Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Microbiol ; 2023: 7803864, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36846152

RESUMO

Clinical decision-making regarding isolation of SARS-CoV-2 patients is usually based on semiquantitative cycle-threshold (Ct) values without standardization. However, not all molecular assays produce Ct values, and there is ongoing discussion about whether Ct values can be safely used for decision-making. In this study, we standardized two molecular assays which use different nucleic acid amplification techniques (NAAT): the Hologic Aptima SARS-CoV-2/Flu (TMA) and Roche Cobas 6800 SARS-CoV-2 assays. We calibrated these assays against the first WHO international standard for SARS-CoV-2 RNA by using linear regression of log10 dilution series. These calibration curves were used to calculate viral loads for clinical samples. Clinical performance was assessed retrospectively using samples collected between January 2020 and November 2021, including known positives of the wild-type SARS-CoV-2 virus, the VOCs (alpha, beta, gamma, delta, and omicron) and quality control panels. Linear regression and Bland-Altman analysis showed good correlations for SARS-CoV-2 between Panther TMA and Cobas 6800 when standardized viral loads were used. These standardized quantitative results can benefit clinical decision-making and standardization of infection control guidelines.

2.
Viruses ; 12(9)2020 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-32887284

RESUMO

Substantial efforts to eliminate or reduce latent HIV-1 reservoirs are underway in clinical trials and have created a critical demand for sensitive, accurate, and reproducible tools to evaluate the efficacy of these strategies. Alternative reservoir quantification assays have been developed to circumvent limitations of the quantitative viral outgrowth assay. One such assay is tat/rev induced limiting dilution assay (TILDA), which measures the frequency of CD4+ T cells harboring inducible latent HIV-1 provirus. We modified pre-amplification reagents and conditions (TILDA v2.0) to improve assay execution and first internally validated assay performance using CD4+ T cells obtained from cART-suppressed HIV-1-infected individuals. Detection of tat/rev multiply spliced RNA was not altered by modifying pre-amplification conditions, confirming the robustness of the assay, and supporting the technique's amenability to limited modifications to ensure better implementation for routine use in clinical studies of latent HIV-1 reservoirs. Furthermore, we cross-validated results of TILDA v2.0 and the original assay performed in two separate laboratories using samples from 15 HIV-1-infected individuals. TILDA and TILDA v2.0 showed a strong correlation (Lin's Concordance Correlation Coefficient = 0.86). The low inter-laboratory variability between TILDAs performed at different institutes further supports use of TILDA for reservoir quantitation in multi-center interventional HIV-1 Cure trials.


Assuntos
Infecções por HIV/virologia , HIV-1/isolamento & purificação , Virologia/métodos , Adulto , Linfócitos T CD4-Positivos/virologia , Feminino , Infecções por HIV/diagnóstico , HIV-1/genética , HIV-1/fisiologia , Humanos , Laboratórios , Masculino , Pessoa de Meia-Idade , Provírus/genética , Provírus/isolamento & purificação , Provírus/fisiologia , Reprodutibilidade dos Testes , Latência Viral , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA