Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 59(8)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37629658

RESUMO

Background and Objectives: Pulmonary complications are a leading cause of morbidity after cardiac surgery. The aim of this study was to develop models to predict postoperative lung dysfunction and mortality. Materials and Methods: This was a single-center, observational, retrospective study. We retrospectively analyzed the data of 11,285 adult patients who underwent all types of cardiac surgery from 2003 to 2015. We developed logistic predictive models for in-hospital mortality, postoperative pulmonary complications occurring in the intensive care unit, and postoperative non-invasive mechanical ventilation when clinically indicated. Results: In the "preoperative model" predictors for mortality were advanced age (p < 0.001), New York Heart Association (NYHA) class (p < 0.001) and emergent surgery (p = 0.036); predictors for non-invasive mechanical ventilation were advanced age (p < 0.001), low ejection fraction (p = 0.023), higher body mass index (p < 0.001) and preoperative renal failure (p = 0.043); predictors for postoperative pulmonary complications were preoperative chronic obstructive pulmonary disease (p = 0.007), preoperative kidney injury (p < 0.001) and NYHA class (p = 0.033). In the "surgery model" predictors for mortality were intraoperative inotropes (p = 0.003) and intraoperative intra-aortic balloon pump (p < 0.001), which also predicted the incidence of postoperative pulmonary complications. There were no specific variables in the surgery model predicting the use of non-invasive mechanical ventilation. In the "intensive care unit model", predictors for mortality were postoperative kidney injury (p < 0.001), tracheostomy (p < 0.001), inotropes (p = 0.029) and PaO2/FiO2 ratio at discharge (p = 0.028); predictors for non-invasive mechanical ventilation were kidney injury (p < 0.001), inotropes (p < 0.001), blood transfusions (p < 0.001) and PaO2/FiO2 ratio at the discharge (p < 0.001). Conclusions: In this retrospective study, we identified the preoperative, intraoperative and postoperative characteristics associated with mortality and complications following cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Adulto , Humanos , Estudos Retrospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Mortalidade Hospitalar , Índice de Massa Corporal , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
2.
Eur Heart J Suppl ; 23(Suppl E): E6-E12, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34650350

RESUMO

In the last years, there has been a trend to prefer biological prostheses, especially among young patients, with the aim to avoid anticoagulant treatment. Surgical tissue valves have so far demonstrated their solid long-term durability. However, younger age has been identified as one of the main risk factors for developing structural valve deterioration (SVD). As a consequence, the proportion of subjects at risk for valve dysfunction will constantly rise in the near future. However, while surgical reintervention has always been considered the gold standard for treatment of prosthesis deterioration, the introduction of transcatheter heart valves could offer new therapeutical options, particularly among high-risk patients, aiming a second less invasive chance. The recent standardization of valve durability definitions will soon allow a more comprehensive understanding of the mechanism underlying SVD and guide the choice of prosthesis for patients needing valve replacement.

3.
J Card Surg ; 36(7): 2546-2548, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33797811

RESUMO

Sutureless aortic bioprostheses were introduced more than ten years ago, with the aim of decreasing cross-clamp time and thus becoming the first choice in older patients for many surgeons. However, published data are limited to a 5-year follow-up, and some cases of deterioration have already been described. High-risk patients who once have benefitted from a fast sutureless aortic replacement and now are experiencing a prosthesis dysfunction, could take advantage of a percutaneous Valve-in-Sutureless technique. Furthermore, thanks to technological improvement, new transcatheter prostheses have been designed, allowing a more precise positioning. In this report, we described the first Myval-in-Perceval case, which resulted in a safe and effective procedure.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos sem Sutura , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
4.
Eur Heart J Suppl ; 22(Suppl L): L1-L5, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33654459

RESUMO

During the last decade, transcatheter aortic valve implantation (TAVI) has represented a valid alternative to surgical aortic valve replacement in patients with aortic stenosis and elevated surgical risk. Recent randomized clinical trials reported excellent results also for patients at low surgical risk, but in clinical practice, the mean age of the patients treated remain over 75 years, and the presence of a bicuspid aortic valve still represents an important exclusion criteria. Today, aortic valve replacement with a mechanical prosthesis remains the treatment of choice for young adults with aortic stenosis, although the desire to avoid oral anticoagulants drives more patients younger than 65 years of age towards biological prostheses. Furthermore, despite the follow-up of patients after TAVI is still limited to a few years, the opportunity of a second percutaneous treatment (TAVI-in-TAVI), extends the scope of percutaneous strategy. In the next few years, TAVI has to face many challenges to become a valid alternative to surgery in the younger patients as well.

5.
J Card Surg ; 35(1): 229-231, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31614014

RESUMO

Acute aortic arch dissections represent life-threatening conditions with a high rate of mortality and neurological complications. Past longer techniques included an "en bloc" replacement of epiaortic vessels or the frozen elephant trunk (FET) procedure with conventional grafts for chronic dilatation. In this report, we described a case of an acute aortic dissection in a patient with aberrant right subclavian artery and challenging sovra-aortic vessel anatomy, treated with the new custom-made E-Vita Open Plus FET graft.


Assuntos
Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Desenho de Prótese , Doença Aguda , Humanos , Masculino , Pessoa de Meia-Idade
6.
J Card Surg ; 35(2): 477-479, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31765015

RESUMO

Aortic valve replacement still represents the gold standard treatment for severe symptomatic aortic stenosis. Sutureless bioprostheses have been so far developed to enhance the minimally invasive approach, resulting in a reduction of cross-clamp time. Even if the first implantation was carried out more than 10 years ago, some cases of valve degeneration treated with balloon-expandable valve-in-valve procedures have been previously described in the literature. Here, we present a case of early sutureless valve degeneration resulting in severe aortic regurgitation. After careful evaluation of the patient's comorbidities, a successful valve-in-valve was finally performed using a self-expandable transcatheter prosthesis. A wide discussion of the Heart Team decision-making process and of the technical aspects has been addressed.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Falha de Prótese , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Humanos , Masculino , Índice de Gravidade de Doença , Resultado do Tratamento
9.
JACC Case Rep ; 28: 102090, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38204541

RESUMO

We report a case of patient with a single-chamber Hisian pacemaker who developed complete atrioventricular block and significant deterioration of the ventricular threshold and sensing after transcatheter aortic valve replacement. Revision of the implantation was required, with ventricular lead extraction and replacement.

10.
Eur J Cardiothorac Surg ; 64(4)2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37551944

RESUMO

OBJECTIVES: Uncorrected severe mitral regurgitation (MR) due to posterior prolapse leads to left ventricular dilatation. At this stage, mitral valve repair becomes mandatory to avoid permanent myocardial injury. However, which technique among neochoardae implantation and leaflet resection provides the best results in this scenario remains unknown. METHODS: We selected 332 patients with left ventricular dilatation and severe degenerative MR due to posterior leaflet (PL) prolapse who underwent neochoardae implantation (85 patients) or PL resection (247 patients) at our institution between 2008 and 2020. A propensity score matching analysis was carried on to decrease the differences at baseline. RESULTS: Matching yielded 85 neochordae implantations and 85 PL resections. At 10 years, freedom from cardiac death and freedom from mitral valve reoperation were 92.6 ± 6.1% vs 97.8 ± 2.1% and 97.7 ± 2.2% vs 95 ± 3% in the neochordae group and in the PL resection group, respectively. The MR ≥2+ recurrence rate was 23.9 ± 10% in the neochordae group and 20.8 ± 5.8% in the PL resection group (P = 0.834) at 10 years. At the last follow-up, the neochordae group showed a higher reduction of left ventricular end-diastolic diameter (44 vs 48 mm; P = 0.001) and a better ejection fraction (60% vs 55%; P < 0.001) compared to PL resection group. CONCLUSIONS: In this subgroup of patients, both neochordae implantation and leaflet resection provide excellent durability of the repair in the long term. Neochordae implantation might have a better effect on dilated left ventricle.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Pontuação de Propensão , Resultado do Tratamento , Cordas Tendinosas/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Prolapso
11.
JACC Cardiovasc Interv ; 16(8): 927-941, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37100556

RESUMO

BACKGROUND: Valve reintervention after transcatheter aortic valve replacement (TAVR) failure has not been studied in detail. OBJECTIVES: The authors sought to determine outcomes of TAVR surgical explantation (TAVR-explant) vs redo-TAVR because they are largely unknown. METHODS: From May 2009 to February 2022, 396 patients in the international EXPLANTORREDO-TAVR registry underwent TAVR-explant (181, 46.4%) or redo-TAVR (215, 54.3%) for transcatheter heart valve (THV) failure during a separate admission from the initial TAVR. Outcomes were reported at 30 days and 1 year. RESULTS: The incidence of reintervention after THV failure was 0.59% with increasing volume during the study period. Median time from index-TAVR to reintervention was shorter in TAVR-explant vs redo-TAVR (17.6 months [IQR: 5.0-40.7 months] vs 45.7 months [IQR: 10.6-75.6 months]; P < 0.001], respectively. TAVR-explant had more prosthesis-patient mismatch (17.1% vs 0.5%; P < 0.001) as the indication for reintervention, whereas redo-TAVR had more structural valve degeneration (63.7% vs 51.9%; P = 0.023), with a similar incidence of ≥moderate paravalvular leak between groups (28.7% vs 32.8% in redo-TAVR; P = 0.44). There was a similar proportion of balloon-expandable THV failures (39.8% TAVR-explant vs 40.5% redo-TAVR; P = 0.92). Median follow-up was 11.3 (IQR: 1.6-27.1 months) after reintervention. Compared with redo-TAVR, TAVR-explant had higher mortality at 30 days (13.6% vs 3.4%; P < 0.001) and 1 year (32.4% vs 15.4%; P = 0.001), with similar stroke rates between groups. On landmark analysis, mortality was similar between groups after 30 days (P = 0.91). CONCLUSIONS: In this first report of the EXPLANTORREDO-TAVR global registry, TAVR-explant had a shorter median time to reintervention, with less structural valve degeneration, more prosthesis-patient mismatch, and similar paravalvular leak rates compared with redo-TAVR. TAVR-explant had higher mortality at 30 days and 1 year, but similar rates on landmark analysis after 30 days.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Sistema de Registros , Desenho de Prótese
12.
Ann Cardiothorac Surg ; 10(1): 15-27, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33575172

RESUMO

Patients with severe symptomatic mitral regurgitation, if left untreated, have a poor prognosis. In those patients not eligible for mitral valve (MV) surgery, percutaneous repair may improve clinical outcomes. In the past 15 years several devices have been developed to address different MV lesions. This manuscript will review the advancement of transcatheter MV repair through the years, focusing on technologies for which consistent clinical data is available.

13.
Eur J Cardiothorac Surg ; 60(4): 850-856, 2021 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-33778846

RESUMO

OBJECTIVES: Previous series showed the outcomes of thoracoscopic ablation of stand-alone symptomatic paroxysmal atrial fibrillation (AF) for up to 7 years of follow-up. The goal of this study was to assess the long-term durability of surgical pulmonary vein isolation (PVI) beyond 7 years. METHODS: Fifty consecutive patients {mean age 55 [standard deviation (SD): 11.2] years, previous catheter ablation in 56%, left ventricular ejection fraction 60% (SD: 4.6), left atrium volume 65 ml (SD: 17)} with stand-alone symptomatic paroxysmal AF underwent PVI through bilateral thoracoscopy ablation between 2005 and 2014. The CHA2DS2-VASc score was ≥2 in 12 patients (24%). RESULTS: No hospital deaths occurred. At hospital discharge all patients but 1 (2%) were in sinus rhythm (SR). Follow-up was 100% complete [mean 8.4 years (SD: 2.3), max 15]. The 8-year cumulative incidence function of AF recurrence, with death as a competing risk, on or off class I/III antiarrhythmic drugs (AADs)/electrocardioversion/re-transcatheter ablation (TCA) was 20% (SD: 5; 95% confidence interval: 10, 32); and off class I/III AADs/electrocardioversion/re-TCA was 52% (SD: 7; 95% confidence interval: 0.83, 8.02). At 8 years, the predicted prevalence of patients in SR was 87% and 53% were off class I/III AADs/electrocardioversion/re-TCA. The recurrent arrhythmia was AF in all patients except 2, who had atypical atrial flutter (4%). No predictors of AF recurrence were identified. At the last follow-up, 76% of the patients showed European Heart Rhythm Association class I. No strokes or thromboembolic events were documented and 76% of the subjects were off anticoagulation therapy. CONCLUSIONS: Despite a considerable AF recurrence rate, our single-centre, long-term outcome of surgical PVI showed encouraging data, with the majority of patients remaining in SR, although many of them were on antiarrhythmic therapy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
14.
EuroIntervention ; 16(18): e1533-e1540, 2021 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-32364502

RESUMO

AIMS: The expansion of TAVI will involve an increase in the frequency of emergent or late cardiac surgery after THV implantation. This study was designed to investigate the anatomical feasibility of surgical cross-clamp and aortotomy after TAVI through a post-TAVI CT-scan assessment. METHODS AND RESULTS: We retrospectively analysed 117 CTs acquired after TAVI procedures with high stent prostheses in three high-volume centres between October 2008 and May 2017. The mean distance observed between the innominate artery and the top of the transcatheter heart valve was 45±11 mm, being <30 mm in 8/117 (6.8%) patients and <20 mm in none. The mean distance between the sinotubular junction and the first free site for aortotomy was 22±7 mm (>20 mm in 78/117 [66.7%] cases). A total of 56/117 (47.9%) patients showed a complete continuous contact between the anterior aortic wall and the anterior part of the valve stent. CONCLUSIONS: Aortic cross-clamp appears not to be an issue when cardiac surgery is needed after TAVI; however, a careful and possibly higher aortotomy may be required. CT should be performed prior to planned cardiac surgery after TAVI to determine a safe positioning for aortic cross-clamp and aortotomy.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Aorta/diagnóstico por imagem , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Int J Cardiol Heart Vasc ; 34: 100817, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34169142

RESUMO

INTRODUCTION: Based on recent data, the indication for transcatheter aortic valve implantation (TAVI) is expanding to individuals at lower surgical risk, who are generally younger than subjects historically treated for severe aortic stenosis. Indeed, younger patients have traditionally been under-represented in current TAVI literature. The aim of the present study is to report about clinical features, procedural outcomes and mid-term outcomes of patients younger than 70 who underwent TAVI in a single high-volume center. MATERIALS AND METHODS: Consecutive patients younger than 70 years of age who underwent TAVI for severe, symptomatic aortic stenosis between 2007 and 2019 at a single, tertiary referral center have been included in this retrospective study. Procedural and mid-term outcomes were analyzed, comparing 1st generation with 2nd generation devices. RESULTS: Between 2007 and 2019, 1740 TAVI procedures were performed in our center. Among these, one hundred twenty-nine (7.4%) patients were younger than 70 years at the time of the intervention and were included in the present analysis. Fifty-eight patients (45%) were implanted with a 1st generation prosthesis while seventy-one patients (55%) were implanted with a 2nd generation device. Reasons which lead to a transcatheter approach in this population were: previous CABG (27.9%); porcelain aorta (24%); severe left ventricular systolic dysfunction (21.7%); prior chest radiation (19.4%); severe lung disease (8.5%); hemodynamic instability (7.0%); advanced liver disease (4.6%) and active cancer (3.9%). Overall device success rate was 89%, with no differences among 1st and 2nd generation devices. Threeyears all-cause mortality was 34%, with no difference among the two groups. Low incidence of aortic-valve re-intervention was observed at mid-term follow-up (late valve re-intervention = 2.3%). CONCLUSIONS: TAVI in young patient with appropriate indication for intervention is a safe procedure, associated with low rate of in hospital mortality and low rate of severe complications both with 1st and with 2nd generation devices. When considering long term durability, more data are needed; in our case series long-term follow up shows a good survival and also an extremely low rate of valve re-intervention.

16.
Artigo em Inglês | MEDLINE | ID: mdl-32459076

RESUMO

As the number of young and relatively low-risk patients undergoing transcatheter aortic valve implantation increases, the number who will require open heart surgery months or years later will also increase. Only a few cases of late transcatheter heart valve explantation (without root replacement) have been reported in the literature, and this rare procedure can be surgically very challenging. In this video tutorial we present the case of a patient with a valve-in-valve subacute thrombosis, and we describe the surgical technique for valve explantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Remoção de Dispositivo/métodos , Reoperação/métodos , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Trombose/etiologia , Trombose/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
17.
Eur J Cardiothorac Surg ; 58(2): 343-349, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32187351

RESUMO

OBJECTIVES: The aim of this study is to evaluate the immediate and mid-term effects of omitting coronary artery bypass grafting in patients with moderate coronary artery stenosis who have a primary indication for valvular surgery. METHODS: We included 77 consecutive patients admitted to our Institution for aortic or mitral valve surgery between June 2012 and June 2017 in whom a de novo diagnosis of ≥50%, but <70% coronary stenosis was made. In this cohort, the myocardial revascularization was omitted. All these patients were free from angina and ischaemia on echo and ECG. RESULTS: There were no in-hospital deaths. In only 1 patient, acute myocardial infarction occurred postoperatively, which was immediately treated by percutaneous coronary intervention (PCI). The 6-year overall survival was 94.7 ± 2.59%. At 6 years, no cardiac deaths were recorded. At follow-up, 4 patients underwent elective PCI after a positive stress myocardial perfusion test. Only 1 patient underwent urgent PCI due to acute coronary syndrome. At 6 years, the cumulative incidence function of PCI, with death as competing risk, was 8 ± 3.9%. CONCLUSIONS: In our experience, moderate coronary stenosis, occasionally discovered at the time of valvular heart surgery, can be safely overlooked and do not need any further treatment at follow-up in the majority of cases. Our results open up the opportunity to apply this 'intentional omission strategy' in different situations, such as minimally invasive heart surgery, percutaneous procedures and complex patients.


Assuntos
Estenose Coronária , Infarto do Miocárdio , Intervenção Coronária Percutânea , Ponte de Artéria Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Humanos , Revascularização Miocárdica , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
18.
Interact Cardiovasc Thorac Surg ; 31(1): 28-34, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32221590

RESUMO

OBJECTIVES: Previous series of minimally invasive mitral valve repairs showed excellent results at up to 10 years of follow-up. The goal of this study was to assess the long-term durability beyond 10 years of the edge-to-edge repair for myxomatous degeneration performed through a minimally invasive approach. METHODS: Ninety-seven consecutive patients (mean age 35 ± 9 years; left ventricular ejection fraction 63 ± 6%) with severe myxomatous mitral regurgitation (MR) underwent mitral valve repair through a right minithoracotomy between 1999 and 2006. MR was due to lesions involving the posterior leaflet (7.2% of patients), anterior leaflet (12.4%) and both leaflets (80.4%). RESULTS: No hospital deaths occurred. At hospital discharge all patients had no or trivial MR. Follow-up was 100% complete (median 15.5 years; interquartile range 13.6-17.0, max 19.3 years). The 16-year overall survival rate was 95.9 ± 2.02% [95% confidence interval (CI) 89.39-98.43]. At 16 years, the cumulative incidence function of cardiac death, with non-cardiac death as a competing risk, was 3.1 ± 1.75 (95% CI 0.83-8.02). Only 3 patients (4.1%) had redo operations for recurrent severe MR. At 16 years, the cumulative incidence functions of reoperation for and recurrence of MR ≥3+, with death as a competing risk, were 3.1 ± 1.76% (95% CI 0.83-8.02) and 5.6 ± 2.47% (95% CI 2.06-11.83), respectively. No predictors of recurrence of MR ≥3+ were identified. At the last follow-up, moderate MR (2+/4+) was detected in 17 patients (17.5%); most of the patients were in New York Heart Association functional class I-II (97%) and in sinus rhythm (90%). CONCLUSIONS: Minimally invasive mitral valve edge-to-edge repair through a right minithoracotomy for myxomatous degeneration appears to be an effective and durable approach even in the long-term follow-up (up to 19 years).


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Adulto , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Recidiva , Reoperação , Taxa de Sobrevida/tendências , Toracotomia/métodos , Fatores de Tempo , Resultado do Tratamento
19.
Artigo em Inglês | MEDLINE | ID: mdl-30990579

RESUMO

Anomalous origin of the right coronary artery from the left sinus of Valsalva has a very low prevalence in the general population. Although the vast majority of patients are asymptomatic, the clinical consequence of this heart disorder can be sudden death. In many of these sudden death cases the right coronary artery is running between the anterior aspect of the aorta and behind the common trunk of the pulmonary artery, where systolic compression may have an impact on myocardial perfusion. Asymptomatic patients with this malignant course present the surgeon with a difficult decision, and they should be carefully evaluated in order to facilitate a tailored surgical approach.  In this video tutorial we present a patient with this anomalous course of the right coronary artery, which was documented by coronary computed tomography angiography using a 3D reconstruction. The patient received an off-pump coronary artery bypass graft using an original surgical technique that prevents any type of flow competition. The case had an excellent final outcome, with good results at follow-up.  Finally, a systematic review of the literature with a discussion of the different treatment modalities is provided.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Anomalias dos Vasos Coronários/cirurgia , Seio Aórtico/anormalidades , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Adulto Jovem
20.
Front Cardiovasc Med ; 5: 118, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30234129

RESUMO

Tricuspid valve disease affects millions of patients worldwide. It has always been considered less relevant than the left-side valves of the heart, but this "forgotten valve" still represents a great challenge for the cardiac surgeons, especially in the most difficult symptomatic scenarios. In this review we analyze the wide spectrum of surgical techniques for the treatment of a diseased tricuspid valve.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA