Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 90: 100-108, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36270548

RESUMO

BACKGROUND: Obtaining a suitable proximal landing zone in blunt thoracic aortic injuries (BTAI) often necessitates coverage of the left subclavian artery (LSA). This study aimed to evaluate the outcomes of physician-modified endovascular grafts (PMEGs) in this indication. METHODS: We performed a retrospective analysis of a prospective registry including all patients who had undergone a thoracic endovascular aortic repair (TEVAR) for BTAI from October 2008 to October 2020. Starting in 2015, patients requiring coverage of the LSA were either treated using a physician-modified proximal scalloped or single-fenestrated stent graft. After an early postoperative computed tomography scan, follow-up was performed at 3 months, 6-months, and yearly. RESULTS: Among 58 patients treated with TEVAR for BTAI, 23 (39.6%) patients required a zone 2 landing zone of which 10 (17.2%) patients were treated with PMEGs. The median age was 48 [31-64.5] years, and 78.2% (n = 18) patients were male. The median Injury Severity Score was 38 [27-55.5]. Coverage of the LSA was performed in 25.8% (n = 15) of the total population in which 5 patients had an LSA transposition. The median modification time was 18 [14-27] minutes. Technical success of PMEGs was 90.0% overall and 100% for fenestrated stent grafts. No stroke, paraplegia, or retrograde dissection was observed. The primary patency of the LSA in the PMEGs group was 90 % at 1 year and 28.8 % in the LSA coverage group (P < 0.01). CONCLUSIONS: The use of PMEGs is feasible and effective in the management of BTAI with a short proximal landing zone. Further evaluation of long-term outcomes and durability are awaited.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Stents , Estudos Retrospectivos , Resultado do Tratamento , Aorta Torácica/cirurgia , Procedimentos Endovasculares/efeitos adversos
2.
J Vasc Surg ; 76(5): 1133-1140.e2, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35697312

RESUMO

OBJECTIVE: We evaluated the early- and medium-term outcomes of single- and double-fenestrated physician-modified endovascular grafts (PMEGs) for total endovascular degenerative aortic arch aneurysm repair. METHODS: We performed a single-center, retrospective analysis of prospectively collected data from 52 patients from August 2013 through January 2021 who had undergone homemade fenestrated thoracic endovascular aortic repair for degenerative aortic aneurysms. In all cases, a distal smaller fenestration for the left subclavian artery (LSA) was fashioned and was the only one stented. For a double-fenestrated endograft, a proximal larger fenestration that incorporated both the brachiocephalic trunk and the left common carotid artery was added. RESULTS: A total of 52 patients with degenerative aortic arch aneurysms were treated. Of the 52 patients, 36 were men, the mean age was 75 ± 8 years, 31% had received a single LSA fenestration, and 69% had undergone double-fenestrated thoracic endovascular aortic repair. Of the 52 procedures, 5 (10%) were emergent procedures. The technical success was 100%. The median time required for stent graft modification was 22 ± 6 minutes. The 30-day mortality was 2% (n = 1). Five patients (10%) had experienced a cerebrovascular event, including two transient ischemic attacks, one minor stroke with full neurologic recovery, and two with sequelae. Two patients (4%) had experienced perioperative retrograde dissection during follow-up. No patient had developed a type I, II, or III endoleak from the LSA. No patient had required reintervention. All supra-aortic trunks were patent. During a mean follow-up of 18 ± 11 months, no patient had required conversion to open surgical repair, aortic rupture, or paraplegia. CONCLUSIONS: Single or double PMEG is a safe and suitable tool for the treatment of high morbidity pathology such as aortic arch degenerative aneurysm repair. In addition, this device can be used in patients requiring elective or emergency repair.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Médicos , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Resultado do Tratamento , Complicações Pós-Operatórias/terapia , Fatores de Risco , Fatores de Tempo , Stents/efeitos adversos , Aneurisma Aórtico/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA