Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

3.
Am Heart J ; 256: 139-147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36410441

RESUMO

BACKGROUND: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. METHODS: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. CONCLUSIONS: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos
4.
Catheter Cardiovasc Interv ; 101(5): 932-942, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36924015

RESUMO

BACKGROUND: With expansion of transcatheter aortic valve implantation (TAVI) into younger patients, valve durability is critically important. AIMS: We aimed to evaluate long-term valve function and incidence of severe structural valve deterioration (SVD) among patients ≥ 10-years post-TAVI and with echocardiographic follow-up at least 5-years postprocedure. METHODS: Data on patients who underwent TAVI from 2007 to 2011 were obtained from the UK TAVI registry. Patients with paired echocardiograms postprocedure and ≥5-years post-TAVI were included. Severe SVD was determined according to European task force guidelines. RESULTS: 221 patients (79.4 ± 7.3 years; 53% male) were included with median echocardiographic follow-up 7.0 years (range 5-13 years). Follow-up exceeded 10 years in 43 patients (19.5%). Valve types were the supra-annular self-expanding CoreValve (SEV; n = 143, 67%), balloon-expandable SAPIEN/XT (BEV; n = 67, 31%), Portico (n = 4, 5%) and unknown (n = 7, 3%). There was no difference between postprocedure and follow-up peak gradient in the overall cohort (19.3 vs. 18.4 mmHg; p = NS) or in those with ≥10-years follow-up (21.1 vs. 21.1 mmHg; p = NS). Severe SVD occurred in 13 patients (5.9%; median 7.8-years post-TAVI). Three cases (23.1%) were due to regurgitation and 10 (76.9%) to stenosis. Valve-related reintervention/death occurred in 5 patients (2.3%). Severe SVD was more frequent with BEV than SEV (11.9% vs. 3.5%; p = 0.02), driven by a difference in patients treated with small valves (BEV 28.6% vs. SEV 3.0%; p < 0.01). CONCLUSIONS: Hemodynamic function of transcatheter heart valves remains stable up to more than 10 years post-TAVI. Severe SVD occurred in 5.9%, and valve-related death/reintervention in 2.3%. Severe SVD was more common with BEV than SEV.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros , Reino Unido , Desenho de Prótese
5.
BMC Cardiovasc Disord ; 22(1): 450, 2022 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-36307769

RESUMO

Very short duration of dual antiplatelet therapy (DAPT) following percutaneous coronary intervention (PCI) has recently attracted a lot of attention with the introduction of newer generations stents. This is appealing, especially in patients at high bleeding risk. However, none of the trials were powered for the individual ischemic and bleeding endpoints. All randomised controlled trials (RCTs) investigating one-month versus routine duration of DAPT in patients undergoing PCI and reporting outcomes from the time of cessation of DAPT (1 month) to 1 year were eligible for inclusion in the meta-analysis. The pooled risk ratios (RR) with their 95% confidence interval (CI) were calculated with the random-effects model using the Mantel-Haenszel method. Four RCTs involving 26,576 patients were included in this meta-analysis. Cessation of DAPT after 1 month was associated with significantly less major bleeding [RR 0.70, 95%CI (0.51-0.95), P = 0.02, heterogeneity (I2) = 42%]. There was no statistically significant difference in all-cause mortality [RR 0.84 (95%CI 0.69-1.03), P = 0.10, I2 = 0%] and stroke [RR 0.71 (95%CI 0.45-1.13), P = 0.15, I2 = 42%] when compared to routine duration of DAPT. There was also no difference in myocardial infarction (MI) [RR 1.12 (95%CI 0.91-1.39), P = 0.28, I2 = 0%], and definite or probable stent thrombosis [RR 1.49 (95%CI 0.92-2.41), P = 0.11, I2 = 0%] with cessation of DAPT after 1 month. Cessation of DAPT 1 month after PCI was associated with significantly less major bleeding, but there was no difference in the rate of all-cause mortality, stroke, MI and stent thrombosis.


Assuntos
Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Humanos , Quimioterapia Combinada , Hemorragia/induzido quimicamente , Infarto do Miocárdio , Inibidores da Agregação Plaquetária/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Trombose/prevenção & controle , Trombose/induzido quimicamente , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 97(4): E552-E559, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32779877

RESUMO

OBJECTIVES: We sought to identify baseline demographics and procedural factors that might independently predict in-hospital stroke following transcatheter aortic valve implantation (TAVI). BACKGROUND: Stroke is a recognized, albeit infrequent, complication of TAVI. Established predictors of procedure-related in-hospital stroke; however, remain poorly defined. METHODS: We conducted an observational cohort analysis of the multicenter UK TAVI registry. The primary outcome measure was the incidence of in-hospital stroke. RESULTS: A total of 8,652 TAVI procedures were performed from 2007 to 2015. There were 205 in-hospital strokes reported by participating centers equivalent to an overall stroke incidence of 2.4%. Univariate analysis showed that the implantation of balloon-expandable valves caused significantly fewer strokes (balloon-expandable 96/4,613 [2.08%] vs. self-expandable 95/3,272 [2.90%]; p = .020). After multivariable analysis, prior cerebrovascular disease (CVD) (odds ratio [OR] 1.51, 95% confidence interval [CI 1.05-2.17]; p = .03), advanced age at time of operation (OR 1.02 [0.10-1.04]; p = .05), bailout coronary stenting (OR 5.94 [2.03-17.39]; p = .008), and earlier year of procedure (OR 0.93 [0.87-1.00]; p = .04) were associated with an increased in-hospital stroke risk. There was a reduced stroke risk in those who had prior cardiac surgery (OR 0.62 [0.41-0.93]; p = .01) and a first-generation balloon-expandable valve implanted (OR 0.72 [0.53-0.97]; p = .03). In-hospital stroke significantly increased 30-day (OR 5.22 [3.49-7.81]; p < .001) and 1-year mortality (OR 3.21 [2.15-4.78]; p < .001). CONCLUSIONS: In-hospital stroke after TAVI is associated with substantially increased early and late mortality. Factors independently associated with in-hospital stroke were previous CVD, advanced age, no prior cardiac surgery, and deployment of a predominantly first-generation self-expandable transcatheter heart valve.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Hospitais , Humanos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Reino Unido/epidemiologia
7.
Catheter Cardiovasc Interv ; 98(3): E444-E452, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33502784

RESUMO

OBJECTIVES: To determine whether a permanent pacemaker (PPM) in situ can enhance survival after transcatheter aortic valve implantation (TAVI), in a predominantly inoperable or high risk cohort. BACKGROUND: New conduction disturbances are the most frequent complication of TAVI, often necessitating PPM implantation before hospital discharge. METHODS: We performed an observational cohort analysis of the UK TAVI registry (2007-2015). Primary and secondary endpoints were 30-day post-discharge all-cause mortality and long-term survival, respectively. RESULTS: Of 8,651 procedures, 6,815 complete datasets were analyzed. A PPM at hospital discharge, irrespective of when implantation occurred (PPM 1.68% [22/1309] vs. no PPM 1.47% [81/5506], odds ratio [OR] 1.14, 95% confidence interval [CI] 0.71-1.84; p = .58), or a PPM implanted peri- or post-TAVI only (PPM 1.44% [11/763] vs. no PPM 1.47% [81/5506], OR 0.98 [0.51-1.85]; p = .95) did not significantly reduce the primary endpoint. Patients with a PPM at discharge were older, male, had right bundle branch block at baseline, were more likely to have received a first-generation self-expandable prosthesis and had experienced more peri- and post-procedural complications including bailout valve-in-valve rescue, bleeding and acute kidney injury. A Cox proportional hazards model demonstrated significantly reduced long-term survival in all those with a PPM, irrespective of implantation timing (hazard ratio [HR] 1.14 [1.02-1.26]; p = .019) and those receiving a PPM only at the time of TAVI (HR 1.15 [1.02-1.31]; p = .032). The reasons underlying this observation warrant further investigation. CONCLUSIONS: A PPM did not confer a survival advantage in the first 30 days after hospital discharge following TAVI.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Assistência ao Convalescente , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Masculino , Alta do Paciente , Complicações Pós-Operatórias , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 95(7): 1340-1346, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31713325

RESUMO

OBJECTIVES: The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves. BACKGROUND: The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation. METHODS: Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2 (VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all-cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%. CONCLUSIONS: Real-world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Pericárdio/transplante , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Irlanda , Masculino , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Reino Unido
9.
J Interv Cardiol ; 2020: 3070427, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32518532

RESUMO

RESPOND is a prospective, single-arm study enrolling 1014 transcatheter aortic valve replacement (TAVR) patients. The objective of this analysis is to assess the impact of cerebral embolic protection (CEP) devices and prosthetic valve repositioning on the risk of neurologic complications in patients treated with the fully repositionable Lotus Valve in the RESPOND postmarket study. Valve repositioning and CEP use were at the operators' discretion. Stroke events were adjudicated by an independent medical reviewer. This analysis assessed the baseline differences among patients according to CEP use and valve repositioning and evaluated the neurological complications at 72 hours after TAVR, hospital discharge, and 30-day follow-up. A multivariate analysis was performed to identify the potential predictors of stroke. Of the 996 patients implanted with the Lotus Valve (mean age: 80.8 years, 50.8% female, STS score 6.0 ± 6.9), 92 cases (9.2%) used CEP. The overall rate of acute stroke/transient ischemic attack (TIA) was 3.0% at 72 hours after TAVR. The 72-hour stroke/TIA rate was 1.1% in patients who had CEP and 3.2% in those who did not. Use of CEP was associated with a 2.1% absolute reduction in the risk of acute neurological events (relative risk reduction: 65.6%), although the difference was not statistically significant (p=0.51). Repositioning of the Lotus Valve occurred in 313/996 procedures (31.4%). The 72-hour rate of stroke/TIA was similar in patients who had valve repositioning (2.9%) compared with those who did not (3.1%; p=0.86). The selective use of a CEP device in the RESPOND study was associated with a nonsignificantly lower risk for stroke within 72 hours. The use of the repositioning feature of the Lotus Valve did not increase the stroke risk.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Dispositivos de Proteção Embólica , Embolia Intracraniana , Complicações Pós-Operatórias , Risco Ajustado/métodos , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Embolia Intracraniana/diagnóstico , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
10.
Eur Heart J ; 40(5): 441-451, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30357365

RESUMO

Aims: We sought to evaluate the outcomes of transcatheter mitral valve replacement (TMVR) for patients with degenerated bioprostheses [valve-in-valve (ViV)], failed annuloplasty rings [valve-in-ring (ViR)], and severe mitral annular calcification [valve-in-mitral annular calcification (ViMAC)]. Methods and results: From the TMVR multicentre registry, procedural and clinical outcomes of ViV, ViR, and ViMAC were compared according to Mitral Valve Academic Research Consortium (MVARC) criteria. A total of 521 patients with mean Society of Thoracic Surgeons score of 9.0 ± 7.0% underwent TMVR (322 patients with ViV, 141 with ViR, and 58 with ViMAC). Trans-septal access and the Sapien valves were used in 39.5% and 90.0%, respectively. Overall technical success was excellent at 87.1%. However, left ventricular outflow tract obstruction occurred more frequently after ViMAC compared with ViR and ViV (39.7% vs. 5.0% vs. 2.2%; P < 0.001), whereas second valve implantation was more frequent in ViR compared with ViMAC and ViV (12.1% vs. 5.2% vs. 2.5%; P < 0.001). Accordingly, technical success rate was higher after ViV compared with ViR and ViMAC (94.4% vs. 80.9% vs. 62.1%; P < 0.001). Compared with ViMAC and ViV groups, ViR group had more frequent post-procedural mitral regurgitation ≥moderate (18.4% vs. 13.8% vs. 5.6%; P < 0.001) and subsequent paravalvular leak closure (7.8% vs. 0.0% vs. 2.2%; P = 0.006). All-cause mortality was higher after ViMAC compared with ViR and ViV at 30 days (34.5% vs. 9.9% vs. 6.2%; log-rank P < 0.001) and 1 year (62.8% vs. 30.6% vs. 14.0%; log-rank P < 0.001). On multivariable analysis, patients with failed annuloplasty rings and severe MAC were at increased risk of mortality after TMVR [ViR vs. ViV, hazard ratio (HR) 1.99, 95% confidence interval (CI) 1.27-3.12; P = 0.003; ViMAC vs. ViV, HR 5.29, 95% CI 3.29-8.51; P < 0.001]. Conclusion: The TMVR provided excellent outcomes for patients with degenerated bioprostheses despite high surgical risk. However, ViR and ViMAC were associated with higher rates of adverse events and mid-term mortality compared with ViV.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Valva Mitral/cirurgia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Calcinose/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Anuloplastia da Valva Mitral/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
11.
Am Heart J ; 211: 60-67, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30893577

RESUMO

BACKGROUND: Mineralocorticoid receptor antagonist (MRA) therapy has been shown to prevent adverse left ventricular (LV) remodeling in ST-segment elevation myocardial infarction (STEMI) patients with heart failure. Whether initiating MRA therapy prior to primary percutaneous coronary intervention (PPCI) accrues additional benefit of reducing myocardial infarct size and preventing adverse LV remodeling is not known. We aimed to investigate whether MRA therapy initiated prior to reperfusion reduces myocardial infarct (MI) size and prevents adverse LV remodeling in STEMI patients. METHODS: STEMI patients presenting within 12 hours and with a proximal coronary artery occlusion with Thrombolysis In Myocardial Infarction flow grade 0 were consented and randomized to either an intravenous bolus of potassium canrenoate, followed by oral spironolactone for 3 months or matching placebo. The primary endpoint was MI size by cardiovascular magnetic resonance at 3 months. RESULTS: Sixty-seven patients completed the study. There was no significant difference in the final MI size at 3 months between the 2 groups (placebo: 17 ± 11%, MRA: 16 ± 10%, P = .574). There was also no difference in acute MI size (26 ± 16% versus 23 ± 14%, P = .425) or myocardial salvage (26 ± 12% versus 24 ± 8%, P = .456). At follow-up, there was a trend towards an improvement in LVEF (placebo: 49 ± 8%, MRA: 54 ± 11%, P = .053), and the MRA group had significantly greater percentage decrease in LVEDV (mean difference: -12.2 (95% CI -20.3 to -4.4)%, P = .003) and LVESV (mean difference: -18.2 (95% CI -30.1 to -6.3)%, P = .003). CONCLUSION: This pilot study showed no benefit of MRA therapy in reducing MI size in STEMI patients when initiated prior to reperfusion, but there was an improvement in LV remodeling at 3 months. Adequately powered studies are warranted to confirm these findings.


Assuntos
Ácido Canrenoico/uso terapêutico , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Espironolactona/uso terapêutico , Idoso , Técnicas de Imagem Cardíaca , Método Duplo-Cego , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudo de Prova de Conceito , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Remodelação Ventricular/efeitos dos fármacos , Remodelação Ventricular/fisiologia
12.
Catheter Cardiovasc Interv ; 93(6): 1116-1123, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30773838

RESUMO

AIMS: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post-market registry. METHODS AND RESULTS: The prospective, open-label RESPOND study enrolled 1,014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve-in-valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30-day follow-up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge (P < 0.001); mean effective orifice area (EOA) was increased from 0.6 ± 0.2 cm2 to 1.7 ± 0.4 cm2 (P < 0.001). There were no cases of moderate or severe paravalvular leak (PVL) adjudicated by the core laboratory; four subjects (13.8%) had mild PVL, 5 (17.2%) had trace PVL. The rate of pacemaker (PM) implantation for PM-naïve patients was 22.2% (6/27). CONCLUSIONS: Data from the RESPOND registry demonstrate good clinical and echocardiographic outcomes up to 1 year postimplantation in patients with bicuspid aortic valves using the repositionable Lotus Valve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Europa (Continente) , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , América Latina , Masculino , Nova Zelândia , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30394657

RESUMO

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Irlanda , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Reino Unido
14.
Eur Heart J ; 39(8): 676-684, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29253177

RESUMO

Aims: Life-threatening complications occur during transcatheter aortic valve implantation (TAVI) which can require emergent cardiac surgery (ECS). Risks and outcomes of patients needing ECS during or immediately after TAVI are still unclear. Methods and results: Incidence, risk factors, management, and outcomes of patients requiring ECS during transfemoral (TF)-TAVI were analysed from a contemporary real-world multicentre registry. Between 2013 and 2016, 27 760 patients underwent TF-TAVI in 79 centres. Of these, 212 (0.76%) patients required ECS (age 82.4 ± 6.3 years, 67.5% females, logistic EuroSCORE: 17.1%, STS-score 5.8%). The risk of ECS declined from 2013 (1.07%) to 2014 (0.70%) but remained stable since. Annual TF-TAVI numbers have more than doubled from 2013 to 2016. Leading causes for ECS were left ventricular perforation by the guidewire (28.3%) and annular rupture (21.2%). Immediate procedural mortality (<72 h) of TF-TAVI patients requiring ECS was 34.6%. Overall in-hospital mortality was 46.0%, and highest in case of annular rupture (62%). Independent predictors of in-hospital mortality following ECS were age > 85 years [odds ratio (OR) 1.87, 95% confidence interval (95% CI) (1.02-3.45), P = 0.044], annular rupture [OR 1.96, 95% CI (0.94-4.10), P = 0.060], and immediate ECS [OR 3.12, 95% CI (1.07-9.11), P = 0.037]. One year of survival of the 114 patients surviving the in-hospital period was only 40.4%. Conclusion: Between 2014 and 2016, the need for ECS remained stable around 0.7%. Left ventricular guidewire perforation and annular rupture were the most frequent causes, accounting for almost half of ECS cases. Half of the patients could be salvaged by ECS-nevertheless, 1 year of all-cause mortality was high even in those ECS patients surviving the in-hospital period.


Assuntos
Estenose da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Mortalidade Hospitalar/tendências , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Procedimentos Cirúrgicos Cardíacos/tendências , Tratamento de Emergência/tendências , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Sistema de Registros , Medição de Risco
15.
J Interv Cardiol ; 31(3): 391-399, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29696693

RESUMO

OBJECTIVES: We sought to compare using serial CMR, the quantity of AR and associated valve hemodynamics, following the first-generation CoreValve (Medtronic, Minneapolis, MN) and the second-generation Lotus valve (Boston Scientific, Natick, MA). BACKGROUND: Aortic regurgitation (AR) following Transcatheter Aortic Valve Replacement (TAVR) confers a worse prognosis and can be accurately quantified using cardiovascular magnetic resonance (CMR). Second generation valves have been specifically designed to reduce paravalvular AR and improve clinical outcomes. METHODS: Fifty-one patients (79.0 ± 7.7 years, 57% male) were recruited and imaged at three time points: immediately pre- and post-TAVR, and at 6 months. RESULTS: CMR-derived AR fraction immediately post-TAVR was greater in the CoreValve compared to Lotus group (11.7 ± 8.4 vs. 4.3 ± 3.4%, P = 0.001), as was the frequency of ≥moderate AR (9/24 (37.5%) versus 0/27, P < 0.001). However, at 6 months AR fraction had improved significantly in the CoreValve group such that the two valve designs were comparable (6.4 ± 5.0 vs 5.6 ± 5.3%, P = 0.623), with no patient in either group having ≥moderate AR. The residual peak pressure gradient immediately following TAVR was significantly lower with CoreValve compared to Lotus (14.1 ± 5.6 vs 25.4 ± 11.6 mmHg, P = 0.001), but again by 6 months the two valve designs were comparable (16.5 ± 9.4 vs 19.7 ± 10.5 mmHg, P = 0.332). There was no difference in the degree of LV reverse remodeling between the two valves at 6 months. CONCLUSION: Immediately post-TAVR, there was significantly less AR but a higher residual peak pressure gradient with the Lotus valve compared to CoreValve. However, at 6 months both devices had comparable valve hemodynamics and LV reverse remodeling.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Imageamento por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/complicações , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
16.
Eur Heart J ; 38(45): 3359-3366, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28651336

RESUMO

AIMS: RESPOND is a prospective, open-label, single-arm study evaluating the outcomes following transcatheter aortic valve implantation (TAVI) with the repositionable and fully retrievable Lotus Valve used in routine clinical practice for the treatment of patients with aortic valve stenosis. METHODS AND RESULTS: RESPOND enrolled 1014 patients at sites across Europe, New Zealand, and Latin America; 996 patients received a Lotus Valve (mean age: 80.8 years; 50.8% female; Society of Thoracic Surgeons score: 6.0 ± 6.9). Repositioning was attempted in 29.2% of patients, with 99% success. The rate of all-cause mortality in the intent-to-treat population at 30 days (primary endpoint) was 2.6% (P < 0.001 vs. pre-specified performance goal). Thirty-day clinical follow-up was completed for 97.3% of patients. Among patients who received a Lotus Valve, the 30-day overall and disabling stroke rates were 3.0% and 2.2%, respectively. The 30-day permanent pacemaker implantation rate was 30.0% in all patients, and 34.6% in pacemaker-naïve patients. Echocardiographic data at baseline and pre-discharge were assessed by an independent core laboratory. Mean aortic valve gradient declined from 37.7 ± 15.2 mmHg at baseline to 10.8 ± 4.6 mmHg at hospital discharge (P < 0.001). Aortic valve area increased from 0.7 ± 0.2 cm2 at baseline to 1.8 ± 0.4 cm2 at discharge (P < 0.001). At hospital discharge, paravalvular leak (PVL) was absent or trace in 92% of patients; no patients had severe PVL, 0.3% of patients exhibited moderate PVL, and 7.7% of patients had mild PVL. Clinical follow-up in RESPOND will extend to 5 years. CONCLUSION: The results of RESPOND confirm the safety and efficacy of TAVI with the Lotus Valve in routine clinical practice. TRIAL REGISTRATION: ClinicalTrials.gov #NCT 02031302.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Medidas de Resultados Relatados pelo Paciente , Segurança do Paciente , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Sistema de Registros , Reoperação/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
17.
J Cardiovasc Magn Reson ; 19(1): 22, 2017 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-28222749

RESUMO

BACKGROUND: Left bundle branch block (LBBB) is common following trans-catheter aortic valve replacement (TAVR) and has been linked to increased mortality, although whether this is related to less favourable cardiac reverse remodeling is unclear. The aim of the study was to investigate the impact of TAVR induced LBBB on cardiac reverse remodeling. METHODS: 48 patients undergoing TAVR for severe aortic stenosis were evaluated. 24 patients with new LBBB (LBBB-T) following TAVR were matched with 24 patients with a narrow post-procedure QRS (nQRS). Patients underwent cardiovascular magnetic resonance (CMR) prior to and 6 m post-TAVR. Measured cardiac reverse remodeling parameters included left ventricular (LV) size, ejection fraction (LVEF) and global longitudinal strain (GLS). Inter- and intra-ventricular dyssynchrony were determined using time to peak radial strain derived from CMR Feature Tracking. RESULTS: In the LBBB-T group there was an increase in QRS duration from 96 ± 14 to 151 ± 12 ms (P < 0.001) leading to inter- and intra-ventricular dyssynchrony (inter: LBBB-T 130 ± 73 vs nQRS 23 ± 86 ms, p < 0.001; intra: LBBB-T 118 ± 103 vs. nQRS 13 ± 106 ms, p = 0.001). Change in indexed LV end-systolic volume (LVESVi), LVEF and GLS was significantly different between the two groups (LVESVi: nQRS -7.9 ± 14.0 vs. LBBB-T -0.6 ± 10.2 ml/m2, p = 0.02, LVEF: nQRS +4.6 ± 7.8 vs LBBB-T -2.1 ± 6.9%, p = 0.002; GLS: nQRS -2.1 ± 3.6 vs. LBBB-T +0.2 ± 3.2%, p = 0.024). There was a significant correlation between change in QRS and change in LVEF (r = -0.434, p = 0.002) and between change in QRS and change in GLS (r = 0.462, p = 0.001). Post-procedure QRS duration was an independent predictor of change in LVEF and GLS at 6 months. CONCLUSION: TAVR-induced LBBB is associated with less favourable cardiac reverse remodeling at medium term follow up. In view of this, every effort should be made to prevent TAVR-induced LBBB, especially as TAVR is now being extended to a younger, lower risk population.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio de Ramo/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Função Ventricular Esquerda , Remodelação Ventricular , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Fenômenos Biomecânicos , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Imageamento por Ressonância Magnética , Masculino , Contração Miocárdica , Estudos Retrospectivos , Índice de Gravidade de Doença , Estresse Mecânico , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
18.
J Cardiovasc Magn Reson ; 19(1): 13, 2017 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-28173819

RESUMO

BACKGROUND: It is unknown whether circumferential strain is associated with prognosis after treatment of aortic stenosis (AS). We aimed to characterise strain in severe AS, using myocardial tagging cardiovascular magnetic resonance (CMR), prior to and following Transcatheter Aortic Valve Implantation (TAVI) and Surgical Aortic Valve Replacement (SAVR), and determine whether abnormalities in strain were associated with outcome. METHODS: CMR was performed pre- and 6 m post-intervention in 98 patients (52 TAVI, 46 SAVR; 77 ± 8 years) with severe AS. TAVI patients were older (80.9 ± 6.4 vs. 73.0 ± 7.0 years, p < 0.01) with a higher STS score (2.06 ± 0.6 vs. 6.03 ± 3.4, p < 0.001). Tagged cine images were acquired at the basal, mid and apical LV levels with a complementary spatial modulation of magnetization (CSPAMM) pulse sequence. Circumferential strain, strain rate and rotation were calculated using inTag© software. RESULTS: No significant change in basal or mid LV circumferential strain, or of diastolic strain rate, was seen following either intervention. However, a significant and comparable decline in LV torsion and twist was observed (SAVR: torsion 14.08 ± 8.40 vs. 7.81 ± 4.51, p < 0.001, twist 16.17 ± 7.01 vs.12.45 ± 4.78, p < 0.01; TAVI: torsion 14.43 ± 4.66 vs. 11.20 ± 4.62, p < 0.001, twist 16.08 ± 5.36 vs. 12.36 ± 5.21, p < 0.001) which likely reflects an improvement towards normal physiology following relief of AS. Over a maximum 6.0y follow up, there were 23 (16%) deaths following valve intervention. On multivariable Cox analysis, baseline mid LV circumferential strain was significantly associated with all-cause mortality (hazard ratio, 1.03; 1.01-1.05; p = 0.009) independent of age, LV ejection fraction and STS mortality risk score. ROC analysis indicated a mid LV circumferential strain > -18.7% was associated with significantly reduced survival. CONCLUSION: TAVI and SAVR procedures are associated with comparable declines in rotational LV mechanics at 6 m, with largely unchanged strain and strain rates. Pre-operative peak mid LV circumferential strain is associated with post-operative mortality.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Área Sob a Curva , Fenômenos Biomecânicos , Distribuição de Qui-Quadrado , Inglaterra , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Curva ROC , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Software , Estresse Mecânico , Volume Sistólico , Torção Mecânica , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
19.
Eur Heart J ; 37(24): 1910-9, 2016 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-27147610

RESUMO

BACKGROUND: Microvascular obstruction (MVO) following primary percutaneous coronary intervention (PPCI) treatment of ST-segment elevation myocardial infarction (STEMI) contributes to infarct expansion, left ventricular (LV) remodelling, and worse clinical outcomes. The REFLO-STEMI trial tested whether intra-coronary (IC) high-dose adenosine or sodium nitroprusside (SNP) reduce infarct size and/or MVO determined by cardiac magnetic resonance (CMR). METHODS AND RESULTS: REFLO-STEMI, a prospective, open-label, multi-centre trial with blinded endpoints, randomized (1:1:1) 247 STEMI patients with single vessel disease presenting within 6 h of symptom onset to IC adenosine (2-3 mg total) or SNP (500 µg total) immediately following thrombectomy and again following stenting, or to standard PPCI. The primary endpoint was infarct size % LV mass (%LVM) on CMR undertaken 24-96 h after PPCI (n = 197). Clinical follow-up was to 6 months. There was no significant difference in infarct size (%LVM, median, interquartile range, IQR) between adenosine (10.1, 4.7-16.2), SNP (10.0, 4.2-15.8), and control (8.3, 1.9-14.0), P = 0.062 and P = 0.160, respectively, vs. CONTROL: MVO (% LVM, median, IQR) was similar across groups (1.0, 0.0-3.7, P = 0.205 and 0.6, 0.0-2.4, P = 0.244 for adenosine and SNP, respectively, vs. control 0.3, 0.0-2.8). On per-protocol analysis, infarct size (%LV mass, 12.0 vs. 8.3, P = 0.031), major adverse cardiac events (hazard ratio, HR, 5.39 [1.18-24.60], P = 0.04) at 30 days and 6 months (HR 6.53 [1.46-29.2], P = 0.01) were increased and ejection fraction reduced (42.5 ± 7.2% vs. 45.7 ± 8.0%, P = 0.027) in adenosine-treated patients compared with control. CONCLUSIONS: High-dose IC adenosine and SNP during PPCI did not reduce infarct size or MVO measured by CMR. Furthermore, adenosine may adversely affect mid-term clinical outcome. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01747174; https://clinicaltrials.gov/ct2/show/NCT01747174.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Trombectomia , Resultado do Tratamento
20.
Circulation ; 131(13): 1181-90, 2015 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-25637628

RESUMO

BACKGROUND: We assessed trends in the performance of transcatheter aortic valve implantation in the United Kingdom from the first case in 2007 to the end of 2012. We analyzed changes in case mix, complications, outcomes to 6 years, and predictors of mortality. METHODS AND RESULTS: Annual cohorts were examined. Mortality outcomes were analyzed in the 92% of patients from England and Wales for whom independent mortality tracking was available. A total of 3980 transcatheter aortic valve implantation procedures were performed. In successive years, there was an increase in frequency of impaired left ventricular function, but there was no change in Logistic EuroSCORE. Overall 30-day mortality was 6.3%; it was highest in the first cohort (2007-2008), after which there were no further significant changes. One-year survival was 81.7%, falling to 37.3% at 6 years. Discharge by day 5 rose from 16.7% in 2007 and 2008 to 28% in 2012. The only multivariate preprocedural predictor of 30-day mortality was Logistic EuroSCORE ≥40. During long-term follow-up, multivariate predictors of mortality were preprocedural atrial fibrillation, chronic obstructive pulmonary disease, creatinine >200 µmol/L, diabetes mellitus, and coronary artery disease. The strongest independent procedural predictor of long-term mortality was periprocedural stroke (hazard ratio=3.00; P<0.0001). Nonfemoral access and postprocedural aortic regurgitation were also significant predictors of adverse outcome. CONCLUSIONS: We analyzed transcatheter aortic valve implantation in an entire country, with follow-up over 6 years. Although clinical profiles of enrolled patients remained unchanged, longer-term outcomes improved, and patients were discharged earlier. Periprocedural stroke, nonfemoral access, and postprocedural aortic regurgitation are predictors of adverse outcome, along with intrinsic patient risk factors.


Assuntos
Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/epidemiologia , Comorbidade , Diabetes Mellitus/epidemiologia , Grupos Diagnósticos Relacionados , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Nefropatias/epidemiologia , Curva de Aprendizado , Pneumopatias/epidemiologia , Masculino , Complicações Pós-Operatórias/epidemiologia , Prognóstico , Modelos de Riscos Proporcionais , Recidiva , Sistema de Registros/estatística & dados numéricos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/tendências , Resultado do Tratamento , Reino Unido/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA