Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Resuscitation ; 194: 109999, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37838142

RESUMO

INTRODUCTION: Bag-Valve-Device (BVD) is the most frequently used device for pre-oxygenation and ventilation during cardiopulmonary resuscitation (CPR). A minimal expired fraction of oxygen (FeO2) above 0.85 is recommended during pre-oxygenation while insufflated volume (VTi) should be reduced during manual ventilation. The objective was to compare the performances of different BVD in simulated conditions. METHODS: Nine BVD were evaluated during pre-oxygenation: spontaneous breathing patients were simulated on a test lung (mild and severe conditions). FeO2 was measured with and without positive end-expiratory pressure (PEEP). CO2 rebreathing was evaluated. Then, manual ventilation was performed by 36 caregivers (n = 36) from three hospitals on a specific manikin; same procedure was repeated by 3 caregivers (n = 3) on two human cadavers with three of the nine BVD: In non-CPR scenario and during mechanical CPR with Interrupted Chest Compressions strategy (30:2). RESULTS: Pre-oxygenation: FeO2 was lower than 0.85 for three BVD in severe condition and for two BVD in mild condition. FeO2 was higher than 0.85 in eight of nine BVD with an additional PEEP valve (PEEP 5 cmH2O). One BVD induced CO2 rebreathing. Manual ventilation: For non-CPR manual ventilation, mean VTi was within the predefined lung protective range (4-8 mL/kg PBW) for all BVD on the bench. For CPR manual ventilation, mean VTi was above the range for three BVD on the bench. Similar results were observed on cadavers. CONCLUSIONS: Several BVD did not reach the FeO2 required during pre-oxygenation. Manual ventilation was significantly less protective in three BVD. These observations are related to the different BVD working principles.


Assuntos
Reanimação Cardiopulmonar , Humanos , Reanimação Cardiopulmonar/métodos , Dióxido de Carbono , Respiração Artificial/métodos , Pulmão , Cadáver
2.
Forensic Sci Int ; 316: 110541, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33096455

RESUMO

Over the past twenty years, psychotropic drug abuse by young people, especially by teenagers, has received special attention. Here, we present the case of baclofen overdose in a 16-year-old male who recreationally, and probably recurrently, self-administered baclofen. In addition, a review of other cases was conducted. The 16-year-old boy presented to emergency department with digestive signs followed by agitated confusion. Detection and determination of baclofen concentration were achieved using liquid chromatography tandem mass spectrometry. Baclofen was detected in plasma and urine, at 420 ng/mL and 64 900 ng/mL respectively. Further, an English exhaustive literature search was performed using several different scientific databases without any limiting period in order to identify scientific articles dealing with baclofen overdose following a recreational use among adolescent and young adults. Five publications describing baclofen overdoses following a recreational use among adolescents and young adults have been published reporting19 cases, all involving a non-fatal overdose, with baclofen concentrations ranging from less than 20-1322 ng/mL. Baclofen is a psychotropic drug and its recreational use among adolescents and young adults represent a serious problem and should be considered by healthcare professionals. Among young people, baclofen poisoning remains relatively infrequent or most likely underestimated and these observations highlight the importance of constructive communication and joining efforts of clinicians and analytical toxicologists.


Assuntos
Baclofeno/efeitos adversos , Overdose de Drogas , Agonistas dos Receptores de GABA-B/efeitos adversos , Transtornos Relacionados ao Uso de Substâncias/complicações , Adolescente , Baclofeno/sangue , Baclofeno/urina , Cromatografia Líquida , Agonistas dos Receptores de GABA-B/sangue , Agonistas dos Receptores de GABA-B/urina , Humanos , Masculino , Uso Indevido de Medicamentos sob Prescrição , Transtornos Relacionados ao Uso de Substâncias/diagnóstico , Espectrometria de Massas em Tandem
3.
Ann Intensive Care ; 10(1): 138, 2020 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-33052476

RESUMO

BACKGROUND: Persistent swallowing disorders (SD) are non-pulmonary complications of mechanical ventilation (MV). However, there are few clinical studies on persistent SD in critically ill patients undergoing tracheal intubation for MV. The aim of the present study was to assess the incidence and characteristics of clinical manifestations associated with persistent SD. METHODS: We prospectively evaluated in patients requiring more than 7 days of invasive MV the incidence and characteristics of clinical manifestations related to persistent SD. For this purpose, quality of swallowing was assessed within 24 h after extubation by an experienced physical therapist not directly involved in patient management. Swallowing assessment consisted in a specific standardized test combining a swallowing test and a full clinical evaluation of the cranial nerves involved in swallowing. In patients with SD on the first test, a second test was done within 48 h in order to discriminate between transient and persistent SD. RESULTS: Among the 482 patients mechanically ventilated more than 7 days, 138 were enrolled in this study. The first test performed 24 h after extubation revealed SD in 35 patients (25%). According to the second test performed 48 h later, SD were considered transient in 21 (15%) and persistent in 14 (10%) cases. Patients with persistent SD were older (66 ± 16 vs 58 ± 15 years), had lower bodyweight at admission (76 ± 15 vs 87 ± 23 kg) and received less often neuromuscular blocking agents (36% vs 66%) compared to patients without or with only transient SD. Patients with persistent SD had longer duration of Intensive Care Unit (ICU) stay after first extubation and longer delay to oral feeding than patients without or with only transient SD, respectively, 11 ± 9 vs 7 ± 6 days and 23 ± 33 vs 5 ± 7 days. CONCLUSIONS: Based on a specific standardized clinical test, 25% of patients mechanically ventilated more than 7 days exhibited clinical manifestations of SD. However, SD were considered as persistent after extubation in only 10% of them. Persistent SD were associated with longer duration of ICU stay after extubation and longer time of enteral feeding. TRIAL REGISTRATION: The study is registered with Clinical Trials (NCT01360580).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA