Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Europace ; 25(2): 331-340, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36107465

RESUMO

AIMS: Climate change represents the biggest global health threat of the 21st century. Health care system is itself a large contributor to greenhouse gas (GHG) emissions. In cardiology, atrial fibrillation (AF) catheter ablation is an increasing activity using numerous non-reusable materials that could contribute to GHG emission. Determining a detailed carbon footprint analysis of an AF catheter ablation procedure allows the identification of the main polluting sources that give opportunities for reduction of environmental impact. To assess the carbon footprint of AF catheter ablation procedure. To determine priority actions to decrease pollution. METHODS AND RESULTS: An eco-audit method used to predict the GHG emission of an AF catheter ablation procedure was investigated. Two workstations were considered including surgery and anaesthesia. In the operating room, every waste produced by single-use medical devices, pharmaceutical drugs, and energy consumption during intervention were evaluated. All analyses were limited to the operating room. Thirty procedures were analysed over a period of 8 weeks: 18 pulmonary veins isolation RF ablations, 7 complex RF procedures including PVI, roof and mitral isthmus lines, ethanol infusion of the Marshall vein and cavo tricuspid isthmus line, and 5 pulmonary vein isolation with cryoballoon. The mean emission during AF catheter ablation procedures was 76.9 kg of carbon dioxide equivalent (CO2-e). The operating field accounted for 75.4% of the carbon footprint, while only 24.6% for the anaesthesia workstation. On one hand, material production and manufacturing were the most polluting phases of product life cycle which, respectively, represented 71.3% (54.8 kg of CO2-e) and 17.0% (13.1 kg of CO2-e) of total pollution. On the other hand, transport contributed in 10.6% (8.1 kg of CO2-e), while product use resulted in 1.1% (0.9 kg of CO2-e) of GHG production. Electrophysiology catheters were demonstrated to be the main contributors of environmental impact with 29.9 kg of CO2-e (i.e. 38.8%). Three dimensional mapping system and electrocardiogram patches were accounting for 6.8 kg of CO2-e (i.e. 8.8% of total). CONCLUSION: AF catheter ablation involves a mean of 76.9 kg of CO2-e. With an estimated 600 000 annual worldwide procedures, the environmental impact of AF catheter ablation activity is estimated equal to 125 tons of CO2 emission each day. It represents an equivalent of 700 000 km of car ride every day. Electrophysiology catheters and patches are the main contributors of the carbon footprint. The focus must be on reducing, reusing, and recycling these items to limit the impact of AF ablation on the environment. A road map of steps to implement in different time frames is proposed.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Pegada de Carbono , Dióxido de Carbono , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento
2.
Europace ; 25(1): 101-111, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35942675

RESUMO

AIMS: Ventricular fibrillation (VF) occurring in the acute phase of ST-elevation myocardial infarction (STEMI) is the leading cause of sudden cardiac death worldwide. Several studies showed that reduced connexin 43 (Cx43) expression and reduced conduction velocity increase the risk of VF in acute myocardial infarction (MI). Furthermore, genetic background might predispose individuals to primary VF (PVF). The primary objective was to evaluate the presence of GJA1 variants in STEMI patients. The secondary objective was to evaluate the arrhythmogenic impact of GJA1 variants in STEMI patients with VF. METHODS AND RESULTS: The MAP-IDM prospective cohort study included 966 STEMI patients and was designed to identify genetic predisposition to VF. A total of 483 (50.0%) STEMI patients with PVF were included. The presence of GJA1 variants increased the risk of VF in STEMI patients [from 49.1 to 70.8%, P = 0.0423; odds ratio (OR): 0.40; 95% confidence interval: 0.16-0.97; P = 0.04]. The risk of PVF decreased with beta-blocker intake (from 53.5 to 44.8%, P = 0.0085), atrial fibrillation (from 50.7 to 26.4%, P = 0.0022), and with left ventricular ejection fraction >50% (from 60.2 to 41.4%, P < 0.0001). Among 16 GJA1 variants, three novel heterozygous missense variants were identified in three patients: V236I, H248R, and I327M. In vitro studies of these variants showed altered Cx43 localization and decreased cellular communication, mainly during acidosis. CONCLUSION: Connexin 43 variants are associated with increased VF susceptibility in STEMI patients. Restoring Cx43 function may be a potential therapeutic target to prevent PVF in patients with acute MI. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT00859300.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/genética , Fibrilação Ventricular/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/genética , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Conexina 43/genética , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/genética , Fatores de Risco
3.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37695311

RESUMO

AIMS: The incidence of atrial tachyarrhythmias is high in patients with atrioventricular septal defect (AVSD). No specific data on catheter ablation have been reported so far in this population. We aimed to describe the main mechanisms of atrial tachyarrhythmias in patients with AVSD and to analyse outcomes after catheter ablation. METHODS AND RESULTS: This observational multi-centric cohort study enrolled all patients with AVSD referred for catheter ablation of an atrial tachyarrhythmia at six tertiary centres from 2004 to 2022. The mechanisms of the different tachyarrhythmias targeted were described and outcomes were analysed. Overall, 56 patients (38.1 ± 17.4 years, 55.4% females) were included. A total of 87 atrial tachyarrhythmias were targeted (mean number of 1.6 per patient). Regarding main circuits involved, a cavo-annular isthmus-dependent intra-atrial re-entrant tachycardia (IART) was observed in 41 (73.2%) patients and an IART involving the right lateral atriotomy in 10 (17.9%) patients. Other tachyarrhythmias with heterogeneous circuits were observed in 13 (23.2%) patients including 11 left-sided and 4 right-sided tachyarrhythmias. Overall, an acute success was achieved in 54 (96.4%) patients, and no complication was reported. During a mean follow-up of 2.8 ± 3.8 years, 22 (39.3%) patients had at least one recurrence. Freedom from atrial tachyarrhythmia recurrences was 77.5% at 1 year. Among 15 (26.8%) patients who underwent repeated ablation procedures, heterogeneous circuits including bi-atrial and left-sided tachyarrhythmias were more frequent. CONCLUSION: In patients with AVSD, most circuits involve the cavo-annular isthmus, but complex mechanisms are frequently encountered in patients with repeated procedures. The acute success rate is excellent, although recurrences remain common during follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Feminino , Humanos , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos de Coortes , Taquicardia/diagnóstico , Taquicardia/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
4.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-32998542

RESUMO

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Assuntos
Desfibriladores Implantáveis/tendências , Tetralogia de Fallot/epidemiologia , Tetralogia de Fallot/terapia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Sistema de Registros
5.
Indian Pacing Electrophysiol J ; 21(5): 291-302, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34157427

RESUMO

The important increase in life expectancy of adult patients with congenital heart disease (ACHD) has generated new challenges, including arrhythmias that represent one of the main late complications. Reentrant atrial arrhythmias are by far the main mechanism encountered, and catheter ablation has been now presented as a first-line therapy in this patient population. The number of procedures is expected to continuously increase year after year. The heterogeneity and complexity of phenotypes encountered require these cases to be performed by highly experienced operators, in specialized centers with multidisciplinary competencies. A thorough knowledge and understanding of anatomic specificities, vascular access issues, and main circuits encountered according to underlying phenotype is essential. Acute success rates have significantly improved and are now excellent, but recurrences remain a common issue, with different mechanisms or circuits frequently encountered. Observational data have suggested the interest of systematically targeting all inducible atrial arrhythmias, whether previously documented or not, and a lot of hope and research is based on the prediction of arrhythmia substrate before arrhythmia development by imaging or electroanatomic mapping to deliver a prophylactic patient tailored ablation approach. In this review, we summarize those different points in the most common or distinctive defects to offer a didactic overview of atrial flutter catheter ablation in ACHD patients.

6.
J Electrocardiol ; 63: 6-11, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33011474

RESUMO

OBJECTIVES: To determine the prognostic value of a low T/R ratio, defined as the amplitude ratio between the T waves and the R waves, in patients (pts) with a spontaneous type-1 Brugada pattern (SBT1). BACKGROUND: Abnormalities of myocardial repolarization may play a key role in the initiation of ventricular fibrillation (VF) in Brugada syndrome (BrS). Recent studies have shown that the height of the T waves and the T/R ratio are inversely proportional to sudden cardiac arrest (SCA) risk in early repolarization syndrome and hypertrophic cardiomyopathy. METHODS: In an international retrospective study, we reviewed 115 pts. (105 males, 91.3%). 45 had VF and/or SCA (38.7 ±â€¯11.5 years old, all males), while 70 (49.3 ±â€¯12.0 years, 10 women) remained free of ventricular arrhythmia. 6 ECG markers plus the T/R ratio in leads V5 & II were studied. RESULTS: The T/R ratio among leads II & V5 was significantly lower in the VF/SCA group (0.24 [0.14; 0.38]vs. 0.34 [0.24; 0.45]; p = 0.006). 44.4% of pts. in the VF/SCA group had a lowest T/R ratio among leads II & V5 ≤ 0.17 compared to 11.4% in the non-VF/SCA group (p < 0.001). In multivariate analysis, a lowest T/R ratio among leads II & V5 ≤ 0.17 was independently associated with VF/SCA (OR 6.10, 95% CI 1.92-19.40; p = 0.002). Type 1 Brugada pattern in the peripheral leads (OR 10.78) and early repolarization (OR 3.60) were other independent markers of VF/SCA. CONCLUSION: A low T/R ratio among leads II & V5 is an independent marker for VF/SCA risk in patients with type-1 Brugada pattern.


Assuntos
Síndrome de Brugada , Adulto , Síndrome de Brugada/diagnóstico , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fibrilação Ventricular/diagnóstico
7.
Europace ; 21(9): 1400-1409, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31177270

RESUMO

AIMS: There is currently no reliable tool to quantify the risks of ventricular fibrillation or sudden cardiac arrest (VF/SCA) in patients with spontaneous Brugada type 1 pattern (BrT1). Previous studies showed that electrocardiographic (ECG) markers of depolarization or repolarization disorders might indicate elevated risk. We aimed to design a VF/SCA risk prediction model based on ECG analyses for adult patients with spontaneous BrT1. METHODS AND RESULTS: This retrospective multicentre international study analysed ECG data from 115 patients (mean age 45.1 ± 12.8 years, 105 males) with spontaneous BrT1. Of these, 45 patients had experienced VF/SCA and 70 patients did not experience VF/SCA. Among 10 ECG markers, a univariate analysis showed significant associations between VF/SCA and maximum corrected Tpeak-Tend intervals ≥100 ms in precordial leads (LMaxTpec) (P < 0.001), BrT1 in a peripheral lead (pT1) (P = 0.004), early repolarization in inferolateral leads (ER) (P < 0.001), and QRS duration ≥120 ms in lead V2 (P = 0.002). The Cox multivariate analysis revealed four predictors of VF/SCA: the LMaxTpec [hazard ratio (HR) 8.3, 95% confidence interval (CI) 2.4-28.5; P < 0.001], LMaxTpec + ER (HR 14.9, 95% CI 4.2-53.1; P < 0.001), LMaxTpec + pT1 (HR 17.2, 95% CI 4.1-72; P < 0.001), and LMaxTpec + pT1 + ER (HR 23.5, 95% CI 6-93; P < 0.001). Our multidimensional penalized spline model predicted the 1-year risk of VF/SCA, based on age and these markers. CONCLUSION: LMaxTpec and its association with pT1 and/or ER indicated elevated VF/SCA risk in adult patients with spontaneous BrT1. We successfully developed a simple risk prediction model based on age and these ECG markers.


Assuntos
Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia , Fibrilação Ventricular/epidemiologia , Adulto , Fatores Etários , Síndrome de Brugada/complicações , Morte Súbita Cardíaca/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fibrilação Ventricular/etiologia
9.
Europace ; 20(suppl_2): ii1-ii4, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29722859

RESUMO

Aims: Achieving adequate catheter tip-tissue contact is essential for delivering robust radiofrequency (RF) ablation lesions. We measured the contact force generated by a remote magnetic-guided catheter navigation system. Methods and results: A plexiglass model with an integrated scale was fashioned to mimic transvenous and retrograde access to sites in the right atrium and right and left ventricles. An 8 Fr RF ablation catheter was steered by remote magnetic guidance at fields of 0.08 and 0.10 T, with and without a long sheath positioned at the entrance of the chamber. Ten contact force readings were taken at each setting, with the scale recalibrated prior to each measurement. Generalized estimating equations were used to compare contact force measurements while adjusting for the non-independent data structure. A total of 240 contact force measurements were taken. Without a long sheath, contact forces with magnetic fields of 0.10 T (n = 60) and 0.08 T (n = 60) were similar (6.1 ± 1.4 g vs. 6.0 ± 1.3 g, P = 0.089). Contact forces were not significantly different with simulated transvenous (n = 80) and retrograde aortic (n = 40) approaches (6.2 ± 1.4 g vs. 5.7 ± 1.2 g, P = 0.132). The contact force increased substantially with a long sheath (P < 0.001) and was significantly higher with 0.10 T (n = 60) vs. 0.08 T (n = 60) fields (20.4 ± 0.6 g vs. 18.0 ± 0.5 g, P < 0.001). Conclusion: Magnetic fields of 0.08 and 0.10 T provide stable catheter contact forces, as reflected by the small variability between measurements. The average contact force is approximately 6 g without a sheath and increases to 20 g with a long sheath positioned at the entrance of the chamber of interest.


Assuntos
Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Magnetismo/métodos , Cirurgia Assistida por Computador/métodos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Átrios do Coração/anatomia & histologia , Ventrículos do Coração/anatomia & histologia , Humanos , Magnetismo/instrumentação , Imãs , Modelos Anatômicos , Modelos Cardiovasculares , Pressão , Cirurgia Assistida por Computador/instrumentação , Transdutores de Pressão
10.
J Cardiovasc Electrophysiol ; 28(5): 559-563, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28233925

RESUMO

INTRODUCTION: The standard 4-minute application time for transcatheter cryoablation was determined in the 1990s when the system employed less potent chlorofluorocarbon refrigerants. The current refrigerant, nitrous oxide, generates substantially colder temperatures, with a faster cooling rate. METHODS AND RESULTS: We conducted a preclinical study on 32 mongrel dogs with stratified randomization of right atrial, right ventricular, and left ventricular chambers to 2-minute versus 4-minute application times using 8-mm electrode tip cryocatheters (Freezor Max, Medtronic CryoCath LP, Montreal, Canada). Animals were sacrificed one month after the procedure. Three-dimensional morphometric analyses were conducted in a blinded fashion. A total of 193 identified ablation lesions were processed for histological analyses, 102 with 2-minute applications and 91 with 4-minute applications. Ablation lesion surface area (167.8 ± 21.6 mm2 vs. 194.3 ± 22.6 mm2 , P = 0.40), maximum depth (4.4 ± 0.2 mm vs. 4.5 ± 0.2 mm, P = 0.71), and volume (125.7 ± 69.5 mm3 vs. 141.0 ± 83.5 mm3 , P = 0.25) were similar between groups. Overall, 90.2% of ablation lesions in the right atrium were transmural, 45.6% in the right ventricle, and 2.4% in the left ventricle, with no differences between 2-minute and 4-minute application times (P = 0.55). Thrombus was detected on the endocardial surface of 0.0% and 3.3% of ablation lesions created with 2-minute and 4-minute application times, respectively (P = 0.10). CONCLUSION: Single 2-minute and 4-minute application times result in catheter ablation lesions of similar size using the modern cryoablation system with nitrous oxide as a refrigerant. While these findings suggest the potential to reduce the standard 4-minute application time, further studies are required to compare clinical efficacy.


Assuntos
Cateterismo Cardíaco/métodos , Temperatura Baixa , Criocirurgia/métodos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Óxido Nitroso/farmacologia , Animais , Cães , Átrios do Coração/patologia , Ventrículos do Coração/patologia , Modelos Animais , Fatores de Tempo
13.
Arch Cardiovasc Dis ; 117(5): 313-320, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38704288

RESUMO

BACKGROUND: In patients with congenital long QT syndrome (LQTS), the risk of ventricular arrhythmia is correlated with the duration of the corrected QT interval and the changes in the ST-T wave pattern on the 12-lead surface electrocardiogram (12L-ECG). Remote monitoring of these variables could be useful. AIM: To evaluate the abilities of two wearable electrocardiogram devices (Apple Watch and KardiaMobile 6L) to provide reliable electrocardiograms in terms of corrected QT interval and ST-T wave patterns in patients with LQTS. METHODS: In a prospective multicentre study (ClinicalTrials.gov identifier: NCT04728100), a 12L-ECG, a 6-lead KardiaMobile 6L electrocardiogram and two single-lead Apple Watch electrocardiograms were recorded in patients with LQTS. The corrected QT interval and ST-T wave patterns were evaluated manually. RESULTS: Overall, 98 patients with LQTS were included; 12.2% were children and 92.8% had a pathogenic variant in an LQTS gene. The main genotypes were LQTS type 1 (40.8%), LQTS type 2 (36.7%) and LQTS type 3 (7.1%); rarer genotypes were also represented. When comparing the ST-T wave patterns obtained with the 12L-ECG, the level of agreement was moderate with the Apple Watch (k=0.593) and substantial with the KardiaMobile 6L (k=0.651). Regarding the corrected QT interval, the correlation with 12L-ECG was strong for the Apple Watch (r=0.703 in lead II) and moderate for the KardiaMobile 6L (r=0.593). There was a slight overestimation of corrected QT interval with the Apple Watch and a subtle underestimation with the KardiaMobile 6L. CONCLUSIONS: In patients with LQTS, the corrected QT interval and ST-T wave patterns obtained with the Apple Watch and the KardiaMobile 6L correlated with the 12L-ECG. Although wearable electrocardiogram devices cannot replace the 12L-ECG for the follow-up of these patients, they could be interesting additional monitoring tools.


Assuntos
Frequência Cardíaca , Síndrome do QT Longo , Valor Preditivo dos Testes , Dispositivos Eletrônicos Vestíveis , Humanos , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/congênito , Síndrome do QT Longo/genética , Feminino , Masculino , Estudos Prospectivos , Criança , Adolescente , Adulto , Reprodutibilidade dos Testes , Adulto Jovem , Eletrocardiografia Ambulatorial/instrumentação , Potenciais de Ação , Pré-Escolar , Desenho de Equipamento , Fatores de Tempo , Pessoa de Meia-Idade , Eletrocardiografia/instrumentação , Sistema de Condução Cardíaco/fisiopatologia
14.
Arch Cardiovasc Dis ; 117(3): 224-231, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38302391

RESUMO

Sustainability in healthcare, particularly within the domain of cardiac electrophysiology, assumes paramount importance for the near future. The escalating environmental constraints encountered necessitate a proactive approach. This position paper aims to raise awareness among physicians, spark critical inquiry and identify potential solutions to enhance the sustainability of our practice. Reprocessing of single-use medical devices has emerged as a potential solution to mitigate the environmental impact of electrophysiology procedures, while also offering economic advantages. However, reprocessing remains unauthorized in certain countries. In regions where it is possible, stringent regulatory standards must be adhered to, to ensure patient safety. It is essential that healthcare professionals, policymakers and manufacturers collaborate to drive innovation, explore sustainable practices and ensure that patient care remains uncompromised in the face of environmental challenges. Ambitious national/international programmes of disease prevention should be the cornerstone of the strategy. It is equally vital to implement immediate actions, as delineated in this position paper, to bring about tangible change quickly.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/terapia , Sociedades Médicas
15.
Artigo em Inglês | MEDLINE | ID: mdl-38970599

RESUMO

BACKGROUND: Idiopathic ventricular fibrillation (IVF) can be associated with undetected distinct conditions such as microstructural cardiomyopathic alterations (MiCM) or Purkinje (Purk) activities with structurally normal hearts. OBJECTIVE: This study sought to evaluate the characteristics of recurrent VF recorded on implantable defibrillator electrograms, associated with these substrates. METHODS: This was a multicenter collaboration study. At 32 centers, we selected patients with an initial diagnosis of IVF and recurrent arrhythmia at follow-up without antiarrhythmic drugs, in whom mapping demonstrated Purk or MiCM substrate. We analyzed variables related to previous ectopy, sinus rate preceding VF, trigger, and initial VF cycle lengths. Logistic regression with cross validation was used to evaluate the performance of criteria to discriminate Purk or MiCM substrates. RESULTS: Among 95 patients (35 women, age 35 ± 11 years) meeting the inclusion criteria, IVF was associated with MiCM in 41 and Purk in 54 patients. A total of 117 arrhythmia recurrences including 91% VF were recorded on defibrillator. Three variables were mostly discriminant. Sinus tachycardia (≤570 ms) was more frequent in MiCM (35.9% vs 13.4%, P = 0.014) whereas short-coupled (<350 ms) triggers were most frequent in Purk-related VF (95.5% vs 23.1%, P = 0.001), which also had shorter VFCLs (182 ± 15 ms vs 215 ± 24 ms, P < 0.001).The multivariable combination provided the highest prediction (accuracy = 0.93 ± 0.05, range 0.833-1.000), discriminating 81% of IVF substrates with a high probability (>80%). Ectopy were inconsistently present before VF. CONCLUSIONS: Characteristics of arrhythmia recurrences on implantable cardioverter- defibrillator provide phenotypic markers of the distinct and hidden substrates underlying IVF. These findings have significant clinical and genetic implications.

17.
Eur Heart J Case Rep ; 7(2): ytad053, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36819877

RESUMO

Background: Intra-atrial reentrant tachycardia (IART) is a frequent arrhythmia in patients with Fontan circulation. Although its supraventricular origin, such arrhythmia can be poorly tolerated as it leads to haemodynamic impairment. Concomitant assessment of pressure/volume overload of cardiac chambers due to valvular disease or residual shunts is necessary. Case summary: We report the case of a 33-year-old male with Fontan extracardiac conduit, suffering from IART with initial poor haemodynamic tolerance. He had a medical history of pulmonary atresia with intact ventricular septum and Type 0 bicuspid aortic valve, with a total of four cardiac surgeries. Echocardiography demonstrated a severe impairment of the univentricular ejection fraction and a critical aortic stenosis. Given the limited medical treatment options of the arrhythmia and the risks of another heart surgery, both IART ablation and transcatheter aortic valve replacement (TAVR) were performed during the same procedure. The IART critical isthmus located in the antero-lateral region of the extracardiac conduit was effectively treated with radiofrequency. Rapid pacing during TAVR was provided by a catheter placed in the unique ventricle via a transconduit puncture. The aortic valve was deployed with minimal para-valvular regurgitation and a satisfactory transvalvular gradient. At follow-up, the univentricular ejection fraction normalized and no arrhythmic episode was recorded in absence of anti-arrhythmic drugs. Discussion: This case highlights the need of a collaborative approach for treating complex cases of adult congenital heart disease, suffering from both electrophysiological and haemodynamic disorders. This combination offered an elegant and safest solution for treating concomitantly a life-threatening arrhythmia and an aortic stenosis.

18.
Expert Rev Cardiovasc Ther ; 21(7): 507-517, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37246899

RESUMO

INTRODUCTION: The prevalence of congenital heart disease (CHD) is steadily increasing among adults. Atrial arrhythmias are frequent late complications and are associated with substantial morbidity. AREAS COVERED: We discuss key considerations regarding management strategies for atrial arrhythmias in common forms of CHD and offer future perspectives. EXPERT OPINION: An appreciation of the types of atrial arrhythmias encountered in patients with diverse forms of CHD, combined with the growing clinical and research experience, appears to be yielding favorable results, whereas little progress has been made on the antiarrhythmic drug front, indications for anticoagulation have considerably evolved. Advances in interventional techniques have propelled catheter ablation to the forefront to treat a variety of atrial arrhythmias in patients with complex CHD. Nevertheless, much work remains to be done to elucidate underlying pathophysiology, triggers, and critical substrates that predispose patients with specific CHD malformations to develop atrial arrhythmias. Future advances could allow for the implementation of individualized, possibly preemptive, approaches to arrhythmia management. With the prevalence of atrial fibrillation on the rise in the aging population with CHD, concerted efforts must be directed toward optimizing patient selection for catheter ablation as well as refining procedural aspects to safely and more effectively improve long-term outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas , Adulto , Humanos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Prevalência
19.
J Pers Med ; 13(2)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36836569

RESUMO

Arrhythmogenic cardiomyopathy (ACM) is a rare genetic disease associated with ventricular arrhythmias in patients. The occurrence of these arrhythmias is due to direct electrophysiological remodeling of the cardiomyocytes, namely a reduction in the action potential duration (APD) and a disturbance of Ca2+ homeostasis. Interestingly, spironolactone (SP), a mineralocorticoid receptor antagonist, is known to block K+ channels and may reduce arrhythmias. Here, we assess the direct effect of SP and its metabolite canrenoic acid (CA) in cardiomyocytes derived from human-induced pluripotent stem cells (hiPSC-CMs) of a patient bearing a missense mutation (c.394C>T) in the DSC2 gene coding for desmocollin 2 and for the amino acid replacement of arginine by cysteine at position 132 (R132C). SP and CA corrected the APD in the muted cells (vs. the control) in linking to a normalization of the hERG and KCNQ1 K+ channel currents. In addition, SP and CA had a direct cellular effect on Ca2+ homeostasis. They reduced the amplitude and aberrant Ca2+ events. In conclusion, we show the direct beneficial effects of SP on the AP and Ca2+ homeostasis of DSC2-specific hiPSC-CMs. These results provide a rationale for a new therapeutical approach to tackle mechanical and electrical burdens in patients suffering from ACM.

20.
Heart Rhythm ; 20(12): 1689-1696, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37598989

RESUMO

BACKGROUND: Patients with repaired tetralogy of Fallot (TOF) are at risk for ventricular tachycardia (VT) related to well-described anatomical isthmuses. OBJECTIVE: The purpose of this study was to explore QRS morphology as an indicator of anatomical isthmus conduction. METHODS: Patients with repaired TOF and complete right bundle branch block referred for transcatheter pulmonary valve replacement (PVR) or presenting with sustained VT underwent comprehensive 3-dimensional mapping in sinus rhythm. Electrocardiographic characteristics were compared to right ventricular (RV) activation and anatomical isthmus conduction properties. RESULTS: Twenty-two patients (19 pre-pulmonary valve replacement and 3 clinical VT) underwent comprehensive 3-dimensional mapping (median 39 years; interquartile range [IQR] 27-48 years; 12 [55%] male). Septal RV activation (median 40 ms; IQR 34-46 ms) corresponded to the nadir in lead V1 and free wall activation (median 71 ms; IQR 64-81 ms) to the transition point in the upstroke of the R' wave. Patients with isthmus block between the pulmonary annulus and the ventricular septal defect patch and between the ventricular septal defect patch and the tricuspid annulus (when present), were more likely to demonstrate lower amplitude R' waves in lead V1 (5.8 mV vs 9.4 mV; P = .005), QRS fragmentation in lead V1 (15 [94%] vs 2 [13%]; P < .001), and terminal S waves in lead aVF (15 [94%] vs 6 [40%]; P < .001) than those with intact conduction. During catheter ablation, these QRS changes developed during isthmus block. CONCLUSION: For patients with repaired TOF, the status of septal isthmus conduction was evident from sinus rhythm QRS morphology. Low-amplitude, fragmented R' waves in lead V1 and terminal S waves in the inferior leads were related to septal isthmus conduction abnormalities, providing a mechanistic link between RV activation and common electrocardiographic findings.


Assuntos
Comunicação Interventricular , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Masculino , Feminino , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/cirurgia , Ventrículos do Coração , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Eletrocardiografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA