Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Med Phys ; 49(9): 6098-6109, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35754208

RESUMO

PURPOSE: We assessed whether adding sodium borocaptate (BSH) or 4-borono-l-phenylalanine (BPA) to cells irradiated with proton beams influenced the biological effectiveness of those beams against prostate cancer cells to investigate if the alpha particles generated through proton-boron nuclear reactions would be sufficient to enhance the biological effectiveness of the proton beams. METHODS: We measured clonogenic survival in DU145 cells treated with 80.4-ppm BSH or 86.9-ppm BPA, or their respective vehicles, after irradiation with 6-MV X-rays, 1.2-keV/µm (low linear energy transfer [LET]) protons, or 9.9-keV/µm (high-LET) protons. We also measured γH2AX and 53BP1 foci in treated cells at 1 and 24 h after irradiation with the same conditions. RESULTS: We found that BSH radiosensitized DU145 cells across all radiation types. However, no difference was found in relative radiosensitization, characterized by the sensitization enhancement ratio or the relative biological effectiveness, for vehicle- versus BSH-treated cells. No differences were found in numbers of γH2AX or 53BP1 foci or γH2AX/53BP1 colocalized foci for vehicle- versus BSH-treated cells across radiation types. BPA did not radiosensitize DU145 cells nor induced any significant differences when comparing vehicle- versus BPA-treated cells for clonogenic cell survival or γH2AX and 53BP1 foci or γH2AX/53BP1 colocalized foci. CONCLUSIONS: Treatment with 11 B, at concentrations of 80.4 ppm from BSH or 86.9 ppm from BPA, had no effect on the biological effectiveness of proton beams in DU145 prostate cancer cells. Our results agree with published theoretical calculations indicating that the contribution of alpha particles from such reactions to the total absorbed dose and biological effectiveness is negligible. We also found that BSH radiosensitized DU145 cells to X-rays, low-LET protons, and high-LET protons but that the radiosensitization was not related to DNA damage.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias da Próstata , Terapia com Prótons , Compostos de Boro/farmacologia , Compostos de Boro/uso terapêutico , Humanos , Masculino , Fenilalanina/farmacologia , Fenilalanina/uso terapêutico , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Prótons , Eficiência Biológica Relativa
2.
Int J Radiat Biol ; 98(1): 50-59, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34705615

RESUMO

PURPOSE: Even though X-ray beams are widely used in medical diagnosis or radiotherapy, the comparisons of their dose rates are scarce. We have recently demonstrated in vitro (clonogenic assay, cell viability, cell cycle, senescence) and in vivo (weight follow-up of animals and bordering epithelium staining of lesion), that for a single dose of irradiation, the relative biological effectiveness (RBE) deviates from 1 (up to twofold greater severe damage at the highest dose rate depending on the assay) when increasing the dose rate of high energy X-ray beams. MATERIAL AND METHODS: To further investigate the impact of the dose rate on RBE, in this study, we performed in vitro fractionated irradiations by using the same two dose rates (0.63 and 2.5 Gy.min-1) of high-energy X-rays (both at 4 MV) on normal endothelial cells (HUVECs). We investigated the viability/mortality, characterized radiation-induced senescence by using flow cytometry and measured gene analysis deregulations on custom arrays. RESULTS: The overall results enlighten that, in fractionated irradiations when varying the dose rate of high-energy X-rays, the RBE of photons deviates from 1 (up to 2.86 for viability/mortality experiments performed 21 days postirradiation). CONCLUSION: These results strengthen the interest of multiparametric analysis approaches in providing an accurate evaluation of the outcomes of irradiated cells in support of clonogenic assays, especially when such assays are not feasible.


Assuntos
Células Endoteliais , Animais , Sobrevivência Celular/efeitos da radiação , Relação Dose-Resposta à Radiação , Eficiência Biológica Relativa , Raios X
3.
Med Phys ; 49(9): 6221-6236, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35831779

RESUMO

BACKGROUND: Proton relative biological effectiveness (RBE) is known to depend on physical factors of the proton beam, such as its linear energy transfer (LET), as well as on cell-line specific biological factors, such as their ability to repair DNA damage. However, in a clinical setting, proton RBE is still considered to have a fixed value of 1.1 despite the existence of several empirical models that can predict proton RBE based on how a cell's survival curve (linear-quadratic model [LQM]) parameters α and ß vary with the LET of the proton beam. Part of the hesitation to incorporate variable RBE models in the clinic is due to the great noise in the biological datasets on which these models are trained, often making it unclear which model, if any, provides sufficiently accurate RBE predictions to warrant a departure from RBE = 1.1. PURPOSE: Here, we introduce a novel model of proton RBE based on how a cell's intrinsic radiosensitivity varies with LET, rather than its LQM parameters. METHODS AND MATERIALS: We performed clonogenic cell survival assays for eight cell lines exposed to 6 MV x-rays and 1.2, 2.6, or 9.9 keV/µm protons, and combined our measurements with published survival data (n = 397 total cell line/LET combinations). We characterized how radiosensitivity metrics of the form DSF% , (the dose required to achieve survival fraction [SF], e.g., D10% ) varied with proton LET, and calculated the Bayesian information criteria associated with different LET-dependent functions to determine which functions best described the underlying trends. This allowed us to construct a six-parameter model that predicts cells' proton survival curves based on the LET dependence of their radiosensitivity, rather than the LET dependence of the LQM parameters themselves. We compared the accuracy of our model to previously established empirical proton RBE models, and implemented our model within a clinical treatment plan evaluation workflow to demonstrate its feasibility in a clinical setting. RESULTS: Our analyses of the trends in the data show that DSF% is linearly correlated between x-rays and protons, regardless of the choice of the survival level (e.g., D10% , D37% , or D50% are similarly correlated), and that the slope and intercept of these correlations vary with proton LET. The model we constructed based on these trends predicts proton RBE within 15%-30% at the 68.3% confidence level and offers a more accurate general description of the experimental data than previously published empirical models. In the context of a clinical treatment plan, our model generally predicted higher RBE-weighted doses than the other empirical models, with RBE-weighted doses in the distal portion of the field being up to 50.7% higher than the planned RBE-weighted doses (RBE = 1.1) to the tumor. CONCLUSIONS: We established a new empirical proton RBE model that is more accurate than previous empirical models, and that predicts much higher RBE values in the distal edge of clinical proton beams.


Assuntos
Terapia com Prótons , Prótons , Teorema de Bayes , Terapia com Prótons/métodos , Tolerância a Radiação , Eficiência Biológica Relativa , Raios X
4.
Radiat Res ; 198(4): 336-346, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35939823

RESUMO

Small molecule inhibitors are currently in preclinical and clinical development for the treatment of selected cancers, particularly those with existing genetic alterations in DNA repair and DNA damage response (DDR) pathways. Keen interest has also been expressed in combining such agents with other targeted antitumor strategies such as radiotherapy. Radiotherapy exerts its cytotoxic effects primarily through DNA damage-induced cell death; therefore, inhibiting DNA repair and the DDR should lead to additive and/or synergistic radiosensitizing effects. In this study we screened the response to X-ray or proton radiation in cell lines treated with DDR inhibitors (DDRis) targeting ATM, ATR, DNA-PKcs, Rad51, and PARP, with survival metrics established using clonogenic assays. We observed that DDRis generate significant radiosensitization in cancer and primary cells derived from normal tissue. Existing genetic defects in cancer cells appear to be an important consideration when determining the optimal inhibitor to use for synergistic combination with radiation. We also show that while greater radiosensitization can be achieved with protons (9.9 keV/µm) combined with DDRis, the relative biological effectiveness is unchanged or in some cases reduced. Our results indicate that while targeting the DDR can significantly radiosensitize cancer cells to such combinations, normal cells may also be equally or more severely affected, depending on the DDRi used. These data highlight the importance of identifying genetic defects as predictive biomarkers of response for combination treatment.


Assuntos
Neoplasias , Radiossensibilizantes , Proteínas Mutadas de Ataxia Telangiectasia/metabolismo , DNA , Dano ao DNA , Reparo do DNA , Humanos , Neoplasias/tratamento farmacológico , Inibidores de Poli(ADP-Ribose) Polimerases/farmacologia , Inibidores de Poli(ADP-Ribose) Polimerases/uso terapêutico , Prótons , Rad51 Recombinase/metabolismo , Radiossensibilizantes/farmacologia , Raios X
5.
Sci Rep ; 9(1): 14328, 2019 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-31586152

RESUMO

Based on classic clonogenic assay, it is accepted by the scientific community that, whatever the energy, the relative biological effectiveness of X-rays is equal to 1. However, although X-ray beams are widely used in diagnosis, interventional medicine and radiotherapy, comparisons of their energies are scarce. We therefore assessed in vitro the effects of low- and high-energy X-rays using Human umbilical vein endothelial cells (HUVECs) by performing clonogenic assay, measuring viability/mortality, counting γ-H2AX foci, studying cell proliferation and cellular senescence by flow cytometry and by performing gene analysis on custom arrays. Taken together, excepted for γ-H2AX foci counts, these experiments systematically show more adverse effects of high energy X-rays, while the relative biological effectiveness of photons is around 1, whatever the quality of the X-ray beam. These results strongly suggest that multiparametric analysis should be considered in support of clonogenic assay.


Assuntos
Histonas/efeitos da radiação , Fótons/efeitos adversos , Eficiência Biológica Relativa , Raios X/efeitos adversos , Sobrevivência Celular/efeitos da radiação , Ensaio de Unidades Formadoras de Colônias , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Marcadores Genéticos/efeitos da radiação , Histonas/genética , Células Endoteliais da Veia Umbilical Humana , Humanos , Transferência Linear de Energia , Estudo de Prova de Conceito
6.
Int J Radiat Biol ; 94(6): 597-606, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29701998

RESUMO

PURPOSE: The main objective of radiobiology is to establish links between doses and radiation-induced biological effects. In this context, well-defined dosimetry protocols are crucial to the determination of experimental protocols. This work proposes a new dosimetry protocol for cell irradiation in a SARRP and shows the importance of the modification of some parameters defined in dosimetry protocol for physical dose and biological outcomes. MATERIALS AND METHODS: Once all parameters of the configuration were defined, dosimetry measurements with ionization chambers and EBT3 films were performed to evaluate the dose rate and the attenuation due to the cell culture medium. To evaluate the influence of changes in cell culture volume and/or additional filtration, 6-well plates containing EBT3 films with water were used to determine the impact on the physical dose at 80 kV. Then, experiments with the same irradiation conditions were performed by replacing EBT3 films by HUVECs. The biological response was assessed using clonogenic assay. RESULTS: Using a 0.15 mm copper filter lead to a variation of +1% using medium thickness of 0.104 cm to -8% using a medium thickness of 0.936 cm on the physical dose compare to the reference condition (0.313 cm). For the 1 mm aluminum filter, a variation of +8 to -40% for the same medium thickness conditions has been observed. Cells irradiated in the same conditions showed significant differences in survival fraction, corroborating the effects of dosimetric changes on physical dose. CONCLUSIONS: This work shows the importance of dosimetry in radiobiology studies and the need of an accurate description of the dosimetry protocol used for irradiation.


Assuntos
Radiometria/instrumentação , Desenho de Equipamento , Células Endoteliais da Veia Umbilical Humana/citologia , Células Endoteliais da Veia Umbilical Humana/efeitos da radiação , Humanos , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA