RESUMO
Advances in left ventricular assist device (LVAD) therapy have resulted in increasing numbers of adult LVAD recipients in the community. However, device failure, stroke, bleeding, LVAD thrombosis and systemic infection can be life-threatening emergencies. Currently, four LVAD systems are implanted in six UK transplant centres, each of which provides device-specific information to local emergency services. This has resulted in inconsistent availability and content of information with the risks of delayed or inappropriate decision-making. In order to improve patient safety, a consortium of UK healthcare professionals with expertise in LVADs developed universally applicable prehospital emergency algorithms. Guidance was framed as closely as possible on the standard ABCDE approach to the assessment of critically ill patients.
Assuntos
Algoritmos , Ambulâncias , Serviços Médicos de Emergência/normas , Tratamento de Emergência/normas , Insuficiência Cardíaca/terapia , Coração Auxiliar , Emergências , Falha de Equipamento , Humanos , Reino UnidoRESUMO
The aim of this study was to elucidate the dynamic characteristics of the Thoratec HeartMate II (HMII) and the HeartWare HVAD (HVAD) left ventricular assist devices (LVADs) under clinically representative in vitro operating conditions. The performance of the two LVADs were compared in a normothermic, human blood-filled mock circulation model under conditions of steady (nonpulsatile) flow and under simulated physiologic conditions. These experiments were repeated using 5% dextrose in order to determine its suitability as a blood analog. Under steady flow conditions, for the HMII, approximately linear inverse LVAD differential pressure (H) versus flow (Q) relationships were observed with good correspondence between the results of blood and 5% dextrose under all conditions except at a pump speed of 9000 rpm. For the HVAD, the corresponding relationships were inverse curvilinear and with good correspondence between the blood-derived and 5% dextrose-derived relationships in the flow rate range of 2-6 L/min and at pump speeds up to 3000 rpm. Under pulsatile operating conditions, for each LVAD operating at a particular pump speed, an counterclockwise loop was inscribed in the HQ domain during a simulated cardiac cycle (HQ loop); this showed that there was a variable phase relationship between LVAD differential pressure and LVAD flow. For both the HMII and HVAD, increasing pump speed was associated with a right-hand and upward shift of the HQ loop and simulation of impairment of left ventricular function was associated with a decrease in loop area. During clinical use, not only does the pressure differential across the LVAD and its flow rate vary continuously, but their phase relationship is variable. This behavior is inadequately described by the widely accepted representation of a plot of pressure differential versus flow derived under steady conditions. We conclude that the dynamic HQ loop is a more meaningful representation of clinical operating conditions than the widely accepted steady flow HQ curve.
Assuntos
Coração Auxiliar , Fluxo Pulsátil , Simulação por Computador , Hemodinâmica , Humanos , Hidrodinâmica , Modelos Cardiovasculares , Pressão , Função Ventricular EsquerdaRESUMO
BACKGROUND: Dilated cardiomyopathy and hypertrophic cardiomyopathy arise from mutations in many genes. TTN, the gene encoding the sarcomere protein titin, has been insufficiently analyzed for cardiomyopathy mutations because of its enormous size. METHODS: We analyzed TTN in 312 subjects with dilated cardiomyopathy, 231 subjects with hypertrophic cardiomyopathy, and 249 controls by using next-generation or dideoxy sequencing. We evaluated deleterious variants for cosegregation in families and assessed clinical characteristics. RESULTS: We identified 72 unique mutations (25 nonsense, 23 frameshift, 23 splicing, and 1 large tandem insertion) that altered full-length titin. Among subjects studied by means of next-generation sequencing, the frequency of TTN mutations was significantly higher among subjects with dilated cardiomyopathy (54 of 203 [27%]) than among subjects with hypertrophic cardiomyopathy (3 of 231 [1%], P=3×10(-16)) or controls (7 of 249 [3%], P=9×10(-14)). TTN mutations cosegregated with dilated cardiomyopathy in families (combined lod score, 11.1) with high (>95%) observed penetrance after the age of 40 years. Mutations associated with dilated cardiomyopathy were overrepresented in the titin A-band but were absent from the Z-disk and M-band regions of titin (P≤0.01 for all comparisons). Overall, the rates of cardiac outcomes were similar in subjects with and those without TTN mutations, but adverse events occurred earlier in male mutation carriers than in female carriers (P=4×10(-5)). CONCLUSIONS: TTN truncating mutations are a common cause of dilated cardiomyopathy, occurring in approximately 25% of familial cases of idiopathic dilated cardiomyopathy and in 18% of sporadic cases. Incorporation of sequencing approaches that detect TTN truncations into genetic testing for dilated cardiomyopathy should substantially increase test sensitivity, thereby allowing earlier diagnosis and therapeutic intervention for many patients with dilated cardiomyopathy. Defining the functional effects of TTN truncating mutations should improve our understanding of the pathophysiology of dilated cardiomyopathy. (Funded by the Howard Hughes Medical Institute and others.).
Assuntos
Cardiomiopatia Dilatada/genética , Proteínas Musculares/genética , Mutação , Proteínas Quinases/genética , Adulto , Cardiomiopatia Dilatada/patologia , Conectina , Feminino , Técnicas de Genotipagem , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Análise de Sequência de DNA/métodos , Deleção de SequênciaRESUMO
The purpose of this study was to evaluate gender differences regarding outcome after continuous-flow left ventricular assist device (cfLVAD) implantation. The study was a retrospective review of prospectively collected data. Included were 24 consecutive female cfLVAD recipients and 24 male recipients (62.5% HeartMate II, 37.5% HeartWare) who received their devices between July 2007 and May 2013. Subjects were matched using propensity score analysis based on age, diagnosis, body surface area, preoperative mechanical circulatory support, heart failure severity score (INTERMACS class), and comorbidities. Female patients were significantly sicker before operation. After propensity score matching, there were no statistically significant differences in demographics or clinical baseline characteristics between male and female LVAD recipients. Also, there was a trend towards a longer postoperative intensive care unit stay in the female group (median 9 days [interquartile range 5-17] versus 15 days [interquartile range 8-33]; P < 0.061) and higher postoperative bilirubin values (median 14 mmol/L [interquartile range 10-17] versus 21 mmol/L [interquartile range 13-30]). However, there were no significant differences between the two groups in terms of outcome (P < 0.569). The overall survival was comparable between the two groups (log rank P < 0.389). Half (50%) of female patients required inotropic support for more than 7 days compared with 21.7% in the male group (P < 0.048). Half (50%) of female recipients required short-term postoperative right ventricular assist device implantation compared with 16.7% in the male group (P < 0.014). In conclusion, cfLVAD implantation as a bridge to transplantation is associated with longer duration of inotropic support and higher requirement for postoperative mechanical right ventricular support in women with similar survival rates. Further studies are required to identify additional demographic and clinical factors that modulate outcomes and will enhance the ability to risk-stratify cfLVAD recipients.
Assuntos
Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Coração Auxiliar , Risco Ajustado/métodos , Listas de Espera , Adulto , Estudos de Coortes , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Prognóstico , Pontuação de Propensão , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores Sexuais , Estatísticas não Paramétricas , Taxa de Sobrevida , Fatores de Tempo , Resultado do TratamentoRESUMO
The Synergy Micro-pump is the smallest implantable left ventricular assist device (LVAD) and provides partial flow support up to 4.25 L/min. It was shown that early intervention with this device can provide substantial benefits to patients with severe heart failure not yet sick enough for a full-support LVAD. However, as it can be inserted via small incisions with no need for sternotomy or cardiopulmonary bypass, it might be beneficial for selected high-risk patients. The aim of this study was to evaluate the efficacy of the Synergy Micro-pump in patients in INTERMACS class 1-2. From February 2012 to August 2013, 13 patients with severe heart failure were supported with the Synergy Pocket Micro-pump. Patients were divided into two groups according to INTERMACS class: the high-risk group (INTERMACS class 1-2) and the low-risk group (INTERMACS class 3-4). There were seven patients in INTERMACS class 1-2 and six in INTERMACS class 3-4. Patient demographics, perioperative characteristics, and postoperative outcomes were compared. There were no statistically significant differences in patient demographics, and mean support time was 108 ± 114 days in the high-risk group and 238 ± 198 days in the low-risk group. Also, there were no significant differences in perioperative characteristics or in the rate of postoperative adverse events. The overall survival was comparable between the two groups (one late death in each group, log-rank P = 0.608). Two patients from the high-risk group were upgraded to a full-support LVAD (P = 0.462) after 65 ± 84.9 days of mean support. One patient from the high-risk group and two patients from the low-risk group were successfully transplanted (P = 0.559). The use of the Synergy Micro-pump in INTERMACS 1-2 patients is feasible and is associated with similar postoperative outcome as in patients in INTERMACS 3-4. Carefully selected patients with severe heart failure could benefit due to the small size of the pump; however, further studies and medium-term follow-up are required.
Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Adulto , Ponte Cardiopulmonar , Feminino , Seguimentos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Análise de SobrevidaRESUMO
Chronic heart failure is a progressive and eventually fatal illness. Although the disease cannot be cured and treatment is symptom oriented, most of the patients benefit from optimum medical treatment. Patients with rapid deterioration in chronic advanced heart failure refractory to medical treatment need inotropic support and may need intra-aortic balloon pump to maintain circulatory support, which of course cannot be prolonged beyond a certain limit. The outcome of heart transplant and long-term ventricular assist device (VAD) in such patients is poor. The short-term mechanical circulatory support (MCS) offered to such patients not only provides effective circulatory support and stabilizes them hemodynamically, but also halts the ensuing or reverts the established end-organ failure. As the name suggests, the short-term MCS offers support for the short term, usually less than a month. Although some patients with acute heart failure experience recovery of myocardial function with short-term MCS support, others become dependent. These patients, stabilized and "stuck" with short-term MCS, can be "rescued" with long-term VAD or heart transplantation. Both the procedures, when done in this special situation, have their inherent advantages, disadvantages, and complications and hence need the careful consideration about the choice of the procedure. We have tried to elucidate this situation by considering the advantages and disadvantages of both options.
Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Humanos , Resultado do TratamentoRESUMO
PURPOSE: To evaluate the diagnostic accuracy of cardiac computed tomographic (CT) angiography without the use of ß-blockers compared with that of invasive angiography for the detection of cardiac allograft vasculopathy (CAV) in heart transplant recipients. MATERIALS AND METHODS: The study was approved by the research ethics committee and informed consent was obtained. Heart transplant recipients (n = 138) scheduled for routine invasive angiography were prospectively enrolled to undergo CT to evaluate coronary artery calcification and retrospectively gated cardiac CT angiography with a 64-section scanner. The cardiac CT angiographic images were systematically analyzed for image quality. Degree of CAV was assessed by using a 15-coronary segments model. The area under the receiver operating characteristic curve, sensitivity, specificity, and negative and positive predictive values of cardiac CT angiography for detection of CAV with any degree of stenosis and greater than or equal to 50% stenosis were calculated. RESULTS: Coronary artery calcification was absent in 82 patients, five (6%) of whom had CAV with 50% or more stenosis. Interpretable image quality was obtained in 130 (96%) of the 136 patients who completed the study and 1900 (98%) of 1948 segments. At the patient level, cardiac CT angiography had an area under the receiver operating characteristic curve, sensitivity, specificity, and positive and negative predictive values of 0.880 (95% confidence interval: 0.819, 0.941), 98%, 78%, 77%, and 98%, respectively, for diagnosis of CAV with any degree of stenosis, but for CAV with 50% or more stenosis, the corresponding values were 0.942 (95% confidence interval: 0.885, 1.000), 96%, 93%, 72%, and 99%, respectively. None of the 61 patients with normal cardiac CT angiographic results had CAV on the basis of invasive angiographic images. CONCLUSION: The study results show that cardiac CT angiography compares favorably with invasive angiography in detecting CAV in heart transplant recipients and may be a preferable screening technique because of its noninvasive nature. The absence of coronary artery calcification alone is not reliable enough for excluding CAV.
Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Transplante de Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e EspecificidadeRESUMO
Myocarditis is a known extraintestinal manifestation of inflammatory bowel diseases, but it rarely leads to acute cardiac pump failure. We report a case of fulminant myocarditis associated with ulcerative colitis treated successfully with an extracorporeal membrane oxygenator.
Assuntos
Colite Ulcerativa/complicações , Colite Ulcerativa/terapia , Oxigenação por Membrana Extracorpórea/métodos , Miocardite/etiologia , Miocardite/terapia , Adulto , Colite Ulcerativa/diagnóstico , Diagnóstico Diferencial , Humanos , Masculino , Miocardite/diagnóstico , Resultado do TratamentoRESUMO
Variants of fibrinogen A alpha-chain (AFib) cause the most common type of hereditary renal amyloidosis in Europe and, possibly, the United States as well. Variant fibrinogen is produced in the liver, and solitary renal allografts fail within 1 to 7 years with recurrent amyloidosis. We assessed 22 AFib patients for combined liver and kidney transplantation (LKT) and report the clinical features and outcome. Twenty-one had E526V and 1, the R554L variant. Coronary atherosclerosis was identified in 68% and systemic atheromatosis in 55%. Vascular atheroma excised at endarterectomy and endomyocardial biopsies contained purely variant fibrinogen amyloid. Half had autonomic neuropathy. Six of 9 patients who underwent LKT are alive (67%), with good allograft function and no amyloidosis at median 67 months (range, 33-155 months) of follow-up. Serial technetium-99m-labeled dimercaptosuccinic acid ((99m)Tc-DMSA) renal scintigraphy in 2 cases of preemptive LKT demonstrated preserved native kidney residual function at 5 years. Four explanted livers were used successfully for domino transplantation. Fibrinogen amyloidosis is a systemic amyloid disease with visceral, vascular, cardiac, and neurologic involvement. LKT is curative; however, cardiovascular amyloidosis may preclude this option. Our data encourage evaluation of preemptive solitary liver transplantation early in the course of amyloid nephropathy to prevent hemodialysis and kidney transplantation.
Assuntos
Amiloidose Familiar/patologia , Fibrinogênio/genética , Transplante de Fígado , Adulto , Amiloidose Familiar/diagnóstico por imagem , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/patologia , Sistema Cardiovascular/patologia , Feminino , Humanos , Transplante de Rim/diagnóstico por imagem , Transplante de Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Mutação/genética , Doenças do Sistema Nervoso/complicações , Doenças do Sistema Nervoso/patologia , Seleção de Pacientes , Fenótipo , Cintilografia , Ácido Dimercaptossuccínico Tecnécio Tc 99m , Resultado do Tratamento , UltrassonografiaRESUMO
Transplant recipients require immunosuppression to prevent allograft rejection, placing them at risk of opportunistic infections including fungal infection. Difficulties in managing fungal infections include: establishing diagnosis, poor treatment response, drug interactions and toxicity. We report our single centre experience of treating fungal infections using systemic non-Amphotericin current generation antifungals. Patients receiving inpatient antifungal therapy from September 2005 to December 2010 were identified from pharmacy records. Fungal infections were retrospectively classified according to European Organization for Research and Treatment of Cancer (EORTC) criteria. Treatment outcomes were classified in a manner similar to those used in clinical trials. Two hundred and forty-nine recipients received antifungal treatment, 204 lungs and 45 hearts. One hundred and one patients received Voriconazole, 82 Caspofungin and 65 received both agents. One patient was unsuccessfully treated with additional Amphotericin. Treatment duration varied from 1.5 to 12 weeks. One hundred and sixty-five patients had a complete response, 24 had a partial response and in 60 patients treatment was unsuccessful. The response to systemic non-Amphotericin based antifungal therapy was high. We propose that diagnostic criteria without positive identification of a fungus allow treatment to be started early with few clinically relevant side effects.
Assuntos
Anfotericina B/uso terapêutico , Transplante de Coração/efeitos adversos , Transplante de Pulmão/efeitos adversos , Micoses/complicações , Adolescente , Adulto , Idoso , Anti-Infecciosos/farmacologia , Antifúngicos/farmacologia , Estudos de Coortes , Interações Medicamentosas , Feminino , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Micoses/prevenção & controle , Fatores de Tempo , Resultado do TratamentoRESUMO
Electrophysiological and pharmacological data from the human heart are limited due to the absence of simple but representative experimental model systems of human myocardium. The aim of this study was to establish and characterise adult human myocardial slices from small patients' heart biopsies as a simple, reproducible and relevant preparation suitable for the study of human cardiac tissue at the multicellular level. Vibratome-cut myocardial slices were prepared from left ventricular biopsies obtained from end-stage heart failure patients undergoing heart transplant or ventricular assist device implantation, and from hearts of normal dogs. Multiple slices were prepared from each biopsy. Regular contractility was observed at a range of stimulation frequencies (0.1-2 Hz), and stable electrical activity, monitored using multi-electrode arrays (MEA), was maintained for at least 8 h from slice preparation. ATP/ADP and phosphocreatine/creatine ratios were comparable to intact organ values, and morphology and gap junction distribution were representative of native myocardium. MEA recordings showed that field potential duration (FPD) and conduction velocity (CV) in human and dog slices were similar to the values previously reported for papillary muscles, ventricular wedges and whole hearts. Longitudinal CV was significantly faster than transversal CV, with an anisotropic ratio of 3:1 for human and 2.3:1 for dog slices. Importantly, slices responded to the application of E-4031, chromanol and 4-aminopyridine, three potassium channel blockers known to affect action potential duration, with an increase in FPD. We conclude that viable myocardial slices with preserved structural, biochemical and electrophysiological properties can be prepared from adult human and canine heart biopsies and offer a novel preparation suitable for the study of heart failure and drug screening.
Assuntos
Coração/efeitos dos fármacos , Coração/fisiologia , Adulto , Animais , Cães , Fenômenos Eletrofisiológicos/efeitos dos fármacos , Fenômenos Eletrofisiológicos/fisiologia , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiologia , Humanos , Técnicas In Vitro , Pessoa de Meia-Idade , Miocárdio/metabolismo , Miocárdio/patologia , Bloqueadores dos Canais de Potássio/farmacologia , Sobrevivência de Tecidos/fisiologiaRESUMO
BACKGROUND: In patients with severe heart failure, prolonged unloading of the myocardium with the use of a left ventricular assist device has been reported to lead to myocardial recovery in small numbers of patients for varying periods of time. Increasing the frequency and durability of myocardial recovery could reduce or postpone the need for subsequent heart transplantation. METHODS: We enrolled 15 patients with severe heart failure due to nonischemic cardiomyopathy and with no histologic evidence of active myocarditis. All had markedly reduced cardiac output and were receiving inotropes. The patients underwent implantation of left ventricular assist devices and were treated with lisinopril, carvedilol, spironolactone, and losartan to enhance reverse remodeling. Once regression of left ventricular enlargement had been achieved, the beta2-adrenergic-receptor agonist clenbuterol was administered to prevent myocardial atrophy. RESULTS: Eleven of the 15 patients had sufficient myocardial recovery to undergo explantation of the left ventricular assist device a mean (+/-SD) of 320+/-186 days after implantation of the device. One patient died of intractable arrhythmias 24 hours after explantation; another died of carcinoma of the lung 27 months after explantation. The cumulative rate of freedom from recurrent heart failure among the surviving patients was 100% and 88.9% 1 and 4 years after explantation, respectively. The quality of life as assessed by the Minnesota Living with Heart Failure Questionnaire score at 3 years was nearly normal. Fifty-nine months after explantation, the mean left ventricular ejection fraction was 64+/-12%, the mean left ventricular end-diastolic diameter was 59.4+/-12.1 mm, the mean left ventricular end-systolic diameter was 42.5+/-13.2 mm, and the mean maximal oxygen uptake with exercise was 26.3+/-6.0 ml per kilogram of body weight per minute. CONCLUSIONS: In this single-center study, we found that sustained reversal of severe heart failure secondary to nonischemic cardiomyopathy could be achieved in selected patients with the use of a left ventricular assist device and a specific pharmacologic regimen.
Assuntos
Agonistas Adrenérgicos beta/uso terapêutico , Cardiomiopatia Dilatada/tratamento farmacológico , Cardiomiopatia Dilatada/cirurgia , Fármacos Cardiovasculares/uso terapêutico , Coração Auxiliar , Adolescente , Agonistas de Receptores Adrenérgicos beta 2 , Adulto , Pressão Sanguínea , Débito Cardíaco , Cardiomiopatia Dilatada/mortalidade , Cardiomiopatia Dilatada/fisiopatologia , Clembuterol/uso terapêutico , Terapia Combinada , Feminino , Transplante de Coração , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Estudos Prospectivos , Falha de Prótese , Taxa de SobrevidaRESUMO
BACKGROUND: Chronic kidney disease is common after heart transplantation, and is related to ciclosporin (CsA) therapy. We compared the safety and efficacy of two ciclosporin withdrawal regimens. METHODS: CsA was stopped and sirolimus (SRL) commenced immediately and the transfer was covered with prednisolone. Those on azathioprine (AZA) were transferred to MMF. In protocol A, the SRL target concentration was 16 (12-20) ng/ml; in protocol B, the target concentration was 7(5-10) ng/ml, but mycophenolate (MMF) and steroids were commenced prior to the transfer. RESULTS: Baseline characteristics were similar in both groups except that group B were switched later after transplantation. Renal function improved significantly in both groups; this was maintained up to 1 year. Two patients in group A experienced acute rejection (ISHLT grade 3A or 2R); none was seen in group B. Six patients (46%) remained on protocol A and 22 (85%) remained on protocol B at 1 year. CONCLUSIONS: MMF-SRL substitution resulted in a rapid but partial improvement in renal function; the lower dose SRL regimen was better tolerated.
Assuntos
Ciclosporina/administração & dosagem , Transplante de Coração , Imunossupressores/uso terapêutico , Nefropatias/tratamento farmacológico , Ácido Micofenólico/análogos & derivados , Complicações Pós-Operatórias/tratamento farmacológico , Sirolimo/uso terapêutico , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ácido Micofenólico/uso terapêutico , Estudos RetrospectivosRESUMO
BACKGROUND: Chronic kidney disease (CKD) is a complication of heart transplantation related to calcineurin inhibitor nephrotoxicity. However, it is unclear whether early ciclosporin (CsA) exposure influences CKD in the long term. METHODS: We analysed risk factors for CKD in 352 patients who underwent orthotopic heart transplantation (1995-2005). In 2000, we reduced our target CsA levels in the first year after transplantation. RESULTS: Actuarial patient survival was 79% at 1 year and 62% at 10 years. Estimated median glomerular filtration rate (eGFR) by the four-variable Modification of Diet in Renal Disease formula was 64 ml/min/1.73 m2 before transplantation, inter-quartile range (IQR) 54-78. After transplantation, the eGFR was 48 (IQR 37-61) at Year 1, and 41(35-57) at Year 10. The cumulative probability of eGFR <45 ml/min/1.73 m2 was 45% at Year 1, 71% at Year 5 and 83% at Year 10. A multivariable logistic regression model was constructed for the development of eGFR <45 ml/min/1.73 m2 by 3 years. The risk factors were post-operative renal replacement therapy for acute renal failure (ARF), P < 0.001; pretransplant diabetes, P = 0.005; increasing recipient age, P < 0.001; female recipient, P = 0.029; female donor, P = 0.04, but not CsA regimen. The cumulative probability of developing stage 5 CKD (eGFR <15) was 3% at Year 5 and 12% at Year 10. Although lower ciclosporin initial levels were associated with less renal dysfunction at Year 1 (P = 0.008), there was no significant effect by Year 3 (P = 0.7). CONCLUSION: The incidence of CKD increased with time and was not influenced by the CsA regimen. Some risk factors are not modifiable but measures to reduce the incidence of post-operative ARF may help to reduce CKD.
Assuntos
Ciclosporina/efeitos adversos , Transplante de Coração/efeitos adversos , Imunossupressores/efeitos adversos , Nefropatias/epidemiologia , Adolescente , Adulto , Idoso , Doença Crônica , Ciclosporina/uso terapêutico , Relação Dose-Resposta a Droga , Feminino , Rejeição de Enxerto/imunologia , Rejeição de Enxerto/prevenção & controle , Transplante de Coração/imunologia , Humanos , Imunossupressores/uso terapêutico , Falência Renal Crônica/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Adulto JovemRESUMO
OBJECTIVES: Treatments for end-stage heart failure include medical therapy, heart transplantation, and, more recently, implantation of a ventricular support assist device (VAD). Little is known about the psychological adjustment and quality of life of these patients and how patients with a VAD in situ compare with those who underwent transplantation or had the device explanted. DESIGN AND METHODS: A cross-sectional study using grounded theory methodology was carried out. Patients with heart failure living with a VAD and those who underwent transplantation or explantation were interviewed to elicit perceptions of their adjustment and quality of life. RESULTS: All patients identified perceived control as their core category, with 3 related conceptual categories: normality, uncertainty, and emotional state. Identity of illness/VAD and the impact of the device were specifically identified by VAD patients, and independence was identified by transplant patients. CONCLUSION: This study has identified previously unrecognized concepts in the adjustment of patients with either a VAD in situ or who have had the device explanted or have undergone transplantation. It provides a basis for the development of specific nursing and psychological care designed to support this developing surgical practice.
Assuntos
Adaptação Psicológica , Atitude Frente a Saúde , Insuficiência Cardíaca/psicologia , Coração Auxiliar/psicologia , Atividades Cotidianas/psicologia , Adolescente , Adulto , Estudos Transversais , Medo , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Controle Interno-Externo , Masculino , Pessoa de Meia-Idade , Modelos Psicológicos , Avaliação das Necessidades , Pesquisa Metodológica em Enfermagem , Pesquisa Qualitativa , Qualidade de Vida/psicologia , Papel do Doente , Inquéritos e Questionários , Incerteza , Listas de Espera , Adulto JovemRESUMO
Aims: The need for right ventricular assist device (RVAD) support after left ventricular assist device (LVAD) therapy is associated with increased morbidity and mortality. We used 2D echocardiographic strain analysis to assess right atrial (RA) and right ventricular (RV) mechanics and predict the need for RV mechanical support after LVAD implantation. Methods and results: Seventy advanced chronic heart failure (ACHF) patients [59 male, age 47 ± 12 years, 79% dilated cardiomyopathy, left ventricular ejection fraction 23 ± 10%] received continuous-flow LVAD as a bridge to transplantation over an 18 month period. A retrospective analysis of RV and RA strain and right heart dyssynchrony was performed comparing those requiring RVAD (20%, n = 14) with those who did not (non-RVAD 80%, n = 56). One-year survival was significantly lower in the RVAD group (50% vs. 79%; P < 0.03). Independent predictors of RVAD support were: low peak RA longitudinal strain (RALS) [odds ratio (OR) 2.5, 95% confidence interval (95% CI) 1.37-2.0; P = 0.03], low RV free-wall longitudinal strain (RVFWLS) (OR 1.3, 95% CI 1.03-2.3; P = 0.04), and degree of intra-RV dyssynchrony (DRVFW-IVS, OR 1.3, 95% CI 1.02-1.3; P = 0.04). Conclusion: In LVAD recipients needing RVAD support, there was lower RALS and RVFWLS in addition to greater RV free-wall mechanical delay. We conclude that RA and RV strain and dyssynchrony analysis have the potential to add incremental value to the pre-VAD-implantation assessment made using conventional echo measurements.
Assuntos
Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Disfunção Ventricular Direita/diagnóstico por imagem , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Disfunção Ventricular Direita/fisiopatologiaRESUMO
BACKGROUND: Heart transplantation (HTx) remains the most effective long-term treatment for advanced heart failure. Primary graft dysfunction (PGD) continues to be a potentially life-threatening early complication. In 2014, a consensus statement released by International Society for Heart and Lung Transplantation (ISHLT) established diagnostic criteria for PGD. We studied the incidence of PGD across the United Kingdom. METHODS: We analyzed the medical records of all adult patients who underwent HTx between October 2012 and October 2015 in the 6 UK heart transplant centers Preoperative donor and recipient characteristics, intraoperative details, and posttransplant complications were compared between the PGD and non-PGD groups using the ISHLT definition. Multivariable analysis was performed using logistic regression. RESULTS: The incidence of ISHLT PGD was 36%. Thirty-day all-cause mortality in those with and without PGD was 31 (19%) versus 13 (4.5%) (P = 0.0001). Donor, recipient, and operative factors associated with PGD were recipient diabetes mellitus (P = 0.031), recipient preoperative bilateral ventricular assist device (P < 0.001), and preoperative extracorporeal membranous oxygenation (P = 0.023), female donor to male recipient sex mismatch (P = 0.007), older donor age (P = 0.010), and intracerebral haemorrhage/thrombosis in donor (P = 0.023). Intraoperatively, implant time (P = 0.017) and bypass time (P < 0.001) were significantly longer in the PGD cohort. Perioperatively, patients with PGD received more blood products (P < 0.001). Risk factors identified by multivariable logistic regression were donor age (P = 0.014), implant time (P = 0.038), female: male mismatch (P = 0.033), recipient diabetes (P = 0.051) and preoperative ventricular assist device/extracorporeal membranous oxygenation support (P = 0.012). CONCLUSIONS: This is the first national study to examine the incidence and significance of PGD after HTx using the ISHLT definition. PGD remains a frequent early complication of HTx and is associated with increased mortality.
Assuntos
Transplante de Coração/efeitos adversos , Disfunção Primária do Enxerto/epidemiologia , Adulto , Transfusão de Sangue , Feminino , Transplante de Coração-Pulmão , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Disfunção Primária do Enxerto/etiologia , Disfunção Primária do Enxerto/mortalidade , Disfunção Primária do Enxerto/terapia , Estudos Retrospectivos , Fatores de Risco , Reino UnidoRESUMO
OBJECTIVES: Left ventricular assist devices are funded in the UK exclusively as a bridge to transplant (BTT). However, patients who potentially could receive a transplant may develop reversible contraindications to transplant. Bridge to candidacy (BTC) has sometimes been controversial, given the uncertain clinical efficacy of BTC and the risk that reimbursement could be denied. We analysed the UK ventricular assist device database to understand how common BTC was and to assess patient survival rates and incidences of transplants. METHODS: We identified BTC implants in patients with pulmonary hypertension, chronic kidney disease and obesity using the UK guidelines for heart transplants. RESULTS: A total of 306 of 540 patients had complete data and 157 were identified as BTC (51%). Overall, there was no difference in survival rates between patients designated as BTC and those designated at BTT (71.9 vs 72.9% at 1 year, respectively; P = 0.82). However, the survival rate was lower at all time points in those with an estimated glomerular filtration rate (eGFR) <40 and in patients with a body mass index (BMI) >32 up to 1-year postimplant. There were no significant differences in the incidence of transplant between patients who were BTC and BTT or for any subgroup up to 5 years. However, we noted a diverging trend towards a lower cumulative incidence of transplant for patients with a BMI >32. CONCLUSIONS: BTC is common in the UK and appears clinically effective, given that the survival rates and the incidence of transplants were comparable with those for BTT. Patients with a high BMI have a worse survival rate through to 1 year and a trend for a lower incidence of a transplant. Patients with a low eGFR also have a worse survival rate, but a similar proportion received transplants.
Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Transplantados , Adulto , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida/tendências , Resultado do Tratamento , Reino Unido/epidemiologiaRESUMO
BACKGROUND: Surveillance endomyocardial biopsies (EMBs) are used for the early diagnosis of acute cardiac allograft rejection. Protocols became standardized in an earlier era and their utility with contemporary immunosuppression has not been investigated. METHODS: We studied 258 patients after orthotopic heart transplantation comparing 135 patients immunosuppressed by mycophenolate mofetil (MMF) with 123 patients treated by azathioprine (AZA); both with cyclosporine and corticosteroids after induction therapy with rabbit antithymocyte globulin. Fifteen EMBs were scheduled in the first year. Additional EMBs were performed for suspected rejection, after treatment, or for inadequate samples. The MMF group had 1875 EMBs vs. 1854 in the AZA group. RESULTS: The yield of International Society for Heart and Lung Transplantation (ISHLT) grade> or =3A biopsy-proven acute rejection (BPAR) was 1.87% per biopsy (35 of 1875) with MMF vs. 3.13% (58 of 1854) with AZA P=0.024. The number of clinically silent BPAR ISHLT grade > or =3A (the true yield of surveillance EMBs) was 1.39% (26 of 1875) of biopsies MMF vs. 2.1% (39 of 1854) AZA, P=0.48. There were five serious complications requiring intervention or causing long-term sequelae; 0.13% (5 of 3729) per biopsy and 1.94% (5 of 258) per patient. The incidence of all definite and potential complications was 1.42% (53 of 3729) per biopsy and 20.5% (53 of 258) per patient. There was no biopsy-related mortality. CONCLUSION: The yield of BPAR was low in the AZA group and very low in the MMF group. The incidence of complications was also low, but repeated biopsies led to a higher rate per patient. Routine surveillance EMBs and the frequency of such biopsies should be reevaluated in the light of their low yield with current immunosuppression.