Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 48(1): 37-40, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36563364

RESUMO

We demonstrate the integration of micro-electro-mechanical-systems (MEMS) scanning mirrors as active elements for the local optical pumping of ultra-cold atoms in a magneto-optical trap. A pair of MEMS mirrors steer a focused resonant beam through a cloud of trapped atoms shelved in the F = 1 ground-state of 87Rb for spatially selective fluorescence of the atom cloud. Two-dimensional control is demonstrated by forming geometrical patterns along the imaging axis of the cold atom ensemble. Such control of the atomic ensemble with a microfabricated mirror pair could find applications in single atom selection, local optical pumping, and arbitrary cloud shaping. This approach has significant potential for miniaturization and in creating portable control systems for quantum optic experiments.

2.
Opt Express ; 28(21): 31714-31728, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33115138

RESUMO

Light trapping is a commonly used technique for enhancing the efficiency of solar collection in many photovoltaic (PV) devices. In this paper, we present the design of multi-layer light trapping structures that can potentially be retrofitted, or directly integrated, onto crystalline or amorphous silicon solar panels for enhanced optical collection at normal and extreme angle of incidence. This approach can improve the daily optical collection performance of solar panel with and without internally integrated light trapping structure by up to 7.18% and 159.93%, respectively. These improvements predict an enhancement beyond many research level and commercially deployed light trapping technologies. We further enhance this performance by combining our multi-layer optics with high refractive index materials to achieve a daily optical collection of up to 32.20% beyond leading light trapping structures. Our additive light trapping designs could enable the upgradeability of older PV technologies and can be tailored to optimally operate at unique angular ranges for building exteriors or over a wide range of incidence angle for applications such as unmanned aerial vehicles.

3.
Am Heart J ; 215: 91-94, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31295633

RESUMO

Given the current increase in the incidence of coronary artery disease in younger women as well as the high lifetime risk of developing an x-ray-induced malignancy in this population, we aimed at assessing chest radiation in 206 women ≤55 years old undergoing coronary calcium scoring (CACS) by using a Monte Carlo simulation tool. Our data indicate that the simulated radiation dose of the female breast during CACS depends substantially on the starting position of the x-ray tube, with an almost 2 times excess of breast radiation exposure being measured during anterior-posterior tube positioning. Thus, an additional technical feature taking into account the position of the x-ray tube when acquisition is triggered might be an important tool to reduce radiation exposure of the female breast during CACS.


Assuntos
Mama/efeitos da radiação , Simulação por Computador , Doença da Artéria Coronariana/diagnóstico , Exposição à Radiação/efeitos adversos , Lesões por Radiação/prevenção & controle , Intensificação de Imagem Radiográfica/instrumentação , Tomografia Computadorizada por Raios X/efeitos adversos , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Doses de Radiação , Lesões por Radiação/etiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
4.
Eur J Nucl Med Mol Imaging ; 46(12): 2429-2451, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31410539

RESUMO

These guidelines update the previous EANM 2009 guidelines on the diagnosis of pulmonary embolism (PE). Relevant new aspects are related to (a) quantification of PE and other ventilation/perfusion defects; (b) follow-up of patients with PE; (c) chronic PE; and (d) description of additional pulmonary physiological changes leading to diagnoses of left ventricular heart failure (HF), chronic obstructive pulmonary disease (COPD) and pneumonia. The diagnosis of PE should be reported when a mismatch of one segment or two subsegments is found. For ventilation, Technegas or krypton gas is preferred over diethylene triamine pentaacetic acid (DTPA) in patients with COPD. Tomographic imaging with V/PSPECT has higher sensitivity and specificity for PE compared with planar imaging. Absence of contraindications makes V/PSPECT an essential method for the diagnosis of PE. When V/PSPECT is combined with a low-dose CT, the specificity of the test can be further improved, especially in patients with other lung diseases. Pitfalls in V/PSPECT interpretation are discussed. In conclusion, V/PSPECT is strongly recommended as it accurately establishes the diagnosis of PE even in the presence of diseases like COPD, HF and pneumonia and has no contraindications.


Assuntos
Guias de Prática Clínica como Assunto , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/fisiopatologia , Sociedades Médicas , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Relação Ventilação-Perfusão , Europa (Continente) , Humanos , Sensibilidade e Especificidade
5.
Eur Radiol ; 28(5): 2143-2150, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29218617

RESUMO

OBJECTIVES: To investigate the impact of an adaptive detector collimation on the dose parameters and accurateness of scan length adaption at prospectively ECG-triggered sequential cardiac CT with a wide-detector third-generation dual-source CT. METHODS: Ideal scan lengths for human hearts were retrospectively derived from 103 triple-rule-out examinations. These measures were entered into the new scanner operated in prospectively ECG-triggered sequential cardiac scan mode with three different detector settings: (1) adaptive collimation, (2) fixed 64 × 0.6-mm collimation, and (3) fixed 96 × 0.6-mm collimation. Differences in effective scan length and deviation from the ideal scan length and dose parameters (CTDIvol, DLP) were documented. RESULTS: The ideal cardiac scan length could be matched by the adaptive collimation in every case while the mean scanned length was longer by 15.4% with the 64 × 0.6 mm and by 27.2% with the fixed 96 × 0.6-mm collimation. While the DLP was almost identical between the adaptive and the 64 × 0.6-mm collimation (83 vs. 89 mGycm at 120 kV), it was 62.7% higher with the 96 × 0.6-mm collimation (135 mGycm), p < 0.001. CONCLUSION: The adaptive detector collimation for prospectively ECG-triggered sequential acquisition allows for adjusting the scan length as accurate as this can only be achieved with a spiral acquisition. This technique allows keeping patient exposure low where patient dose would significantly increase with the traditional step-and-shoot mode. KEY POINTS: • Adaptive detector collimation allows keeping patient exposure low in cardiac CT. • With novel detectors the desired scan length can be accurately matched. • Differences in detector settings may cause 62.7% of excessive dose.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Eletrocardiografia , Tomografia Computadorizada Multidetectores/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação
6.
Eur Radiol ; 28(7): 2756-2762, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29417250

RESUMO

OBJECTIVES: We investigated the potential reduction of patient exposure during invasive coronary angiography (ICA) if the procedure had only been directed to the vessel with at least one ≥ 50% stenosis as described in the CT report. METHODS: Dose reports of 61 patients referred to ICA because of at least one ≥ 50% stenosis on coronary CT angiography (CCTA) were included. Dose-area product (DAP) was documented separately for left (LCA) and right coronary arteries (RCA) by summing up the single DAP for each angiographic projection. The study population was subdivided as follows: coronary intervention of LCA (group 1) or RCA (group 2) only, or of both vessels (group 3), or further bypass grafting (group 4), or no further intervention (group 5). RESULTS: 57.4% of the study population could have benefitted from reduced exposure if catheterization had been directly guided to the vessel of interest as described on CCTA. Mean relative DAP reductions were as follows: group 1 (n = 18), 11.2%; group 2 (n = 2), 40.3%; group 3 (n = 10), 0%; group 4 (n = 3), 0%; group 5 (n = 28), 28.8%. CONCLUSIONS: Directing ICA to the vessel with stenosis as described on CCTA would reduce intraprocedural patient exposure substantially, especially for patients with single-vessel stenosis. KEY POINTS: • Patients with CAD can benefit from decreased radiation exposure during coronary angiography. • ICA should be directed solely to significant stenoses as described on CCTA. • Severely calcified plaques remain a limitation of CCTA leading to unnecessary ICA referrals.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Idoso , Doença da Artéria Coronariana/patologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/patologia , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Índice de Gravidade de Doença , Tórax
7.
Acta Radiol ; 59(8): 909-916, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29105487

RESUMO

Background Image quality benefits from high-pitch scanning in agitated patients by reducing acquisition time. Purpose To compare image quality and exposure parameters in patients with maxillofacial trauma on second- and third-generation dual-source computed tomography (DSCT). Material and Methods Four groups were compared. Group 1 was examined on second-generation DSCT (120 kV/50 mAs, pitch 3.0). The other three groups were examined on third-generation DSCT. Group 2 was scanned with 120 kV/50 mAs, pitch 2.2. Automated exposure control (AEC) was used in group 3 and group 4 with pitch factors of 2.2 and 3.0, respectively. Images of third-generation DSCT were reconstructed with iterative reconstruction (IR), of second-generation DSCT with filtered back-projection. CTDIvol, acquisition time, and image quality were compared. Results Thirty patients were included in each group. Average CTDIvol (2.76 ± 0.00 mGy, 2.66 ± 0.00 mGy, 0.74 ± 0.23 mGy, and 0.75 ± 0.17 mGy) was significantly lower on third-generation DSCT with AEC ( P < 0.001). Subjective image quality was rated worst in group 4 due to strong high-pitch artifacts, while in the remaining three groups it was rated good or very good with good inter-observer agreement (k > 0.64). Average acquisition time was significantly shorter with third-generation DSCT (0.47 s, 0.36 s, 0.38 s, 0.30 s; P < 0.001). Conclusion Third-generation DSCT yields faster acquisition times and substantial dose reduction with AEC. A pitch of 2.2 should be preferred, as it results in fewer artifacts. If AEC is used, latest IR ensures that diagnostic image quality is guaranteed.


Assuntos
Artefatos , Traumatismos Maxilofaciais/diagnóstico por imagem , Seios Paranasais/diagnóstico por imagem , Agitação Psicomotora/complicações , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Fatores de Tempo , Adulto Jovem
8.
Eur Radiol ; 27(8): 3290-3299, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28093625

RESUMO

PURPOSE: To prospectively evaluate the accuracy of ultralow radiation dose CT of the chest with tin filtration at 100 kV for pulmonary nodule detection. MATERIALS AND METHODS: 202 consecutive patients undergoing clinically indicated chest CT (standard dose, 1.8 ± 0.7 mSv) were prospectively included and additionally scanned with an ultralow dose protocol (0.13 ± 0.01 mSv). Standard dose CT was read in consensus by two board-certified radiologists to determine the presence of lung nodules and served as standard of reference (SOR). Two radiologists assessed the presence of lung nodules and their locations on ultralow dose CT. Sensitivity and specificity of the ultralow dose protocol was compared against the SOR, including subgroup analyses of different nodule sizes and types. A mixed effects logistic regression was used to test for independent predictors for sensitivity of pulmonary nodule detection. RESULTS: 425 nodules (mean diameter 3.7 ± 2.9 mm) were found on SOR. Overall sensitivity for nodule detection by ultralow dose CT was 91%. In multivariate analysis, nodule type, size and patients BMI were independent predictors for sensitivity (p < 0.001). CONCLUSIONS: Ultralow dose chest CT at 100 kV with spectral shaping enables a high sensitivity for the detection of pulmonary nodules at exposure levels comparable to plain film chest X-ray. KEYPOINTS: • 91% of all lung nodules were detected with ultralow dose CT • Sensitivity for subsolid nodule detection is lower in ultralow dose CT (77.5%) • The mean effective radiation dose in 202 patients was 0.13 mSv • Ultralow dose CT seems to be feasible for lung cancer screening.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Detecção Precoce de Câncer/métodos , Estudos de Viabilidade , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Sensibilidade e Especificidade , Adulto Jovem
9.
Eur Radiol ; 27(2): 705-714, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27236818

RESUMO

OBJECTIVES: To evaluate objective and subjective image quality of a noise-optimized virtual monoenergetic imaging (VMI+) reconstruction technique in dual-energy computed tomography (DECT) angiography prior to transcatheter aortic valve replacement (TAVR). METHODS: Datasets of 47 patients (35 men; 64.1 ± 10.9 years) who underwent DECT angiography of heart and vascular access prior to TAVR were reconstructed with standard linear blending (F_0.5), VMI+, and traditional monoenergetic (VMI) algorithms in 10-keV intervals from 40-100 keV. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of 564 arterial segments were evaluated. Subjective analysis was rated by three blinded observers using a Likert scale. RESULTS: Mean SNR and CNR were highest in 40 keV VMI+ series (SNR, 27.8 ± 13.0; CNR, 26.3 ± 12.7), significantly (all p < 0.001) superior to all VMI series, which showed highest values at 70 keV (SNR, 18.5 ± 7.6; CNR, 16.0 ± 7.4), as well as linearly-blended F_0.5 series (SNR, 16.8 ± 7.3; CNR, 13.6 ± 6.9). Highest subjective image quality scores were observed for 40, 50, and 60 keV VMI+ reconstructions (all p > 0.05), significantly superior to all VMI and standard linearly-blended images (all p < 0.01). CONCLUSIONS: Low-keV VMI+ reconstructions significantly increase CNR and SNR compared to VMI and standard linear-blending image reconstruction and improve subjective image quality in preprocedural DECT angiography in the context of TAVR planning. KEY POINTS: • VMI+ combines increased contrast with reduced image noise. • VMI+ shows substantially less image noise than traditional VMI. • 40-keV reconstructions show highest SNR/CNR of the aortic and iliofemoral access route. • Observers overall prefer 60 keV VMI+ images. • VMI+ DECT imaging helps improve image quality for TAVR planning.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído , Cirurgia Assistida por Computador , Substituição da Valva Aórtica Transcateter/métodos
10.
AJR Am J Roentgenol ; 208(5): 1089-1096, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28245141

RESUMO

OBJECTIVE: The purpose of our study was to determine diagnostic accuracy, image quality, and radiation dose of low-dose single- and dual-energy unenhanced third-generation dual-source head CT for detection of intracranial hemorrhage (ICH). MATERIALS AND METHODS: A total of 123 patients with suspected ICH were examined using a dual-source 192-MDCT scanner. Standard-dose 120-kVp single-energy CT (SECT; n = 36) and 80-kVp and 150-kVp dual-energy CT (DECT; n = 30) images were compared with low-dose SECT (n = 32) and DECT (n = 25) images obtained using automated tube current modulation (ATCM). Advanced modeled iterative reconstruction (ADMIRE) was used for all protocols. Detection of ICH was performed by three readers who were blinded to the image acquisition parameters of each image series. Image quality was assessed both quantitatively and qualitatively. Interobserver agreement was calculated using the Fleiss kappa. Radiation dose was measured as dose-length product (DLP). RESULTS: Detection of ICH was excellent (sensitivity, 94.9-100%; specificity, 94.7-100%) in all protocols (p = 1.00) with perfect interobserver agreement (0.83-0.96). Qualitative ratings showed significantly better ratings for both standard-dose protocols regarding gray matter-to-white matter contrast (p ≤ 0.014), whereas highest gray matter-to-white matter contrast-to-noise ratio was observed with low-dose DECT images (p ≥ 0.057). The lowest posterior fossa artifact index was measured for standard-dose DECT, which showed significantly lower values compared with low-dose protocols (p ≤ 0.034). Delineation of ventricular margins and sharpness of subarachnoidal spaces were rated excellent in all protocols (p ≥ 0.096). Low-dose techniques lowered radiation dose by 26% for SECT images (DLP, 575.0 ± 72.3 mGy · cm vs 771.5 ± 146.8 mGy · cm; p < 0.001) and by 24% in DECT images (DLP, 587.0 ± 103.2 mGy · cm vs 770.6 ± 90.2 mGy · cm; p < 0.001). No significant difference was observed between the low-dose protocols (p = 1.00). CONCLUSION: Low-dose unenhanced head SECT and DECT using ATCM and ADMIRE provide excellent diagnostic accuracy for detection of ICH with good quantitative and qualitative image quality in third-generation dual-source CT while allowing significant radiation dose reduction.


Assuntos
Hemorragias Intracranianas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Radiometria/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
11.
Radiology ; 280(2): 510-9, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26928067

RESUMO

Purpose To evaluate whether a dual-energy (DE) computed tomographic (CT) virtual noncalcium technique can improve the detection rate of acute thoracolumbar vertebral compression fractures in patients with osteoporosis compared with that at magnetic resonance (MR) imaging depending on the level of experience of the reading radiologist. Materials and Methods This retrospective study was approved by the institutional ethics committee. Informed consent was obtained from all patients. Forty-nine patients with osteoporosis who were suspected of having acute vertebral fracture underwent DE CT and MR imaging. Conventional linear-blended CT scans and corresponding virtual noncalcium reconstructions were obtained. Five radiologists with varying levels of experience evaluated gray-scale CT scans for the presence of fractures and their suspected age. Then, virtual noncalcium images were evaluated to detect bone marrow edema. Findings were compared with those from MR imaging (the standard of reference). Sensitivity and specificity analyses for diagnostic performance and matched pair analyses were performed on vertebral fracture and patient levels. Results Sixty-two fractures were classified as fresh and 52 as old at MR imaging. The diagnostic performance of all readers in the detection of fresh fractures improved with the addition of virtual noncalcium reconstructions compared with that with conventional CT alone. Although the diagnostic accuracy of the least experienced reader with virtual noncalcium CT (accuracy with CT alone, 61%; accuracy with virtual noncalcium technique, 83%) was within the range of that of the most experienced reader with CT alone, the latter improved his accuracy with the noncalcium technique (from 81% to 95%), coming close to that with MR imaging. The number of vertebrae rated as unclear decreased by 59%-90% or from 15-53 to 2-13 in absolute numbers across readers. The number of patients potentially referred to MR imaging decreased by 36%-87% (from 11-23 to 2-10 patients). Considering the gain in true decisions with the virtual noncalcium technique on a patient level, between 12 (most experienced reader) and 17 (least experienced reader) MR examinations could have been avoided. Conclusion The DE CT-based virtual noncalcium technique may enable depiction of bone marrow edema in thoracolumbar vertebral compression fractures in patients with osteoporosis, with good accordance with MR imaging when images are read by experienced radiologists. Although less experienced readers improved their diagnostic performance to some degree, the experienced reader's diagnostic performance approached that with MR imaging. (©) RSNA, 2016.


Assuntos
Medula Óssea/diagnóstico por imagem , Fraturas por Compressão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Osteoporose/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Competência Clínica/estatística & dados numéricos , Edema/complicações , Edema/diagnóstico por imagem , Feminino , Fraturas por Compressão/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral/complicações , Coluna Vertebral/diagnóstico por imagem
12.
Eur Radiol ; 26(8): 2623-31, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26560726

RESUMO

PURPOSE: To evaluate image quality and radiation dose in third-generation dual-source computed tomography (DSCT) of the neck using automated tube voltage adaptation (TVA) with advanced modelled iterative reconstruction (ADMIRE) algorithm. METHODS: One hundred and sixteen patients were retrospectively evaluated. Group A (n = 59) was examined on second-generation DSCT with automated TVA and filtered back projection. Group B (n = 57) was examined on a third-generation DSCT with automated TVA and ADMIRE. Age, body diameter, attenuation of several anatomic structures, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), radiation dose (CTDIvol) and size-specific dose estimates (SSDE) were assessed. Diagnostic acceptability was rated by three readers. RESULTS: Age (p = 0.87) and body diameter (p = 0.075) did not differ significantly. Tube voltage in Group A was set automatically to 100 kV for all patients (n = 59), and to 70 kV (n = 2), 80 kV (n = 5), and 90 kV (n = 50) in Group B. Noise was reduced and CNR was increased significantly (p < 0.001). Diagnostic acceptability was rated high in both groups, with better ratings in Group B (p < 0.001). SSDE was reduced by 34 % in Group B (20.38 ± 1.63 mGy vs. 13.04 ± 1.50 mGy, p < 0.001). CONCLUSION: Combination of automated TVA and ADMIRE in neck CT using third-generation DSCT results in a substantial radiation dose reduction with low noise and increased CNR. KEY POINTS: • Third-generation DSCT provides automated tube voltage adaptation with an increment of 10 kV. • 10 kV increment optimizes scans to the patient's neck anatomy. • TVA combined with ADMIRE significantly lower radiation dose in contrast-enhanced neck CT. • TVA in combination with ADMIRE reduces noise and increases SNR and CNR. • Image analysis quoted less noise and better diagnostic acceptability in third-generation DSCT.


Assuntos
Algoritmos , Pescoço/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
13.
Eur Radiol ; 26(6): 1863-70, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26334508

RESUMO

OBJECTIVES: To compare quantitative image quality parameters in abdominal dual-energy computed tomography angiography (DE-CTA) using an advanced image-based (Mono+) reconstruction algorithm for virtual monoenergetic imaging and standard DE-CTA. METHODS: Fifty-five patients (36 men; mean age, 64.2 ± 12.7 years) who underwent abdominal DE-CTA were retrospectively included. Mono + images were reconstructed at 40, 50, 60, 70, 80, 90 and 100 keV levels and as standard linearly blended M_0.6 images (60 % 100 kV, 40 % 140 kV). The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the common hepatic (CHA), splenic (SA), superior mesenteric (SMA) and left renal arteries (LRA) were objectively measured. RESULTS: Mono+ DE-CTA series showed a statistically superior CNR for 40, 50, 60, 70 and 80 keV (P < 0.031) compared to M_0.6 images for all investigated arteries except SMA at 80 keV (P = 0.08). CNR at 40 keV revealed a mean relative increase of 287.7 % compared to linearly blended images among all assessed arteries (P < 0.001). SNR of Mono+ images was consistently significantly higher at 40, 50, 60 and 70 keV compared to M_0.6 for CHA and SA (P < 0.009). CONCLUSIONS: Compared to linearly blended images, Mono+ reconstructions at low keV levels of abdominal DE-CTA datasets significantly improve quantitative image quality. KEY POINTS: • Mono+ combines increased attenuation with reduced image noise compared to standard DE-CTA. • Mono+ shows superior contrast-to-noise ratios at low keV compared to linearly-blended images. • Contrast-to-noise ratio in monoenergetic DE-CTA peaks at 40 keV. • Mono+ reconstructions significantly improve quantitative image quality at low keV levels.


Assuntos
Cavidade Abdominal/diagnóstico por imagem , Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído
14.
J Comput Assist Tomogr ; 40(1): 80-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26466115

RESUMO

OBJECTIVE: The aim of the study was to evaluate objective and subjective image qualities of virtual monoenergetic imaging (VMI) in dual-source dual-energy computed tomography (DECT) and optimal kiloelectron-volt (keV) levels for lung cancer. METHODS: Fifty-nine lung cancer patients underwent chest DECT. Images were reconstructed as VMI series at energy levels of 40, 60, 80, and 100 keV and standard linear blending (M_0.3) for comparison. Objective and subjective image qualities were assessed. RESULTS: Lesion contrast peaked in 40-keV VMI reconstructions (2.5 ± 2.9) and 60 keV (1.9 ± 3.0), which was superior to M_0.3 (0.5 ± 2.7) for both comparisons (P < 0.001). Compared with M_0.3, subjective ratings were highest for 60-keV VMI series regarding general image quality (4.48 vs 4.52; P = 0.74) and increased for lesion demarcation (4.07 vs 4.84; P < 0.001), superior to all other VMI series (P < 0.001). Image sharpness was similar between both series. Image noise was rated superior in the 80-keV and M_0.3 series, followed by 60 keV. CONCLUSIONS: Virtual monoenergetic imaging reconstructions at 60-keV provided the best combination of subjective and objective image qualities in DECT of lung cancer.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iopamidol/análogos & derivados , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
15.
Thorac Cardiovasc Surg ; 64(3): 204-10, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25866977

RESUMO

BACKGROUND: Inferior vein graft patency after coronary artery bypass grafting (CABG) is attributed to various factors. Venous valves may limit flow, cause thrombus formation, and diminish diastolic backflow. The aim of our study was to compare clinical outcome and midterm patency rate of valvulotomized vein grafts and arterial grafts in patients undergoing CABG. METHODS: Between 2007 and 2010, valvulotomized saphenous vein segments were used to graft the right coronary artery (RCA) in 147 patients undergoing CABG with mean 2.8 ± 1 arterial and 1.5 ± 0.6 venous anastomoses. Outcome, reintervention, and reoperation were assessed after 4 ± 1.6 years. Intraoperative bypass flow rate was measured before and after valvulotomy of venous bypass grafts in 12 patients. Patency of the grafts was assessed by means of multislice computed tomography (MSCT) in 45 patients. RESULTS: A total of 102 patients underwent isolated CABG and 45 had combined procedures. In-hospital mortality was 2%. At 4 years' clinical follow-up, 95% of the patients were asymptomatic. Five patients underwent recoronary angiography because of angina pectoris. The MSCT and reangiography patency rate of all valvulotomized saphenous vein grafts was 97.1 versus 95.8% of arterial grafts 18 ± 6 months postoperatively. Intraoperative measurements showed a significant increase (+20.2 mL/min; p = 0.01) of flow in the venous bypass grafts to the RCA after valvulotomy. There were no reoperations at the latest follow-up. CONCLUSION: Patients with valvulotomized venous grafts had good clinical outcome. The one-year patency rate of those grafts is comparable to that of arterial grafts. However, long-term results and angiography studies will be needed to strengthen these findings.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Oclusão de Enxerto Vascular/cirurgia , Veia Safena/transplante , Grau de Desobstrução Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/fisiopatologia , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Veia Safena/diagnóstico por imagem , Veia Safena/fisiopatologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
16.
Acta Neuropathol ; 129(2): 297-315, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25394388

RESUMO

Mutations of the human desmin gene on chromosome 2q35 cause autosomal dominant, autosomal recessive and sporadic forms of protein aggregation myopathies and cardiomyopathies. We generated R349P desmin knock-in mice, which harbor the ortholog of the most frequently occurring human desmin missense mutation R350P. These mice develop age-dependent desmin-positive protein aggregation pathology, skeletal muscle weakness, dilated cardiomyopathy, as well as cardiac arrhythmias and conduction defects. For the first time, we report the expression level and subcellular distribution of mutant versus wild-type desmin in our mouse model as well as in skeletal muscle specimens derived from human R350P desminopathies. Furthermore, we demonstrate that the missense-mutant desmin inflicts changes of the subcellular localization and turnover of desmin itself and of direct desmin-binding partners. Our findings unveil a novel principle of pathogenesis, in which not the presence of protein aggregates, but disruption of the extrasarcomeric intermediate filament network leads to increased mechanical vulnerability of muscle fibers. These structural defects elicited at the myofiber level finally impact the entire organ and subsequently cause myopathy and cardiomyopathy.


Assuntos
Desmina/genética , Desmina/metabolismo , Músculo Esquelético/patologia , Músculo Esquelético/fisiopatologia , Miocárdio/patologia , Animais , Arritmias Cardíacas/patologia , Arritmias Cardíacas/fisiopatologia , Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Cardiomiopatia Dilatada/patologia , Cardiomiopatia Dilatada/fisiopatologia , Citoesqueleto/metabolismo , Citoesqueleto/patologia , Modelos Animais de Doenças , Escherichia coli , Técnicas de Introdução de Genes , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Camundongos Transgênicos , Debilidade Muscular/patologia , Debilidade Muscular/fisiopatologia , Distrofias Musculares/patologia , Distrofias Musculares/fisiopatologia , Mutação de Sentido Incorreto , RNA Mensageiro/metabolismo , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Células Sf9 , Spodoptera
17.
Eur Radiol ; 25(6): 1714-20, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25481639

RESUMO

OBJECTIVES: To evaluate quantitative dual-energy computed tomography (DECT) for phantomless analysis of cancellous bone mineral density (BMD) of vertebral pedicles and to assess the correlation with pedicle screw pull-out strength. METHODS: Twenty-nine thoracic and lumbar vertebrae from cadaver specimens were examined with DECT. Using dedicated post-processing software, a pedicle screw vector was mapped (R1, intrapedicular segment of the pedicle vector; R2, intermediate segment; R3, intracorporal segment; global, all segments) and BMD was calculated. To invasively evaluate pedicle stability, pedicle screws were drilled through both pedicles and left pedicle screw pull-out strength was measured. Resulting values were correlated using the paired t test and Pearson's linear correlation. RESULTS: Average pedicle screw vector BMD (R1, 0.232 g/cm(3); R2, 0.166 g/cm(3); R3, 0.173 g/cm(3); global, 0.236 g/cm(3)) showed significant differences between R1-R2 (P < 0.002) and R1-R3 (P < 0.034) segments while comparison of R2-R3 did not reach significance (P > 0.668). Average screw pull-out strength (639.2 N) showed a far stronger correlation with R1 (r = 0.80; P < 0.0001) than global BMD (r = 0.42; P = 0.025), R2 (r = 0.37; P = 0.048) and R3 (r = -0.33; P = 0.078) segments. CONCLUSIONS: Quantitative DECT allows for phantomless BMD assessment of the vertebral pedicle. BMD of the intrapedicular segment shows a significantly stronger correlation with pedicle screw pull-out strength than other segments. KEY POINTS: • Quantitative dual-energy CT enables evaluation of pedicle bone mineral density. • Intrapedicular segments show significant differences regarding bone mineral density. • Pedicle screw pull-out strength correlated strongest with R1 values. • Dual-energy CT may improve preoperative assessment before transpedicular screw fixation.


Assuntos
Densidade Óssea/fisiologia , Vértebras Lombares/fisiologia , Parafusos Pediculares , Vértebras Torácicas/fisiologia , Absorciometria de Fóton/métodos , Idoso , Fenômenos Biomecânicos , Cadáver , Estudos de Casos e Controles , Remoção de Dispositivo , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
18.
Eur Radiol ; 25(8): 2493-501, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25680727

RESUMO

OBJECTIVES: To define optimal keV settings for advanced monoenergetic (Mono+) dual-energy computed tomography (DECT) in patients with head and neck squamous cell carcinoma (SCC). METHODS: DECT data of 44 patients (34 men, mean age 55.5 ± 16.0 years) with histopathologically confirmed SCC were reconstructed as 40, 55, 70 keV Mono + and M_0.3 (30 % 80 kV) linearly blended series. Attenuation of tumour, sternocleidomastoid muscle, internal jugular vein, submandibular gland, and noise were measured. Three radiologists with >3 years of experience subjectively assessed image quality, lesion delineation, image sharpness, and noise. RESULTS: The highest lesion attenuation was shown for 40 keV series (248.1 ± 94.1 HU), followed by 55 keV (150.2 ± 55.5 HU; P = 0.001). Contrast-to-noise ratio (CNR) at 40 keV (19.09 ± 13.84) was significantly superior to all other reconstructions (55 keV, 10.25 ± 9.11; 70 keV, 7.68 ± 6.31; M_0.3, 5.49 ± 3.28; all P < 0.005). Subjective image quality was highest for 55 keV images (4.53; κ = 0.38, P = 0.003), followed by 40 keV (4.14; κ = 0.43, P < 0.001) and 70 keV reconstructions (4.06; κ = 0.32, P = 0.005), all superior (P < 0.004) to linear blending M_0.3 (3.81; κ = 0.280, P = 0.056). CONCLUSIONS: Mono + DECT at low keV levels significantly improves CNR and subjective image quality in patients with head and neck SCC, as tumour CNR peaks at 40 keV, and 55 keV images are preferred by observers. KEY POINTS: • Mono + DECT combines increased contrast with reduced image noise, unlike linearly blended images. • Mono + DECT imaging allows for superior CNR and subjective image quality. • Head and neck tumour contrast-to-noise ratio peaks at 40 keV. • 55 keV images are preferred over all other series by observers.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos
19.
Neuroradiology ; 57(6): 645-51, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25808122

RESUMO

INTRODUCTION: To investigate low-tube-voltage 80-kVp computed tomography (CT) of head and neck primary and recurrent squamous cell carcinoma (SCC) regarding objective and subjective image quality. METHODS: We retrospectively evaluated 65 patients (47 male, 18 female; mean age: 62.1 years) who underwent head and neck dual-energy CT (DECT) due to biopsy-proven primary (n = 50) or recurrent (n = 15) SCC. Eighty peak kilovoltage and standard blended 120-kVp images were compared. Attenuation and noise of malignancy and various soft tissue structures were measured. Tumor signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was rated by three reviewers using 5-point grading scales regarding overall image quality, lesion delineation, image sharpness, and image noise. Radiation dose was assessed as CT dose index volume (CTDIvol). Interobserver agreement was calculated using intraclass correlation coefficient (ICC). RESULTS: Mean tumor attenuation (153.8 Hounsfield unit (HU) vs. 97.1 HU), SNR (10.7 vs. 8.3), CNR (8.1 vs. 4.8), and subjective tumor delineation (score, 4.46 vs. 4.13) were significantly increased (all P < 0.001) with 80-kVp acquisition compared to standard blended 120-kVp images. Noise of all measured structures was increased in 80-kVp acquisition (P < 0.001). Overall interobserver agreement was good (ICC, 0.86; 95 % confidence intervals: 0.82-0.89). CTDIvol was reduced by 48.7 % with 80-kVp acquisition compared to standard DECT (4.85 ± 0.51 vs. 9.94 ± 0.81 mGy cm, P < 0.001). CONCLUSIONS: Head and neck CT with low-tube-voltage 80-kVp acquisition provides increased tumor delineation, SNR, and CNR for CT imaging of primary and recurrent SCC compared to standard 120-kVp acquisition with an accompanying significant reduction of radiation exposure.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
20.
J Comput Assist Tomogr ; 39(2): 290-4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25580679

RESUMO

Sliding-gantry computed tomography offers an interesting variety of treatment options for emergency radiology and clinical routine. The Frankfurt 2-room installation provides an interdisciplinary, multifunctional, and cost-effective concept. It is based on a magnetically sealed rail system for the permanent movement of the gantry between 2 adjacent rooms with fixed-mounted tables. In case of emergency or intensive care patients, routine scanning can be performed in room 1 until computed tomography diagnosis is required in room 2 and can then be continued in room 1 again. Moreover, this concept allows the simultaneous handling of 2 emergency patients.


Assuntos
Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA