Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Extra Corpor Technol ; 53(1): 57-61, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33814607

RESUMO

Heparin anticoagulation monitoring by point-of-care activated clotting time (ACT) is essential for cardiopulmonary bypass (CPB) initiation, maintenance, and anticoagulant reversal. Concerns exist regarding the comparability of kaolin activated ACT devices. The current study, therefore, evaluated the agreement of ACT assays using parallel measurements performed on two commonly used devices. Measurements were conducted in a split-sample fashion on both the ACT Plus (Medtronic, Minneapolis, MN) and i-STAT (Abbott Point of Care, Princeton, NJ) analyzers. Blood samples from 100 adult patients undergoing elective cardiac surgery with CPB were assayed at specified time points: before heparinization, following systemic heparinization, after CPB initiation, every 30 minutes during CPB, and following protamine administration. A cutoff value of 400 seconds (s) was used as part of the local protocol. Measurements were compared using t tests or Wilcoxon signed-rank tests, linear regression, and Bland-Altman analyses. Parallel ACT measurements demonstrated a good linear correlation (r = .831, p < .001). The overall median difference between both measurements was significantly different from zero, amounting to 87 (14-189) (p < .001), with limits of agreement of -124 and 333s. The i-STAT-derived ACT values were systematically lower than the ACT Plus values, which was more pronounced during CPB. Fourteen patients received additional heparin during CPB at a median ACT Plus value of 414s, with a concomitant median i-STAT value of 316s. Assuming 308s as the theoretical i-STAT cutoff value based on the linear regression equation and an ACT Plus threshold of 400s, 29 patients would have received additional heparin. Based on these results, kaolin point-of-care ACT devices cannot be used interchangeably. Device-specific predefined target values are warranted to avert heparin overdosing during CPB.


Assuntos
Caulim , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Anticoagulantes , Testes de Coagulação Sanguínea , Ponte Cardiopulmonar , Heparina , Humanos , Tempo de Coagulação do Sangue Total
2.
J Extra Corpor Technol ; 49(3): 182-191, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28979042

RESUMO

Postoperative neurological complications (PNCs) following cardiac surgery with cardiopulmonary bypass (CPB) is a detrimental complication, contributing to increased mortality rates and health care costs. To prevent intraoperative cerebral desaturations associated with PNC, continuous brain monitoring using near-infrared spectroscopy has been advocated. However, clear evidence for a defined desaturation threshold requiring intervention during CPB is still lacking. Since cerebral oximetry readings are nonspecific, cerebral tissue oxygenation values need to be interpreted with caution and in the context of all available clinical information. Therefore, maintaining an intact autoregulatory activity during CPB rather than solely focusing on regional cerebral oxygen saturation measurements will collectively contribute to optimization of patient care during CPB.


Assuntos
Química Encefálica/fisiologia , Ponte Cardiopulmonar , Oxigênio/metabolismo , Circulação Cerebrovascular/fisiologia , Homeostase/fisiologia , Humanos , Monitorização Intraoperatória/métodos , Oximetria , Oxigênio/análise , Complicações Pós-Operatórias/etiologia
3.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-35947693

RESUMO

OBJECTIVES: Thoracoscopic ablation for atrial fibrillation (AF) and minimally invasive direct coronary artery bypass (MIDCAB) with robot-assisted left internal mammary artery (LIMA) harvesting may represent a safe and effective alternative to more invasive surgical approaches via sternotomy. The aim of our study was to describe the feasibility, safety and efficacy of a unilateral left-sided thoracoscopic AF ablation and concomitant MIDCAB surgery. METHODS: Retrospective analysis of a prospectively gathered cohort was performed of all consecutive patients with AF and at least a critical left anterior descending artery (LAD) stenosis that underwent unilateral left-sided thoracoscopic AF ablation and concomitant off-pump MIDCAB surgery in the Maastricht University Medical Centre between 2017 and 2021. RESULTS: Twenty-three patients were included [age 69 years (standard deviation = 8), paroxysmal AF 61%, left atrial volume index 42 ml/m2 (standard deviation = 11)]. Unilateral left-sided thoracoscopic isolation of the left (n = 23) and right (n = 22) pulmonary veins and box (n = 21) by radiofrequency ablation was succeeded by epicardial validation of exit- and entrance block (n = 22). All patients received robot-assisted LIMA harvesting and off-pump LIMA-LAD anastomosis through a left mini-thoracotomy. The perioperative complications consisted of one bleeding of the thoracotomy wound and one aborted myocardial infarction not requiring intervention. The mean duration of hospital stay was 6 days (standard deviation = 2). After discharge, cardiac hospital readmission occurred in 4 patients (AF n = 1; pleural- and pericardial effusion n = 2, myocardial infarction requiring the percutaneous intervention of the LIMA-LAD n = 1) within 1 year. After 12 months, 17/21 (81%) patients were in sinus rhythm when allowing anti-arrhythmic drugs. Finally, the left atrial ejection fraction improved postoperatively [26% (standard deviation = 11) to 38% (standard deviation = 7), P = 0.01]. CONCLUSIONS: In this initial feasibility and early safety study, unilateral left-sided thoracoscopic AF ablation and concomitant MIDCAB for LIMA-LAD grafting is a feasible, safe and efficacious for patients with AF and a critical LAD stenosis.


Assuntos
Fibrilação Atrial , Estenose Coronária , Infarto do Miocárdio , Idoso , Antiarrítmicos , Artérias , Fibrilação Atrial/cirurgia , Constrição Patológica , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Retrospectivos , Resultado do Tratamento
4.
Ultrasound Med Biol ; 33(3): 371-8, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17208354

RESUMO

The blood pressure waveform carries information about the cardiac contraction and the impedance characteristics of the vascular bed. Here, we demonstrate that the start of isovolumic ventricular contraction is persistently reflected as an inflection point in the pressure wave as recorded in the aortic root (TP(IC)) as well as in the carotid artery distension waveform (TD(IC)) as it travels down the arterial tree. In a group of six patients with normal pressure gradients across the aortic valve after valve replacement, the TP(IC) had a small delay with respect to the onset of isovolumic ventricular contraction (<10 ms). In a group (n = 21) of young presumably healthy volunteers, the inflection point occurred persistently in the carotid distension waveform, as recorded by means of ultrasound, before the systolic foot (intersubject delay between inflection point and systolic foot: mean +/- SD = 40.0 +/- 9.4 ms, intrasubject SD 4.6 ms). Retrograde coronary blood flow during isovolumic ventricular contraction may be the origin of the persistent end-diastolic pressure and distension perturbation. This study shows that the duration of the isovolumic contraction can be reliably extracted from the carotid artery distension waveform.


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Contração Miocárdica/fisiologia , Adulto , Idoso , Aorta/fisiologia , Valva Aórtica/fisiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Artéria Carótida Primitiva/fisiologia , Circulação Coronária/fisiologia , Ecocardiografia/métodos , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia , Sístole/fisiologia , Vasodilatação/fisiologia , Função Ventricular , Função Ventricular Esquerda/fisiologia
5.
J Heart Valve Dis ; 12(3): 325-32, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12803332

RESUMO

BACKGROUND AND AIM OF THE STUDY: Preoperative left ventricular (LV) function is the strongest predictor of outcome after valve replacement for aortic stenosis (AS). Although pressure-volume analysis with the conductance catheter technique can provide detailed information on LV systolic and diastolic function, this technique has not yet been used in AS patients. The present study examined the potential use of LV function measurements using pressure-volume analysis with a conductance catheter during surgery for AS. METHODS: In six patients with severe symptomatic AS, a conductance catheter was placed under transesophageal echocardiographic guidance in the left ventricle via the right superior pulmonary vein. RESULTS: The procedure was successful in all patients and lengthened the duration of surgery by <30 min, but with no increase in bypass or aortic cross-clamp times. Pressure-volume analysis showed that systolic function was normal in all patients (ejection fraction 42-59%, end-systolic elastance 1.6-4.5 mmHg/ml), while diastolic dysfunction was found in all patients (Tau 32-96 ms, LV end-diastolic pressure 7-42 mmHg, atrial kick 25-60%). After valve replacement, systolic function improved, but diastolic function did not. CONCLUSION: The conductance catheter placed via the pulmonary vein can determine LV systolic and diastolic dysfunction in detail in an individual patient with AS before and after valve replacement. The technique may be used to extend diagnostic data from less-invasive modalities and to determine prognosis in the individual patient.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Idoso , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/métodos , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/métodos , Prognóstico , Estudos Prospectivos , Medição de Risco , Estudos de Amostragem , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Resultado do Tratamento
6.
Interact Cardiovasc Thorac Surg ; 19(2): 232-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24729199

RESUMO

OBJECTIVES: We aimed to investigate the association of patient characteristics and allogeneic blood transfusion products in development of post-cardiac surgery nosocomial infections. METHODS: This retrospective study was conducted in 7888 patients undergoing cardiac surgery with median sternotomy and cardiopulmonary bypass. Multivariable logistic regression analysis was used for independent effect of variables on infections. RESULTS: A total of 970 (12.3%) patients developed one or several types of postoperative infections. Urinary (n = 351, 4.4%) and pulmonary tract infections (n = 478, 6.1%) occurred more frequently than sternal wound infections (superficial: n = 102, 1.3%, deep: n = 72, 0.9%) and donor site infections (n = 61, 0.8%). Interventions, including valve replacement (P = 0.002) and coronary artery bypass grafting combined with valve replacement (P = 0.012), were associated with increased risk of several types of postoperative infections. Patients' profiles changed substantially over the years; morbid obesity (P = 0.019), smoking (P = 0.001) and diabetes mellitus (P = 0.001) occur more frequently nowadays. Furthermore, surgical site infections showed to be related to morbid obesity (P < 0.001) and higher risk stratification (P = 0.031). Smoking (P < 0.001) and chronic obstructive pulmonary disease (P < 0.001) were related to pulmonary tract infections. In addition, diabetic patients developed more sepsis (P = 0.003) and advanced age was associated with development of urinary tract infections (P < 0.001). Even after correcting for other factors, blood transfusion was associated with all types of postoperative infection (P < 0.001). This effect remained present in both leucocyte-depleted and non-leucocyte-depleted transfusion. CONCLUSIONS: Our data showed that post-cardiac surgery infections occur more frequently in patients with predetermined risk factors. The amount of blood transfusions was integrally related to every type of postoperative infection.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Infecção Hospitalar/epidemiologia , Transfusão de Eritrócitos/efeitos adversos , Infecções Respiratórias/epidemiologia , Infecção da Ferida Cirúrgica/epidemiologia , Infecções Urinárias/epidemiologia , Fatores Etários , Ponte Cardiopulmonar/efeitos adversos , Distribuição de Qui-Quadrado , Comorbidade , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/microbiologia , Infecção Hospitalar/mortalidade , Feminino , Humanos , Incidência , Modelos Logísticos , Masculino , Análise Multivariada , Países Baixos , Razão de Chances , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/microbiologia , Infecções Respiratórias/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fumar/efeitos adversos , Esternotomia/efeitos adversos , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/microbiologia , Infecção da Ferida Cirúrgica/mortalidade , Fatores de Tempo , Resultado do Tratamento , Infecções Urinárias/diagnóstico , Infecções Urinárias/microbiologia , Infecções Urinárias/mortalidade
7.
Am J Physiol Heart Circ Physiol ; 288(4): H1874-84, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15604131

RESUMO

In patients with aortic stenosis, the left ventricular afterload is determined by the degree of valvular obstruction and the systemic arterial system. We developed an explicit mathematical model formulated with a limited number of independent parameters that describes the interaction among the left ventricle, an aortic stenosis, and the arterial system. This ventricular-valvular-vascular (V(3)) model consists of the combination of the time-varying elastance model for the left ventricle, the instantaneous transvalvular pressure-flow relationship for the aortic valve, and the three-element windkessel representation of the vascular system. The objective of this study was to validate the V(3) model by using pressure-volume loop data obtained in six patients with severe aortic stenosis before and after aortic valve replacement. There was very good agreement between the estimated and the measured left ventricular and aortic pressure waveforms. The total relative error between estimated and measured pressures was on average (standard deviation) 7.5% (SD 2.3) and the equation of the corresponding regression line was y = 0.99x - 2.36 with a coefficient of determination r(2) = 0.98. There was also very good agreement between estimated and measured stroke volumes (y = 1.03x + 2.2, r(2) = 0.96, SEE = 2.8 ml). Hence, this mathematical V(3) model can be used to describe the hemodynamic interaction among the left ventricle, the aortic valve, and the systemic arterial system.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Modelos Cardiovasculares , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Volume Cardíaco/fisiologia , Elasticidade , Próteses Valvulares Cardíacas , Humanos , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA