Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Medicina (Kaunas) ; 59(2)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36837541

RESUMO

Background and Objectives: The SARS-CoV-2 infection brings supplemental risks for pregnant women. Due to controversial hesitancy, their vaccination rate was lower in 2021 compared to the general population. In addition, access to maternal care was reduced during the pandemic. We conducted a retrospective cross-sectional analysis of the health records data over 20 months (1 April 2020 to 20 November 2021) aiming to explore the outcomes in SARS-CoV-2-positive cases referred for delivery to a tertiary public hospital in Western Romania. Materials and Methods: Women with SARS-CoV-2 infection diagnosed for the first time at the moment of birth who delivered singletons after 24 weeks of gestation, and had a clear immunization status were included in the analysis. Results: Out of the 97 patients included in the study, 35 (36%) had undergone ARN-based vaccination. Five cases of maternal death were recorded (all unvaccinated). Our retrospective exploratory analysis showed that the presence of COVID-19 symptoms in the SARS-CoV-2-positive patients made a significant impact on the delivery hospitalization, with a median hospital stay increase from 5 to 9 days (Mann-Whitney test, p = 0.014): longer hospitalization was recorded in the symptomatic cases irrespective of their vaccination status. No other adverse outcomes, such as gestational age at delivery, C-section rate, 5 min Apgar index, or birth weight were associated with the presence of symptoms. Conclusions: Our clinic maintained safe maternal care for the COVID-19 patients during the analyzed period. Vaccination of the expectant women was beneficial in SARS-CoV-2-positive patients by lowering the risk of COVID-19 symptoms, with subsequent implications on the newborns' health and maternal attachment.


Assuntos
COVID-19 , Complicações Infecciosas na Gravidez , Humanos , Gravidez , Feminino , Recém-Nascido , Resultado da Gravidez/epidemiologia , COVID-19/epidemiologia , SARS-CoV-2 , Estudos Retrospectivos , Complicações Infecciosas na Gravidez/epidemiologia , Estudos Transversais
2.
Molecules ; 24(13)2019 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-31324029

RESUMO

The present study investigated the possibilities and feasibility of drug targeting for an arterial bifurcation lesion to influence the host healing response. A micrometer sized iron particle was used only to model the magnetic carrier in the experimental investigation (not intended for clinical use), to demonstrate the feasibility of the particle targeting at the lesion site and facilitate the new experimental investigations using coated superparamagnetic iron oxide nanoparticles. Magnetic fields were generated by a single permanent external magnet (ferrite magnet). Artery bifurcation exerts severe impacts on drug distribution, both in the main vessel and the branches, practically inducing an uneven drug concentration distribution in the bifurcation lesion area. There are permanently positioned magnets in the vicinity of the bifurcation near the diseased area. The generated magnetic field induced deviation of the injected ferromagnetic particles and were captured onto the vessel wall of the test section. To increase the particle accumulation in the targeted region and consequently avoid the polypharmacology (interaction of the injected drug particles with multiple target sites), it is critical to understand flow hemodynamics and the correlation between flow structure, magnetic field gradient, and spatial position.


Assuntos
Artérias/fisiopatologia , Artérias/efeitos da radiação , Sistemas de Liberação de Medicamentos , Hemodinâmica/efeitos da radiação , Campos Magnéticos , Nanopartículas de Magnetita , Nanomedicina Teranóstica , Algoritmos , Angiografia , Artérias/anormalidades , Artérias/diagnóstico por imagem , Substitutos Sanguíneos , Hemodinâmica/efeitos dos fármacos , Modelos Biológicos , Tamanho da Partícula , Reologia
3.
Diagnostics (Basel) ; 14(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38396408

RESUMO

Diabetes mellitus during pregnancy and gestational diabetes are major concerns worldwide. These conditions may lead to the development of severe diabetic retinopathy during pregnancy or worsen pre-existing cases. Gestational diabetes also increases the risk of diabetes for both the mother and the fetus in the future. Understanding the prevalence, evaluating risk factors contributing to pathogenesis, and identifying treatment challenges related to diabetic retinopathy in expectant mothers are all of utmost importance. Pregnancy-related physiological changes, including those in metabolism, blood flow, immunity, and hormones, can contribute to the development or worsening of diabetic retinopathy. If left untreated, this condition may eventually result in irreversible vision loss. Treatment options such as laser therapy, intravitreal anti-vascular endothelial growth factor drugs, and intravitreal steroids pose challenges in managing these patients without endangering the developing baby and mother. This narrative review describes the management of diabetic retinopathy during pregnancy, highlights its risk factors, pathophysiology, and diagnostic methods, and offers recommendations based on findings from previous literature.

4.
Pharmaceutics ; 15(11)2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38004590

RESUMO

This research aims to investigate the agglomeration processes of magnetoresponsive functionalized nanocluster suspensions in a magnetic field, as well as how these structures impact the behaviour of these suspensions in biomedical applications. The synthesis, shape, colloidal stability, and magnetic characteristics of PEG-functionalized nanoclusters are described in this paper. Experiments using TEM, XPS, dynamic light scattering (DLS), VSM, and optical microscopy were performed to study chain-like agglomeration production and its influence on colloidal behaviour in physiologically relevant suspensions. The applied magnetic field aligns the magnetic moments of the nanoclusters. It provides an attraction between neighbouring particles, resulting in the formation of chains, linear aggregates, or agglomerates of clusters aligned along the applied field direction. Optical microscopy has been used to observe the creation of these aligned linear formations. The design of chain-like structures can cause considerable changes in the characteristics of ferrofluids, ranging from rheological differences to colloidal stability changes.

5.
Diagnostics (Basel) ; 13(2)2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36673058

RESUMO

Severe acute respiratory syndrome virus 2 (SARS-CoV-2), the virus that causes 2019 coronavirus disease (COVID-19), has been isolated from various tissues and body fluids, including the placenta, amniotic fluid, and umbilical cord of newborns. In the last few years, much scientific effort has been directed toward studying SARS-CoV-2, focusing on the different features of the virus, such as its structure and mechanisms of action. Moreover, much focus has been on developing accurate diagnostic tools and various drugs or vaccines to treat COVID-19. However, the available evidence is still scarce and consistent criteria should be used for diagnosing vertical transmission. Applying the PRISMA ScR guidelines, we conducted a scoping review with the primary objective of identifying the types, and examining the range, of available evidence of vertical transmission of SARS-CoV-2 from mother to newborn. We also aimed to clarify the key concepts and criteria for diagnosis of SARS-CoV-2 vertical infection in neonates and summarize the existing evidence and advance the awareness of SARS-CoV-2 vertical infection in pregnancy. Most studies we identified were case reports or case series (about 30% of poor quality and inconsistent reporting of the findings). Summarizing the existing classification criteria, we propose an algorithm for consistent diagnosis. Registration: INPLASY2022120093.

6.
Viruses ; 15(7)2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37515301

RESUMO

OBJECTIVES: To determine risk factors for primary and secondary adverse neonatal outcomes in newborns with congenital SARS-CoV-2 infection. DATA SOURCES: PubMed/MEDLINE and Google Scholar from January 2020 to January 2022. STUDY ELIGIBILITY CRITERIA: newborns delivered after 24 weeks of gestation with confirmed/possible congenital SARS-CoV-2 infection, according to standard classification criteria. METHODS: Execution of the IPD analyses followed the PRISMA-IPD statement. Univariate non-parametric tests compared numerical data distributions. Fisher's exact or Chi-square test determined categorical variables' statistical significance. Multivariate logistic regression revealed risk factors for adverse neonatal outcome. RESULTS: Maternal fever was associated with symptomatic congenital infection (OR: 4.55, 95% CI: 1.33-15.57). Two-thirds of women that reported decreased fetal movements were diagnosed with IUFD (p-value = 0.001). Reduced fetal movement increased the risk of intrauterine fetal death by 7.84 times (p-value = 0.016, 95% CI: 2.23-27.5). The risk of stillbirth decreased with gestational age at the time of maternal infection (p-value < 0.05, OR: 0.87, 95% CI: 0.79-0.97). CONCLUSIONS: Maternal fever and perception of reduced fetal movement may be predictive risk factors for adverse pregnancy outcome in cases with congenital SARS-CoV-2 infection.


Assuntos
COVID-19 , Complicações Infecciosas na Gravidez , Gravidez , Humanos , Recém-Nascido , Feminino , Movimento Fetal , Complicações Infecciosas na Gravidez/diagnóstico , SARS-CoV-2 , Natimorto/epidemiologia , Fatores de Risco , Transmissão Vertical de Doenças Infecciosas
7.
Pharmaceutics ; 14(9)2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36145671

RESUMO

Drug therapy for vascular disease has been promoted to inhibit angiogenesis in atherosclerotic plaques and prevent restenosis following surgical intervention. This paper investigates the arterial depositions and distribution of PEG-functionalized magnetic nanocomposite clusters (PEG_MNCs) following local delivery in a stented artery model in a uniform magnetic field produced by a regionally positioned external permanent magnet; also, the PEG_MNCs aggregation or chain formation in and around the implanted stent. The central concept is to employ one external permanent magnet system, which produces enough magnetic field to magnetize and guide the magnetic nanoclusters in the stented artery region. At room temperature (25 °C), optical microscopy of the suspension model's aggregation process was carried out in the external magnetic field. According to the optical microscopy pictures, the PEG_MNC particles form long linear aggregates due to dipolar magnetic interactions when there is an external magnetic field. During magnetic particle targeting, 20 mL of the model suspensions are injected (at a constant flow rate of 39.6 mL/min for the period of 30 s) by the syringe pump in the mean flow (flow velocity is Um = 0.25 m/s, corresponding to the Reynolds number of Re = 232) into the stented artery model. The PEG_MNC clusters are attracted by the magnetic forces (generated by the permanent external magnet) and captured around the stent struts and the bottom artery wall before and inside the implanted stent. The colloidal interaction among the MNC clusters was investigated by calculating the electrostatic repulsion, van der Waals and magnetic dipole-dipole energies. The current work offers essential details about PEG_MNCs aggregation and chain structure development in the presence of an external magnetic field and the process underlying this structure formation.

8.
Biomed Mater Eng ; 26 Suppl 1: S477-86, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26406039

RESUMO

Optimal graft design has been an objective of many researchers to find correlations between hemodynamics and graft failure. Compared to planar grafts, the helical graft configurations improve hemodynamic performance including the promotion of flow mixing and reduction of flow stagnation regions. In order to evaluate the advantages and disadvantages of the suggested helical type bypass graft model in comparison to a conventional bypass graft configuration, three experimental models were designed and evaluated. The character of complex vortex structures created in the area between the heel and the occluded section depends on the flow parameters (in the case of the straight graft). We have identified two vortices in the symmetrical plane (proximal and distal to the anastomosis). In the new design of the two-turn helical graft, the stagnation point is eliminated from the anastomoses at different time intervals compared to the conventional straight bypass model The present study indicated that the magnitude of the pressure drop along a helical graft was considerably increased compared to a traditional graft which, while still physiologically advantageous, can be surpassed by an optimal geometry model.


Assuntos
Prótese Vascular , Ponte de Artéria Coronária/instrumentação , Ponte de Artéria Coronária/métodos , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Circulação Coronária , Análise de Falha de Equipamento , Humanos , Desenho de Prótese , Resultado do Tratamento
9.
Biomed Mater Eng ; 24(1): 323-34, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24211913

RESUMO

In this study, effects of serial stenosis on coronary hemodynamics were investigated in the human right coronary artery (RCA) using blood flow analysis. A 3-D model of a serial stenosed RCA was reconstructed based on multislice computerized tomography images. Numerical analysis examined the effect of multiple serial stenoses on the hemodynamic characteristics such as flow separation, pressure drop and FFR. Pressure loss associated with flow expansion after each constriction was large. Overall pressure drop increased from 1700 Pa (12.75 mmHg) at the end diastole to 11000 Pa (82.5 mmHg) at the peak systole. In two stenoses the corresponding pressure gradients werearound 30 mmHg and corresponded to the stenosis with FFR < 0.7 (associated to the sever stenosis). Severe stenosies caused large pressure drops across the throat. Blood flow distal to the stenosis was associated with fluctuations of the wall shear stress and vorticity.


Assuntos
Estenose Coronária/diagnóstico , Vasos Coronários/patologia , Hemodinâmica , Adulto , Angiografia , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco , Estenose Coronária/patologia , Humanos , Hidrodinâmica , Hipertensão/patologia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Modelos Cardiovasculares , Pressão , Interpretação de Imagem Radiográfica Assistida por Computador , Resistência ao Cisalhamento , Estresse Mecânico , Tomografia Computadorizada por Raios X
10.
Biomed Mater Eng ; 24(1): 853-60, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24211972

RESUMO

The long-term success of arterial bypass surgery is often limited by the progression of intimal hyperplasia at the anastomosis between the graft and the native artery. The experimental models were manufactured from glass tubing with constant internal diameter of 8 mm, fashioned into a straight configuration and helical configuration. The aim of this study was to determine the three-dimensional flow structures that occur at the proximal anastomosis under pulsatile flow conditions, to investigate the changes that resulted from variations in the anastomosis angle and flow division, and to establishing the major differences between the straight and helical graft. In the anastomosis domain, a strong region of recirculation is observed near the occluded end of the artery, which forces the flow to move into the perfused host coronary artery. The proximal portion of the host tube shows weak counter-rotating vortices on the symmetry plane. The exact locations and strengths of the vortices in this region are only weakly dependent on Re. A detailed comparison of experimentally measured axial velocity patterns for straight and helical grafts confirm the very strong nature of the secondary flows in the helical geometry. The helical configuration promotes the mixing effect of vortex motion such that the flow particles are mixed into the blood stream disal to the anastomotic junction.


Assuntos
Anastomose Cirúrgica/métodos , Prótese Vascular , Ponte de Artéria Coronária/métodos , Reologia , Coagulação Sanguínea , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Desenho de Equipamento , Vidro , Hemodinâmica , Humanos , Hidrodinâmica , Modelos Cardiovasculares , Fluxo Pulsátil , Resistência ao Cisalhamento , Túnica Íntima/patologia , Enxerto Vascular/métodos
11.
J Clin Med Res ; 4(3): 177-89, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22719804

RESUMO

BACKGROUND: Blood flow analysis of the human right coronary artery (RCA) has been carried out to investigate the effects of serial stenosis on coronary hemodynamics. A 3-D model of a serial stenosed RCA was reconstructed based on multislice computerized tomography images. METHODS: A velocity waveform in the proximal RCA and a pressure waveform in the distal RCA of a patient with a severe stenosis were acquired with a catheter delivered wire probe and applied as boundary conditions. The numerical analysis examines closely the effect of a multiple serial stenosis on the hemodynamic characteristics such as flow separation, wall shear stress (WSS) and particle depositions. RESULTS AND CONCLUSIONS: Energy loss associated with such flow expansion after each constriction will be large and consequently the pressure drop will be higher. Overall pressure drop increased from 1700 Pa (12.75 mmHg) at the end diastole to 11000 Pa (82.5 mmHg) at the peak systole. At the peak systole the WSS values reached 110 Pa in the stenosis with 28% diameter reduction and 210 Pa in the stenosis with 54% diameter reduction, which is high enough to damage the endothelial cells. However at the end of one cardiac cycle a percent of 1.4% (15 from 1063 particles release at the inlet section) remain inside the stenosed RCA.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA