Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
2.
Cancer Biother Radiopharm ; 30(5): 200-10, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25860616

RESUMO

PURPOSE: We evaluated the possibility to assess (90)Y-PET/CT imaging quantification for dosimetry in (90)Y-peptide receptor radionuclide therapy. METHODS: Tests were performed by Discovery 710 Elite (GE) PET/CT equipment. A body-phantom containing radioactive-coplanar-spheres was filled with (90)Y water solution to reproduce different signal-to-background-activity-ratios (S/N). We studied minimum detectable activity (MDA) concentration, contrast-to-noise ratio (CNR), and full-width-at-half-maximum (FWHM). Subsequently, three recovery coefficients (RC)-based correction approaches were evaluated: maximum-RC, resolution-RC, and isovolume-RC. The analysis of the volume segmentation thresholding method was also assessed to derive a relationship between the true volume of the targets and the threshold to be applied to the PET images. (90)Y-PET/CT imaging quantification was then achieved on some patients and related with preclinical tests. Moreover, the dosimetric evaluation was obtained on the target regions. RESULTS: CNR value was greater than 5 if the MDA was greater than 0.2 MBq/mL with no background activity and 0.5-0.7 MBq/mL with S/N ranging from 3 to 6. FWHM was equal to 7 mm. An exponential fitting of isovolume RCs-based correction technique was adopted for activity quantification. Adaptive segmentation thresholding exponential curves were obtained and applied for target volume identification in three signal-to-background-activity-ratios. The imaging quantification study and dosimetric evaluations in clinical cases was feasible and the results were coherent with those obtained in preclinical tests. CONCLUSIONS: (90)Y-PET/CT imaging quantification is possible both in phantoms and in patients. Absorbed dose evaluations in clinical applications are strongly related to targets activity concentration.


Assuntos
Rim/efeitos da radiação , Neoplasias Hepáticas/radioterapia , Tumores Neuroendócrinos/radioterapia , Neoplasias Pancreáticas/radioterapia , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/farmacocinética , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Radioisótopos de Ítrio/farmacocinética , Idoso , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Imagens de Fantasmas , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Receptores de Somatostatina , Razão Sinal-Ruído , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA