Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
N Engl J Med ; 389(13): 1180-1190, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37754283

RESUMO

BACKGROUND: Randomized, controlled trials have shown both benefit and harm from tight blood-glucose control in patients in the intensive care unit (ICU). Variation in the use of early parenteral nutrition and in insulin-induced severe hypoglycemia might explain this inconsistency. METHODS: We randomly assigned patients, on ICU admission, to liberal glucose control (insulin initiated only when the blood-glucose level was >215 mg per deciliter [>11.9 mmol per liter]) or to tight glucose control (blood-glucose level targeted with the use of the LOGIC-Insulin algorithm at 80 to 110 mg per deciliter [4.4 to 6.1 mmol per liter]); parenteral nutrition was withheld in both groups for 1 week. Protocol adherence was determined according to glucose metrics. The primary outcome was the length of time that ICU care was needed, calculated on the basis of time to discharge alive from the ICU, with death accounted for as a competing risk; 90-day mortality was the safety outcome. RESULTS: Of 9230 patients who underwent randomization, 4622 were assigned to liberal glucose control and 4608 to tight glucose control. The median morning blood-glucose level was 140 mg per deciliter (interquartile range, 122 to 161) with liberal glucose control and 107 mg per deciliter (interquartile range, 98 to 117) with tight glucose control. Severe hypoglycemia occurred in 31 patients (0.7%) in the liberal-control group and 47 patients (1.0%) in the tight-control group. The length of time that ICU care was needed was similar in the two groups (hazard ratio for earlier discharge alive with tight glucose control, 1.00; 95% confidence interval, 0.96 to 1.04; P = 0.94). Mortality at 90 days was also similar (10.1% with liberal glucose control and 10.5% with tight glucose control, P = 0.51). Analyses of eight prespecified secondary outcomes suggested that the incidence of new infections, the duration of respiratory and hemodynamic support, the time to discharge alive from the hospital, and mortality in the ICU and hospital were similar in the two groups, whereas severe acute kidney injury and cholestatic liver dysfunction appeared less prevalent with tight glucose control. CONCLUSIONS: In critically ill patients who were not receiving early parenteral nutrition, tight glucose control did not affect the length of time that ICU care was needed or mortality. (Funded by the Research Foundation-Flanders and others; TGC-Fast ClinicalTrials.gov number, NCT03665207.).


Assuntos
Glicemia , Estado Terminal , Controle Glicêmico , Insulina , Humanos , Glicemia/análise , Glucose/análise , Hipoglicemia/induzido quimicamente , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Unidades de Terapia Intensiva , Controle Glicêmico/efeitos adversos , Controle Glicêmico/métodos , Nutrição Parenteral , Algoritmos , Estado Terminal/terapia
2.
Sci Rep ; 12(1): 14911, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050354

RESUMO

Transcutaneous medium-frequency alternating electrical current is defined as an alternating current between 1 and 10 kHz and is capable of producing an instant, reversible block. This study aims to evaluate the efficacy of sensory perception and force production of the index and middle finger after transcutaneous medium-frequency alternating electrical current stimulation of the distal median nerve. A single-center prospective interventional cohort study was conducted in adult healthy volunteers at the Jessa Hospital, Hasselt, Belgium. Two different electrodes (PALS & 3M) were placed on the distal median nerve, which was located using a Sonosite X-Porte Ultrasound transducer, with the first electrode being placed on the skin at the level of the transverse carpal ligament and the second electrode 7 cm proximally to the first electrode. The tactile sensation was evaluated with Semmes-Weinstein monofilament test and sensation of pressure/pain was evaluated with an algometer. Peak force production was assessed with an electronic dynamometer. All measurements were performed at baseline and tMFAEC stimulation frequencies of 2 and 10 kHz in a randomized manner. Statistical analysis was performed with a one-way ANOVA with repeated measures test or a Friedman rank sum test, followed by the Wilcoxon signed rank test adjusted with Bonferroni correction. A p-value < 0.05 was considered statistically significant. From 9 to 13th of April 2021, 25 healthy volunteers were included in the Jessa Hospital, Hasselt, Belgium. A statistically significant reduction in tactile sensation during 2 kHz and 10 kHz stimulation compared to baseline was observed (2.89 ± 0.22 (PALS2); 3.35 ± 0.25 (3M2) and 2.14 ± 0.12 (PALS10); 2.38 ± 0.12 (3M10) versus - 1.75 ± 0.09 (baseline), p < 0.0001). 3M electrodes showed a tendency towards the elevation of pressure pain threshold compared to baseline. No significant difference in mean peak forces of the index and middle fingers after transcutaneous medium-frequency alternating electrical current stimulation with 2 and 10 kHz was found. This study demonstrates that transcutaneous medium-frequency alternating electrical current stimulation on the distal median nerve inhibits tactile sensory nerve activity in the index and middle finger when stimulation of 2 kHz and, to a lesser extent, 10 kHz was applied. A reduction of motor nerve activity was not observed but force production measurements may be prone to error.Trial registration: clinicaltrials.gov on 01/04/2021. NCT-Number: NCT04827173.


Assuntos
Estimulação Elétrica Nervosa Transcutânea , Adulto , Estudos de Coortes , Humanos , Nervo Mediano/fisiologia , Dor , Limiar da Dor/fisiologia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA