Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 332
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38795719

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Eur Heart J ; 45(11): 922-936, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38243773

RESUMO

BACKGROUND AND AIMS: Risk stratification for mitral valve transcatheter edge-to-edge repair (M-TEER) is paramount in the decision-making process to appropriately select patients with severe secondary mitral regurgitation (SMR). This study sought to develop and validate an artificial intelligence-derived risk score (EuroSMR score) to predict 1-year outcomes (survival or survival + clinical improvement) in patients with SMR undergoing M-TEER. METHODS: An artificial intelligence-derived risk score was developed from the EuroSMR cohort (4172 and 428 patients treated with M-TEER in the derivation and validation cohorts, respectively). The EuroSMR score was validated and compared with established risk models. RESULTS: The EuroSMR risk score, which is based on 18 clinical, echocardiographic, laboratory, and medication parameters, allowed for an improved discrimination of surviving and non-surviving patients (hazard ratio 4.3, 95% confidence interval 3.7-5.0; P < .001), and outperformed established risk scores in the validation cohort. Prediction for 1-year mortality (area under the curve: 0.789, 95% confidence interval 0.737-0.842) ranged from <5% to >70%, including the identification of an extreme-risk population (2.6% of the entire cohort), which had a very high probability for not surviving beyond 1 year (hazard ratio 6.5, 95% confidence interval 3.0-14; P < .001). The top 5% of patients with the highest EuroSMR risk scores showed event rates of 72.7% for mortality and 83.2% for mortality or lack of clinical improvement at 1-year follow-up. CONCLUSIONS: The EuroSMR risk score may allow for improved prognostication in heart failure patients with severe SMR, who are considered for a M-TEER procedure. The score is expected to facilitate the shared decision-making process with heart team members and patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Inteligência Artificial , Coração , Ecocardiografia , Fatores de Risco , Resultado do Tratamento
3.
J Neurophysiol ; 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39140591

RESUMO

Murine organotypic brain slice cultures have been widely used in neuroscientific research and are offering the opportunity to study neuronal function under normal and disease conditions. Despite the broad application, the mechanisms governing the maturation of immature cortical circuits in vitro are not well understood. In this study, we present a detailed investigation into the development of the neocortex in vitro. Utilizing a holistic approach, we studied organotypic whole-hemisphere brain slice cultures from postnatal mice and tracked the development of the somatosensory area over a five-week period. Our analysis revealed the maturation of passive and active intrinsic properties of pyramidal cells together with their morphology, closely resembling in vivo development. Detailed Multi-electrode array (MEA) electrophysiological assessments and RNA expression profiling demonstrated stable network properties by two weeks in culture, followed by the transition of spontaneous activity toward more complex patterns including high-frequency oscillations. However, weeks 4 and 5 exhibited increased variability and initial signs of neuronal loss, highlighting the importance of considering developmental stages in experimental design. This comprehensive characterization is vital for understanding the temporal dynamics of the neocortical development in vitro, with implications for neuroscientific research methodologies, particularly in the investigation of diseases such as epilepsy and other neurodevelopmental disorders.

4.
Proc Natl Acad Sci U S A ; 118(27)2021 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-34183414

RESUMO

Demyelination is a key pathogenic feature of multiple sclerosis (MS). Here, we evaluated the astrocyte contribution to myelin loss and focused on the neurotrophin receptor TrkB, whose up-regulation on the astrocyte finely demarcated chronic demyelinated areas in MS and was paralleled by neurotrophin loss. Mice lacking astrocyte TrkB were resistant to demyelination induced by autoimmune or toxic insults, demonstrating that TrkB signaling in astrocytes fostered oligodendrocyte damage. In vitro and ex vivo approaches highlighted that astrocyte TrkB supported scar formation and glia proliferation even in the absence of neurotrophin binding, indicating TrkB transactivation in response to inflammatory or toxic mediators. Notably, our neuropathological studies demonstrated copper dysregulation in MS and model lesions and TrkB-dependent expression of copper transporter (CTR1) on glia cells during neuroinflammation. In vitro experiments evidenced that TrkB was critical for the generation of glial intracellular calcium flux and CTR1 up-regulation induced by stimuli distinct from neurotrophins. These events led to copper uptake and release by the astrocyte, and in turn resulted in oligodendrocyte loss. Collectively, these data demonstrate a pathogenic demyelination mechanism via the astrocyte release of copper and open up the possibility of restoring copper homeostasis in the white matter as a therapeutic target in MS.


Assuntos
Astrócitos/metabolismo , Astrócitos/patologia , Cobre/metabolismo , Esclerose Múltipla/metabolismo , Animais , Transporte Biológico , Doença Crônica , Cicatriz/patologia , Cuprizona , Modelos Animais de Doenças , Encefalomielite Autoimune Experimental , Humanos , Inflamação/patologia , Ligantes , Proteínas de Membrana Transportadoras/metabolismo , Camundongos Knockout , Bainha de Mielina/metabolismo , Fatores de Crescimento Neural/metabolismo , Receptor trkB/metabolismo , Regulação para Cima , Substância Branca/patologia
5.
Circulation ; 145(10): 724-738, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-34747186

RESUMO

BACKGROUND: No study has so far compared Amulet with the new Watchman FLX in terms of residual left atrial appendage (LAA) patency or clinical outcomes in patients undergoing percutaneous LAA closure. METHODS: In the investigator-initiated SWISS APERO trial (Comparison of Amulet Versus Watchman/FLX Device in Patients Undergoing Left Atrial Appendage Closure), patients undergoing LAA closure were randomly assigned (1:1) open label to receive Amulet or Watchman 2.5 or FLX (Watchman) across 8 European centers. The primary end point was the composite of justified crossover to a nonrandomized device during LAA closure procedure or residual LAA patency detected by cardiac computed tomography angiography (CCTA) at 45 days. The secondary end points included procedural complications, device-related thrombus, peridevice leak at transesophageal echocardiography, and clinical outcomes at 45 days. RESULTS: Between June 2018 and May 2021, 221 patients were randomly assigned to Amulet (111 [50.2%]) or Watchman (110 [49.8%]), of whom 25 (22.7%) patients included before October 2019 received Watchman 2.5, and 85 (77.3%) patients received Watchman FLX. The primary end point was assessable in 205 (92.8%) patients and occurred in 71 (67.6%) patients receiving Amulet and 70 (70.0%) patients receiving Watchman, respectively (risk ratio, 0.97 [95% CI, 0.80-1.16]; P=0.713). A single justified crossover occurred in a patient with Amulet who fulfilled LAA patency criteria at 45-day CCTA. Major procedure-related complications occurred more frequently in the Amulet group (9.0% versus 2.7%; P=0.047) because of more frequent bleeding (7.2% versus 1.8%). At 45 days, the peridevice leak rate at transesophageal echocardiography was higher with Watchman than with Amulet (27.5% versus 13.7%, P=0.020), albeit none was major (ie, >5 mm), whereas device-related thrombus was detected in 1 (0.9%) patient with Amulet and 3 (3.0%) patients with Watchman at CCTA and in 2 (2.1%) and 5 (5.5%) patients at transesophageal echocardiography, respectively. Clinical outcomes at 45 days did not differ between the groups. CONCLUSIONS: Amulet was not associated with a lower rate of the composite of crossover or residual LAA patency compared with Watchman at 45-day CCTA. Amulet, however, was associated with lower peridevice leak rates at transesophageal echocardiography, higher procedural complications, and similar clinical outcomes at 45 days compared with Watchman. The clinical relevance of CCTA-detected LAA patency requires further investigation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03399851.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia Transesofagiana/métodos , Humanos , Resultado do Tratamento
6.
Rev Cardiovasc Med ; 24(5): 128, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-39076731

RESUMO

Pharmacological treatment is the cornerstone therapy of heart failure with reduced ejection fraction (HFrEF). In addition, several percutaneous techniques have been developed to treat symptomatic patients, with specific heart failure (HF) phenotypes (e.g., valvular heart disease) that require non-pharmacological treatment. Given their prognostic relevance, it is imperative to deliver high-level patient care. This review provides a clinical overview on the available data regarding transcatheter devices in the armamentarium of contemporary interventional cardiologists, focusing on the clinical and anatomical selection criteria.

7.
Rev Cardiovasc Med ; 24(8): 221, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39076703

RESUMO

Background: The DynamX Novolimus-Eluting Coronary Bioadaptor System ( DynamX ® Bioadaptor) has uncaging elements that disengage after the resorption of the polymer coating, aiming to restore vessel function in the treated segment and to avoid long-term adverse outcomes associated with the permanent caging of the coronary artery seen with conventional stenting. Methods: This prospective, multicenter, single-arm first-in-human study enrolled 50 patients in Belgium and Italy who were treated with the DynamX Bioadaptor. Eligible patients had de novo lesions in coronary arteries measuring between 2.5 and 3.5 mm in diameter and ≤ 24 mm in length. Clinical follow-up was performed up to 36 months. This analysis includes the intention-to-treat population and is based on data available. The preclinical studies include optical coherence tomography (OCT) analyses of 5 DynamX Bioadaptors implanted in 3 mini Yucatan pigs (at 3, 12 and 24 months), and assessment of smooth muscle cell gene expression profile in 8 pigs of which each was implanted with the DynamX Bioadaptor and the Xience drug-eluting stent. To assess the gene expression profile by quantitative real-time polymerase chain reaction, animals were sacrificed at 3, 6, 9 and 12 months. Results: Target lesion failure at 36 months was 8.7% (4/46), consisting of one clinically-driven target lesion revascularization and 3 cardiac deaths (all site-reported to be unrelated to the device or procedure). There were no additional target vessel revascularization and no definite or probable scaffold thrombosis. Preclinical data confirmed late lumen enlargement (from 7.02 ± 1.31 mm 2 at baseline to 8.46 ± 1.31 mm 2 at 24 months) and identified an increased expression of contractile genes around 9 months compared to a conventional drug-eluting stent. Conclusions: The DynamX Bioadaptor demonstrated very good 36-month clinical outcomes, highlighted by the absence of target-vessel myocardial infarction and definite or probable device thrombosis, and only one target lesion revascularization up to 36 months. These data are supported by preclinical studies that showed late lumen enlargement by OCT and an increased expression of contractile genes around 9 months compared to conventional drug-eluting stents, indicating faster vessel healing. Larger clinical studies are necessary to compare outcomes against contemporary drug-eluting stents. Clinical Trial Registration: https://clinicaltrials.gov/: NCT03429894.

8.
Catheter Cardiovasc Interv ; 102(7): 1364-1375, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37698335

RESUMO

BACKGROUND: Extremely large aortic valve anatomy is one of the remaining limitations leading to exclusion of patients for transcatheter aortic valve replacement (TAVR). AIMS: The newly approved Myval 32 mm device is designed for use in aortic annulus areas up to 840 mm2 . Here we want to share the initial worldwide experience with the device. METHODS AND RESULTS: Retrospective data were collected from 10 patients with aortic stenosis and very large annular anatomy (mean area 765.5 mm2 ), who underwent implantation with 32 mm Myval transcatheter heart valve at eight centers. Valve Academic Research Consortium-2 device success was achieved in all cases. Mild paravalvular leak was observed in three patients and two patients required new pacemaker implantation. One patient experienced retroperitoneal hemorrhage caused by the contralateral 6 F sheath and required surgical revision. No device-related complications, stroke, or death from any cause occurred within the 30-day follow-up period. In a studied cohort of 2219 consecutive TAVR-screened patients from a central European site, only 0.27% of patients showed larger anatomy than covered by the 32 mm Myval device by instructions for use without off-label use of overexpansion. This rate was significantly higher for the 34 mm Evolut Pro (1.8%) and 29 mm Sapien 3 (2.1%) devices. CONCLUSIONS: The Myval 32 mm prosthesis showed promising initial results in a cohort of patients who previously had to be excluded from TAVR. It is desirable that all future TAVR systems accommodate larger anatomy to allow optimal treatment of all patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos
9.
Catheter Cardiovasc Interv ; 102(6): 1122-1131, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37794734

RESUMO

BACKGROUND: The incidence and predictors of 30-day stroke after transcatheter aortic valve replacement (TAVR) were derived from early studies investigating first-generation devices. The incidence of 6-month stroke and its related predictors are unknown. AIMS: To investigate the incidence and to identify procedural and patient-related predictors of 30-day and 6-month stroke after TAVR. METHODS: Data from 2753 consecutive patients with severe aortic stenosis undergoing TAVR were obtained from the OBSERVANT-II study, an observational, prospective, multicenter cohort study. The study endpoints were symptomatic 30-day and 6-month stroke after TAVR. RESULTS: The occurrence of a 30-day and 6-month stroke was low (1.3% and 2.4%, respectively) but with significant impact on survival. Aortic valve predilatation (odds ratio [OR]: 2.28, 95% confidence interval [CI]: 1.12-4.65, p = 0.023), diabetes (OR: 3.10, 95% CI: 1.56-6.18, p = 0.001), and left ventricle ejection fraction < 50% (OR: 2.15, 95% CI: 1.04-4.47, p = 0.04) were independent predictors of 30-day stroke, whereas diabetes (sub-distribution hazard ratio [SHR]: 2.07, 95% CI: 1.25-3.42, p = 0.004), pre-existing neurological dysfunction (SHR: 3.92, 95% CI: 1.54-10, p = 0.004), bicuspid valve (SHR: 4.75, 95% CI: 1.44-15.7, p = 0.011), and critical status (SHR: 3.05, 95% CI: 1.21-7.72, p = 0.018) were predictive of 6-month stroke. Conversely, antiplatelet therapy and anticoagulation were protective factors at both 30 days and 6 months. CONCLUSIONS: Stroke after TAVR was rare. Predilatation was the only procedural factor predictive of 30-day stroke, whereas the remaining were patient-related risk factors, suggesting appropriate risk stratification preoperatively.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Incidência , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 102(2): 310-317, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37232290

RESUMO

BACKGROUND: The relationship between high postprocedural mean gradient (ppMG) and clinical events following mitral valve transcatheter edge-to-edge repair (MV-TEER) in patients with degenerative mitral regurgitation (DMR) is still debated. AIM: The purpose of this study was to evaluate the effect of elevated ppMG after MV-TEER on clinical events in patients with DMR at 1-year follow-up. METHODS: The study included 371 patients with DMR treated with MV-TEER enrolled in the "Multi-center Italian Society of Interventional Cardiology (GISE) registry of trans-catheter treatment of mitral valve regurgitation" (GIOTTO) registry. Patients were stratified in tertiles according to ppMG. Primary endpoint was a composite of all-cause death and hospitalization due to heart failure at 1-year follow-up. RESULTS: Patients were stratified as follows: 187 with a ppMG ≤ 3 mmHg, 77 with a ppMG > 3/=4 mmHg, and 107 with a ppMG > 4 mmHg. Clinical follow-up was available in all subjects. At multivariate analysis, neither a ppMG > 4 mmHg nor a ppMG ≥ 5 mmHg were independently associated with the outcome. Notably, the risk of elevated residual MR (rMR > 2+) was significantly higher in patients belonging to the highest tertile of ppMG (p = 0.009). The association of ppMG > 4 mmHg and rMR ≥ 2+ was strongly and independently associated with adverse events (hazard ratio: 1.98; 95% confidence interval: [1.10-3.58]). CONCLUSIONS: In a real-world cohort of patients suffering DMR and treated with MV-TEER, isolated ppMG was not associated with the outcome at 1-year follow-up. A high proportion of patients showed both elevated ppMG and rMR and their combination appeared to be a strong predictor of adverse events.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
11.
Rev Cardiovasc Med ; 23(11): 358, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39076178

RESUMO

Background: The impact of nodular calcifications in left ventricular outlow tract (LVOT) and aortic annulus on the procedural outcome of transcatheter aortic valve implantation (TAVI) with new-generation devices is yet to be elucidated. Similarly, computational simulations may provide a novel insight into the biomechanical features of TAVI devices and their interaction with nodular calcifications. Methods: This retrospective single-center study included 232 patients submitted to TAVI with Evolut-R (53.4%), Portico (33.6%) and Lotus (13.0%) devices with available preoperative computed tomography (CT) angiography and evidence of nodular calcifications in aortic annulus and/or LVOT. Calcification severity was defined ≥ moderate in presence of at least two nodules or one nodule ≤ 5 mm. Three virtual simulation models of aortic root presenting a nodular calcification of increasing size were implemented. Stress distribution, stent-root contact area and paravalvular orifice area were computed. Results: At least moderate calcifications were found in 123 (53.0%) patients, with no sex differences. Among the ≥ moderate calcification group, lower device success rate was evident (87.8% vs. 95.4%; p = 0.039). Higher rates of ≥ moderate paravalvular leak (PVL) (11.4% vs. 3.7%; p = 0.028) and vascular complications (9.8% vs. 2.8%; p = 0.030) were also observed. Among the Evolut-R group, higher rates of at ≥ moderate PVL (12.1%) were observed compared to Portico (3.8%; p = 0.045) and Lotus (0.0%; p = 0.044) groups. Calcification of both annulus and LVOT (odds ratio [OR] 0.105; p = 0.023) were independent predictors of device success. On computational simulations, Portico exhibited homogeneous stress distribution by increasing calfications and overall a larger paravalvular orifice areas compared to Evolut-R and Lotus. Evolut-R showed higher values of average stress than Portico, although with a more dishomogeneous distribution leading to greater paravalvular orifice areas by severe calcifications. Lotus showed overall small paravalvular orifice areas, with no significant increase across the three models. Conclusions: At least moderate nodular calcifications in the annulus/LVOT region significantly affected TAVI outcome, as they were independent predictors of device success. Lotus and Portico seemed to perform better than Evolut-R as for device success and ≥ moderate PVL. Computational simulations revealed unique biomechanical features of the investigated devices in terms of stent compliance and radial force.

13.
Catheter Cardiovasc Interv ; 99(4): 1277-1286, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34939726

RESUMO

OBJECTIVES: To evaluate the prognostic impact of baseline tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio, as an expression of the right ventricle-pulmonary artery (RV-PA) coupling, in patients with mitral regurgitation (MR) treated with the MitraClip. BACKGROUND: Impaired RV to PA coupling is considered a marker of RV dysfunction. METHODS: From February 2016 to February 2020, a total of 165 patients were evaluated and stratified in two groups according to a prespecified value of TAPSE/PASP ratio ≤ 0.36. RESULTS: The median patients' age was 79 (men: 62.4%). Sixty-three patients (38.1%) presented TAPSE/PASP ≤ 0.36 and were then compared with patients with TAPSE/PASP > 0.36. Functional MR etiology was more frequent in TAPSE/PASP ≤ 0.36 (71.4%; p = 0.046). Acute technical success was achieved in 92.7% of the population, without any significant difference between the two groups of study and with sustained results at 30-day (device success: 85.5%; procedural success: 84.8%). On multivariate Cox regression analysis, after correction for body mass index, chronic kidney disease and left ventricle ejection fraction ≥30% but <50%, TAPSE/PASP ≤ 0.36 remained a sustained predictor of mortality and hospitalization for heart failure at one year after MitraClip (hazard ratio: 3.87; 95% confidence interval: 1.83-8.22; p ≤ 0.001). Kaplan-Meier all-cause mortality and heart failure hospitalization rates at one year were consequently higher in patients with TAPSE/PASP ≤ 0.36 (39.4% vs. 14.8%; log-rank p ≤ 0.001). CONCLUSION: Baseline TAPSE/PASP ratio seems independently associated with all-cause mortality and heart failure hospitalization after MitraClip both in functional and degenerative MR.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Ventrículos do Coração , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Artéria Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Função Ventricular Direita
14.
Catheter Cardiovasc Interv ; 100(3): 451-460, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35644994

RESUMO

BACKGROUND: Mitral-valve transcatheter edge-to-edge repair (MV-TEER) is recommended in patients with severe functional mitral regurgitation (FMR) and in those with degenerative mitral regurgitation (DMR) not eligible to traditional surgery. Patients with a history of previous cardiac surgery are considered at high risk for surgical reintervention, but data are lacking regarding procedural and clinical outcomes. OBJECTIVE: aim of this study was to assess the efficacy and clinical results of MV-TEER in patients with previous cardiac surgery enrolled in the "multicentre Italian Society of Interventional Cardiology registry of transcatheter treatment of mitral valve regurgitation" (GIOTTO). METHODS: Patients with previous coronary artery bypass grafting (CABG), surgical aortic valve replacement (AVR), or mitral valve repair (MVR) were included. Those with multiple or combined previous cardiac surgeries were excluded. Clinical follow-up was performed at 30 days, 1 year, and 2 years. The primary endpoint was a composite of death or rehospitalization at 1- and 2-year follow-ups. RESULTS: A total of 330 patients enrolled in the GIOTTO registry were considered (CABG 77.9%, AVR 14.2%, and MVR 7.9%). Most patients showed FMR (66.9%), moderate reduction of left ventricular (LV) ejection fraction, and signs of LV dilation. Procedural and device successes were 94.8% and 97%. At 1 and 2 years, the composite endpoint occurred are 29.1% and 52.4%, respectively. The composite outcome rates were similar across the three subgroups of previous cardiac surgery (p = 0.928) and between the FMR and DMR subgroups (p = 0.850) at 2 years. In a multivariate analysis, residual mitral regurgitation (rMR) ≥2+ was the main predictor of adverse events at 1 year (hazard ratio: 1.54 [95% confidence interval, CI: 1.00-2.38]; p = 0.050). This association was confirmed at 2 years of Kaplan-Meier analysis (p = 0.001). CONCLUSIONS: MV-TEER is effective in these patients, regardless of the subtype of previous cardiac surgery and the MR etiology. An rMR ≥2+ is independently associated with adverse outcomes at 1-year follow-up.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 99(3): 889-895, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34390296

RESUMO

OBJECTIVES: We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. BACKGROUND: The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. METHODS: Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. RESULTS: Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 ± 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 ± 0.8% and 2.2 ± 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 ± 0.2 vs. 2.1 ± 0.6 cm2 ) and mean aortic valve gradient (43.4 ± 11.1 vs. 9.0 ± 3.7 mmHg) improved significantly (p < 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. CONCLUSIONS: Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
16.
Eur Heart J ; 42(16): 1545-1553, 2021 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-33507260

RESUMO

Patent foramen ovale (PFO) is implicated in the pathogenesis of a number of medical conditions but to date only one official position paper related to left circulation thromboembolism has been published. This interdisciplinary paper, prepared with the involvement of eight European scientific societies, reviews the available evidence and proposes a rationale for decision making for other PFO-related clinical conditions. In order to guarantee a strict evidence-based process, we used a modified grading of recommendations, assessment, development, and evaluation (GRADE) methodology. A critical qualitative and quantitative evaluation of diagnostic and therapeutic procedures was performed, including assessment of the risk/benefit ratio. The level of evidence and the strength of the position statements were weighed and graded according to predefined scales. Despite being based on limited and observational or low-certainty randomised data, a number of position statements were made to frame PFO management in different clinical settings, along with suggestions for new research avenues. This interdisciplinary position paper, recognising the low or very low certainty of existing evidence, provides the first approach to several PFO-related clinical scenarios beyond left circulation thromboembolism and strongly stresses the need for fresh high-quality evidence on these topics.


Assuntos
Doença da Descompressão , Forame Oval Patente , Transtornos de Enxaqueca , Tromboembolia , Doença da Descompressão/terapia , Forame Oval Patente/complicações , Forame Oval Patente/terapia , Humanos , Síndrome , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
17.
Circulation ; 142(25): 2431-2442, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33054367

RESUMO

BACKGROUND: Few randomized trials have compared bioprostheses for transcatheter aortic valve replacement, and no trials have compared bioprostheses with supra-annular design. The SCOPE 2 trial (Safety and Efficacy Comparison of Two TAVI Systems in a Prospective Randomized Evaluation 2) was designed to compare the clinical outcomes of the ACURATE neo and CoreValve Evolut bioprostheses for transcatheter aortic valve replacement. METHODS: SCOPE 2 was a randomized trial performed at 23 centers in 6 countries between April 2017 and April 2019. Patients ≥75 years old with an indication for transfemoral transcatheter aortic valve replacement as agreed by the heart team were randomly assigned to receive treatment with either the ACURATE neo (n=398) or the CoreValve Evolut bioprostheses (n=398). The primary end point, powered for noninferiority of the ACURATE neo bioprosthesis, was all-cause death or stroke at 1 year. The key secondary end point, powered for superiority of the ACURATE neo bioprosthesis, was new permanent pacemaker implantation at 30 days. RESULTS: Among 796 randomized patients (mean age, 83.2±4.3 years; mean Society of Thoracic Surgeons Predicted Risk of Mortality score, 4.6±2.9%), clinical follow-up information was available for 778 (98%) patients. Within 1 year, the primary end point occurred in 15.8% of patients in the ACURATE neo group and in 13.9% of patients in the CoreValve Evolut group (absolute risk difference, 1.8%, upper 1-sided 95% confidence limit, 6.1%; P=0.0549 for noninferiority). The 30-day rates of new permanent pacemaker implantation were 10.5% in the ACURATE neo group and 18.0% in the CoreValve Evolut group (absolute risk difference, -7.5% [95% CI, -12.4 to -2.60]; P=0.0027). No significant differences were observed in the components of the primary end point. Cardiac death at 30 days (2.8% versus 0.8%; P=0.03) and 1 year (8.4% versus 3.9%; P=0.01), and moderate or severe aortic regurgitation at 30 days (10% versus 3%; P=0.002) were significantly increased in the ACURATE neo group. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement with the self-expanding ACURATE neo did not meet noninferiority compared with the self-expanding CoreValve Evolut in terms of all-cause death or stroke at 1 year, and it was associated with a lower incidence of new permanent pacemaker implantation. In secondary analyses, the ACURATE neo was associated with more moderate or severe aortic regurgitation at 30 days and cardiac death at 30 days and 1 year. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03192813.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
18.
Am Heart J ; 232: 23-38, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33160946

RESUMO

BACKGROUND: The recent approval of transcatheter aortic valve replacement (TAVR) in patients with low operative risk has paved the way for the introduction of novel and potentially improved technologies. The safety and efficacy of these novel technologies should be investigated in randomized control trials against the contemporary TAVR devices. The objective of the LANDMARK trial is to compare the balloon-expandable Myval transcatheter heart valve (THV) series with contemporary THV (SAPIEN THV and Evolut THV series) series in patients with severe symptomatic native aortic stenosis. METHODS/DESIGN: The LANDMARK trial (ClinicalTrials.govNCT04275726, EudraCT number 2020-000,137-40) is a prospective, randomized, multinational, multicenter, open-label, and noninferiority trial of approximately 768 patients treated with TAVR via the transfemoral approach. Patients will be allocated in a 1:1 randomization to Myval THV series (n = 384) or to contemporary THV (n = 384) (either of SAPIEN THV or Evolut THV series). The primary combined safety and efficacy endpoint is a composite of all-cause mortality, all stroke (disabling and nondisabling), bleeding (life-threatening or disabling), acute kidney injury (stage 2 or 3), major vascular complications, prosthetic valve regurgitation (moderate or severe), and conduction system disturbances (requiring new permanent pacemaker implantation), according to the Valve Academic Research Consortium-2 criteria at 30-day follow-up. All patients will have follow-up to 10 years following TAVR. SUMMARY: The LANDMARK trial is the first randomized head-to-head trial comparing Myval THV series to commercially available THVs in patients indicated for TAVR. We review prior data on head-to-head comparisons of TAVR devices and describe the rationale and design of the LANDMARK trial.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Insuficiência da Valva Aórtica/epidemiologia , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Estudos de Equivalência como Asunto , Humanos , Mortalidade , Marca-Passo Artificial , Hemorragia Pós-Operatória/epidemiologia , Desenho de Prótese , Falha de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Índice de Gravidade de Doença , Acidente Vascular Cerebral/epidemiologia
19.
Catheter Cardiovasc Interv ; 98(6): E847-E854, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33960624

RESUMO

AIMS: The aim of this proof-of-concept study was to investigate safety and efficacy of a CT-scan based patient-specific algorithm to maximize coronary clearance and secondarily to achieve anatomically correct commissural alignment with the Acurate Neo device. METHOD AND RESULTS: A total of 45 consecutive patients undergoing TAVR with the Acurate Neo THV were prospectively enrolled in the study. Mean age was 81.6 ± 5.5 years, mean STS score was 6.1 ± 3.7. Device success rate was 100%. Aim of the technique was to rotationally deploy the TAVR device with a commissure lying on the bisector between the coronary ostia as calculated on the pre-procedural CT-scan. At post-TAVR CT-scan, coronary clearance was achieved in 98% of patients with no cases of severe coronary artery overlap. In 42 out of 45 patients, THV was aligned or, at most, mildly misaligned; there were 2 cases of moderate misalignment without any case of severe misalignment. Post-TAVR selective coronary artery engagement was attempted and succeeded in all patients (100%). CONCLUSION: Our CT-scan based patient-specific algorithm is safe and proven to be effective in avoiding coronary artery overlap and providing commissural alignment with Acurate Neo in all treated patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 98(1): E145-E152, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33155757

RESUMO

OBJECTIVE: This study sought to investigate the procedural and mid-term outcomes of transcatheter aortic valve implantation for failed surgical bioprostheses (TAVI-ViV) with Portico device. BACKGROUND: Limited evidence coming from early experience on Portico system does not allow to fully assess safety and efficacy of this device in this ViV patients. METHODS: From January 2016 up to June 2019, 56 consecutive patients undergoing TAVI-ViV with Portico were prospectively included in our institutional TAVI database. RESULTS: The prevalent mechanism of failure was stenosis (58.9%); true internal diameter (ID) was <21 mm in 71.4% of cases. Device success rate were 69.6% with 14 (25%) patients showing a residual gradient ≥20 mmHg, 2 (3.6%) a PVL ≥ moderate and 1 (1.8%) required a second THV implantation due to device embolization. At 1-year follow-up 5 patients (8.9%) died whereas moderate SVD was reported in 2 (3.6%). Patients with a post-procedural mean gradient ≥20 mmHg showed a significantly higher rate of CV hospitalization (21.4% vs. 2.4%, p = .02) whereas no differences in procedural and 1-year outcomes were noticed according to true ID diameter or degeneration mode. Chimney stenting (ChT) was performed in 23 (41%) patients without significant differences in procedural and 1-year outcomes compared to non-ChT group. CONCLUSIONS: TAVI-ViV with Portico valve was associated with good procedural and 1-year outcomes, even in patients with features of high procedural and anatomical complexity.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA