Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am Heart J ; 265: 137-142, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37516263

RESUMO

BACKGROUND: It has been suggested that the disparity of outcomes between the studies of transcutaneous edge-to-edge repair (TEER) for functional mitral regurgitation (FMR) in heart failure with reduced ejection fraction (HFrEF) could be due to systematic differences in the populations studied. One proposal is that there are 2 broad groups: those with proportional FMR who respond less favorably, and those in whom the FMR is greater than expected (disproportionate) FMR where edge-to-edge TEER seems to be more effective. Whether this grouping is relevant for other percutaneous interventions for FMR is unknown. OBJECTIVES: We sought to compare clinical and echocardiographic outcomes of patients with HFrEF and proportionate and disproportionate FMR treated with indirect annuloplasty using the Carillon device. METHODS: This is a pooled analysis from 3 trials of patients with FMR. Key patient eligibility in these trials specified persistent grade 2+ to 4+ FMR with >5.5 cm left ventricular (LV) end-diastolic diameter (LVEDD) and reduced ejection fraction. Patients with an effective regurgitant orifice area/LV end-diastolic volume (EROA/LVEDV) ratio under 0.15 were assigned to the proportionate FMR group (n = 74;65%) and those with a ratio above 0.15 were classed as having disproportionate FMR (n = 39;35%). RESULTS: At 12 months following treatment, both groups showed improvements in all MR variables including regurgitation volume, EROA and vena contracta. Moreover, in patients with proportionate MR there were clinically relevant and statistically significant improvements in LV volumes and diameters. There was no independent relationship between the degree of proportionality as a continuous variable and the remodeling response to Carillon therapy (change in LVEDV r = 0.17; change in LVESV r = 0.14). CONCLUSION: Percutaneous mitral annuloplasty with the Carillon device reduces MR in patients with both proportionate and disproportionate FMR, and also results in LV reverse remodeling in those with proportionate FMR. The effect on remodeling remains to be verified in a large-scale trial.

2.
J Electrocardiol ; 67: 39-44, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34022470

RESUMO

BACKGROUND: Diagnostic criteria for anterior STEMI differ between the European Society of Cardiology (ESC) and the European Resuscitation Council (ERC). A greater degree of ST-segment elevation is required to meet ERC criteria compared to ESC criteria. This may potentially lead to discrepancies in management between emergency teams and cardiologists, subsequent delay in reperfusion therapy and worse prognosis. METHODS: We performed an observational study in patients with anterior STEMI routinely treated with primary PCI and assessed whether differing electrocardiographic diagnostic criteria could impact treatment and short-term prognosis. All patients in the study had anterior STEMI confirmed by electrocardiographic ESC criteria and subsequent coronary angiography. Patients were divided into two groups. Those who did not meet ERC criteria in the index ECG were assigned to the "non-ERC" group and were compared with those who met them - the "ERC" group. RESULTS: Out of 60 patients with anterior STEMI based on ESC criteria (mean age 66.9 ± 13.6 years, 70% males), 26 patients (44%) did not meet ERC criteria ("non-ERC" group) for STEMI. There were no significant differences in age, gender distribution or clinical characteristics between "ERC" and "non-ERC" patients. Total-Ischemic-Time, Patient-Delay, and System-Delay times were significantly longer in "non-ERC" group (433.1 ± 389.9 min vs. 264.2 ± 229.6 min, p = 0.03; 290.8 ± 337.6 min vs. 129.5 ± 144.9 min; p < 0.05 and 158.8 ± 158 vs 134.6 ± 191 min, p < 0.02 respectively). There were no differences in In-Hospital-Delay, procedure duration, and success rate of PCI. Proximal LAD occlusion (64.7%) and TIMI = 0 flow (73.5%) tended to be more frequently observed in "ERC" than in the "non-ERC" group (53.8% and 65.4%, respectively). Hospitalization time and LVEF (44.4 ± 8.7 vs 42.8 ± 9.5%, p = 0.53) were similar between groups. CONCLUSIONS: Differences in electrocardiographic criteria for anterior STEMI leave a significant proportion of patients undiagnosed. Patients with STEMI who failed to meet less strict ERC criteria had more distal LAD disease with better TIMI flow but received reperfusion therapy later. Thus, character of the disease may compensate for treatment delay but this needs to be further evaluated. Finally, lowering the cut-off point with stricter criteria compromises specificity and is expected to increase the false positive rate, however there were no false positives in this study as all patients were angiographically confirmed to have acute coronary obstruction.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Tempo para o Tratamento , Resultado do Tratamento
3.
Ann Noninvasive Electrocardiol ; 25(4): e12733, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31863721

RESUMO

BACKGROUND: Due to limited data, implantable loop recorders (ILR) are not currently recommended by the guidelines to routinely monitor patients after atrial fibrillation (AF) ablation. AIMS: To validate the diagnostic value of ILR after AF ablation, modern generation ILRs (LINQ) were implanted in patients scheduled for cryoballoon ablation of AF (CBA). METHODS: We included 29 patients with frequent and symptomatic episodes of paroxysmal AF. ILR was implanted 3 months prior to CBA, and data were collected before and for 6 months after the procedure. The device was programmed to maximize sensitivity of AF/ atrial tachycardia (AT) detection. All EGM recordings were "manually" assessed and annotated as true AF, pseudo AF, unrecognized AF, and episodes with no EGM available. Duration and episode-based standard performance metrics were evaluated. RESULTS: A total number of 5,842 episodes were recorded. A total of 4,403 episodes were true AF, 453 episodes were pseudo AF, and 986 episodes had no EGM available. The device did not recognize 144 episodes of AF. Duration-based sensitivity was 95.2%, duration-based specificity 99.9%, duration-based PPV 99.2%, duration-based NPV 99.9%, episode-based sensitivity 98.0%, and episode-based PPV 91.0%. Misdiagnosis happened in 1 in 10 episodes. Total data review time was 166 hr. CONCLUSIONS: Implantable loop recorders is a valuable tool in evaluation of AF episodes in patients undergoing CBA. However, for high precision all recorded episodes need to be evaluated "manually." The memory storage space is too low for frequent AF episodes, resulting in overwriting of stored EGMs and data loss.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Complicações Pós-Operatórias/diagnóstico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Próteses e Implantes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Catheter Cardiovasc Interv ; 94(2): 223-226, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31002207

RESUMO

Coronary artery perforation (CAP) is a rare but potentially life-threatening complication of percutaneous coronary intervention (PCI) that requires prompt diagnosis and effective treatment. Importantly, dynamic advances in interventional cardiology reflected by the increasing percentage of more challenging PCIs performed in more complex lesions have resulted in significant changes in CAPs pattern. Herein, we describe a technique and present a case report of CAP that occurred during percutaneous recanalization of the occluded restenotic right coronary artery (RCA) successfully treated with transcatheter embolization using gelatin sponge particles prepared on-site. The patient underwent coronary angiography with a subsequent attempt to open chronically occluded RCA. During the procedure, a guidewire was inadvertently positioned outside the arterial bed resulting in type III CAP. After unsuccessful prolonged balloon inflations as well as an anticoagulation reversal, embolization of the RCA with gelatin sponge particles as an ultima ratio treatment was performed. Sponge particles were prepared on-site by the operator, by cutting gelatin sponge used for wound healing. The procedure resulted in a total occlusion of the RCA and significant clinical improvement. The patient did not require pericardiocentesis and was discharged from the hospital after 10 days of an uneventful postprocedural course. The described technique is an easy and effective method of guidewire-related CAPs treatment in whom stent grafts cannot be implanted. Noteworthy, the technique can be applied in most cath labs as it utilizes a widely available gelatin sponge and does not require any specific expertise.


Assuntos
Cateterismo Cardíaco , Tamponamento Cardíaco/terapia , Vasos Coronários/lesões , Embolização Terapêutica , Esponja de Gelatina Absorvível/uso terapêutico , Traumatismos Cardíacos/terapia , Doença Iatrogênica , Intervenção Coronária Percutânea/efeitos adversos , Derrame Pericárdico/terapia , Idoso de 80 Anos ou mais , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/etiologia , Vasos Coronários/diagnóstico por imagem , Emergências , Feminino , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Humanos , Tamanho da Partícula , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/etiologia , Resultado do Tratamento
5.
J Interv Cardiol ; 29(6): 632-638, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27813186

RESUMO

OBJECTIVES: The purpose of our study is to verify, whether percutaneous mitral annuloplasty results in reverse remodeling in patients with functional mitral regurgitation (FMR) and impaired ejection fraction (EF) and to investigate which echo parameters may help in prediction of the efficacy of the procedure. BACKGROUND: FMR exacerbates left ventricular (LV) dilatation and contributes to both LV remodeling and heart failure. METHODS: We analyzed baseline and 1 month follow-up data in 22 consecutive patients with FMR, who underwent successful percutaneous trans-coronary venous mitral annuloplasty with the Carillon device. RESULTS: Significant reduction of FMR echo parameters, including vena contracta (VC), effective regurgitant orifice area (EROA), and regurgitant volume (RV) were observed and maintained throughout 1 month follow up and did not correlate with baseline annular, LV or with the left atrial diameters. Baseline mitral tenting area correlated negatively with the relative improvement (% difference) of EROA (r = -0.5898) and RV (r = -0.4363), but not with VC (r = 0.1341). In addition, increased EF as well as a significant reduction in left ventricular diameters were noted. The increase in EF negatively correlated with the change in EROA (r = -0.50058), PISA (r = -0.5327), and RV (r = -0.5457). Baseline mitral tenting area significantly correlated with the 1 month change in EF (r = 0.5946) and stroke volume (r = 0.6913). CONCLUSIONS: The improvement of FMR after treatment with the Carillon device is associated with LV reverse remodeling and an increase in systolic performance, that correlates with the reduction in mitral regurgitation, being not dependent on baseline heart diameters. Mitral tenting area seems to be an important parameter in prediction of benefit from percutaneous mitral annuloplasty.


Assuntos
Vasos Coronários/cirurgia , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Adulto , Idoso , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/instrumentação , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Polônia , Recuperação de Função Fisiológica , Sistema de Registros , Volume Sistólico , Resultado do Tratamento , Remodelação Ventricular
6.
Europace ; 17(7): 1153-6, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25750216

RESUMO

AIMS: Inferior vena cava (IVC) interruption is a rare anatomic variant where the azygos vein (AV) drains the blood from the IVC to the upper part of the right atrium via the superior vena cava. Here, we report balloon cryoablation of the pulmonary veins (PVs) via superior access in a patient with atrial fibrillation. METHODS AND RESULTS: After the first failed ablation attempt due to IVC interruption, balloon cryoablation with a 28-mm Arctic Front Advance cryoballoon (Medtronic CryoCath LP, Quebec, Canada) via superior access was performed; it requires only a single transseptal puncture (TP), and the patient had optimal PV anatomy. Deflectable electrodes were inserted into the right ventricle and coronary sinus from the right femoral vein. The right internal jugular vein was accessed using an SL0 transseptal sheath and BRK needle. The TP was performed under transoesophageal echocardiographic guidance with a Safe Sept wire because the septum was stiff. All PVs were engaged: the left using an ablation catheter before balloon insertion and the inferior following a 'push-up' technique because of a leak above the veins. Cryothermal energy was delivered after checking for occlusion. The procedure lasted 210 min, fluoroscopy time was 78 min, and air-kerma dose was 194 mGy. During the 6-month follow-up, no episodes of atrial fibrillation were detected on several Holter recordings. CONCLUSIONS: Successful PV isolation in patients with AV continuation of an interrupted IVC can be safely performed using superior access with balloon cryoablation, after several modifications of standard equipment.


Assuntos
Fibrilação Atrial/cirurgia , Veia Ázigos/anormalidades , Criocirurgia/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Veia Cava Inferior/anormalidades , Idoso , Veia Ázigos/cirurgia , Cateterismo Cardíaco/métodos , Feminino , Humanos , Punções/métodos , Resultado do Tratamento , Veia Cava Inferior/cirurgia
7.
Kardiol Pol ; 82(3): 308-314, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38493457

RESUMO

BACKGROUND: Remote monitoring (RM) of cardiac implantable electronic devices for adults offers improved treatment efficacy and, consequently, better patient clinical outcomes. There is scant data on the value and prognosis of RM in the pediatric population. AIMS: The goal of this study was to determine the efficacy of RM by analyzing the connectivity of bedside transmitters, adherence to planned automatic follow-ups, and occurrence of alert-based events. METHODS: We evaluated the pediatric population with implanted pacemakers for congenital AV block or after surgically corrected congenital heart diseases. RESULTS: A total of 69 patients were included in our study. The median (Q1-Q3) patient age was 6.0 (2.0-11.0) years. All patients received bedside transmitters and were enrolled in the RM system. Among them, 95.7% of patients had their first scheduled follow-up successfully sent. Patients were followed up remotely over a median time of 33.0 (13-45) months. Only 42% of patients were continuously monitored, and all scheduled transmissions were delivered on time. Further analysis revealed that 34.8% of patients missed transmissions between June and September (holiday season). Alert-based events were observed in 40.6% patients, mainly related to epicardial lead malfunction and arrhythmic events. Overall compliance was also compromised by socioeconomic factors. CONCLUSIONS: Our findings are in concordance with recently published results by PACES regarding a high level of compliance in patient enrollment to RM and time to initial transmission. However, a lower level of adherence was observed during the holiday season due to interrupted connectivity of bedside transmitters. Importantly, a relatively low occurrence of alert transmissions was observed, mainly related to epicardial lead malfunction and arrhythmic events.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Adulto , Humanos , Criança , Tecnologia de Sensoriamento Remoto/métodos , Monitorização Fisiológica/métodos , Arritmias Cardíacas/terapia
8.
J Clin Med ; 13(14)2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39064130

RESUMO

Background/Objectives: Persistent cardiovascular issues are common in COVID-19 survivors, making the detection of subtle myocardial injuries critical. This study evaluates myocardial work (MW) indices in patients recently recovering from mild-to-moderate COVID-19. Methods: A total of 105 recently recovered COVID-19 patients (who had a mean age of 52 years) underwent comprehensive laboratory testing and advanced echocardiographic assessments. The median time since their COVID-19 infections was 56 days (IQR: 42-71). The cohort was stratified based on high-sensitive troponin I (hs-TnI) levels: undetectable versus detectable. The echocardiographic analysis utilized pressure-strain loops to evaluate MW indices. Results: Detectable hs-TnI levels were observed in 42% of patients. The median values of MW indices for the entire group were slightly below normal values: global work index (GWI)-1834 mmHg% (IQR 1168-2054 mmHg%), global constructive work (GCW)-2130 mmHg% (IQR 2010-2398 mmHg%), global wasted work (GWW)-119 mmHg% (IQR 78-175 mmHg%), and global work efficiency (GWE)-94% (IQR 92-96%). Patients with detectable hs-TnI had higher GWW (168 vs. 97 mmHg%, p < 0.005) and lower GWE (93% vs. 95%, p < 0.005). In multiple regression analysis, strain dispersion (PSD) was the sole predictor for GWW (ß = 0.67, p < 0.001), while for GWE, PSD (ß = -0.67, p < 0.001) and LVEF (ß = 0.16, p = 0.05) were significant predictors. Conclusions: Among patients recently recovering from mild-to-moderate COVID-19, elevated hs-TnI levels are linked with a reduction in GWE and an increase in GWW. PSD is an important predictor of myocardial inefficiency and wasted work. In this group, disruptions in the timing and coordination of cardiac muscle contractions may play a key pathophysiological role in reducing the efficiency of the heart's performance.

9.
Kardiol Pol ; 82(2): 192-199, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38493473

RESUMO

BACKGROUND: To our knowledge, no studies have assessed quality of life (QoL) in asymptomatic children with a preexcitation electrocardiogram pattern. AIM: To evaluate the QoL of children with asymptomatic Wolff-Parkinson-White (WPW) syndrome. METHODS: This study involved QoL assessment of 31 children with asymptomatic preexcitation and 82 healthy children using the WHOQOL-BREF and the Pediatric Arrhythmia Related Score (PARS), a specific questionnaire that we have developed, which is related to patients' feelings and observations concerning arrhythmia. RESULTS: There were no significant differences between the two groups in all the measured domains; however, there were significant differences regarding general satisfaction with their health condition (P = 0.01). There were no differences in general satisfaction with the QoL, but WPW children more often experienced palpitations than the control group (P <0.001) and were more likely to feel sad (P = 0.046) and nervous (P = 0.04) compared to healthy children. CONCLUSIONS: The children with WPW were more dissatisfied with their health compared to healthy children. Although both groups of children had similar levels of satisfaction with their QoL, some areas of physical and psychological parameters of QoL were worse in WPW children. The PARS questionnaire is a useful tool as a disease-specific QoL instrument, which supplements the general questionnaire and aids in clinical practice and decision-making.


Assuntos
Qualidade de Vida , Síndrome de Wolff-Parkinson-White , Humanos , Criança , Eletrocardiografia , Inquéritos e Questionários , Ansiedade
12.
BMC Pediatr ; 13: 27, 2013 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-23421922

RESUMO

BACKGROUND: Kearns-Sayre Syndrome (KSS) is a multisystem disorder caused by a dysfunction of the oxidative phosphorylation system within mitochondria. Mitochondrial DNA (mtDNA) rearrangements are a key molecular feature of this disease, which manifest a broad phenotypic spectrum. CASE PRESENTATION: Here, we present a boy with KSS whose symptoms included cardiac conduction deficit, cardiomyopathy and growth hormone (GH) deficiency. The patient showed typical symptoms for KSS from early childhood (chronic progressive external ophthalmoplegia, retinopathy, short stature). Long-range PCR analysis disclosed a 7663-base pair heteroplasmic deletion in the mtDNA encompassing nucleotides 6340-14003. At 12 years of age, GH deficiency was recognized and recombinant growth hormone (rGH) therapy was started. At 15 years of age, a complete atrioventicular block was diagnosed and the patient received a pacemaker. During the following 6 months, progressive deterioration of the left ventricle was observed and an echocardiogram showed features of dilated cardiomyopathy. The rGH treatment was then discontinued at a final height of 163 cm. Unfortunately, due to multi-organ insufficiency and inflammation, the patient died at the age of 18 years. CONCLUSIONS: The response to rGH therapy in the patient was very satisfactory. The large mtDNA deletion had no apparent impact on the response to rGH. Cardiac disturbances occurred as part of the syndrome and were not related to rGH therapy; however, the progression of the disease led to death.


Assuntos
Sequência de Bases , DNA Mitocondrial , Síndrome de Kearns-Sayre/genética , Deleção de Sequência , Adolescente , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/etiologia , Evolução Fatal , Transtornos do Crescimento/tratamento farmacológico , Transtornos do Crescimento/etiologia , Hormônio do Crescimento Humano/deficiência , Hormônio do Crescimento Humano/uso terapêutico , Humanos , Síndrome de Kearns-Sayre/complicações , Síndrome de Kearns-Sayre/diagnóstico , Masculino , Proteínas Recombinantes
13.
Cardiol J ; 30(5): 762-770, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34355779

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the leading cause of stroke. The European Society of Cardiology (ESC) advises opportunistic AF screening among patients aged ≥ 65 years. Considering this, the aim herein, was compare the feasibility of two different systems of smartphone-based electrocardiogram (ECG) recordings to identify AF among those without a previous arrhythmia history. METHODS: Prospective AF screening was conducted at six pharmacies using Kardia Mobile and Hartmann Veroval 2 in 1. A single-lead ECG was acquired by the placement of fingers on the pads. A cardiologist evaluated findings from both devices. RESULTS: Atrial fibrillation was identified in 3.60% and previously unknown AF was detected in 1.92% of the study participants. Sensitivity and specificity of the Kardia application in detecting AF were 66.7% (95% confidence interval [CI] 38.4-88.2%) and 98.5% (95% CI 96.7-99.5%), and for Veroval 10.0% (95% CI 0.23-44.5%) and 94.96% (95% CI 92.15-96.98%), accordingly. Inter-rater agreement was k = 0.088 (95% CI 1.59-16.1%). CONCLUSIONS: Mobile devices can detect AF, but each finding must be verified by a professional. The Kardia application appeared to be more user-friendly than Veroval. Cardiovascular screening using mobile devices is feasible at pharmacies. Hence it might be considered for routine use.


Assuntos
Fibrilação Atrial , Humanos , Estudos Prospectivos , Smartphone , Frequência Cardíaca , Eletrocardiografia
14.
Kardiol Pol ; 80(12): 1238-1247, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36069197

RESUMO

BACKGROUND: The Managed Care for Acute Myocardial Infarction Survivors (MACAMIS) program introduced for patients after myocardial infarction (MI) consists of 4 modules including early cardiac rehabilitation (CR). AIMS: We compared the impact of CR on survival of patients after MI included in the MACAMIS program. METHODS: Patients in MACAMIS were divided into subgroups based on being qualified or not qual-ified for CR and on whether they completed or failed to complete CR. We evaluated one-, two-, and three-year mortality. RESULTS: Of 244 patients in MACAMIS, 174 patients were qualified for CR. They were younger, had less advanced coronary artery disease (CAD), higher ejection fraction (EF), and fewer comorbidities. Finally, 102 (58.6%) patients completed CR. These patients were younger and more likely to have STEMI; they were more often treated invasively, with no differences in comorbidity burden. The survival rates at one, two, and three years were 93.6%, 87.8%, and 65.0%, respectively. Patients who qualified for CR had a better prognosis. The mortality rates at one, two, and three years were 2.38% vs. 16.18% (P = 0.0003), 6.71% vs. 25.4% (P = 0.002), and 26.87% vs. 51.35% (P = 0.01), respectively. Patients who completed CR, again, had a significantly better prognosis. The mortality rate was 1% vs. 10.29% (P = 0.009), 4.17% vs. 17.56% (P = 0.002), and 23.33% vs. 40.54% (P = 0.09) in analyzed periods. The only independent factors related to survival were completion of CR and number of comorbidities. CONCLUSIONS: Patients with MI in the MACAMIS program had better prognosis when participating in CR. After completing the MACAMIS program, increased mortality was observed in the following years. Despite the flexibility of the CR program, the proportion of patients who qualified and completed CR remained low.


Assuntos
Reabilitação Cardíaca , Doença da Artéria Coronariana , Infarto do Miocárdio , Humanos , Polônia , Infarto do Miocárdio/terapia , Programas de Assistência Gerenciada
15.
Emerg Med Int ; 2021: 5584632, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33981460

RESUMO

BACKGROUND: Successful defibrillation is commonly followed by a transient nonperfusing state. To provide perfusion in this stagnant phase, chest compressions are recommended irrespective of arrhythmia termination. Implantable cardioverters-defibrillators (ICD) used immediately after delivery of the shock are capable of pacing the heart, and this feature is commonly activated in these devices. Potential utility of external, transcutaneous postshock pacing in patients with SCA in shockable rhythms has not been determined. This study aimed at presenting an impact of a short-term external postshock pacing (ePSP) on a quality of chest compressions (CC) without compromising them. METHODS: The study was designed as a high-fidelity simulation study. Twenty triple-paramedic teams were invited. Participants were asked to take part in a 10-minute adult cardiac arrest scenario with ventricular fibrillation. In the first simulation, paramedics had to resume compressions after each shock (control group). In the second, simultaneous with compressions, one of the rescuers started transcutaneous pacing (TCP) with a current output of 200 mA and a pacer rate of 80 ppm. TCP was finished after 30 seconds (experimental group). The primary outcomes were chest compression fraction (CCF), mean depth and rate of compressions, percent of fully recoiled compressions, and percent of compressions of correct depth and their rate. RESULTS: In both experimental and control group, CCF, mean depth, and rate were similar (84.65 ± 3.67 vs. 85.45 ± 4.95, p=0.54; 55.75 ± 3.40 vs. 55.25 ± 2.73, p=0.63; 122.70 ± 4.92 vs. 120.80 ± 6.00, p=0.25, respectively). In turn, percent of CC performed in correct depth, rate, and recoil was unsatisfactory in both groups (51.00 ± 17.40 vs. 52.60 ± 18.72, p=0.76; 122.70 ± 4.92 vs. 120.80 ± 6.00, p=0.25, respectively). Small differences were not statistically significant. Moreover, appropriate hand-positioning was observed more frequently in the control group, and this was the only significant difference (95.60 ± 5.32 vs. 99.30 ± 1.59, p=0.006). CONCLUSION: This difference was statistically significant (p < 0.01). Introducing an ePSP does not influence relevantly the quality of CC.

16.
Diagnostics (Basel) ; 11(8)2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34441357

RESUMO

The left ventricular summit (LVS) is a triangular area located at the most superior portion of the left epicardial ventricular region, surrounded by the two branches of the left coronary artery: the left anterior interventricular artery and the left circumflex artery. The triangle is bounded by the apex, septal and mitral margins and base. This review aims to provide a systematic and comprehensive anatomical description and proper terminology in the LVS region that may facilitate exchanging information among anatomists and electrophysiologists, increasing knowledge of this cardiac region. We postulate that the most dominant septal perforator (not the first septal perforator) should characterize the LVS definition. Abundant epicardial adipose tissue overlying the LVS myocardium may affect arrhythmogenic processes and electrophysiological procedures within the LVS region. The LVS is divided into two clinically significant regions: accessible and inaccessible areas. Rich arterial and venous coronary vasculature and a relatively dense network of cardiac autonomic nerve fibers are present within the LVS boundaries. Although the approach to the LVS may be challenging, it can be executed indirectly using the surrounding structures. Delivery of the proper radiofrequency energy to the arrhythmia source, avoiding coronary artery damage at the same time, may be a challenge. Therefore, coronary angiography or cardiac computed tomography imaging is strongly recommended before any procedure within the LVS region. Further research on LVS morphology and physiology should increase the safety and effectiveness of invasive electrophysiological procedures performed within this region of the human heart.

17.
Medicine (Baltimore) ; 99(21): e19970, 2020 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-32481260

RESUMO

INTRODUCTION: The RF ablation of ventricular tachycardia (VT) or atrial flutter (AFl) can be unsuccessful due to lack of lesion transmurality. Bipolar ablation (BA) is more successful than unipolar ablation (UA). The purpose of our study was to investigate the long-term effect of BA ablation in patients after failed UA. METHODS: Patients with septal VT (5) or AFL (2) after 2 to 5 unsuccessful UA were prospectively analysed after BA. All patients presented with heart failure or had ICD interventions. RESULTS: BA was successful in 5 patients (1 failure each in the AFL and VT group). The follow-up duration was 10 to 26 months. In AFL group, BA was successful in 1 patient, unidirectional cavotricuspid block in was achieved in the other patient. All patients were asymptomatic for 12 months, but 1 had atrial fibrillation and the other had AFL reablation 19 months after BA. In VT group, all patients had several forms of septal VT. BA was successful in 4 patients. In 2 patients with high septal VT BA resulted in complete atrioventricular block. During follow-up, 1 patient had VT recurrence 26 months after BA and died after an unsuccessful reablation. Three patients had VT recurrences of different morphologies, which required reablation (UA in 2 and alcohol septal ablation in the other patient). CONCLUSION: BA was successful in patients with AFL and septal VT resistant to standard ablation. Relapses of clinical arrhythmia are rare; however, long-term follow-up is complicated by recurrences of different arrhythmias related to complex arrhythmogenic substrate.


Assuntos
Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Irrigação Terapêutica , Fatores de Tempo , Resultado do Tratamento
18.
J Cardiovasc Pharmacol Ther ; 25(2): 142-151, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31578088

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common cardiac arrhythmia. Thus, the aim of our study was to evaluate the smartphone-based electrocardiogram (ECG) recordings aimed at AF screening at Polish pharmacies. METHODS: Prospective AF screening among patients aged ≥65 years was conducted at 10 pharmacies using Kardia Mobile with a dedicated application (Kardia app). Prior AF was a study exclusion criterion. CHA2DS2-VASc score (congestive heart failure, hypertension, age, diabetes mellitus, previous stroke/transient ischemic attack, female sex, and vascular disease) has been collected from every patient. A single-lead ECG has been acquired by the placement of fingers from each hand on the pads. Kardia app diagnosis has been evaluated by the cardiologist. RESULTS: A total of 525 ECGs were performed. Kardia app diagnosis was provided in 490 cases. In 437 (89.18%) cases, it was "normal" rhythm, in 17 (3.47%) recordings "possible AF," in 23 (4.69%) ECGs "unreadable," and in 13 (2.65%) "unclassified". After the cardiologist reevaluation, the new AF was identified in 7 (1.33%) patients. Sensitivity and specificity of Kardia app in detecting AF was 100% (95% confidence interval [CI]: 71.5%-100%) and 98.7% (95% CI: 97.3%-99.5%), respectively. The positive predictive value was 64.7% (95% CI: 38.3%-85.7%) and the negative predictive value was 100% (95% CI: 99.2%-100%). CHA2DS2-VASc score was 2.14 ± 0.69 for those with new AF and 3.33 ± 1.26 in the non-AF group. CONCLUSION: Kardia app is capable of fast screening and detecting AF with high sensitivity and specificity. The possible diagnosis of AF deserves additional cardiological evaluation. The results obtained in patients with low CHA2DS2-VASc score and "silent" AF confirm the importance of routine AF screening. Cardiovascular screening with the use of mobile health technology is feasible at pharmacies.


Assuntos
Fibrilação Atrial/diagnóstico , Serviços Comunitários de Farmácia , Eletrocardiografia , Programas de Rastreamento , Telemedicina , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Fibrilação Atrial/fisiopatologia , Eletrocardiografia/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Programas de Rastreamento/instrumentação , Aplicativos Móveis , Polônia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Smartphone , Telemedicina/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA