retrospective study performed at a pediatric ophthalmology department of a tertiary hospital. The study enrolled 45 patients with genetically confirmed Bardet-Biedl syndrome, encompassing a total of 90 eyes observed from February 2011 to August 2021. Spherical and cylindrical refractive errors and keratometry outcome measures, including diopter (D) values at the flattest and steepest axes, were recorded. Corneal astigmatism of greater than 3D is considered extreme corneal astigmatism based on previously published data. RESULTS: Among 45 patients (M:26; F:19), the mean age was 16.4 ± 8.2 years, and the mean best-corrected visual acuity was 20/60. The most common molecular diagnosis was BBS1, seen in 24 of 45 (53.3%). Among all the patients, the mean spherical refractive error was -2.9 ± 3.8D. The mean cylindrical refractive error was 2.6 ± 1.5D. The mean keratometry values at the flattest axis was 43.5 ± 5.3D (39.4-75.0) and at the steepest axis was 47.2 ± 7.3D(41.5-84.0). Among all the patients with BBS, the mean corneal astigmatism was 3.7 ± 1.0D(0.5-7.1), which is considered extreme. CONCLUSION: A cohort of individuals with BBS demonstrated high corneal astigmatism. These results suggest an association between corneal astigmatism and primary ciliary dysfunction and may assist in clinical management and future therapeutic targets among BBS and other corneal disorders.


Assuntos
Síndrome de Bardet-Biedl , Erros de Refração , Acuidade Visual , Humanos , Síndrome de Bardet-Biedl/genética , Síndrome de Bardet-Biedl/diagnóstico , Síndrome de Bardet-Biedl/complicações , Masculino , Feminino , Estudos Retrospectivos , Criança , Adolescente , Estudos Transversais , Adulto , Acuidade Visual/fisiologia , Erros de Refração/fisiopatologia , Adulto Jovem , Astigmatismo/fisiopatologia , Astigmatismo/genética , Astigmatismo/diagnóstico , Pré-Escolar , Refração Ocular/fisiologia
15.
Ophthalmic Surg Lasers Imaging Retina ; 55(4): 212-219, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38319059

RESUMO

BACKGROUND AND OBJECTIVE: We sought to establish normative quantitative contrast sensitivity function (qCSF) values in healthy adult eyes and investigate the effect of age on qCSF. PATIENTS AND METHODS: Healthy eyes underwent qCSF testing (adaptive sensory technology) and Snellen's visual acuity (VA). Descriptive statistics and mixed-effects multivariable linear regressions were evaluated. RESULTS: A total of 334 eyes (290 patients) with median age 61 years (range 21 to 88) had qCSF values as follows: area under the log contrast sensitivity function curve: 1.18; contrast acuity: 1.32; contrast sensitivity (CS) at 1 cycle per degree (cpd): 1.32; CS at 1.5 cpd: 1.37; CS at 3 cpd: 1.38; CS at 6 cpd: 1.20; CS at 12 cpd: 0.69; CS at 18 cpd: 0.22. Linear reductions in qCSF values per decade of age ranged from -0.02 to -0.07 vs 0.01 for visual acuity (VA). Age had a greater effect on the majority of qCSF values than VA (beta standardized regression coefficient ranged from -0.309 to -0.141 for qCSF values vs 0.177 for VA). CONCLUSIONS: We herein establish a normative database for qCSF and quantify the effect of age on qCSF values, adding evidence towards the validation of qCSF as a clinical endpoint. [Ophthalmic Surg Lasers Imaging Retina 2024;55:212-219.].


Assuntos
Envelhecimento , Sensibilidades de Contraste , Acuidade Visual , Humanos , Sensibilidades de Contraste/fisiologia , Adulto , Feminino , Masculino , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Idoso , Adulto Jovem , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Voluntários Saudáveis , Valores de Referência , Bases de Dados Factuais
16.
Br J Ophthalmol ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38719345

RESUMO

PURPOSE: To investigate structure-function associations between contrast sensitivity (CS) and widefield swept-source optical coherence tomography angiography (WF SS-OCTA) vascular metrics across stages of non-proliferative (NPDR) and proliferative diabetic retinopathy (PDR), without diabetic macular oedema. METHODS: Prospective cross-sectional study in 140 eyes of 99 patients: 33 mild NPDR, 24 moderate/severe NPDR, 15 PDR, 33 diabetic without DR (DMnoDR) and 46 control eyes. Mixed-effects multivariable regression models to evaluate associations between quantitative contrast sensitivity function (Adaptive Sensory Technology) and vessel density (VD) and vessel skeletonised density (VSD) in the superficial capillary plexus (SCP) and deep capillary plexus (DCP) on same-day imaging with WF SS-OCTA (Plex Elite 9000, Carl Zeiss Meditec). RESULTS: Standardised ß coefficients for area under the logarithm of contrast sensitivity function curve (AULCSF) versus visual acuity (VA) at 3×3 mm scans: SCP VSD (ß=0.32, p<0.001 vs -0.18, p=0.044), DCP VSD (ß=0.30, p<0.001 vs -0.21, p=0.02), SCP VD (ß=0.25, p=0.004 vs -0.13, p=0.129), DCP VD (ß=0.26, p=0.003 vs -0.19, p=0.034). AULCSF was significantly reduced in mild NPDR (ß=-0.28, p<0.001) and DMnoDR (ß=-0.19, p=0.005) versus controls, while VA was not significantly different. AULCSF performed better than VA in differentiating between controls and DMnoDR (0.69 vs 0.50), controls and mild NPDR (0.76 vs 0.61) and controls and moderate/severe NPDR (0.89 vs 0.73). CONCLUSIONS: DR-induced microvascular changes on OCTA are associated with larger changes on CS than in VA. CS is affected earlier than VA in the course of DR and performed better in discriminating between controls, DMnoDR and across DR stages.

17.
J Vitreoretin Dis ; 8(5): 533-539, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39351501

RESUMO

Introduction: To investigate whether there is visual function impairment in patients with posterior vitreous detachment (PVD) using the active-learning quantitative contrast sensitivity function test. Methods: In this cross-sectional study, contrast sensitivity was measured in eyes with PVD and eyes without PVD using the quantitative contrast sensitivity function algorithm on the Adaptive Sensory Technology platform. Outcomes included the area under the log contrast sensitivity function curve, contrast acuity, and contrast sensitivity thresholds at 1 to 18 cycles per degree (cpd). Snellen visual acuity (VA) was also measured. Mixed-effects multiple linear regression analyses were performed to evaluate the association between the presence of PVD and visual function, controlling for age and lens status. Results: The cohort comprised 232 healthy eyes of 205 participants; of these, 80 eyes of 69 patients had PVD. There was no significant association between VA and PVD presence. However, PVD was significantly associated with decreased contrast sensitivity thresholds at 1.5 cpd (ß, -0.058; P = .003) and 3 cpd (ß, -0.067; P = .004). Contrast sensitivity thresholds at lower (1 cpd) or higher (6, 12, 18 cpd) spatial frequencies did not significantly correlate with PVD presence. Even in the subgroup of symptomatic PVD eyes, VA was not significantly decreased, while quantitative contrast sensitivity function outcomes showed visual function deficits at low spatial frequencies (1.5 cpd and 3 cpd). Conclusions: Contrast sensitivity measured with the quantitative contrast sensitivity function test showed visual function deficits in eyes with PVD that would have been missed with VA testing alone. Incorporating this test in the retina clinic might offer a more comprehensive functional assessment of eyes with PVD, serving as an adjunct outcome metric in clinical decision-making.

18.
Ophthalmic Surg Lasers Imaging Retina ; 55(7): 374-382, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38531003

RESUMO

BACKGROUND AND OBJECTIVE: Our objective was to assess baseline widefield swept-source optical coherence tomography angiography (WF SSOCTA) microvascular metrics as predictors for the number of anti-vascular endothelial growth factor (VEGF) injections and visual acuity (VA) at 12-months follow-up in patients with retinal vein occlusion (RVO). PATIENTS AND METHODS: This was a prospective study including 49 RVO eyes from 49 patients who had not received an anti-VEGF injection for at least 3 months prior to imaging. Microvascular metrics from 6×6-mm and 12×12-mm angiograms were assessed using linear regression models, adjusting for age. RESULTS: Reductions in the vessel density (VD) and vessel skeletonized density (VSD) vascular metrics were associated both with a higher number of anti-VEGF injections at all follow-up time points and reduced VA 12 months after imaging in all RVO eyes. CONCLUSIONS: WF SS-OCTA VD and VSD micro-vascular metrics at baseline can prognosticate VA and number of anti-VEGF injections required at 3, 6, and 12 months in RVO eyes. [Ophthalmic Surg Lasers Imaging Retina 2024;55:374-382.].


Assuntos
Inibidores da Angiogênese , Angiofluoresceinografia , Injeções Intravítreas , Oclusão da Veia Retiniana , Tomografia de Coerência Óptica , Fator A de Crescimento do Endotélio Vascular , Acuidade Visual , Humanos , Oclusão da Veia Retiniana/tratamento farmacológico , Oclusão da Veia Retiniana/diagnóstico , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Inibidores da Angiogênese/uso terapêutico , Inibidores da Angiogênese/administração & dosagem , Masculino , Feminino , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Angiofluoresceinografia/métodos , Idoso , Pessoa de Meia-Idade , Seguimentos , Vasos Retinianos/diagnóstico por imagem , Fundo de Olho , Ranibizumab/administração & dosagem , Ranibizumab/uso terapêutico , Idoso de 80 Anos ou mais
19.
Ophthalmic Surg Lasers Imaging Retina ; 55(9): 494-502, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38917397

RESUMO

BACKGROUND AND OBJECTIVE: To evaluate the association between widefield swept-source optical coherence tomography angiography (WF SS-OCTA) and visual function in healthy eyes. PATIENTS AND METHODS: Fifty-seven eyes of 45 patients were evaluated with visual acuity (VA), contrast sensitivity (CS), and WF SS-OCTA (3 × 3, 6 × 6, and 12 × 12 mm images) on the same day. Mixed-effects multivariable regression analyses were performed. RESULTS: Contrast sensitivity metrics, including CS between 6 to 18 cycles per degree (cpd) and area under the logarithm CS function, were significantly associated with vessel density (VD) and vessel skeletonized density (VSD), whereas VA was not. The largest effect size was between CS at 18 cpd and VD (ß = 0.41, P = 0.007) and VSD (ß = 0.42, P = 0.006) on 12 × 12 mm images. CONCLUSIONS: Reduced VSD and VD on WF SSOCTA was significantly associated with decreased CS, whereas VA was not. These results suggest CS could serve as a screening tool for early stage retinal and neurologic disorders. [Ophthalmic Surg Lasers Imaging Retina 2024;55:494-502.].


Assuntos
Sensibilidades de Contraste , Angiofluoresceinografia , Vasos Retinianos , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Tomografia de Coerência Óptica/métodos , Acuidade Visual/fisiologia , Masculino , Feminino , Sensibilidades de Contraste/fisiologia , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/fisiologia , Angiofluoresceinografia/métodos , Adulto , Pessoa de Meia-Idade , Voluntários Saudáveis , Fundo de Olho , Adulto Jovem , Idoso
20.
Invest Ophthalmol Vis Sci ; 65(8): 29, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39023441

RESUMO

Purpose: To longitudinally investigate the changes in intraretinal microvascular abnormalities (IRMAs) over time, employing swept-source optical coherence tomography angiography in eyes with diabetic retinopathy. Methods: In this retrospective, longitudinal study, we evaluated 12 × 12-mm swept-source optical coherence tomography angiography centered on the macula at baseline and last available follow-up visit for (1) IRMA changes during follow-up, defined as (a) stable, (b) regressed, (c) obliterated, and (d) progressed; and the (2) development of new neovascularization (NV) and their origins. Competing-risk survival analysis was used to assess the factors associated with these changes. Results: In total, 195 eyes from 131 participants with diabetic retinopathy were included. Stable, regressed, obliterated, and progressed IRMA were observed in 65.1%, 12.8%, 11.3%, and 19% of eyes with diabetic retinopathy, respectively. Anti-VEGF injections during the follow-up periods and a slower increase of foveal avascular zone were associated with IRMA regression (P < 0.001 and P = 0.039). Obliterated IRMA were correlated with previous panretinal photocoagulation (P < 0.001) and a lower deep capillary plexus vessel density at baseline (P = 0.007), as well as with follow-up anti-VEGF injections (P = 0.025). A higher baseline ischemia index (ISI) and panretinal photocoagulation during the follow-up periods were associated with IRMA progression (P = 0.049 and P < 0.001). A faster increase in ISI predicted the development of NV elsewhere (NVE) from veins (P < 0.001). No significant factors were found to be associated with NVE originating from IRMA. Conclusions: Changes in IRMA closely correlated with the severity of retinal ischemia and treatment. Notably, our study confirmed the potential, yet relatively rare, development of NVE from IRMA in a large cohort; however, the risk factors associated with this transformation require further exploration.


Assuntos
Retinopatia Diabética , Angiofluoresceinografia , Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Retinopatia Diabética/diagnóstico , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Vasos Retinianos/patologia , Vasos Retinianos/diagnóstico por imagem , Angiofluoresceinografia/métodos , Seguimentos , Idoso , Neovascularização Retiniana/diagnóstico , Neovascularização Retiniana/diagnóstico por imagem , Acuidade Visual , Microvasos/patologia , Microvasos/diagnóstico por imagem , Fundo de Olho , Progressão da Doença , Estudos Longitudinais , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA