Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Rep Pract Oncol Radiother ; 27(4): 655-658, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36196424

RESUMO

Background: Data are scarce on the efficacy of a second radiosurgery (SRS) treatment of vestibular schwannoma that has progressed following initial treatment with SRS. We sought to report the outcome of our repeat SRS series with long-term imaging follow-up. Materials and methods: We retrospectively analyzed 6 patients who met the following criteria: Repeat SRS at our institution between 1995 and 2018; solitary unilateral tumor; no evidence of neurofibromatosis; and magnetic resonance (MR) planning for both SRS treatments. All treatments were delivered with a linear accelerator-based system using head frame immobilization. The prescribed dose to the periphery of the tumor was 12.5 Gy in all initial and repeat SRS treatments, except for one repeat treatment to 10 Gy. Results: Follow-up with MR scan following the second SRS treatment was a median 8.4 years. The tumor control rate (lack of progression) following the second SRS treatment was 83% (5/6). Actuarial 10-year outcomes following repeat SRS were: tumor control, 80%; absolute survival, 80%; and cause-specific survival, 100%. Of the patients with at least minimal hearing retention before initial SRS, none had ipsilateral hearing preservation after initial radiation treatment. Improvement in any pretreatment cranial nerve deficits was not seen. The only permanent grade ≥ 3 toxicity from repeat SRS was a case of infraorbital nerve deficit. No patient developed a stroke, malignant transformation, induced second tumor, or facial nerve deficit. Conclusion: There was excellent overall survival, tumor control, and low morbidity in our series for recurrent vestibular schwannoma submitted to repeat single-fraction SRS, supporting additional studies of this treatment strategy.

2.
J Appl Clin Med Phys ; 22(5): 89-96, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33783960

RESUMO

PURPOSE: The purpose of this study was to evaluate the performance of three common deformable image registration (DIR) packages across algorithms and institutions. METHODS AND MATERIALS: The Deformable Image Registration Evaluation Project (DIREP) provides ten virtual phantoms derived from computed tomography (CT) datasets of head-and-neck cancer patients over a single treatment course. Using the DIREP phantoms, DIR results from 35 institutions were submitted using either Velocity, MIM, or Eclipse. Submitted deformation vector fields (DVFs) were compared to ground-truth DVFs to calculate target registration error (TRE) for six regions of interest (ROIs). Statistical analysis was performed to determine the variability between each DIR software package and the variability of users within each algorithm. RESULTS: Overall mean TRE was 2.04 ± 0.35 mm for Velocity, 1.10 ± 0.29 mm for MIM, and 2.35 ± 0.15 mm for Eclipse. The MIM mean TRE was significantly different than both Velocity and Eclipse for all ROIs. Velocity and Eclipse mean TREs were not significantly different except for when evaluating the registration of the cord or mandible. Significant differences between institutions were found for the MIM and Velocity platforms. However, these differences could be explained by variations in Velocity DIR parameters and MIM software versions. CONCLUSIONS: Average TRE was shown to be <3 mm for all three software platforms. However, maximum errors could be larger than 2 cm indicating that care should be exercised when using DIR. While MIM performed statistically better than the other packages, all evaluated algorithms had an average TRE better than the largest voxel dimension. For the phantoms studied here, significant differences between algorithm users were minimal suggesting that the algorithm used may have more impact on DIR accuracy than the particular registration technique employed. A significant difference in TRE was discovered between MIM versions showing that DIR QA should be performed after software upgrades as recommended by TG-132.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Cabeça , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
3.
AJR Am J Roentgenol ; 211(6): 1283-1290, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30354270

RESUMO

OBJECTIVE: The purpose of this study was to develop a road map for rapid construction of anthropomorphic phantoms from computational human phantoms for use in diagnostic imaging dosimetry studies. These phantoms are ideal for performing pregnant-patient dosimetry because the phantoms imitate the size and attenuation properties of an average-sized pregnant woman for multiple gestational periods. MATERIALS AND METHODS: The method was derived from methods and materials previously described but adapted for 3D printing technology. A 3D printer was used to transform computational models into a physical duplicate with small losses in spatial accuracy and to generate tissue-equivalent materials characterized for diagnostic energy x-rays. A series of pregnant abdomens were selected as prototypes because of their large size and complex modeling. The process involved the following steps: segmentation of anatomy used for modeling; transformation of the computational model into a printing file format; preparation, characterization, and introduction of phantom materials; and model removal and phantom assembly. RESULTS: The density of the homogenized soft tissue-equivalent substitute was optimized by combining 9.0% by weight of urethane filler powder and 91.0% urethane polymer, which resulted in a mean density of 1.041 g/cm3 measured over 20 samples. Density varied among all of the samples by 0.0026 g/cm3. The total variation in density was 0.00261 g/cm3. The half-value layer of the bone material was measured to be 1.7 mm of bone material at 120 kVp and when simulated by use of the density of the bone tissue-equivalent substitute (1.60 g/cm3) was determined to be 1.61 mm of bone tissue. For dosimetry purposes the phantom provided excellent results for evaluating a site's protocol based on scan range. CONCLUSION: The 3D printing technology is applicable to the fabrication of phantoms used for performing dosimetry. The tissue-equivalent materials used to substitute for the soft tissue were developed to be highly adaptable for optimization based on the dosimetry application. Use of this method resulted in more automated phantom construction with decreased construction time and increased out-of-slice spatial resolution of the phantoms.


Assuntos
Antropometria , Simulação por Computador , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Impressão Tridimensional , Radiometria , Feminino , Humanos , Gravidez
4.
Blood ; 124(8): 1232-41, 2014 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-24802774

RESUMO

Hematopoietic stem cell (HSC)-derived cells are involved in wound healing responses throughout the body. Unfortunately for mammals, wound repair typically results in scarring and nonfunctional reparation. Among vertebrates, none display such an extensive ability for adult regeneration as urodele amphibians, including 1 of the more popular models: the axolotl. However, a lack of knowledge of axolotl hematopoiesis hinders the use of this animal for the study of hematopoietic cells in scar-free wound healing and tissue regeneration. We used white and cytomegalovirus:green fluorescent protein(+) transgenic white axolotl strains to map sites of hematopoiesis and develop hematopoietic cell transplant methodology. We also established a fluorescence-activated cell sorter enrichment technique for major blood lineages and colony-forming unit assays for hematopoietic progenitors. The liver and spleen are both active sites of hematopoiesis in adult axolotls and contain transplantable HSCs capable of long-term multilineage blood reconstitution. As in zebrafish, use of the white axolotl mutant allows direct visualization of homing, engraftment, and hematopoiesis in real time. Donor-derived hematopoiesis occurred for >2 years in recipients generating stable hematopoietic chimeras. Organ segregation, made possible by embryonic microsurgeries wherein halves of 2 differently colored embryos were joined, indicate that the spleen is the definitive site of adult hematopoiesis.


Assuntos
Hematopoese/fisiologia , Células-Tronco Hematopoéticas/citologia , Células-Tronco Hematopoéticas/metabolismo , Regeneração/fisiologia , Ambystoma mexicanum , Animais , Animais Geneticamente Modificados , Sobrevivência de Enxerto/fisiologia , Transplante de Células-Tronco Hematopoéticas
5.
J Appl Clin Med Phys ; 17(3): 25-40, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167256

RESUMO

Benchmarking is a process in which standardized tests are used to assess system performance. The data produced in the process are important for comparative purposes, particularly when considering the implementation and quality assurance of DIR algorithms. In this work, five commercial DIR algorithms (MIM, Velocity, RayStation, Pinnacle, and Eclipse) were benchmarked using a set of 10 virtual phantoms. The phantoms were previously developed based on CT data collected from real head and neck patients. Each phantom includes a start of treatment CT dataset, an end of treatment CT dataset, and the ground-truth deformation vector field (DVF) which links them together. These virtual phantoms were imported into the commercial systems and registered through a deformable process. The resulting DVFs were compared to the ground-truth DVF to determine the target registration error (TRE) at every voxel within the image set. Real treatment plans were also recalculated on each end of treatment CT dataset and the dose transferred according to both the ground-truth and test DVFs. Dosimetric changes were assessed, and TRE was correlated with changes in the DVH of individual structures. In the first part of the study, results show mean TRE on the order of 0.5 mm to 3 mm for all phan-toms and ROIs. In certain instances, however, misregistrations were encountered which produced mean and max errors up to 6.8 mm and 22 mm, respectively. In the second part of the study, dosimetric error was found to be strongly correlated with TRE in the brainstem, but weakly correlated with TRE in the spinal cord. Several interesting cases were assessed which highlight the interplay between the direction and magnitude of TRE and the dose distribution, including the slope of dosimetric gradients and the distance to critical structures. This information can be used to help clinicians better implement and test their algorithms, and also understand the strengths and weaknesses of a dose adaptive approach.


Assuntos
Algoritmos , Neoplasias de Cabeça e Pescoço/patologia , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Benchmarking , Feminino , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
6.
Stereotact Funct Neurosurg ; 92(5): 323-33, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25277349

RESUMO

BACKGROUND: Despite the conformity of stereotactic radiosurgery (SRS) treatment, there are concerns about the risk of malignancy. OBJECTIVE: We compared the number of cancer cases observed after treatment in a group of SRS patients to the number of cancer cases that would be expected in an age- and gender-matched group. METHODS: We collected data from the University of Florida SRS database for patients treated for meningiomas, intracranial schwannomas, arteriovenous malformations (AVMs), trigeminal neuralgia, pituitary adenomas, cavernous angiomas, and metastases. We used the Florida Cancer Data System (FCDS) to determine the actual cancer rates for SRS-treated patients, and we compared these to the cancer rates in similar groups of non-SRS-treated patients based on rates available from the SEER (surveillance epidemiology and end results) database. RESULTS: A total of 2,369 patients were analyzed. Of these, 862 were patients with metastases who were analyzed only to ensure the sensitivity of using the FCDS to determine malignancy rates. The results for patients with more than 5 years of follow-up are reported. Without the metastases patients, a total of 627 patients had more than 5 years of follow-up data. Follow-up in patient-years was 1,711 for the meningioma patients, 1,851 for the schwannoma patients, 1,407 for the AVM patients and 338 for patients with a diagnosis of 'other'. The observed cancer rate in the meningioma patients was 3.96% compared to the expected rate of 10% (binomial 95% confidence interval, CI = 1.85-7.94). The observed cancer rate in the schwannoma patients was 4.93% compared to the expected rate of 12.5% (95% CI = 2.61-8.89). The observed cancer rate in the AVM patients was 3.64% compared to the expected rate of 4.43% (95% CI = 1.49-8.10). The observed cancer rate in patients treated for other diagnoses (e.g. pituitary adenoma or trigeminal neuralgia) was 0% compared to the expected rate of 6.36% (95% CI = 0-11.7). CONCLUSIONS: In a large population of SRS-treated patients, there was no increased risk of malignancy compared to the general population.


Assuntos
Neoplasias Encefálicas/cirurgia , Malformações Arteriovenosas Intracranianas/cirurgia , Neoplasias Induzidas por Radiação/etiologia , Radiocirurgia/efeitos adversos , Neuralgia do Trigêmeo/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aceleradores de Partículas , Radiocirurgia/instrumentação , Estudos Retrospectivos , Risco , Resultado do Tratamento , Adulto Jovem
7.
Am J Clin Oncol ; 47(3): 110-114, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37981700

RESUMO

OBJECTIVE: The safety of single-treatment stereotactic radiosurgery (SRS) for vestibular schwannoma (VS) with radiographic evidence of brainstem compression but without motor deficit is controversial. Data on linear accelerator (linac)-based SRS in this setting are scarce. We address this with an outcomes report from an unselected series of patients with VS with radiographic brainstem compression treated with linac SRS. METHODS: We included 139 patients with unilateral VS (any size) with radiographic brainstem compression (all without serious brainstem neurological deficits). The SRS prescription dose was 12.5 Gy (single fraction) using 6MV linac-produced photon beams, delivered with a multiple arc technique. Inclusion criteria required at least 1 year of radiographic follow-up with magnetic resonance imaging. The primary endpoint was freedom from serious brainstem toxicity (≥grade 3 Common Terminology Criteria for Adverse Events v5); the secondary was freedom from enlargement (tumor progression or any requiring intervention). We assessed serious cranial nerve complications, excluding hearing loss, defined as Common Terminology Criteria for Adverse Events v5 grade 3 toxicity. RESULTS: Median magnetic resonance imaging follow-up time was 5 years, and median tumor size was 2.5 cm in greatest axial dimension and 5 ml in volume. The median brainstem D0.03 ml=12.6 Gy and median brainstem V10 Gy=0.4 ml. At 5 years, the actuarial freedom from serious brainstem toxicity was 100%, and freedom from tumor enlargement (requiring surgery and/or due to progression) was 90%. Severe facial nerve damage in patients without tumor enlargement was 0.9%. CONCLUSION: Linac-based SRS, as delivered in our series for VS with radiographic brainstem compression, is safe and effective.


Assuntos
Neuroma Acústico , Radiocirurgia , Humanos , Neuroma Acústico/diagnóstico por imagem , Neuroma Acústico/radioterapia , Neuroma Acústico/etiologia , Resultado do Tratamento , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Tronco Encefálico/diagnóstico por imagem , Tronco Encefálico/patologia , Seguimentos , Estudos Retrospectivos
8.
J Magn Reson Imaging ; 37(3): 600-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23060259

RESUMO

PURPOSE: To employ and compare probabilistic diffusion tractography (PDT) for the explicit localization of connections from the thalamus to somatosensory cortex (S1) and primary motor cortex (M1) / supplementary motor area (SMA) with microelectrode electrophysiology in patients undergoing deep brain stimulation (DBS) surgery. MATERIALS AND METHODS: These tractography-derived connections were used to categorize voxels in the thalamus as corresponding to sensory or motor physiology. A novel model (referred to in this work as the "mixture" model) to delineate PDT-based thalamic functional subregions by thresholding fiber intensities, ie, connectivity-defined regions (CDR), was devised. Regions created using this classification method were compared with the most commonly used model (referred to in this work as the "separation" or "winner takes all" model) for defining CDRs. RESULTS: Electrophysiology data corresponded better for S1 CDRs created using the mixture model for both sensory and motor cells. Separation model CDRs showed poor correspondence against electrophysiology, with few sensory cells corresponding to the S1 separation model CDR. CONCLUSION: Mixture model-based CDRs may offer a significant improvement in delineation of functional subregions of subcortical structures.


Assuntos
Estimulação Encefálica Profunda/métodos , Imagem de Tensor de Difusão/métodos , Eletrofisiologia/métodos , Imageamento por Ressonância Magnética/métodos , Córtex Motor/patologia , Tálamo/patologia , Mapeamento Encefálico/métodos , Eletrodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Córtex Motor/fisiologia , Probabilidade , Curva ROC , Reprodutibilidade dos Testes
9.
Science ; 379(6638): 1248-1252, 2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-36952407

RESUMO

Among the diverse areas of 3D printing, high-quality silicone printing is one of the least available and most restrictive. However, silicone-based components are integral to numerous advanced technologies and everyday consumer products. We developed a silicone 3D printing technique that produces precise, accurate, strong, and functional structures made from several commercially available silicone formulations. To achieve this level of performance, we developed a support material made from a silicone oil emulsion. This material exhibits negligible interfacial tension against silicone-based inks, eliminating the disruptive forces that often drive printed silicone features to deform and break apart. The versatility of this approach enables the use of established silicone formulations in fabricating complex structures and features as small as 8 micrometers in diameter.

10.
Neuroimage ; 47 Suppl 2: T44-52, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19362595

RESUMO

DBS depends on precise placement of the stimulating electrode into an appropriate target region. Image-based (direct) targeting has been limited by the ability of current technology to visualize DBS targets. We have recently developed and employed a Fast Gray Matter Acquisition T1 Inversion Recovery (FGATIR) 3T MRI sequence to more reliably visualize these structures. The FGATIR provides significantly better high resolution thin (1 mm) slice visualization of DBS targets than does either standard 3T T1 or T2-weighted imaging. The T1 subcortical image revealed relatively poor contrast among the targets for DBS, though the sequence did allow localization of striatum and thalamus. T2 FLAIR scans demonstrated better contrast between the STN, SNr, red nucleus (RN), and pallidum (GPe/GPi). The FGATIR scans allowed for localization of the thalamus, striatum, GPe/GPi, RN, and SNr and displayed sharper delineation of these structures. The FGATIR also revealed features not visible on other scan types: the internal lamina of the GPi, fiber bundles from the internal capsule piercing the striatum, and the boundaries of the STN. We hope that use of the FGATIR to aid initial targeting will translate in future studies to faster and more accurate procedures with consequent improvements in clinical outcomes.


Assuntos
Encéfalo/patologia , Estimulação Encefálica Profunda/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/cirurgia , Tremor Essencial/patologia , Tremor Essencial/cirurgia , Humanos , Doença de Parkinson/patologia , Doença de Parkinson/cirurgia , Projetos Piloto
11.
Stereotact Funct Neurosurg ; 87(2): 120-7, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19246961

RESUMO

OBJECTIVE: In this paper, the authors review the results of a single-center experience using linear accelerator (LINAC) radiosurgery for the treatment of cavernous sinus meningiomas. METHODS: This is a retrospective analysis with a median follow-up of 50 months. All patients were treated on an outpatient basis. Fifty-five patients were treated and 6 patients were lost to follow-up. Changes in preradiosurgery cranial nerve deficits and symptoms as well as actuarial local tumor control were evaluated. RESULTS: The actuarial local tumor control was 100% at 5 years and 98% at 10 years. One patient had enlargement of tumor. Sixty-five percent had improvement in preradiosurgery cranial nerve deficits, 31% were unchanged and 1 patient (3.5%) was worse. Only 1 patient developed a new neurologic deficit. CONCLUSIONS: This is the largest LINAC radiosurgery experience for cavernous sinus meningiomas reported to date. Radiosurgery appears to offer greatly superior tumor control and much lower morbidity than surgical resection of cavernous sinus meningiomas.


Assuntos
Seio Cavernoso/cirurgia , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Radiocirurgia , Adulto , Idoso , Seio Cavernoso/patologia , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias Meníngeas/patologia , Meningioma/patologia , Pessoa de Meia-Idade , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Adulto Jovem
12.
J Appl Clin Med Phys ; 10(4): 260-272, 2009 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-19918219

RESUMO

Image guided surgery is currently performed using frame-based as well as frameless approaches. In order to reduce the invasive nature of stereotactic guidance as well as to reduce the cost in both equipment and time required within the operating room we investigated the use of rapid prototyping (RP) technology. In our approach we fabricated custom patient specific face-masks and guides that can be applied to the patient during surgery. These guides provide a stereotactic reference for the accurate placement of surgical tools to a pre-planned target along a pre-planned trajectory. While the use of RP machines has previously been shown to be satisfactory for the accuracy standpoint, one of our design criteria, completing the entire built and introduction into the sterile field in less than 120 minutes, was unobtainable. Our primary problems were the fabrication time and the non-resistance of the built material to high-temperature sterilization. In the current study, we have investigated the use of subtractive rapid prototyping (SRP) machines to perform the same quality of surgical guidance while improving the fabrication time and allowing for choosing materials suitable for sterilization. Because SRP technology does not offer the same flexibility as RP in term of prototype shape and complexity, our software program was adapted to provide new guide designs suitable for SRP fabrication. The biopsy guide was subdivided for a more efficient built with the parts being uniquely assembled to form the final guide. The accuracy of the assembly was then assessed using a modified Brown-Roberts-Wells phantom base that allows measuring the position of a biopsy needle introduced into the guide and comparing it with the actual planned target. These tests showed that 1) SRP machines provide an average accuracy of 0.77 mm with a standard deviation of 0.05 mm (plus or minus one image pixel) and 2) SRP allows for fabrication and sterilization within three and a half hours after diagnostic image acquisition and we are confident that that further improvements can reduce this time to less than two hours. Further tests will determine the accuracy of the positioning of the face mask on the patient's head under an IRB-approved trial judged against actual frame-based and frameless systems.


Assuntos
Biópsia por Agulha/instrumentação , Encéfalo/patologia , Neuronavegação/instrumentação , Imagens de Fantasmas/normas , Radiocirurgia/métodos , Técnicas Estereotáxicas/instrumentação , Cirurgia Assistida por Computador/instrumentação , Biópsia por Agulha/métodos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Modelos Biológicos , Neuronavegação/métodos , Radiocirurgia/instrumentação , Software , Cirurgia Assistida por Computador/métodos
13.
Nat Commun ; 10(1): 4016, 2019 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-31488817

RESUMO

Chimeric antigen receptor (CAR) T-cell therapy targeting solid tumors has stagnated as a result of tumor heterogeneity, immunosuppressive microenvironments, and inadequate intratumoral T cell trafficking and persistence. Early (≤3 days) intratumoral presentation of CAR T cells post-treatment is a superior predictor of survival than peripheral persistence. Therefore, we have co-opted IL-8 release from tumors to enhance intratumoral T-cell trafficking through a CAR design for maximal antitumor activity in solid tumors. Here, we demonstrate that IL-8 receptor, CXCR1 or CXCR2, modified CARs markedly enhance migration and persistence of T cells in the tumor, which induce complete tumor regression and long-lasting immunologic memory in pre-clinical models of aggressive tumors such as glioblastoma, ovarian and pancreatic cancer.


Assuntos
Glioblastoma/imunologia , Imunoterapia Adotiva , Interleucina-8/metabolismo , Receptores de Antígenos de Linfócitos T/imunologia , Receptores de Interleucina-8A/metabolismo , Receptores de Interleucina-8B/metabolismo , Linfócitos T/imunologia , Animais , Antígenos de Neoplasias/imunologia , Neoplasias Encefálicas/patologia , Linhagem Celular Tumoral , Proliferação de Células , Citocinas/metabolismo , Modelos Animais de Doenças , Feminino , Glioblastoma/tratamento farmacológico , Glioblastoma/patologia , Humanos , Camundongos Endogâmicos NOD , Microambiente Tumoral/imunologia , Ensaios Antitumorais Modelo de Xenoenxerto
14.
Med Phys ; 35(9): 4262-77, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18841876

RESUMO

This article is a tribute to the pioneering medical physicists over the last 50 years who have participated in the research, development, and commercialization of stereotactic radiosurgery (SRS) and stereotactic radiotherapy utilizing a wide range of technology. The authors have described the evolution of SRS through the eyes of physicists from its beginnings with the Gamma Knife in 1951 to proton and charged particle therapy; modification of commercial linacs to accommodate high precision SRS setups; the multitude of accessories that have enabled fine tuning patients for relocalization, immobilization, and repositioning with submillimeter accuracy; and finally the emerging technology of SBRT. A major theme of the article is the expanding role of the medical physicist from that of advisor to the neurosurgeon to the current role as a primary driver of new technology that has already led to an adaptation of cranial SRS to other sites in the body, including, spine, liver, and lung. SRS continues to be at the forefront of the impetus to provide technological precision for radiation therapy and has demonstrated a host of downstream benefits in improving delivery strategies for conventional therapy as well. While this is not intended to be a comprehensive history, and the authors could not delineate every contribution by all of those working in the pursuit of SRS development, including physicians, engineers, radiobiologists, and the rest of the therapy and dosimetry staff in this important and dynamic radiation therapy modality, it is clear that physicists have had a substantial role in the development of SRS and theyincreasingly play a leading role in furthering SRS technology.


Assuntos
Física Médica/tendências , Radiocirurgia/tendências , Humanos
15.
Am J Clin Oncol ; 41(3): 223-226, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-26650779

RESUMO

OBJECTIVES: To determine the long-term outcome after stereotactic radiosurgery (SRS) for temporal bone paragangliomas. MATERIALS AND METHODS: We retrospectively reviewed the medical records of 11 patients with temporal bone paragangliomas (10 patients with a glomus jugulare tumor and 1 patient with a glomus tympanicum tumor) treated between January 1997 and July 2012 at the University of Florida with SRS to a median dose of 15 Gy in 1 fraction. Ten previously unirradiated patients received SRS as did 1 patient who received prior fractionated radiotherapy (FRT) and then received salvage SRS for a local recurrence. The major outcome endpoint was local control, meaning no further growth or shrinkage on follow-up computed tomography or magnetic resonance imaging scans. RESULTS: The median follow-up time was 5.3 years. Two patients developed a local recurrence after SRS, including the patient who received salvage SRS after prior FRT. The overall local control rates at 5 and 10 years were both 81%. The cause-specific survival rates at 5 and 10 years were both 88%. The distant metastasis-free survival rates at 5 and 10 years were both 100%. The overall survival rates at 5 and 10 years were both 78%. There were no severe complications. CONCLUSIONS: SRS for benign head and neck paragangliomas is a safe and efficacious treatment associated with minimal morbidity. SRS is suitable for patients with skull base tumors <3 cm when FRT is logistically unsuitable. Surgery is reserved for patients in good health whose risk of associated morbidity is low. Observation is a reasonable option for asymptomatic patients with a limited life expectancy.


Assuntos
Paraganglioma Extrassuprarrenal/cirurgia , Radiocirurgia/métodos , Neoplasias Cranianas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paraganglioma Extrassuprarrenal/mortalidade , Radiocirurgia/mortalidade , Estudos Retrospectivos , Neoplasias Cranianas/mortalidade , Osso Temporal/patologia , Resultado do Tratamento
16.
J Neurosurg ; 107(5): 913-6, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17977260

RESUMO

OBJECT: The goal in this study was to review the effects of treatment plan quality on outcomes after radiosurgery for vestibular schwannoma (VS). METHODS: Between July 1988 and August 2005, 390 patients were treated. The results of this experience have been published recently. In this study the authors looked at dosimetry variables: conformity of treatment plan and steepness of dose gradient, in the same group of patients. Over the duration of this study, dosimetry evolved from a single isocenter with marginal conformity to multiple isocenters with high conformity. Multivariate statistics were used to determine the effects of these variables on tumor control and on two types of complication, facial weakness and facial numbness. RESULTS: The 5-year actuarial tumor control was 91%. Dosimetry had no effect on tumor control. Eighteen patients (4.6%) reported new-onset facial weakness and 14 (3.6%) reported new-onset facial numbness. Since 1994, when peripheral treatment doses were lowered to 1250 cGy, only three (1%) of 298 patients have experienced facial weakness and two (0.7%) of 298 have experienced facial numbness. Statistical analysis confirms, as in the prior study, that treatment volume and treatment dose are significant predictors of both facial weakness and facial numbness. In this model, prior tumor growth was also significant. Dosimetry, however, is definitely not a significant predictor of either complication. CONCLUSIONS: Treatment dose appears to be much more important than treatment plan quality in the prevention of facial numbness or weakness after radiosurgery for VS.


Assuntos
Neuroma Acústico/cirurgia , Planejamento de Assistência ao Paciente/normas , Radiocirurgia/métodos , Doenças do Nervo Facial/etiologia , Humanos , Complicações Pós-Operatórias , Radiometria
17.
Med Dosim ; 32(2): 111-20, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17472890

RESUMO

The last decade has seen the introduction of advanced technologies that have enabled much more precise application of therapeutic radiation. These relatively new technologies include multileaf collimators, 3-dimensional conformal radiotherapy planning, and intensity modulated radiotherapy in radiotherapy. Therapeutic dose distributions have become more conformal to volumes of disease, sometimes utilizing sharp dose gradients to deliver high doses to target volumes while sparing nearby radiosensitive structures. Thus, accurate patient positioning has become even more important, so that the treatment delivered to the patient matches the virtual treatment plan in the computer treatment planning system. Optical and image-guided radiation therapy systems offer the potential to improve the precision of patient treatment by providing a more robust fiducial system than is typically used in conventional radiotherapy. The ability to accurately position internal targets relative to the linac isocenter and to provide real-time patient tracking theoretically enables significant reductions in the amount of normal tissue irradiated. This report reviews the concepts, technology, and clinical applications of optical tracking systems currently in use for stereotactic radiation therapy. Applications of radiotherapy optical tracking technology to respiratory gating and the monitoring of implanted fiducial markers are also discussed.


Assuntos
Raios Infravermelhos , Radiocirurgia/métodos , Cirurgia Assistida por Computador/métodos , Humanos , Neoplasias/radioterapia , Óptica e Fotônica
18.
Neurosurg Clin N Am ; 28(4): 585-594, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28917286

RESUMO

Spinal instrumentation often involves placing implants without direct visualization of their trajectory or proximity to adjacent neurovascular structures. Two-dimensional fluoroscopy is commonly used to navigate implant placement, but with the advent of computed tomography, followed by the invention of a mobile scanner with an open gantry, three-dimensional (3D) navigation is now widely used. This article critically appraises the available literature to assess the influence of 3D navigation on radiation exposure, accuracy of instrumentation, operative time, and patient outcomes. Also explored is the latest technological advance in 3D neuronavigation: the manufacturing of, via 3D printers, patient-specific templates that direct implant placement.


Assuntos
Imageamento Tridimensional/métodos , Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X/métodos , Fluoroscopia/métodos , Humanos , Cirurgia Assistida por Computador/métodos
19.
J Neurosurg ; 104(6 Suppl): 392-5, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16776374

RESUMO

OBJECT: Frameless neuronavigation has been established as a useful adjunct to intracranial surgery; however, the procedure is limited in young children by the need for rigid skull fixation with pins. Pin fixation is difficult and hazardous for patients younger than 2 years of age. Minor risks have been associated with pin fixation in older patients also, including scalp laceration, skull fracture, and epidural hematoma. METHODS: The authors adapted a pinless head fixation system, consisting of a beanbag device, for use with frameless neuronavigation. This system was used to perform intracranial neurosurgical procedures in nine patients. CONCLUSIONS: This pinless, frameless method provides a new option for children who are unable to sustain rigid head fixation. It is also an alternative to rigid pin fixation for patients of any age.


Assuntos
Encefalopatias/cirurgia , Craniotomia , Neuroendoscopia , Neuronavegação/instrumentação , Ventriculostomia , Adolescente , Adulto , Fatores Etários , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Resultado do Tratamento
20.
J Neurosurg ; 105(5): 657-61, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17121123

RESUMO

OBJECT: Radiosurgery has become a popular treatment for small vestibular schwannomas (VSs). The aim of this study was to review an extensive, single-institution experience with linear accelerator (LINAC) radiosurgery for VSs. METHODS: Between July 1988 and August 2005, 390 patients with VSs were treated with LINAC-based radiosurgery at the authors' institution. Patient and treatment variables were prospectively maintained in a computer database. Outcomes were tracked through periodic clinical examinations and annual scanning studies. Multivariate and actuarial statistics were used to analyze rates of local tumor control and complications, including facial and trigeminal neuropathies, after treatment. One- and 2-year actuarial control rates were both 98%, and the 5-year actuarial control rate was 90%. Only four patients (1%) required surgery for tumor growth. Seventeen patients (4.4%) reported facial weakness and 14 patients (3.6%) reported facial numbness after radiosurgery. The risk of these complications rose with increasing tumor volume or increasing radiosurgical dose to the tumor periphery. Since 1994, when doses were deliberately lowered to 1250 cGy, only two patients (0.7%) have experienced facial weakness and two (0.7%) have experienced facial numbness. CONCLUSIONS: Radiosurgery provides a safe and effective therapeutic alternative to surgery for small VSs.


Assuntos
Neuroma Acústico/cirurgia , Radiocirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Paralisia Facial/etiologia , Feminino , Seguimentos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Neuroma Acústico/patologia , Modelos de Riscos Proporcionais , Radiocirurgia/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA