Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 30(9): 1386-1392, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31155497

RESUMO

PURPOSE: To quantify the displacement of the vascular structures after insertion of stiff devices during endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm and to identify potential parameters influencing this displacement. MATERIALS AND METHODS: A total of 50 patients from a single center undergoing EVAR were prospectively enrolled between January 2016 and December 2017. Fusion imaging was employed using the EndoNaut (Therenva, Rennnes, France) station through a 3-dimensional (3D)/2-dimensional (2D) technology synchronizing the 3D computed tomography scan to the live intraoperative fluoroscopy. The accuracy of the fusion roadmap was evaluated before deployment by conventional digital subtraction angiogram on a single plane (with different C-arm incidences). RESULTS: The mean displacement error of the ostium of the lowest renal artery was 4.1 ± 2.4 mm (range, 0-11.7 mm), with a left/right displacement of 1.6 ± 1.7 mm (range, 0-6.9 mm) and a craniocaudal displacement of 3.5 ± 2.4 mm (range, 0-11.3 mm). The correction required for the ostium of the lower renal artery was mostly cranial and to the left. Multiple linear regression analysis revealed only the sharpest angle between the aneurysm neck and sac as the factor influencing the accuracy of fusion imaging. All other parameters did not show any correlation. CONCLUSIONS: This study identified the sources of fusion error after insertion of rigid material during EVAR. As the sharpest angulation between aneurysm neck and sac increases, the overall accuracy of the fusion might be affected.


Assuntos
Angiografia Digital , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA