Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Curr Urol Rep ; 22(1): 2, 2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33403502

RESUMO

PURPOSE OF REVIEW: Pheochromocytoma and paraganglioma (PPGLs) are neuroendocrine tumors with diverse clinical presentations. PPGLs can be sporadic but often are associated with various syndromes, which can have variable clinical presentations. A thorough workup is therefore critical for staging, treatment, and follow-up. Imaging is an essential part of the workup and diagnosis of PPGLs. RECENT FINDINGS: Improvements in cross-sectional imaging with radionuclides have increased specificity and sensitivity for identifying and treating PPGLs. Furthermore, a variety of targets on PPGLs has allowed for optimal imaging with radionuclides that can be used for staging and treatment. Currently, radionuclides are being evaluated for staging and treatment of PPGLs. Developing novel radionuclides that can identify disease sites and target them simultaneously provides a potential for improving survival and outcomes in patients with PPGLs. Given the clinical diversity among PPGLs, expanding the therapeutic arsenal against locally advanced or metastatic PPGLs can allow clinicians to evaluate and treat PPGLs thoroughly.


Assuntos
Paraganglioma , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Neoplasias das Glândulas Suprarrenais/diagnóstico , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/terapia , Humanos , Imageamento por Ressonância Magnética , Paraganglioma/diagnóstico , Paraganglioma/diagnóstico por imagem , Paraganglioma/terapia , Feocromocitoma/diagnóstico , Feocromocitoma/diagnóstico por imagem , Feocromocitoma/terapia , Cintilografia , Compostos Radiofarmacêuticos/uso terapêutico , Síndrome , Tomografia Computadorizada por Raios X
2.
Radiology ; 293(1): 203-211, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31407971

RESUMO

Existing surveys of radiopharmaceutical doses for U.S. nuclear medicine laboratories are of limited scope and size. Dose data are important because they can be used to benchmark individual laboratories, understand geographic variations in practice, and provide source data for societal guidelines and appropriateness criteria. Diagnostic reference levels (DRLs) and achievable administered activities (AAAs) for 13 noncardiac adult gamma camera and PET/CT examinations were derived retrospectively from American College of Radiology accreditation data (January 1, 2015, to December 31, 2017). The calculated DRL and AAA are consistent with previously published surveys. The distributions of radiopharmaceutical doses across facilities are in general consistent but show variation within a particular examination. Analysis of dose distribution suggests this variation results from differences in clinical protocols, educational gaps, and/or equipment factors. The AAA for the surveyed facilities exceeds dose ranges proposed in societal practice guidelines for several common nuclear medicine studies. Compared with similar surveys from Europe and Japan, geographic variation is observed, with some doses greater and others lower than used in the United States. Overall, radiopharmaceutical dose variation within the United States and internationally, and deviation from societal guidelines, imply that these dose-related benchmarks may be used to further standardize and improve clinical practice.


Assuntos
Câmaras gama/estatística & dados numéricos , Medicina Nuclear/estatística & dados numéricos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Compostos Radiofarmacêuticos , Adulto , Humanos , Valores de Referência , Estudos Retrospectivos , Estados Unidos
3.
J Am Coll Radiol ; 16(2): 236-239, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30245216

RESUMO

The ACR Dose Index Registry (DIR) provides a new source of clinical radiation exposure data that has not been used previously to establish or update the relative radiation level (RRL) values in the ACR Appropriateness Criteria (AC). The results of a recent review of DIR data for 10 common CT examinations were compared with current ACR AC RRL values for the same procedures. The AC RRL values were previously determined by consensus of members of the AC Radiation Exposure Subcommittee based on reference radiation dose values from the literature (when available) and anecdotal information from individual members' clinical practices and experiences. For 7 of the 10 examination types reviewed, DIR data agreed with existing RRL values. For 3 of 10 examination types, DIR data reflected lower dose values than currently rated in the AC. The Radiation Exposure Subcommittee will revise these RRL assignments in a forthcoming update to the AC (in October 2018) and will continue to monitor the DIR and associated reviews and analyses to refine RRL assignments for additional examination types. Given recent attention and efforts to reduce radiation exposure in CT and other imaging modalities, it is likely that other examination types will require revision of RRL assignments once information from the DIR database is considered.


Assuntos
Diagnóstico por Imagem/normas , Monitoramento de Radiação/normas , Sistema de Registros , Sociedades Médicas , Adulto , Humanos , Doses de Radiação , Exposição à Radiação/normas , Estados Unidos
4.
J Am Coll Radiol ; 13(6): 688-95, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27131619

RESUMO

PURPOSE: The aim of this study was to glean from accreditation surveys of US nuclear medicine facilities the in-practice radiopharmaceutical diagnostic reference levels (DRLs) and achievable administered activities (AAAs) for adult gamma camera myocardial perfusion imaging (MPI). METHODS: Data were collected from the ACR Nuclear Medicine Accreditation Program during one three-year accreditation cycle from May 1, 2012, to April 30, 2015. Data elements included radiopharmaceutical, administered activity, examination protocol, interpreting physician specialty, practice type, and facility annual examination volume. Facility demographics, DRLs, and AAAs were tabulated for analysis. RESULTS: The calculated DRLs and AAAs are consistent with previously published surveys, and they adhere to national societal guidelines. Facilities seeking ACR accreditation are nearly evenly split between hospital based with multiple gamma cameras and office based with single gamma cameras. The majority of facilities use single-day, low-dosage/high-dosage (99m)Tc-based protocols; a small minority use (201)TlCl protocols. Administered activities show a consistency across facilities, likely reflecting adoption of standard MPI protocols. CONCLUSIONS: This practice-based analysis provides DRL and AAA benchmarks that nuclear medicine facilities may use to refine gamma camera MPI protocols. In general, the protocols submitted for ACR accreditation are consistent with national societal guidelines. The results suggest that there may be opportunities to further reduce patient radiation exposure by using modified examination protocols and newer gamma camera software and hardware technologies.


Assuntos
Câmaras gama , Imagem de Perfusão do Miocárdio/normas , Padrões de Prática Médica/estatística & dados numéricos , Acreditação/normas , Adulto , Humanos , Medicina Nuclear , Exposição à Radiação , Compostos Radiofarmacêuticos/administração & dosagem , Valores de Referência , Sociedades Médicas , Software , Conselhos de Especialidade Profissional , Inquéritos e Questionários , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA