Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(2): 1146-1154, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37615760

RESUMO

OBJECTIVES: To investigate whether baseline 18F-sodium fluoride (NaF) and 18F-choline PET activity is associated with metastatic castration-resistant prostate cancer (mCRPC) global and individual bone metastases' DWI MR imaging response to radium-223 treatment. METHODS: Thirty-six bone-only mCRPC patients were prospectively recruited from three centers. Whole-body (WB)-MRI with DWI and 18F-NaF and 18F-choline PET/CT were performed at therapy baseline and 8-week intervals. In each patient, bone disease median global (g)ADC change between baseline and follow-up was calculated. Additionally, up to five bone target lesions per patient were delineated and individual median ADC change recorded. An ADC increase > 30% defined response per-patient and per-lesion. For the same targets, baseline 18F-NaF and 18F-choline PET SUVmax were recorded. Mean SUVmax across patient targets was correlated with gADC change and lesion SUVmax with per-lesion ADC change. RESULTS: A total of 133 lesions in 36 patients (14 responders) were analyzed. 18F-NaF PET per-patient mean SUVmax was significantly higher in responders (median = 56.0 versus 38.7 in non-responders; p = 0.008), with positive correlation between SUVmax and gADC increase (rho = 0.42; p = 0.015). A 48.7 SUVmax threshold identified responders with 77% sensitivity and 75% specificity. Baseline 18F-NaF PET per-lesion SUVmax was higher in responding metastases (median = 51.6 versus 31.8 in non-responding metastases; p = 0.001), with positive correlation between baseline lesion SUVmax and ADC increase (rho = 0.39; p < 0.001). A 36.8 SUVmax threshold yielded 72% sensitivity and 63% specificity. No significant association was found between baseline 18F-choline PET SUVmax and ADC response on a per-patient (p = 0.164) or per-lesion basis (p = 0.921). CONCLUSION: 18F-NaF PET baseline SUVmax of target mCRPC bone disease showed significant association with response to radium-223 defined by ADC change. CLINICAL RELEVANCE STATEMENT: 18F-sodium fluoride PET/CT baseline maximum SUV of castration-resistant prostate cancer bone metastases could be used as a predictive biomarker for response to radium-223 therapy. KEY POINTS: • 18F-sodium fluoride PET baseline SUVmax of castration-resistant prostate cancer bone metastases showed significant association with response to radium-223. • Baseline 18F-sodium fluoride PET can improve patient selection for radium-223 therapy. • Change in whole-body DWI parameters can be used for response correlation with baseline 18F-sodium fluoride PET SUVmax in castration-resistant prostate cancer bone metastases.


Assuntos
Neoplasias Ósseas , Colina/análogos & derivados , Neoplasias de Próstata Resistentes à Castração , Rádio (Elemento) , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluoreto de Sódio/uso terapêutico , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/radioterapia , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Radioisótopos de Flúor , Neoplasias Ósseas/tratamento farmacológico
2.
Eur Radiol ; 33(2): 863-871, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36169688

RESUMO

OBJECTIVE: To establish optimised diffusion weightings ('b-values') for acquisition of whole-body diffusion-weighted MRI (WB-DWI) for estimation of the apparent diffusion coefficient (ADC) in patients with metastatic melanoma (MM). Existing recommendations for WB-DWI have not been optimised for the tumour properties in MM; therefore, evaluation of acquisition parameters is essential before embarking on larger studies. METHODS: Retrospective clinical data and phantom experiments were used. Clinical data comprised 125 lesions from 14 examinations in 11 patients with multifocal MM, imaged before and/or after treatment with immunotherapy at a single institution. ADC estimates from these data were applied to a model to estimate the optimum b-value. A large non-diffusing phantom was used to assess eddy current-induced geometric distortion. RESULTS: Considering all tumour sites from pre- and post-treatment examinations together, metastases exhibited a large range of mean ADC values, [0.67-1.49] × 10-3 mm2/s, and the optimum high b-value (bhigh) for ADC estimation was 1100 (10th-90th percentile: 740-1790) s/mm2. At higher b-values, geometric distortion increased, and longer echo times were required, leading to reduced signal. CONCLUSIONS: Theoretical optimisation gave an optimum bhigh of 1100 (10th-90th percentile: 740-1790) s/mm2 for ADC estimation in MM, with the large range of optimum b-values reflecting the wide range of ADC values in these tumours. Geometric distortion and minimum echo time increase at higher b-values and are not included in the theoretical optimisation; bhigh in the range 750-1100 s/mm2 should be adopted to maintain acceptable image quality but performance should be evaluated for a specific scanner. KEY POINTS: • Theoretical optimisation gave an optimum high b-value of 1100 (10th-90th percentile: 740-1790) s/mm2 for ADC estimation in metastatic melanoma. • Considering geometric distortion and minimum echo time (TE), a b-value in the range 750-1100 s/mm2 is recommended. • Sites should evaluate the performance of specific scanners to assess the effect of geometric distortion and minimum TE.


Assuntos
Melanoma , Segunda Neoplasia Primária , Humanos , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Melanoma/diagnóstico por imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
Eur Radiol ; 32(7): 4647-4656, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35092476

RESUMO

OBJECTIVES: To evaluate whether multiparametric bone MRI (mpBMRI) utilising a combination of DWI signal, ADC and relative fat-fraction (rFF) can identify bone metastases, which provide high diagnostic biopsy yield and next-generation genomic sequencing (NGS) feasibility. METHODS: A total of 150 CT-guided bone biopsies performed by interventional radiologists (3/2013 to 2/2021) at our centre were reviewed. In 43 patients, contemporaneous DWI and rFF images, calculated from 2-point T1w Dixon MRI, were available. For each biopsied lesion, a region of interest (ROI) was delineated on ADC and rFF images and the following MRI parameters were recorded: visual classification of DWI signal intensity (SI), mean, median, 10th and 90th centile ADC and rFF values. Non-parametric tests were used to compare values between tumour positive/negative biopsies and feasible/non-feasible NGS, with p-values < 0.05 deemed significant. RESULTS: The mpBMRI combination high DWI signal, mean ADC < 1100 µm2/s and mean rFF < 20% identified tumour-positive biopsies with 82% sensitivity, 80% specificity, a positive predictive value (PPV) of 93% (p = 0.001) and NGS feasibility with 91% sensitivity, 78% specificity and 91% PPV (p < 0.001). The single MRI parameters DWI signal, ADC and rFF failed to distinguish between tumour-positive and tumour-negative biopsies (each p > 0.082). In NGS feasible biopsies, mean and 90th centile rFF were significantly smaller (each p < 0.041). Single ADC parameters did not show significant difference regarding NGS feasibility (each p > 0.292). CONCLUSIONS: MpBMRI utilising the combination of DWI signal, ADC and rFF can identify active bone metastases, which provide biopsy tissue with high diagnostic yield and NGS feasibility. KEY POINTS: • Multiparametric bone MRI with diffusion-weighted and relative fat-fraction images helps to identify active bone metastases suitable for CT-guided biopsy. • Target lesions for CT-guided bone biopsies in cancer patients can be chosen with greater confidence. • CT-guided bone biopsy success rates, especially yielding sufficient viable tissue for advanced molecular tissue analyses, can be improved.


Assuntos
Neoplasias Ósseas , Imagem de Difusão por Ressonância Magnética , Biópsia , Neoplasias Ósseas/secundário , Imagem de Difusão por Ressonância Magnética/métodos , Estudos de Viabilidade , Humanos , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X
4.
Eur Radiol ; 32(10): 6820-6829, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35881184

RESUMO

OBJECTIVES: Investigate the laboratory, imaging and procedural factors that are associated with a tumour-positive and/or NGS-feasible CT-guided sclerotic bone lesion biopsy result in cancer patients. METHODS: In total, 113 CT-guided bone biopsies performed in cancer patients by an interventional radiologist in one institution were retrospectively reviewed. Sixty-five sclerotic bone biopsies were eventually included and routine blood parameters and tumour marker levels were recorded. Non-contrast (NC) biopsy CTs (65), contrast-enhanced CTs (24), and PET/CTs (22) performed within four weeks of biopsy were reviewed; lesion location, diameter, lesion-to-cortex distance, and NC-CT appearance (dense-sclerosis versus mild-sclerosis) were noted. Mean NC-CT, CE-CT HU, and PET SUVmax were derived from biopsy tract and lesion segmentations. Needle diameter, tract length, and number of samples were noted. Comparisons between tumour-positive/negative and next-generation sequencing (NGS)-feasible/non-feasible biopsies determined significant (p < 0.05) laboratory, imaging, and procedural parameter differences. RESULTS: Seventy-four percent of biopsies were tumour-positive. NGS was feasible in 22/30 prostate cancer patients (73%). Neither laboratory blood parameters, PET/CT availability, size, nor lesion-to-cortex distance affected diagnostic yield or NGS feasibility (p > 0.298). Eighty-seven percent of mildly sclerotic bone (mean 244 HU) biopsies were positive compared with 56% in dense sclerosis (622 HU, p = 0.005) and NC-CT lesion HU was significantly lower in positive biopsies (p = 0.003). A 610 HU threshold yielded 89% PPV for tumour-positive biopsies and a 370 HU threshold 94% PPV for NGS-feasible biopsies. FDG-PET and procedural parameters were non-significant factors (each p > 0.055). CONCLUSION: In cancer patients with sclerotic bone disease, targeting areas of predominantly mild sclerosis in lower CT-attenuation lesions can improve tumour tissue yield and NGS feasibility. KEY POINTS: • Areas of predominantly mild sclerosis should be preferred to areas of predominantly dense sclerosis for CT-guided bone biopsies in cancer patients. • Among sclerotic bone lesions in prostate cancer patients, lesions with a mean HU below 370 should be preferred as biopsy targets to improve NGS feasibility. • Laboratory parameters and procedure related factors may have little implications for CT-guided sclerotic bone biopsy success.


Assuntos
Doenças Ósseas , Neoplasias Ósseas , Doenças das Cartilagens , Neoplasias da Próstata , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia , Humanos , Biópsia Guiada por Imagem/métodos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Esclerose , Tomografia Computadorizada por Raios X/métodos
5.
Radiology ; 291(1): 5-13, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30806604

RESUMO

Acknowledging the increasingly important role of whole-body MRI for directing patient care in myeloma, a multidisciplinary, international, and expert panel of radiologists, medical physicists, and hematologists with specific expertise in whole-body MRI in myeloma convened to discuss the technical performance standards, merits, and limitations of currently available imaging methods. Following guidance from the International Myeloma Working Group and the National Institute for Clinical Excellence in the United Kingdom, the Myeloma Response Assessment and Diagnosis System (or MY-RADS) imaging recommendations are designed to promote standardization and diminish variations in the acquisition, interpretation, and reporting of whole-body MRI in myeloma and allow response assessment. This consensus proposes a core clinical protocol for whole-body MRI and an extended protocol for advanced assessments. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Assuntos
Mieloma Múltiplo/diagnóstico , Guias de Prática Clínica como Assunto , Consenso , Coleta de Dados , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Projetos de Pesquisa , Imagem Corporal Total/métodos , Imagem Corporal Total/normas
6.
Eur Radiol ; 28(4): 1687-1691, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29134357

RESUMO

OBJECTIVES: The aim of this study was to identify apparent diffusion coefficient (ADC) values for typical haemangiomas in the spine and to compare them with active malignant focal deposits. METHODS: This was a retrospective single-institution study. Whole-body magnetic resonance imaging (MRI) scans of 106 successive patients with active multiple myeloma, metastatic prostate or breast cancer were analysed. ADC values of typical vertebral haemangiomas and malignant focal deposits were recorded. RESULTS: The ADC of haemangiomas (72 ROIs, median ADC 1,085×10-6mm2s-1, interquartile range 927-1,295×10-6mm2s-1) was significantly higher than the ADC of malignant focal deposits (97 ROIs, median ADC 682×10-6mm2s-1, interquartile range 583-781×10-6mm2s-1) with a p-value < 10-6. Receiver operating characteristic (ROC) analysis produced an area under the curve of 0.93. An ADC threshold of 872×10-6mm2s-1 separated haemangiomas from malignant focal deposits with a sensitivity of 84.7 % and specificity of 91.8 %. CONCLUSIONS: ADC values of classical vertebral haemangiomas are significantly higher than malignant focal deposits. The high ADC of vertebral haemangiomas allows them to be distinguished visually and quantitatively from active sites of disease, which show restricted diffusion. KEY POINTS: • Whole-body diffusion-weighted MRI is becoming widely used in myeloma and bone metastases. • ADC values of vertebral haemangiomas are significantly higher than malignant focal deposits. • High ADCs of haemangiomas allows them to be distinguished from active disease.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Hemangioma/diagnóstico por imagem , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/secundário , Imagem Corporal Total/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Radiology ; 284(1): 88-99, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28301311

RESUMO

Purpose To assess the repeatability of apparent diffusion coefficient (ADC) estimates in extracranial soft-tissue diffusion-weighted magnetic resonance imaging across a wide range of imaging protocols and patient populations. Materials and Methods Nine prospective patient studies and one prospective volunteer study, performed between 2006 and 2016 with research ethics committee approval and written informed consent from each subject, were included in this single-institution study. A total of 141 tumors and healthy organs were imaged twice (interval between repeated examinations, 45 minutes to 10 days, depending the on study) to assess the repeatability of median and mean ADC estimates. The Levene test was used to determine whether ADC repeatability differed between studies. The Pearson linear correlation coefficient was used to assess correlation between coefficient of variation (CoV) and the year the study started, study size, and volumes of tumors and healthy organs. The repeatability of ADC estimates from small, medium, and large tumors and healthy organs was assessed irrespective of study, and the Levene test was used to determine whether ADC repeatability differed between these groups. Results CoV aggregated across all studies was 4.1% (range for each study, 1.7%-6.5%). No correlation was observed between CoV and the year the study started or study size. CoV was weakly correlated with volume (r = -0.5, P = .1). Repeatability was significantly different between small, medium, and large tumors (P < .05), with the lowest CoV (2.6%) for large tumors. There was a significant difference in repeatability between studies-a difference that did not persist after the study with the largest tumors was excluded. Conclusion ADC is a robust imaging metric with excellent repeatability in extracranial soft tissues across a wide range of tumor sites, sizes, patient populations, and imaging protocol variations. Online supplemental material is available for this article.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias de Tecidos Moles/diagnóstico por imagem , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Radiology ; 283(1): 168-177, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27875103

RESUMO

Purpose To determine the usefulness of whole-body diffusion-weighted imaging (DWI) to assess the response of bone metastases to treatment in patients with metastatic castration-resistant prostate cancer (mCRPC). Materials and Methods A phase II prospective clinical trial of the poly-(adenosine diphosphate-ribose) polymerase inhibitor olaparib in mCRPC included a prospective magnetic resonance (MR) imaging substudy; the study was approved by the institutional research board, and written informed consent was obtained. Whole-body DWI was performed at baseline and after 12 weeks of olaparib administration by using 1.5-T MR imaging. Areas of abnormal signal intensity on DWI images in keeping with bone metastases were delineated to derive total diffusion volume (tDV); five target lesions were also evaluated. Associations of changes in volume of bone metastases and median apparent diffusion coefficient (ADC) with response to treatment were assessed by using the Mann-Whitney test and logistic regression; correlation with prostate-specific antigen level and circulating tumor cell count were assessed by using Spearman correlation (r). Results Twenty-one patients were included. All six responders to olaparib showed a decrease in tDV, while no decrease was observed in all nonresponders; this difference between responders and nonresponders was significant (P = .001). Increases in median ADC were associated with increased odds of response (odds ratio, 1.08; 95% confidence interval [CI]: 1.00, 1.15; P = .04). A positive association was detected between changes in tDV and best percentage change in prostate-specific antigen level and circulating tumor cell count (r = 0.63 [95% CI: 0.27, 0.83] and r = 0.77 [95% CI: 0.51, 0.90], respectively). When assessing five target lesions, decreases in volume were associated with response (odds ratio for volume increase, 0.89; 95% CI: 0.80, 0.99; P = .037). Conclusion This pilot study showed that decreases in volume and increases in median ADC of bone metastases assessed with whole-body DWI can potentially be used as indicators of response to olaparib in mCRPC. Online supplemental material is available for this article.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/patologia , Adulto , Idoso , Antineoplásicos/uso terapêutico , Biomarcadores Tumorais , Neoplasias Ósseas/tratamento farmacológico , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Ftalazinas/uso terapêutico , Projetos Piloto , Piperazinas/uso terapêutico , Estudos Prospectivos , Resultado do Tratamento , Imagem Corporal Total
9.
Eur Radiol ; 27(11): 4552-4562, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28396997

RESUMO

PURPOSE: To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. METHODS: Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800smm-2). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. RESULTS: Whole-tumour ADC values ranged from 0.66-1.94x10-3mm2s-1 (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson's R2 = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. CONCLUSION: A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change. KEY POINTS: • In lung cancer, free-breathing DWI-MRI produces acceptable images with evaluable ADC measurement. • ADC repeatability coefficient-of-variation is 7.1% for lung tumours >2 cm. • ADC repeatability coefficient-of-variation is 3.9% for lung tumours >3 cm. • ADC measurement precision is unaffected by the post-processing software used. • In multicentre trials, 22% increase in ADC indicates positive treatment response.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Pulmonares/patologia , Estadiamento de Neoplasias/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Carga Tumoral
10.
AJR Am J Roentgenol ; 209(6): W336-W349, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28981354

RESUMO

OBJECTIVE: The purpose of this article is to review current image acquisition and interpretation for whole-body MRI, clinical applications, and the emerging roles in oncologic imaging, especially in the assessment of bone marrow diseases. CONCLUSION: Whole-body MRI is an emerging technique used for early diagnosis, staging, and assessment of therapeutic response in oncology. The improved accessibility and advances in technology, including widely available sequences (Dixon and DWI), have accelerated its deployment and acceptance in clinical practice.


Assuntos
Imageamento por Ressonância Magnética/métodos , Oncologia , Neoplasias/diagnóstico por imagem , Imagem Corporal Total/métodos , Humanos
11.
Radiology ; 280(1): 151-60, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26807894

RESUMO

Purpose To determine the correlation between the volume of bone metastasis as assessed with diffusion-weighted (DW) imaging and established prognostic factors in metastatic castration-resistant prostate cancer (mCRPC) and the association with overall survival (OS). Materials and Methods This retrospective study was approved by the institutional review board; informed consent was obtained from all patients. The authors analyzed whole-body DW images obtained between June 2010 and February 2013 in 53 patients with mCRPC at the time of starting a new line of anticancer therapy. Bone metastases were identified and delineated on whole-body DW images in 43 eligible patients. Total tumor diffusion volume (tDV) was correlated with the bone scan index (BSI) and other prognostic factors by using the Pearson correlation coefficient (r). Survival analysis was performed with Kaplan-Meier analysis and Cox regression. Results The median tDV was 503.1 mL (range, 5.6-2242 mL), and the median OS was 12.9 months (95% confidence interval [CI]: 8.7, 16.1 months). There was a significant correlation between tDV and established prognostic factors, including hemoglobin level (r = -0.521, P < .001), prostate-specific antigen level (r = 0.556, P < .001), lactate dehydrogenase level (r = 0.534, P < .001), alkaline phosphatase level (r = 0.572, P < .001), circulating tumor cell count (r = 0.613, P = .004), and BSI (r = 0.565, P = .001). A higher tDV also showed a significant association with poorer OS (hazard ratio, 1.74; 95% CI: 1.02, 2.96; P = .035). Conclusion Metastatic bone disease from mCRPC can be evaluated and quantified with whole-body DW imaging. Whole-body DW imaging-generated tDV showed correlation with established prognostic biomarkers and is associated with OS in mCRPC. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias de Próstata Resistentes à Castração/patologia , Imagem Corporal Total/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/patologia , Osso e Ossos/diagnóstico por imagem , Osso e Ossos/patologia , Intervalo Livre de Doença , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Carga Tumoral
12.
J Magn Reson Imaging ; 44(1): 130-7, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26762608

RESUMO

PURPOSE: To evaluate the diagnostic sensitivity of computed diffusion-weighted (DW)-MR imaging for the detection of breast cancer. MATERIALS AND METHODS: Local research ethics approval was obtained. A total of 61 women (median 48 years) underwent dynamic contrast enhanced (DCE)- and DW-MR between January 2011 and March 2012, including 27 with breast cancer on core biopsy and 34 normal cases. Standard ADC maps using all four b values (0, 350, 700, 1150) were used to generate computed DW-MR images at b = 1500 s/mm(2) and b = 2000 s/mm(2) . Four image sets were read sequentially by two readers: acquired b = 1150 s/mm(2) , computed b = 1500 s/mm(2) and b = 2000 s/mm(2) , and DCE-MR at an early time point. Cancer detection was rated using a five-point scale; image quality and background suppression were rated using a four-point scale. The diagnostic sensitivity for breast cancer detection was compared using the McNemar test and inter-reader agreement with a Kappa value. RESULTS: Computed DW-MR resulted in higher overall diagnostic sensitivity with b = 2000 s/mm(2) having a mean diagnostic sensitivity of 76% (range 49.8-93.7%) and b = 1500 s/mm(2) having a mean diagnostic sensitivity of 70.3% (range 32-97.7%) compared with 44.4% (range 25.5-64.7%) for acquired b = 1150 s/mm(2) (both p = 0.0001). Computed DW-MR images produced better image quality and background suppression (mean scores for both readers: 2.55 and 2.9 for b 1500 s/mm(2) ; 2.55 and 3.15 for b 2000 s/mm(2) , respectively) than the acquired b value 1150 s/mm(2) images (mean scores for both readers: 2.4 and 2.45, respectively). CONCLUSION: Computed DW-MR imaging has the potential to improve the diagnostic sensitivity of breast cancer detection compared to acquired DW-MR. J. Magn. Reson. Imaging 2016;44:130-137.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Phys Imaging Radiat Oncol ; 29: 100554, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38419803

RESUMO

Background and purpose: Interfraction motion during cervical cancer radiotherapy is substantial in some patients, minimal in others. Non-adaptive plans may miss the target and/or unnecessarily irradiate normal tissue. Adaptive radiotherapy leads to superior dose-volume metrics but is resource-intensive. The aim of this study was to predict target motion, enabling patient selection and efficient resource allocation. Materials and methods: Forty cervical cancer patients had CT with full-bladder (CT-FB) and empty-bladder (CT-EB) at planning, and daily cone-beam CTs (CBCTs). The low-risk clinical target volume (CTVLR) was contoured. Mean coverage of the daily CTVLR by the CT-FB CTVLR was calculated for each patient. Eighty-three investigated variables included measures of organ geometry, patient, tumour and treatment characteristics. Models were trained on 29 patients (171 fractions). The Two-CT multivariate model could use all available data. The Single-CT multivariate model excluded data from the CT-EB. A univariate model was trained using the distance moved by the uterine fundus tip between CTs, the only method of patient selection found in published cervix plan-of-the-day studies. Models were tested on 11 patients (68 fractions). Accuracy in predicting mean coverage was reported as mean absolute error (MAE), mean squared error (MSE) and R2. Results: The Two-CT model was based upon rectal volume, dice similarity coefficient between CT-FB and CT-EB CTVLR, and uterine thickness. The Single-CT model was based upon rectal volume, uterine thickness and tumour size. Both performed better than the univariate model in predicting mean coverage (MAE 7 %, 7 % and 8 %; MSE 82 %2, 65 %2, 110 %2; R2 0.2, 0.4, -0.1). Conclusion: Uterocervix motion is complex and multifactorial. We present two multivariate models which predicted motion with reasonable accuracy using pre-treatment information, and outperformed the only published method.

14.
Bioengineering (Basel) ; 11(2)2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38391616

RESUMO

BACKGROUND: Whole-Body Diffusion-Weighted Imaging (WBDWI) is an established technique for staging and evaluating treatment response in patients with multiple myeloma (MM) and advanced prostate cancer (APC). However, WBDWI scans show inter- and intra-patient intensity signal variability. This variability poses challenges in accurately quantifying bone disease, tracking changes over follow-up scans, and developing automated tools for bone lesion delineation. Here, we propose a novel automated pipeline for inter-station, inter-scan image signal standardisation on WBDWI that utilizes robust segmentation of the spinal canal through deep learning. METHODS: We trained and validated a supervised 2D U-Net model to automatically delineate the spinal canal (both the spinal cord and surrounding cerebrospinal fluid, CSF) in an initial cohort of 40 patients who underwent WBDWI for treatment response evaluation (80 scans in total). Expert-validated contours were used as the target standard. The algorithm was further semi-quantitatively validated on four additional datasets (three internal, one external, 207 scans total) by comparing the distributions of average apparent diffusion coefficient (ADC) and volume of the spinal cord derived from a two-component Gaussian mixture model of segmented regions. Our pipeline subsequently standardises WBDWI signal intensity through two stages: (i) normalisation of signal between imaging stations within each patient through histogram equalisation of slices acquired on either side of the station gap, and (ii) inter-scan normalisation through histogram equalisation of the signal derived within segmented spinal canal regions. This approach was semi-quantitatively validated in all scans available to the study (N = 287). RESULTS: The test dice score, precision, and recall of the spinal canal segmentation model were all above 0.87 when compared to manual delineation. The average ADC for the spinal cord (1.7 × 10-3 mm2/s) showed no significant difference from the manual contours. Furthermore, no significant differences were found between the average ADC values of the spinal cord across the additional four datasets. The signal-normalised, high-b-value images were visualised using a fixed contrast window level and demonstrated qualitatively better signal homogeneity across scans than scans that were not signal-normalised. CONCLUSION: Our proposed intensity signal WBDWI normalisation pipeline successfully harmonises intensity values across multi-centre cohorts. The computational time required is less than 10 s, preserving contrast-to-noise and signal-to-noise ratios in axial diffusion-weighted images. Importantly, no changes to the clinical MRI protocol are expected, and there is no need for additional reference MRI data or follow-up scans.

15.
Cancers (Basel) ; 16(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38730599

RESUMO

(1) Background: We assessed the test-re-test repeatability of radiomics in metastatic castration-resistant prostate cancer (mCPRC) bone disease on whole-body diffusion-weighted (DWI) and T1-weighted Dixon MRI. (2) Methods: In 10 mCRPC patients, 1.5 T MRI, including DWI and T1-weighted gradient-echo Dixon sequences, was performed twice on the same day. Apparent diffusion coefficient (ADC) and relative fat-fraction-percentage (rFF%) maps were calculated. Per study, up to 10 target bone metastases were manually delineated on DWI and Dixon images. All 106 radiomic features included in the Pyradiomics toolbox were derived for each target volume from the ADC and rFF% maps. To account for inter- and intra-patient measurement repeatability, the log-transformed individual target measurements were fitted to a hierarchical model, represented as a Bayesian network. Repeatability measurements, including the intraclass correlation coefficient (ICC), were derived. Feature ICCs were compared with mean ADC and rFF ICCs. (3) Results: A total of 65 DWI and 47 rFF% targets were analysed. There was no significant bias for any features. Pairwise correlation revealed fifteen ADC and fourteen rFF% feature sub-groups, without specific patterns between feature classes. The median intra-patient ICC was generally higher than the inter-patient ICC. Features that describe extremes in voxel values (minimum, maximum, range, skewness, and kurtosis) showed generally lower ICCs. Several mostly shape-based texture features were identified, which showed high inter- and intra-patient ICCs when compared with the mean ADC or mean rFF%, respectively. (4) Conclusions: Pyradiomics texture features of mCRPC bone metastases varied greatly in inter- and intra-patient repeatability. Several features demonstrated good repeatability, allowing for further exploration as diagnostic parameters in mCRPC bone disease.

16.
Radiother Oncol ; 195: 110266, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38582181

RESUMO

BACKGROUND: Pneumonitis is a well-described, potentially disabling, or fatal adverse effect associated with both immune checkpoint inhibitors (ICI) and thoracic radiotherapy. Accurate differentiation between checkpoint inhibitor pneumonitis (CIP) radiation pneumonitis (RP), and infective pneumonitis (IP) is crucial for swift, appropriate, and tailored management to achieve optimal patient outcomes. However, correct diagnosis is often challenging, owing to overlapping clinical presentations and radiological patterns. METHODS: In this multi-centre study of 455 patients, we used machine learning with radiomic features extracted from chest CT imaging to develop and validate five models to distinguish CIP and RP from COVID-19, non-COVID-19 infective pneumonitis, and each other. Model performance was compared to that of two radiologists. RESULTS: Models to distinguish RP from COVID-19, CIP from COVID-19 and CIP from non-COVID-19 IP out-performed radiologists (test set AUCs of 0.92 vs 0.8 and 0.8; 0.68 vs 0.43 and 0.4; 0.71 vs 0.55 and 0.63 respectively). Models to distinguish RP from non-COVID-19 IP and CIP from RP were not superior to radiologists but demonstrated modest performance, with test set AUCs of 0.81 and 0.8 respectively. The CIP vs RP model performed less well on patients with prior exposure to both ICI and radiotherapy (AUC 0.54), though the radiologists also had difficulty distinguishing this test cohort (AUC values 0.6 and 0.6). CONCLUSION: Our results demonstrate the potential utility of such tools as a second or concurrent reader to support oncologists, radiologists, and chest physicians in cases of diagnostic uncertainty. Further research is required for patients with exposure to both ICI and thoracic radiotherapy.


Assuntos
COVID-19 , Inibidores de Checkpoint Imunológico , Aprendizado de Máquina , Pneumonite por Radiação , Tomografia Computadorizada por Raios X , Humanos , Inibidores de Checkpoint Imunológico/efeitos adversos , Inibidores de Checkpoint Imunológico/uso terapêutico , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Diagnóstico Diferencial , Pneumonia/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/tratamento farmacológico , SARS-CoV-2
17.
Br J Radiol ; 96(1151): 20230378, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37660399

RESUMO

OBJECTIVES: To assess the repeatability of quantitative multiparametric whole-body MRI (mpWB-MRI) parameters in advanced prostate cancer (APC) bone metastases. METHODS: 1.5T MRI was performed twice on the same day in 10 APC patients. MpWB-MRI-included diffusion weighted imaging (DWI) and T1-weighted gradient-echo 2-point Dixon sequences. ADC and relative fat-fraction percentage (rFF%) maps were calculated, respectively. A radiologist delineated up to 10 target bone metastases per study. Means of ADC, b900 signal intensity(SI), normalised b900 SI, rFF% and maximum diameter (MD) for each target lesion and overall parameter averages across all targets per patient were recorded. The total disease volume (tDV in ml) was manually delineated on b900 images and mean global (g)ADC was derived. Bland-Altman analyses were performed with calculation of 95% repeatability coefficients (RC). RESULTS: Seventy-three individual targets (median MD 26 mm) were included. Lesion mean ADC RC was 12.5%, mean b900 SI RC 137%, normalised mean b900 SI RC 110%, rFF% RC 3.2 and target MD RC 5.5 mm (16.3%). Patient target lesion average mean ADC RC was 6.4%, b900 SI RC 104% and normalised mean b900 SI RC 39.6%. Target average rFF% RC was 1.8, average MD RC 1.3 mm (4.8%). tDV segmentation RC was 6.4% and mean gADC RC 5.3%. CONCLUSIONS: APC bone metastases' ADC, rFF% and maximum diameter, tDV and gADC show good repeatability. ADVANCES IN KNOWLEDGE: APC bone metastases' mean ADC and rFF% measurements of single lesions and global disease volumes are repeatable, supporting their potential role as quantitative biomarkers in metastatic bone disease.


Assuntos
Neoplasias Ósseas , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias Ósseas/patologia
18.
Sci Rep ; 13(1): 10568, 2023 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-37386097

RESUMO

Handcrafted and deep learning (DL) radiomics are popular techniques used to develop computed tomography (CT) imaging-based artificial intelligence models for COVID-19 research. However, contrast heterogeneity from real-world datasets may impair model performance. Contrast-homogenous datasets present a potential solution. We developed a 3D patch-based cycle-consistent generative adversarial network (cycle-GAN) to synthesize non-contrast images from contrast CTs, as a data homogenization tool. We used a multi-centre dataset of 2078 scans from 1,650 patients with COVID-19. Few studies have previously evaluated GAN-generated images with handcrafted radiomics, DL and human assessment tasks. We evaluated the performance of our cycle-GAN with these three approaches. In a modified Turing-test, human experts identified synthetic vs acquired images, with a false positive rate of 67% and Fleiss' Kappa 0.06, attesting to the photorealism of the synthetic images. However, on testing performance of machine learning classifiers with radiomic features, performance decreased with use of synthetic images. Marked percentage difference was noted in feature values between pre- and post-GAN non-contrast images. With DL classification, deterioration in performance was observed with synthetic images. Our results show that whilst GANs can produce images sufficient to pass human assessment, caution is advised before GAN-synthesized images are used in medical imaging applications.


Assuntos
COVID-19 , Aprendizado Profundo , Humanos , Inteligência Artificial , COVID-19/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Aprendizado de Máquina
19.
Diagnostics (Basel) ; 13(21)2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37958277

RESUMO

T2-weighted magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) are essential components of cervical cancer diagnosis. However, combining these channels for the training of deep learning models is challenging due to image misalignment. Here, we propose a novel multi-head framework that uses dilated convolutions and shared residual connections for the separate encoding of multiparametric MRI images. We employ a residual U-Net model as a baseline, and perform a series of architectural experiments to evaluate the tumor segmentation performance based on multiparametric input channels and different feature encoding configurations. All experiments were performed on a cohort of 207 patients with locally advanced cervical cancer. Our proposed multi-head model using separate dilated encoding for T2W MRI and combined b1000 DWI and apparent diffusion coefficient (ADC) maps achieved the best median Dice similarity coefficient (DSC) score, 0.823 (confidence interval (CI), 0.595-0.797), outperforming the conventional multi-channel model, DSC 0.788 (95% CI, 0.568-0.776), although the difference was not statistically significant (p > 0.05). We investigated channel sensitivity using 3D GRAD-CAM and channel dropout, and highlighted the critical importance of T2W and ADC channels for accurate tumor segmentation. However, our results showed that b1000 DWI had a minor impact on the overall segmentation performance. We demonstrated that the use of separate dilated feature extractors and independent contextual learning improved the model's ability to reduce the boundary effects and distortion of DWI, leading to improved segmentation performance. Our findings could have significant implications for the development of robust and generalizable models that can extend to other multi-modal segmentation applications.

20.
Eur J Cancer ; 192: 113261, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37604068

RESUMO

AIM: To evaluate the incidence of pseudoprogression in patients with metastatic or inoperable uterine leiomyosarcoma (LMS) treated with first-line single-agent doxorubicin. METHODS: The Royal Marsden NHS Foundation Trust Sarcoma Unit database was searched to identify all patients with metastatic or inoperable LMS treated with first-line doxorubicin from January 2006 to January 2022. Patients with available computed tomography scans performed at baseline and during doxorubicin therapy were included. Response evaluation criteria in solid tumours v1.1 and Choi criteria were applied. Any increase in the sum of the longest diameter that decreased on the subsequent scan was labelled as pseudoprogression. RESULTS: The total number of patients evaluated was 52. In total, 19% (n = 10) of patients treated with doxorubicin showed pseudoprogression. However, pseudoprogression at the time of the second scan was not associated with time to doxorubicin failure. Choi criteria identified 30% (n = 3) of pseudoprogressors as responding. CONCLUSION: Despite the use of doxorubicin as first-line therapy for soft-tissue sarcomas for over 40 years, pseudoprogression has not been described. This retrospective study shows that pseudoprogression occurs in 19% of patients with metastatic/inoperable uterine LMS treated with first-line doxorubicin. Choi criteria were not consistently able to differentiate pseudoprogression from true progression. It is imperative that oncologists and radiologists are aware of this as symptomatically stable/improving patients may benefit from continued treatment despite initial radiological growth in tumour size.


Assuntos
Leiomiossarcoma , Segunda Neoplasia Primária , Sarcoma , Neoplasias de Tecidos Moles , Humanos , Leiomiossarcoma/diagnóstico por imagem , Leiomiossarcoma/tratamento farmacológico , Estudos Retrospectivos , Sarcoma/diagnóstico por imagem , Sarcoma/tratamento farmacológico , Doxorrubicina/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA