Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 200(6): W628-34, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23701094

RESUMO

OBJECTIVE: The purpose of this study was to determine the effectiveness of a radiation dose reduction strategy for CT angiography by the combination of higher iodine delivery rate and automated tube potential selection with adjusted reference values for tube current-exposure time product, as well as to measure the impact of this approach on image quality. SUBJECTS AND METHODS: One hundred consecutive patients underwent high-pitch CT angiography of the thorax and abdomen using either 90 mL of iomeprol 300 (n = 44, protocol A) or 90 mL of iomeprol 400 (n = 56, protocol B) at the same flow rate. Automated tube potential selection was used with reference tube current-time products of 330 mAs and 250 mAs for protocols A and B, respectively. Twenty vascular segments were analyzed for attenuation and image noise by two readers. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for all segments. The dose-length product (DLP) was documented to calculate effective dose and was compared between protocols both globally and for body mass index (BMI) subgroups. RESULTS: There were no differences in sex, height, weight, or BMI between both groups. Images from patients scanned with protocol B showed higher levels of image noise but also higher signal in all vascular segments. As a result, there were no differences in SNR between both groups. Conversely, CNR was significantly higher for almost all vascular segments in the group scanned using protocol B. Furthermore, DLP was significantly lower when protocol B was used, particularly in patients with a BMI of less than 30. CONCLUSION: In CT angiography, a combination of higher iodine delivery rate and automated tube potential selection with adjusted reference values for the tube current-time product allows reductions in radiation dose by approximately 30% without compromising image quality.


Assuntos
Angiografia/métodos , Aortografia/métodos , Meios de Contraste/administração & dosagem , Artéria Ilíaca/diagnóstico por imagem , Iopamidol/análogos & derivados , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Feminino , Humanos , Iopamidol/administração & dosagem , Masculino , Estudos Prospectivos , Razão Sinal-Ruído
2.
Radiology ; 263(3): 917-26, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22623699

RESUMO

PURPOSE: To assess the feasibility and diagnostic performance of time-resolved computed tomographic (CT) angiography in the detection and classification of endoleaks after endovascular aortic aneurysm repair (EVAR) in high-risk patients. MATERIALS AND METHODS: The study was approved by our ethics committee. Written informed consent was obtained from all participating patients. Fifty-four patients (42 male and 12 female patients; mean age, 70.9 years ± 9.3 [standard deviation]) with either thoracic (n = 8) or abdominal (n = 46) aortic aneurysms treated with a stent-graft were prospectively included. The patients were examined with a time-resolved CT angiographic protocol consisting of 12 low-dose phases (80 kVp; 120 mAs [effective]; scan range, 27 cm), with 60 mL of iomeprol. Patients with abdominal aneurysm repair also underwent contrast material-enhanced (CE) ultrasonography (US). The time delay between contrast enhancement within the stent lumen and the endoleak was measured. Effective radiation dose was calculated from the scanner protocols. Measures of diagnostic performance for the detection of endoleaks were calculated for time-resolved CT angiography, with CE US serving as the reference standard. RESULTS: All time-resolved CT angiographic data sets were diagnostic. Mean effective radiation dose was 14.6 mSv. Four thoracic and 19 abdominal endoleaks were identified by using time-resolved CT angiography. Seventeen of 19 abdominal endoleaks were confirmed with CE US. This rate resulted in a sensitivity of 94%, a specificity of 93%, a positive predictive value of 89%, and a negative predictive value of 96% for time-resolved CT angiography after abdominal EVAR. Type I endoleaks showed significantly earlier mean peak contrast enhancement (0.28 second ± 0.83) compared with that for type II endoleaks (9.17 seconds ± 3.59, P < .0001). CONCLUSION: Time-resolved CT angiography with 12 low-dose phases is feasible for patients after thoracic and abdominal EVAR. The protocol approximates the radiation dose of standard triphasic protocols. Its dynamic information differentiates types of endoleaks and shows high diagnostic performance.


Assuntos
Angiografia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/terapia , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Endoleak/classificação , Estudos de Viabilidade , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Fosfolipídeos , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Hexafluoreto de Enxofre , Fatores de Tempo
3.
Eur Radiol ; 21(7): 1424-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21249370

RESUMO

OBJECTIVE: The aim of the study was to assess the performance and diagnostic value of a dual energy CT approach to reduce metal artefacts in subjects with metallic implants. METHODS: 31 patients were examined in the area of their metallic implants using a dual energy CT protocol (filtered 140 kVp and 100 kVp spectrum, tube current relation: 3:1). Specific post-processing was applied to generate energies of standard 120 and 140 kVp spectra as well as a filtered 140 kVp spectrum with mean photon energies of 64, 69 and 88 keV, respectively, and an optimized hard spectrum of 95-150 keV. Image quality and diagnostic value were subjectively and objectively determined. RESULTS: Image quality was rated superior to the standard image in 29/31 high energy reconstructions; the diagnostic value was rated superior in 27 patients. Image quality and diagnostic value scores improved significantly from 3.5 to 2.1 and from 3.6 to 1.9, respectively. In several exams decisive diagnostic features were only discernible in the high energy reconstructions. The density of the artefacts decreased from -882 to -341 HU. CONCLUSIONS: Dual Energy CT with specific postprocessing can reduce metal artefacts and may significantly enhance diagnostic value in the evaluation of metallic implants.


Assuntos
Artefatos , Metais , Próteses e Implantes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade
4.
Eur Radiol ; 20(12): 2876-81, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20589380

RESUMO

OBJECTIVE: The aim of this study was to test the feasibility of time-resolved computed tomography angiography (TR-CTA) for use in the lower leg. METHODS: Fifty-nine patients with suspected peripheral arterial occlusive disease were examined with a standard CTA (S-CTA) of the lower run-off and with an additional TR-CTA of the calves (12 phases; 2.5 s/phase, 80 kV, 120 mAs, volume of contrast medium 50 mL, flow rate 5.0 mL/s). For seven lower-leg artery segments, arterial contrast and the presence of venous overlay were tested for S-CTA and TR-CTA. Stenoses were classified on a three-point scale separately for S-CTA and TR-CTA, and diagnostic confidence for stenosis assessment was evaluated for both datasets. Contrast arrival times and HU values were evaluated in patients with asymmetric proximal stenoses. RESULTS: TR-CTA resulted in significantly higher contrast enhancement (P < 0.0001) and less venous overlay as compared to S-CTA (P < 0.05). Diagnostic confidence for stenosis rating was significantly higher in TR-CTA (P < 0.0001). Asymmetric proximal stenoses lead to significantly delayed and diminished contrast enhancement on the stenotic side. CONCLUSION: TR-CTA of the calves is feasible and provides higher enhancement and higher diagnostic confidence as compared to monophasic CTA of the lower legs.


Assuntos
Angiografia/métodos , Extremidade Inferior/anatomia & histologia , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Eur Radiol ; 20(6): 1331-6, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20033181

RESUMO

OBJECTIVE: To determine the practicability and potential dose saving of an imaging algorithm incorporating a pulsing scheme applying systolic data acquisition at heart rates >75 beats per minute (bpm). METHODS: Patients clinically referred for coronary computed tomography angiography (CTA) underwent cardiac CTA using either a diastolic pulsing window (30-70%) or a narrow systolic pulsing window (150 ms at 300 ms). Independent investigators retrospectively determined image quality (1, excellent, to 5, unreadable) and derived effective radiation exposure. RESULTS: Among all 101 subjects (62 +/- 2 years, 59% male) the predicted decrease in the best reconstruction interval for diastolic phases was 12 ms per 1 bpm [95% confidence interval (CI): -13.5 to -11.2] and -1.9 ms for systolic phases (95% CI: -3.2 to -0.62, p = 0.004), independent of age, gender and body mass index (BMI). The systolic pulsing strategy in 47 subjects (23 subjects >75 bpm) resulted in significantly lower radiation exposure (4.97 +/- 2.3 vs 9.38 +/- 5.5 mSv, p < 0.001 for systolic versus diastolic, respectively), whereas there was no difference with respect to image quality or heart rate (p = 0.65 and p = 0.74, respectively). CONCLUSIONS: Our results suggest that a systolic window for tube current modulation in subjects with higher heart rates represents a reliable tool to ensure high image quality at significantly lower dose in patients undergoing routine cardiac CTA.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sístole
6.
Eur Radiol ; 20(5): 1168-73, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20333388

RESUMO

OBJECTIVE: To detail the principles of using model-based determination of regional myocardial blood flow (MBF) by computed tomography (CT) and demonstrate its in vivo applicability. METHODS: Dual-source CT was performed with a dynamic protocol comprising acquisition with alternating table positions in ECG-triggered end-systolic timing every second for 30 s. The results of two reconstructions were merged into one final image stack (coverage 73 mm), with low spatial frequency components from a 360 degrees reconstruction and high spatial frequency components from a dual-source cardiac partial image reconstruction. A parametric deconvolution technique was used to fit the time-attenuation curves (TAC), the maximum slope of which was used to derive MBF. RESULTS: One study participant underwent dynamic myocardial stress perfusion imaging (9.6 mSv) followed by invasive coronary angiography and measurement of fractional flow reserve as the gold standard. MBF was 159 ml/100 ml/min in the non-ischaemic anterolateral and 86 ml/100 ml/min in the inferoseptal ischaemic wall. CONCLUSION: This first evaluation indicates that mathematical modelling of voxel TACs can potentially be used to quantify differences in MBF in a clinical setting. If confirmed in feasibility studies, cardiac CT may allow for parallel assessment of morphology and haemodynamic relevance of coronary artery disease.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Doença da Artéria Coronariana/terapia , Eletrocardiografia , Feminino , Humanos , Imageamento Tridimensional , Iohexol/análogos & derivados , Doses de Radiação , Stents , Sístole
7.
Eur Radiol ; 20(12): 2882-9, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20571800

RESUMO

OBJECTIVE: To evaluate the feasibility of dual-energy CT (DECT) ventilation imaging in combination with DE perfusion mapping for a comprehensive assessment of ventilation, perfusion, morphology and structure of the pulmonary parenchyma. METHODS: Two dual-energy CT acquisitions for xenon-enhanced ventilation and iodine-enhanced perfusion mapping were performed in patients under artificial respiration. Parenchymal xenon and iodine distribution were mapped and correlated with structural or vascular abnormalities. RESULTS: In all datasets, image quality was sufficient for a comprehensive image reading of the pulmonary CTA images, lung window images and pulmonary functional parameter maps and led to expedient results in each patient. CONCLUSION: With dual-source CT systems, DECT of the lung with iodine or xenon administration is technically feasible and makes it possible to depict the regional iodine or xenon distribution representing the local perfusion and ventilation.


Assuntos
Pulmão/diagnóstico por imagem , Imagem de Perfusão/métodos , Ventilação Pulmonar , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Xenônio , Adulto , Idoso , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Eur Radiol ; 20(3): 572-83, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19789884

RESUMO

PURPOSE: The purpose of this study was to assess the influence of iodine concentration on diagnostic efficacy in multi-detector-row computed tomography (MDCT) angiography of the abdominal aorta and abdominal arteries. METHODS: IRB approval and informed consent were obtained. In this double-blind trial, patients were randomised to undergo MDCT angiography of the abdominal arteries during administration of iobitridol (350 mgI/ml) or iomeprol (400 mgI/ml). Each centre applied its own technique for delivery of contrast medium, regardless of iodine concentration. Diagnostic efficacy, image quality, visualisation of the arterial wall and arterial enhancement were evaluated. A total of 153 patients received iobitridol and 154 received iomeprol. RESULTS: The ability to reach a diagnosis was "satisfactory" to "totally satisfactory" in 152 (99.3%) and 153 (99.4%) patients respectively. Image quality was rated as being "good" to "excellent" in 94.7 and 94.8% segments respectively. Similar results were observed for image quality of arterial walls (84.3 vs. 83.2%). The mean relative changes in arterial enhancement between baseline and arterial phase images showed no statistically significant differences. CONCLUSION: This study demonstrated the non-inferiority of the 350 versus 400 mgI/ml iodine concentration, in terms of diagnostic efficacy, in abdominal MDCT angiography. It also confirmed the high robustness and reliability of this technique across multi-national practices.


Assuntos
Angiografia/métodos , Aorta Abdominal/diagnóstico por imagem , Aumento da Imagem/métodos , Iohexol/análogos & derivados , Iopamidol/análogos & derivados , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Relação Dose-Resposta a Droga , Método Duplo-Cego , Europa (Continente) , Feminino , Humanos , Iohexol/administração & dosagem , Iopamidol/administração & dosagem , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
J Vasc Interv Radiol ; 21(3): 315-21, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20097097

RESUMO

PURPOSE: To compare true and "virtual" noncontrast images derived from dual-energy CT examinations in patients after endovascular repair of aortic aneurysms. MATERIALS AND METHODS: Seventy dual-energy CT examinations were performed on a dual-source CT scanner with a single-energy noncontrast scan and a dual-energy acquisition in venous phase. True and virtual noncontrast images were compared regarding image quality, calcifications in true noncontrast images, subtraction of calcification in virtual noncontrast images, and acceptance levels by two radiologists. Presence of endoleaks was assessed on venous-phase images and on virtual or true noncontrast images. In addition, the acceptance of color-coded images, in which iodine information is colored, was assessed. Possible dose reduction of a single-phase dual-energy examination protocol was compared with a standard biphasic examination protocol. RESULTS: Twenty-four endoleaks were detected and correctly classified with both approaches. Mean image quality was rated good for virtual noncontrast images (1.97 +/- 0.99) and excellent for true noncontrast images (1.16 +/- 0.37; P< .0001). Ninety-four percent of virtual noncontrast images were rated as diagnostic, and 80% of all true noncontrast images showed calcifications within the aneurysm. Subtraction of calcification in virtual noncontrast images was classified as none (30%), minimal (40%), moderate (24%), or severe (6%). Eighty-three percent of color-coded images were rated as fully diagnostic, 11% were accepted with restrictions, and 6% were nondiagnostic. Possible dose reduction of a single-phase dual-energy protocol, compared with a standard biphasic protocol, was 44%. CONCLUSIONS: Dual-energy CT makes a reliable detection of endoleaks feasible in a single acquisition. This provides a potential dose reduction for patients who have to undergo lifelong follow-up examinations after endovascular aneurysm repair.


Assuntos
Angiografia/métodos , Angioplastia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aortografia/métodos , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
10.
Radiology ; 252(2): 433-40, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19487466

RESUMO

PURPOSE: To qualitatively and quantitatively compare virtual nonenhanced (VNE) data sets derived from dual-energy (DE) computed tomography (CT) with true nonenhanced (TNE) data sets in the same patients and to calculate potential radiation dose reductions for a dual-phase renal multidetector CT compared with a standard triple-phase protocol. MATERIALS AND METHODS: This prospective study was approved by the institutional review board; all patients provided written informed consent. Seventy one men (age range, 30-88 years) and 39 women (age range, 22-87 years) underwent preoperative DE CT that included unenhanced, DE nephrographic, and delayed phases. DE CT parameters were 80 and 140 kV, 96 mAs (effective). Collimation was 14 x 1.2 mm. CT numbers were measured in renal parenchyma and tumor, liver, aorta, and psoas muscle. Image noise was measured on TNE and VNE images. Exclusion of relevant anatomy with the 26-cm field of view detector was quantified with a five-point scale (0 = none, 4 = >75%). Image quality and noise (1 = none, 5 = severe) and acceptability for VNE and TNE images were rated. Effective radiation doses for DE CT and TNE images were calculated. Differences were tested with a Student t test for paired samples. RESULTS: Mean CT numbers (+/- standard deviation) on TNE and VNE images, respectively, for renal parenchyma were 30.8 HU +/- 4.0 and 31.6 HU +/- 7.1, P = .29; liver, 55.8 HU +/- 8.6 and 57.8 HU +/- 10.1, P = .11; aorta, 42.1 HU +/- 4.1 and 43.0 HU +/- 8.8, P = .16; psoas, 47.3 HU +/- 5.6 and 48.1 HU +/- 9.3 HU, P = .38. No exclusion of the contralateral kidney was seen in 50 patients, less than 25% was seen in 43, 25%-50% was seen in 13, and 50%-75% was seen in four. Mean image noise was 1.71 +/- 0.71 for VNE and 1.22 +/- 0.45 for TNE (P < .001); image quality was 1.70 HU +/- 0.72 for VNE and 1.15 HU +/- 0.36 for TNE (P < .0001). In all but three patients radiologists accepted VNE images as replacement for TNE images. Mean effective dose for DE CT scans of the abdomen was 5.21 mSv +/- 1.86 and that for nonenhanced scans was 4.97 mSv +/- 1.43. Mean dose reduction by omitting the TNE scan was 35.05%. CONCLUSION: In patients with renal masses, DE CT can provide high-quality VNE data sets, which are a reasonable approximation of TNE data sets. Integration of DE scanning into a renal mass protocol will lower radiation exposure by 35%.


Assuntos
Carga Corporal (Radioterapia) , Neoplasias Renais/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
11.
Eur Radiol ; 19(9): 2147-55, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19415293

RESUMO

The goal of our study was to compare a prospective triggering (PT) CT technique with retrospectively gated (RG) CT techniques in coronary computed tomographic angiograms (CCTA) with respect to image quality and radiation dose. Sixty consecutive patients were enrolled. CCTAs using the RG technique were obtained with a dual-source 64-slice CT system in 40 patients, using ECG-triggered tube current modulation, with either a broad pulsing window at 30-80% of the RR interval (group RGb, 20 patients, heart rate > 70 bpm) or a small pulsing window at 70% (group RGs, 20 patients, heart rate < 70 bpm). The other 20 patients underwent CCTA using the PT technique on a 128-slice CT system (group PT, heart rate < 70 bpm). All images were evaluated by two observers for quality on a three-point scale, with 1 being excellent and 3 being insufficient. The effective radiation dose was calculated for each patient. The average image quality score was 1.5 +/- 0.6 for PT, 1.35 +/- 0.5 for RGs and 1.65 +/- 0.5 for RGb. The mean effective dose for RGb was 9 +/- 4 mSv, for RGs 7 +/- 3 mSv and for PT 3 +/- 1 mSv. This represents a 57% dose reduction for PT compared with RGs and a 67% dose reduction for PT compared with RGb. In conclusion, in selected patients CCTA with the PT technique offers adequate image quality with a significantly lower radiation dose compared with CCTA using RG techniques.


Assuntos
Carga Corporal (Radioterapia) , Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
12.
AJR Am J Roentgenol ; 193(1): 144-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19542406

RESUMO

OBJECTIVE: The purpose of this study was to assess the feasibility and diagnostic value of dual-energy CT iodine mapping at pulmonary CT angiography. SUBJECTS AND METHODS: Ninety-three patients underwent CT angiography with the dual-energy technique on a dual-source CT scanner. Postprocessing was used to map iodine in the lung parenchyma on the basis of its spectral behavior, and image quality was assessed by two readers. Iodine distribution patterns were rated as homogeneous, patchy, or circumscribed defects. Conventional CT angiographic images reconstructed from the same data sets were reviewed for the presence and localization of pulmonary embolism, whether embolic occlusion was partial or complete, and the presence of changes in the lung parenchyma. Dual-energy perfusion findings were correlated with the CT angiographic and lung-window CT findings in per-patient and per-segment analyses. RESULTS: Iodine distribution was homogeneous in 49 patients, of whom CT angiography showed no pulmonary embolism in 46 patients and nonocclusive pulmonary emboli in three patients. Images of 29 patients showed a patchy pattern; 24 of these patients had no pulmonary embolism, and five had nonocclusive pulmonary emboli with solely nonocclusive intravascular clots. Images of 15 patients showed segmental or subsegmental defects; four of these patients had evidence of pulmonary embolism, and 11 had occlusive pulmonary emboli with at least one occlusive clot in the pulmonary vasculature. CONCLUSION: Dual-energy CT is reliable in the detection of defects in pulmonary parenchymal iodine distribution that correspond to embolic vessel occlusion.


Assuntos
Iodo/farmacocinética , Pulmão/diagnóstico por imagem , Pulmão/metabolismo , Embolia Pulmonar/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Meios de Contraste/farmacocinética , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
13.
Invest Radiol ; 43(2): 112-9, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18197063

RESUMO

OBJECTIVE: The purpose of this study is to assess the accuracy of dual energy CT (DECT) in the characterization of renal and ureteral stones. MATERIAL AND METHODS: Twenty-four renal calculi of known variable composition were scanned on a dual-source CT scanner (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany) in dual energy (DECT) mode. Scan parameters for DECT were: tube potentials, 80 and 140 kV; tube current, 342 and 76 mA.s; collimation, 14 x 1.2 mm2. Dual energy properties of calculi were used to differentiate between uric acid (UA) and other calculi. Differentiation was based on a 3-material decomposition implemented in the dual energy software (Syngo VA 11; Siemens Medical Solutions). Color coding was used to display different types of stones and their DECT properties were characterized with density measurements at both photon energies. Subsequently, 20 consecutive patients with known or suspected uroliths were scanned using identical scan parameters. Stone size and material were assessed in DECT and compared with the chemical analyses of stones after mechanical extraction. RESULTS: With DECT characterization, differentiation of UA from other calculi was possible. Additionally, differentiation between cystine and struvite stones was shown to be feasible in vitro. In the patient cohort, DECT correctly characterized 4 UA calculi, 4 mixed, multiple calcified, and 1 cystine stone. The calculi were displayed in specific colors, ie, UA stones in red and calcified stones in blue. CONCLUSION: With dual energy CT techniques, the UA, cystine, struvite, and mixed renal calculi can be differentiated from other types of stones in vitro and in vivo. This is of clinical relevance as UA uroliths may be treated pharmacologically rather than with surgical extraction or extracorporal shockwave lithotripsy.


Assuntos
Tomografia Computadorizada de Emissão , Ácido Úrico , Cálculos Urinários/diagnóstico , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Ureteroscopia , Cálculos Urinários/patologia
14.
Acad Radiol ; 15(1): 49-57, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18078906

RESUMO

RATIONALE AND OBJECTIVES: Our aim was to evaluate the correlation of test bolus (TB) curve parameters with main bolus (MB) contrast density for cardiac 16-slice computed tomography, and to correlate observed enhancement with patient body weight. MATERIALS AND METHODS: Sixty patients with known or suspected coronary artery disease were included in a prospective double-blind study. Contrast material containing 300 mg iodine/mL (Iomeprol 300; Imeron 300, Bracco Imaging SpA, Milan, Italy) and 400 mg iodine/mL (Iomeprol 400; Imeron 400) was injected at a rate of 1 g of iodine/second. Contrast densities (Hounsfield units) of the MB were determined in the left cardiac system. The peak density (PD) of maximum attenuation and the area under the curve (AUC) of the TB curve were calculated for each patient. The dependency of MB contrast attenuation on these parameters and on patient body weight was evaluated. RESULTS: Positive correlations (r = 0.52 and r = 0.56, respectively; P < .0001) were obtained between the PD and AUC of the TB curve with the mean density of the MB. Stronger correlations (r = 0.63 and r = 0.64, respectively; P < .0001) between PD and AUC of the TB curve and MB attenuation were found when patient body weight was included in the analysis. CONCLUSIONS: Strong correlation of the PD and AUC of the TB curve with the mean density of the MB is observed when patient body weight is considered. Contrast injection protocols may be optimized, and variations of MB contrast density in the left ventricle and main coronary arteries reduced, by taking these TB parameters and the weight of the patient into account.


Assuntos
Peso Corporal , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Meios de Contraste/farmacocinética , Método Duplo-Cego , Feminino , Humanos , Injeções , Masculino , Pessoa de Meia-Idade
15.
Invest Radiol ; 42(10): 684-91, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17984765

RESUMO

PURPOSE: The aim of this study was to evaluate the diagnostic accuracy of dual-source computed tomography (DSCT) with reference to invasive coronary angiography in the diagnosis of coronary artery disease (CAD) on a per-patient as well as on a per-segment basis. MATERIALS AND METHODS: Thirty-five patients with known or suspected CAD underwent both DSCT (Somatom Definition, Siemens Medical Solutions) and quantitative x-ray coronary angiography (QCA). Parameters of CT acquisition were gantry rotation time 0.330 seconds (ie, temporal resolution 83 milliseconds), tube voltage 120 kV, tube current 560 mA with ECG-triggered tube current modulation and full current at 70% of the cardiac cycle for heart rates below 70 beats per minute or full current between 30% and 80% for higher and arrhythmic heart rates. The pitch was also adapted to the heart rate, ranging from 0.2 to 0.43. Volume and flow rate of contrast material (Ultravist 370, Schering AG) were adapted to the patient's body weight. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of DSCT in the detection or exclusion of significant CAD (ie, stenoses >50%) were evaluated on a per-patient and per-segment basis. RESULTS: All 35 CT angiograms were of diagnostic image quality. QCA demonstrated significant CAD in 48% (n = 17) and nonsignificant disease or normal coronary angiograms in 52% (n = 18) of the patients. Sensitivity, specificity, PPV, and NPV of DSCT on a per-patient basis were 100%, 89%, 89%, and 100%, respectively. On a per-segment basis, 473 of 481 coronary artery segments were assessable (98%). QCA demonstrated stenoses >50% in 32 segments (7%), and no disease or nonsignificant disease in 433 segments (93%). For the detection of stenoses >50% on a per-segment basis, DSCT showed a sensitivity, specificity, PPV, and NPV of 88%, 98%, 78%, and 99%, respectively. CONCLUSIONS: The comparison of coronary DSCT with QCA shows a very robust image quality and a high diagnostic accuracy in a patient-based as well as a per-segment analysis. Maximal sensitivity and NPV in the per-patient analysis show the strength of the technique in ruling out significant CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Tomografia Computadorizada de Emissão/instrumentação , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão/métodos
16.
AJR Am J Roentgenol ; 188(1): 76-82, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17179348

RESUMO

OBJECTIVE: The most important differential diagnoses of acute chest pain include myocardial infarction, aortic dissection, and pulmonary embolism. The purpose of this study was to evaluate the diagnostic value of an ECG-gated 64-MDCT angiography protocol for simultaneous assessment of the pulmonary arteries, coronary arteries, and aorta within a single breath-hold. SUBJECTS AND METHODS: In 55 patients with acute chest pain, ECG-gated CT angiography was performed with a CT system in which 64 slices per gantry rotation were acquired. Density measurement and visual assessment of motion artifacts were performed to evaluate image quality. CT findings were correlated with results of laboratory tests and clinical follow-up. For 20 patients, two independent blinded reviewers compared findings on CT angiography with those on X-ray coronary angiography. RESULTS: Adequate contrast enhancement of the pulmonary vessels, coronary arteries, and aorta was achieved in all cases. Regarding image quality of the coronary arteries, there was minor blurring in seven patients, and in one examination the images did not provide enough information for diagnosis. The average image quality rating was 1.2 on a scale in which 1 indicated no artifacts; 2, minor motion artifacts; and 3, image insufficient for diagnosis. The cause of chest pain was correctly identified with MDCT in 37 patients. The diagnoses included pulmonary embolism (n = 10), coronary stenosis (n = 9), and aortic dissection (n = 1). In four patients, additional diagnoses were found with other examinations. CONCLUSION: With current techniques, ECG-gated CT angiography of the entire chest has very good image quality. The protocol proved helpful in the differential diagnosis of acute chest pain.


Assuntos
Angiografia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Dor no Peito/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Idoso , Aortografia/métodos , Artefatos , Dor no Peito/etiologia , Angiografia Coronária/métodos , Diagnóstico Diferencial , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Infarto do Miocárdio/complicações , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
17.
J Am Coll Cardiol ; 46(1): 147-54, 2005 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-15992649

RESUMO

OBJECTIVES: The aim of the present study was to determine the diagnostic accuracy of 64-slice computed tomography (CT) to identify and quantify atherosclerotic coronary lesions in comparison with catheter-based angiography and intravascular ultrasound (IVUS). BACKGROUND: Currently, the ability of multislice CT to quantify the degree of coronary artery stenosis and dimensions of coronary plaques has not been evaluated. METHODS: We included 59 patients scheduled for coronary angiography due to stable angina pectoris. A contrast-enhanced 64-slice CT (Senation 64, Siemens Medical Solutions, Forchheim, Germany) was performed before the invasive angiogram. In a subset of 18 patients, IVUS of 32 vessels was part of the catheterization procedure. RESULTS: In 55 of 59 patients, 64-slice CT enabled the visualization of the entire coronary tree with diagnostic image quality (American Heart Association 15-segment model). The overall correlation between the degree of stenosis detected by quantitative coronary angiography compared with 64-slice CT was r = 0.54. Sensitivity for the detection of stenosis <50%, stenosis >50%, and stenosis >75% was 79%, 73%, and 80%, respectively, and specificity was 97%. In comparison with IVUS, 46 of 55 (84%) lesions were identified correctly. The mean plaque areas and the percentage of vessel obstruction measured by IVUS and 64-slice CT were 8.1 mm2 versus 7.3 mm2 (p < 0.03, r = 0.73) and 50.4% versus 41.1% (p < 0.001, r = 0.61), respectively. CONCLUSIONS: Contrast-enhanced 64-slice CT is a clinically robust modality that allows the identification of proximal coronary lesions with excellent accuracy. Measurements of plaque and lumen areas derived by CT correlated well with IVUS. A major limitation is the insufficient ability of CT to exactly quantify the degree of stenosis.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia de Intervenção , Idoso , Estudos de Viabilidade , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
18.
Am J Cardiol ; 98(6A): 5K-13K, 2006 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-16949375

RESUMO

Contrast-induced nephropathy (CIN), usually defined as an increase in serum creatinine of 0.5 mg/dL (44.2 mumol/L), or a 25% increase from the baseline value 48 hours after the procedure, is a common and potentially serious complication of the use of iodinated contrast media in patients at risk of acute renal injury. It is an important cause of hospital-acquired renal failure, responsible for approximately 11% of cases. CIN may be difficult to distinguish from cholesterol embolization, another cause of postprocedure renal impairment. The reported incidence of CIN varies depending on the patient population studied. The impact of postprocedural renal impairment on clinical outcomes has been evaluated most extensively in patients undergoing percutaneous coronary intervention. CIN is associated with increased mortality both in hospital and at 1 year. A higher incidence of in-hospital and late cardiovascular events, as well as longer hospital stays, has been reported in patients developing CIN. In a small proportion of patients, CIN is severe enough to require dialysis, and these patients have a particularly poor prognosis. Many of the risk markers for CIN are also predictive of a worse prognosis.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/epidemiologia , Meios de Contraste/efeitos adversos , Injúria Renal Aguda/terapia , Creatinina/sangue , Diagnóstico Diferencial , Embolia de Colesterol/diagnóstico , Humanos , Incidência , Prognóstico , Diálise Renal , Fatores de Risco
19.
Am J Cardiol ; 98(6A): 14K-20K, 2006 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-16949376

RESUMO

Contrast-induced nephropathy (CIN) is the third leading cause of acute kidney injury in hospitalized patients and is associated with significant patient morbidity. The pathogenesis of CIN is complex and not fully understood, but iodinated contrast agents induce intense and prolonged vasoconstriction at the corticomedullary junction of the kidney. Moreover, high-osmolar dyes directly impair the autoregulatory capacity of the kidney through a loss of nitric oxide production. These effects, coupled with direct tubular toxicity of contrast media, lead to overt acute tubular necrosis and the syndrome of CIN.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/fisiopatologia , Meios de Contraste/efeitos adversos , Adenosina/sangue , Biomarcadores/urina , Conferências de Consenso como Assunto , Embolia de Colesterol/fisiopatologia , Endotelinas/sangue , Humanos , Túbulos Renais/efeitos dos fármacos , Túbulos Renais/fisiopatologia , Óxido Nítrico/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Circulação Renal/efeitos dos fármacos , Circulação Renal/fisiologia , Reperfusão , Sódio/urina , Vasoconstrição/efeitos dos fármacos , Vasoconstrição/fisiologia
20.
Am J Cardiol ; 98(6A): 21K-26K, 2006 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-16949377

RESUMO

Renal impairment at baseline (estimated glomerular filtration rate [eGFR] <60 mL/min/1.73 m(2)) is the most important risk marker to predict the risk of contrast-induced nephropathy (CIN) in patients receiving iodinated contrast media. Hence, it is important to assess renal function before administration of contrast medium to ensure that appropriate steps are taken to reduce the risk. Serum creatinine alone does not provide a reliable measure of renal function, hence the National Kidney Foundation Kidney Disease Outcome Quality Initiative (K/DOQI) recommends that clinicians should use an eGFR calculated from the serum creatinine as an index of renal function. The CIN Consensus Working Panel agreed that eGFR should be determined before contrast administration, using the abbreviated Modification of Diet in Renal Disease (MDRD) formula, recommended by K/DOQI as the preferred equation for the calculation of eGFR in adults. Where a serum creatinine measurement or eGFR is not available, a simple survey or questionnaire can be used before contrast agent administration to identify patients at higher risk for CIN compared with the general population. In emergency situations, where the benefit of very early imaging outweighs the risk of waiting, the CIN Consensus Working Panel agreed that the procedure can be performed without assessment of renal function.


Assuntos
Meios de Contraste/efeitos adversos , Programas de Rastreamento/métodos , Insuficiência Renal/diagnóstico , Insuficiência Renal/prevenção & controle , Conferências de Consenso como Assunto , Creatinina/sangue , Emergências , Taxa de Filtração Glomerular , Humanos , Guias de Prática Clínica como Assunto , Insuficiência Renal/induzido quimicamente , Medição de Risco , Fatores de Risco , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA