Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Ann Biomed Eng ; 52(10): 2872-2883, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38910203

RESUMO

Instrumented mouthguard systems (iMGs) are commonly used to study rigid body head kinematics across a variety of athletic environments. Previous work has found good fidelity for iMGs rigidly fixed to anthropomorphic test device (ATD) headforms when compared to reference systems, but few validation studies have focused on iMG performance in human cadaver heads. Here, we examine the performance of two boil-and-bite style iMGs in helmeted cadaver heads. Three unembalmed human cadaver heads were fitted with two instrumented boil-and-bite mouthguards [Prevent Biometrics and Diversified Technical Systems (DTS)] per manufacturer instructions. Reference sensors were rigidly fixed to each specimen. Specimens were fitted with a Riddell SpeedFlex American football helmet and impacted with a rigid impactor at three velocities and locations. All impact kinematics were compared at the head center of gravity. The Prevent iMG performed comparably to the reference system up to ~ 60 g in linear acceleration, but overall had poor correlation (CCC = 0.39). Prevent iMG angular velocity and BrIC generally well correlated with the reference, while underestimating HIC and overestimating HIC duration. The DTS iMG consistently overestimated the reference across all measures, with linear acceleration error ranging from 10 to 66%, and angular acceleration errors greater than 300%. Neither iMG demonstrated consistent agreement with the reference system. While iMG validation efforts have utilized ATD testing, this study highlights the need for cadaver testing and validation of devices intended for use in-vivo, particularly when considering realistic (non-idealized) sensor-skull coupling, when accounting for interactions with the mandible and when subject-specific anatomy may affect device performance.


Assuntos
Cabeça , Protetores Bucais , Humanos , Fenômenos Biomecânicos , Cabeça/fisiologia , Cadáver , Dispositivos de Proteção da Cabeça , Aceleração , Masculino , Desenho de Equipamento
2.
Ann Biomed Eng ; 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39028399

RESUMO

PURPOSE: Measuring head kinematics data is important to understand and develop methods and standards to mitigate head injuries in contact sports. Instrumented mouthguards (iMGs) have been developed to address coupling issues with previous sensors. Although validated with anthropomorphic test devices (ATDs), there is limited post-mortem human subjects (PMHS) data which provides more accurate soft tissue responses. This study evaluated two iMGs (Prevent Biometrics (PRE) and Diversified Technical Systems (DTS) in response to direct jaw impacts. METHODS: Three unembalmed male cadaver heads were properly fitted with two different boil-and-bite iMGs and impacted with hook (4 m/s) and uppercut (3 m/s) punches. A reference sensor (REF) was rigidly attached to the base of the skull, impact kinematics were transformed to the head center of gravity and linear and angular kinematic data were compared to the iMGs including Peak Linear Acceleration, Peak Angular Acceleration, Peak Angular Velocity, Head Injury Criterion (HIC), HIC duration, and Brain Injury Criterion. RESULTS: Compared to the REF sensor, the PRE iMG underpredicted most of the kinematic data with slopes of the validation regression line between 0.72 and 1.04 and the DTS overpredicted all the kinematic data with slopes of the regression line between 1.4 and 8.7. CONCLUSION: While the PRE iMG was closer to the REF sensor compared to the DTS iMG, the results did not support the previous findings reported with use of ATDs. Hence, our study highlights the benefits of using PMHS for validating the accuracy of iMGs since they closely mimic the human body compared to any ATD's mandible.

3.
Traffic Inj Prev ; 23(sup1): S38-S43, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35939323

RESUMO

OBJECTIVE: The objective of this study was to utilize an instrumented mouthpiece sensor to characterize head kinematics experienced by grassroots dirt track race car drivers. METHODS: Four dirt track race car drivers (ages 16-19) were instrumented with custom mouthpiece sensors capable of accurately measuring head motion during racing. Sensors were deployed before races and recorded tri-axial linear acceleration and rotational velocity for approximately 10 min at 200 Hz. Film review was performed to identify data associated with racing laps. For each lap, moving average kinematics were computed and subtracted from the head motion signals to obtain 'adjusted' head motion accounting for lower frequency variance due to periodic motion around the track. From adjusted data, linear and angular head perturbations (i.e., deviations from moving average) were extracted using a custom algorithm. RESULTS: Data was collected during 400 driver-races. A total of 2438 laps were segmented from mouthpiece recordings. The median (95th percentile) peak linear acceleration, rotational velocity, and rotational acceleration of all laps were 5.33 (8.28) g, 2.89 (4.60) rad/s, and 179 (310) rad/s2, respectively. Angular perturbations occurred most frequently about the anterior-posterior axis (median lap frequency = 6.39 Hz); whereas linear perturbations occurred most frequently in the inferior-superior direction (7.96 Hz). Nine crash events were recorded by the mouthpiece sensors. The median (95th percentile) peak head kinematics of these events were 13.4 (36.6) g, 9.67 (21.9) rad/s, and 630 (1330) rad/s2. CONCLUSIONS: Mouthpiece sensors can be used to measure head kinematics during active racing. Laps, head perturbations, and crashes may be useful units of observation to describe typical head kinematic exposure experienced by drivers while racing. Subsequent research is needed to understand the associations between repetitive racing exposure and neurological function. Higher magnitude events (i.e., crashes) are not uncommon and may result in concussion or more severe injury. Results represent novel characterizations of head kinematic exposure experienced in a dirt track racing environment. This information may inform evidence-based strategies (e.g., vehicle/seat design) to improve driver safety.


Assuntos
Acidentes de Trânsito , Concussão Encefálica , Humanos , Adolescente , Adulto Jovem , Adulto , Fenômenos Biomecânicos , Aceleração , Cabeça
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA