Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Heart Fail Rev ; 29(3): 615-630, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38289525

RESUMO

Acute decompensated heart failure and fluid overload are the most common causes of hospitalization in heart failure patients, and often, they contribute to disease progression. Initial treatment encompasses intravenous diuretics although there might be a percentual of patients refractory to this pharmacological approach. New technologies have been developed to perform extracorporeal ultrafiltration in fluid overloaded patients. Current equipment allows to perform ultrafiltration in most hospital and acute care settings. Extracorporeal ultrafiltration is then prescribed and conducted by specialized teams, and fluid removal is planned to restore a status of hydration close to normal. Recent clinical trials and European and North American practice guidelines suggest that ultrafiltration is indicated for patients with refractory congestion not responding to medical therapy. Close interaction between nephrologists and cardiologists may be the key to a collaborative therapeutic effort in heart failure patients. Further studies are today suggesting that wearable technologies might become available soon to treat patients in ambulatory and de-hospitalized settings. These new technologies may help to cope with the increasing demand for the care of chronic heart failure patients. Herein, we provide a state-of-the-art review on extracorporeal ultrafiltration and describe the steps in the development of a new miniaturized system for ultrafiltration, called AD1 (Artificial Diuresis).


Assuntos
Insuficiência Cardíaca , Ultrafiltração , Humanos , Insuficiência Cardíaca/terapia , Ultrafiltração/métodos , Ultrafiltração/instrumentação , Miniaturização , Desenho de Equipamento , Hemofiltração/instrumentação , Hemofiltração/métodos
2.
Blood Purif ; 53(10): 773-780, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39068927

RESUMO

INTRODUCTION: Enkephalins, endogenous opioid peptides, are involved in the regulation of renal function. One derived molecule, proenkephalin A, also known as penKid, has been demonstrated to be a reliable biomarker for kidney function and its plasma concentration correlates with measured glomerular filtration rate. penKid is used for prediction and diagnosis of AKI and need of renal replacement therapy (RRT). penKid has also been used to predict the successful weaning from RRT in patients with AKI. Whether the concentration of penKid is affected or not by RRT is a controversial point and there are no studies describing the kinetics of the molecule in such conditions. The low molecular weight (4.5 kDa) would imply free removal by the glomerulus and the dialysis membranes. During RRT, this reduction could not be detected in clinical practice due to the complex kinetics involving either low dialytic clearance or increased production in response to impaired kidney function. The aim of this study was to determine the sieving coefficient and the diffusive clearance of the penKid molecule in conditions of in vitro continuous veno-venous hemofiltration (CVVH) and continuous veno-venous hemodialysis (CVVHD), respectively, and also the penKid removal ratio in conditions of in vitro hemoadsorption (HA) using a synthetic microporous resin. METHODS: Blood spiked with a lyophilized penKid peptide solved in 20 mm dipotassium phosphate and 6 mm disodium EDTA [pH 8] to reach target concentrations is used as testing solution. In each experiment, the blood batch was adjusted at a volume of 1,000 mL, maintained at 37°, and continuously stirred. Samples were collected from blood, ultrafiltrate, and spent dialysate at different times during the experiments. Sieving, clearance, and removal ratio were calculated. RESULTS: Significant removal of penKid was observed in CVVH (sieving 1.04 ± 0.27), in CVVHD (clearance 23.08 ± 0.89), and in HA (removal ratio 76.1 ± 1% after 120 min). CONCLUSION: penKid is effectively removed by extracorporeal therapies. In presence of anuria, penKid generation kinetics can be calculated based on extracorporeal removal and volume variation. In steady state conditions, declining values may be the result of an initial renal function recovery and may suggest discontinuation and successful liberation from RRT.


Assuntos
Encefalinas , Precursores de Proteínas , Humanos , Encefalinas/sangue , Precursores de Proteínas/sangue , Cinética , Hemofiltração/métodos , Diálise Renal/métodos , Terapia de Substituição Renal Contínua/métodos , Adsorção , Injúria Renal Aguda/terapia , Injúria Renal Aguda/sangue , Fragmentos de Peptídeos/sangue
3.
Blood Purif ; 53(8): 613-623, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38493768

RESUMO

INTRODUCTION: Per- and polyfluoroalkyl substances (PFAS) are known water pollutants leading to potential public health consequences. High blood levels of PFAS have been associated with several pathological conditions including testicular and kidney cancer. Classic extracorporeal therapies have demonstrated limited efficiency, and new approaches should be explored. In this study, we studied the possible role of hemoadsorption to achieve a fast, safe, and effective removal of PFAS from blood in patients with high blood levels. METHODS: We developed an in vitro model of hemoadsorption to test the potential of PFAS removal by extracorporeal treatment. We recirculated a highly polluted batch of water (4 L) through a sorbent cartridge (Jafron Medical, Zhuhai, China) for 120 min at a flow of 150 mL/min. We collected samples at different time points and analyzed 39 different PFAS compounds. RESULTS: For the PFAS compounds with concentrations significantly above normal, we observed a removal ratio close to 90% already within the first 60 min of circulation leading to almost complete elimination of all pollutants at 120 min. CONCLUSIONS: The in vitro model of hemoadsorption suggests the possible application in vivo of this technique to reduce/normalize the concentrations of PFAS in patients exposed to water or environmental pollution.


Assuntos
Fluorocarbonos , Humanos , Fluorocarbonos/sangue , Poluentes Químicos da Água/sangue , Cinética , Adsorção , Purificação da Água/métodos
4.
Blood Purif ; 51(11): 912-922, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35263746

RESUMO

INTRODUCTION: At the time of renal replacement therapy, approximately 20% of critically ill patients have septic shock. In this study, medium cutoff (MCO) continuous venovenous hemodialysis (CVVHD) was compared to high-flux membrane continuous venovenous hemodiafiltration (CVVHDF) in terms of hemodynamic improvement, efficiency, middle molecule removal, and inflammatory system activation. METHODS: This is a monocenter crossover randomized study. Between December 31, 2017, and December 31, 2019, 20 patients with septic shock and stage 3 acute kidney injury (AKI) admitted to 2 Italian ICUs were enrolled. All patients underwent CVVHD with Ultraflux® EMiC®2 and CVVHDF with AV1000S® without washout. Each treatment lasted 24 h. RESULTS: Compared to AV1000S®-CVVHDF, EMIC®2-CVVHD normalized cardiac index (ß = -0.64; p = 0.02) and heart rate (ß = 5.72; p = 0.01). Interleukin-8 and myeloperoxidase removal were greater with AV1000S®-CVVHDF than with EMiC®2-CVVHD (ß = 0.35; p < 0.001; ß = 0.43; p = 0.03, respectively). Leukocytosis improved over 24 h in EMiC®2-CVVHD-treated patients (ß = 4.13; p = 0.03), whereas procalcitonin levels decreased regardless of the modality (ß = 0.89; p = 0.01) over a 48-h treatment period. Reduction rates, instantaneous plasmatic clearance of urea, creatinine, and ß2-microglobulin were similar across modalities. ß2-Microglobulin removal efficacy was greater in the EMiC®2 group (ß = 0-2.88; p = 0.002), while albumin levels did not differ. Albumin was undetectable in the effluent in both treatments. DISCUSSION: In patients with septic shock and severe AKI, the efficacy of uremic toxin removal was comparable between MCO-CVVHD and CVVHDF. Further, MCO-CVVHD was associated with improved hemodynamics. Fraction of filtration and transmembrane pressure reduction and the maintenance of equal efficacy might be the key features of CVVHD with MCO membranes in critically ill patients.


Assuntos
Injúria Renal Aguda , Terapia de Substituição Renal Contínua , Hemodiafiltração , Choque Séptico , Humanos , Choque Séptico/terapia , Choque Séptico/etiologia , Estado Terminal , Diálise Renal , Injúria Renal Aguda/terapia , Albuminas , Hemodiafiltração/efeitos adversos
5.
Clin Chem Lab Med ; 59(2): 333-342, 2020 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-32986608

RESUMO

Objectives: Identification of acute kidney injury (AKI) can be challenging in patients with a variety of clinical features at intensive care unit (ICU) admission, and the capacity of biomarkers in this subpopulation has been poorly studied. In our study we examined the influence that patients' clinical features at ICU admission have over the predicting ability of the combination of urinary tissue inhibitor of metalloproteinase-2 (TIMP2) and insulin-like growth factor binding protein 7 (IGFBP7). Methods: Urinary [TIMP2]•[IGFBP7] were measured for all patients upon admission to ICU. We calculated the receiver operating characteristics (ROC) curves for AKI prediction in the overall cohort and for subgroups of patients according to etiology of ICU admission, which included: sepsis, trauma, neurological conditions, cardiovascular diseases, respiratory diseases, and non-classifiable causes. Results: In the overall cohort of 719 patients, 239 (33.2%) developed AKI in the first seven days. [TIMP2]•[IGFBP7] at ICU admission were significantly higher in AKI patients than in non-AKI patients. This is true not only for the overall cohort but also in the other subgroups. The area under the ROC curve (AUC) for [TIMP2]•[IGFBP7] in predicting AKI in the first seven days was 0.633 (95% CI 0.588-0.678), for the overall cohort, with sensitivity and specificity of 66.1 and 51.9% respectively. When we considered patients with combined sepsis, trauma, and respiratory disease we found a higher AUC than patients without these conditions (0.711 vs. 0.575; p=0.002). Conclusions: The accuracy of [TIMP2]•[IGFBP7] in predicting the risk of AKI in the first seven days after ICU admission has significant variability when the reason for ICU admission is considered.


Assuntos
Injúria Renal Aguda/diagnóstico , Biomarcadores/análise , Pontos de Checagem do Ciclo Celular/fisiologia , Unidades de Terapia Intensiva/normas , Idoso , Estudos de Coortes , Feminino , Hospitalização , Humanos , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/sangue , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/urina , Masculino , Pessoa de Meia-Idade , Curva ROC , Medição de Risco , Sensibilidade e Especificidade , Inibidor Tecidual de Metaloproteinase-2/sangue , Inibidor Tecidual de Metaloproteinase-2/urina
6.
Kidney Int ; 95(6): 1486-1493, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30982674

RESUMO

The G1 cell cycle inhibitors tissue inhibitor metalloproteinase-2 (TIMP-2) and insulin-like growth factor-binding protein 7 (IGFBP7) have been identified as novel biomarkers for the prediction of moderate to severe acute kidney injury (AKI) risk. However, the prognostic value of [TIMP-2]•[IGFBP7] in predicting adverse outcomes in intensive care unit (ICU) patients with AKI was not previously described. To evaluate this, we conducted a cohort study, measuring [TIMP2]•[IGFBP7] levels in critically ill patients admitted to the ICU and classified the patients as NephroCheck (NC) (+) or NC (-) according to [TIMP-2]•[IGFBP7] values and AKI (+) or AKI (-) according to Kidney Disease: Improving Global Outcomes (KDIGO) criteria. We then evaluated the incidence of continuous renal replacement therapy initiation, all-cause mortality and a composite endpoint of both in the four groups. Baseline [TIMP-2]•[IGFBP7] values were available for 719 patients, of whom 239 developed AKI and 151 met the composite endpoint. Compared to NC (-)/AKI (+) patients, NC (+)/AKI (+) patients had a significant risk of ICU mortality and the composite endpoint. Kaplan-Meier curves showed that the survival estimate for the composite endpoint of NC (+)/AKI (+) patients was 34.4%; significantly worse than NC (-)/AKI (+) patients (67.4%). Multivariate analyses showed strong association between NC positivity and the composite endpoint. The inflammatory marker, procalcitonin, was an additional prognostic biomarker to compare and confirm the incremental value of NephroCheck. No association between procalcitonin and the composite endpoint was found, especially in patients with AKI, suggesting that NephroCheck may be more kidney specific. Thus, the [TIMP-2]•[IGFBP7] values can serve to identify patients with AKI at increased risk for adverse outcomes in the ICU.


Assuntos
Injúria Renal Aguda/diagnóstico , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/sangue , Unidades de Terapia Intensiva/estatística & dados numéricos , Inibidor Tecidual de Metaloproteinase-2/sangue , Injúria Renal Aguda/sangue , Injúria Renal Aguda/mortalidade , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Estudos de Viabilidade , Feminino , Mortalidade Hospitalar , Humanos , Itália/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Curva ROC , Terapia de Substituição Renal/estatística & dados numéricos , Medição de Risco/métodos , Índice de Gravidade de Doença
7.
Nephrol Dial Transplant ; 34(2): 308-317, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30053231

RESUMO

Background: Cardiac surgery is a leading cause of acute kidney injury (AKI). Such AKI patients may develop progressive chronic kidney disease (CKD). Others, who appear to have sustained no permanent loss of function (normal serum creatinine), may still lose renal functional reserve (RFR). Methods: We extended the follow-up in the observational 'Preoperative RFR Predicts Risk of AKI after Cardiac Surgery' study from hospital discharge to 3 months after surgery for 86 (78.2%) patients with normal baseline estimated glomerular filtration rate (eGFR), and re-measured RFR with a high oral protein load. The primary study endpoint was change in RFR. Study registration at clinicaltrials.gov Identifier: NCT03092947, ISRCTN Registry: ISRCTN16109759. Results: At 3 months, three patients developed new CKD. All remaining patients continued to have a normal eGFR (93.3 ± 15.1 mL/min/1.73 m2). However, when stratified by post-operative AKI and cell cycle arrest (CCA) biomarkers, AKI patients displayed a significant decrease in RFR {from 14.4 [interquartile range (IQR) 9.5 - 24.3] to 9.1 (IQR 7.1 - 12.5) mL/min/1.73 m2; P < 0.001} and patients without AKI but with positive post-operative CCA biomarkers also experienced a similar decrease of RFR [from 26.7 (IQR 22.9 - 31.5) to 19.7 (IQR 15.8 - 22.8) mL/min/1.73 m2; P < 0.001]. In contrast, patients with neither clinical AKI nor positive biomarkers had no such decrease of RFR. Finally, of the three patients who developed new CKD, two sustained AKI and one had positive CCA biomarkers but without AKI. Conclusions: Among elective cardiac surgery patients, AKI or elevated post-operative CCA biomarkers were associated with decreased RFR at 3 months despite normalization of serum creatinine. Larger prospective studies to validate the use of RFR to assess renal recovery in combination with biochemical biomarkers are warranted.


Assuntos
Injúria Renal Aguda/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiopatias/complicações , Cardiopatias/cirurgia , Insuficiência Renal Crônica/etiologia , Biomarcadores/sangue , Creatinina/sangue , Feminino , Seguimentos , Taxa de Filtração Glomerular , Humanos , Rim/fisiopatologia , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Período Pós-Operatório , Estudos Prospectivos
8.
Blood Purif ; 47(1-3): 270-276, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30522094

RESUMO

BACKGROUND: Sepsis is a life-threatening condition often associated with a high incidence of multiple organs injury. Several papers suggested the immune response by itself, with the production of humoral inflammatory mediators, is crucial in determining organ injury. However, little is known of how sepsis directly induces organ injury at the cellular levels. To assess this point, we set up an in vitro study to investigate the response of renal tubular cells (RTCs), monocytes (U937) and hepatocytes (HepG2) after 24 h-incubation with septic patients' plasma. METHODS: We enrolled 26 septic patients ("test" group). We evaluated cell viability, apoptosis and necrosis by flow cytometer. Caspase-3,-8,-9 and cytochrome-c concentrations have been analyzed using the Human enzyme-linked immunosorbent assay kit. RESULTS: We found that a decrease of cell viability in all cell lines tested was associated to the increase of apoptosis in RTCs and U937 (p < 0.0001) and increase of necrosis in HepG2 (p < 0.5). The increase of apoptosis in RTCs and U937 cells was confirmed by higher levels of caspase-3 (p < 0.0001). We showed that apoptosis in both RTCs and U937 was triggered by the activation of the intrinsic pathway, as caspase-9 and cytochrome-c levels significantly increased (p < 0.0001), while caspase-8 did not change. This assumption was strengthened by the significant correlation of caspase-9 with both cytochrome-c (r = 0.73 for RTCs and r = 0.69 for U937) and caspase-3 (r = 0.69 for RTCs and r = 0.63 for U937). CONCLUSION: Humoral mediators in septic patients' plasma induce apoptosis. This fact suggests that apoptosis inhibitors should be investigated as future strategy to reduce sepsis-induced organ damages.


Assuntos
Apoptose , Hepatócitos/metabolismo , Túbulos Renais Proximais/metabolismo , Monócitos/metabolismo , Plasma , Sepse/sangue , Caspases/metabolismo , Sobrevivência Celular , Citocromos c/metabolismo , Células Hep G2 , Hepatócitos/patologia , Humanos , Túbulos Renais Proximais/patologia , Monócitos/patologia , Células U937
9.
Blood Purif ; 48(1): 60-66, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30712031

RESUMO

BACKGROUND: ACUsmart (Medica S.P.A., Italy) is a new-generation, continuous renal replacement therapy (CRRT) machine for critically ill patients with acute kidney injury. We designed a multicenter international pilot study to provide a description of outlines of the ACUsmart system, evaluation aspects of functionality, usability, and feasibility, discriminating reasons of possible treatment's withdrawals or discontinuations and highlighting strong and weak points of the machine. METHODS: Data of 23 CRRT (and 11 plasma exchange) treatments were collected from 4 intensive care units. Parameters such as treatment duration, downtime, delivered dose, and number and type of alarms were recorded. The general perception of the machine was quantified through the administration of a survey to each component of the evaluating staff. RESULTS: A total treatment time of 447 h was carried with ACUsmart. Eleven continuous veno-venous hemofiltration, 4 continuous veno-venous hemodialysis , and 8 continuous veno-venous hemodiafiltration were performed. The average percentage of net treatment duration with respect to total treatment duration was 92.37%. The mean prescribed dose and delivered dose were 26.33 and 24.10 mL/kg/h, respectively. In general, the machine was rated by users involved as practical and easy to use, although few components need to be slightly improved. CONCLUSION: ACUsmart is a new multifunctional machine that meets most of the features required in a fourth-generation CRRT equipment.


Assuntos
Injúria Renal Aguda/terapia , Estado Terminal/terapia , Terapia de Substituição Renal/instrumentação , Terapia de Substituição Renal/métodos , Humanos , Projetos Piloto , Terapia de Substituição Renal/efeitos adversos , Projetos de Pesquisa , Resultado do Tratamento , Interface Usuário-Computador
10.
Blood Purif ; 47(1-3): 140-148, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30336490

RESUMO

Backgound: This study was aimed at evaluating the presepsin and procalcitonin levels to predict adverse postoperative complications and mortality in cardiac surgery patients. METHODS: A total of 122 cardiac surgery patients were enrolled for the study. Presepsin and procalcitonin levels were measured 48 h after the procedure. The primary endpoints were adverse renal, respiratory, and cardiovascular outcomes and mortality. RESULTS: Presepsin and procalcitonin levels were significantly higher in patients with adverse renal and respiratory outcome (p < 0.001 and 0.0081). The presepsin levels were significantly higher in patients with adverse cardiovascular outcome (p = 0.023) and the procalcitonin values in patients with sepsis (p = 0.0013). Presepsin levels were significantly higher in patients who died during hospitalization (382 pg/mL, interquartile range [IQR] 243-717.5 vs. 1,848 pg/mL, IQR 998-5,451.5, p = 0.049). In addition, the predictive value for in-hospital, 30-days, and 6-months mortality was higher for presepsin, with a significant difference between the 2 biomarkers (p = 0.025, p = 0.035, p = 0.003; respectively). Presepsin and procalcitonin seem to have comparable predictive value for adverse renal, cardiovascular, and respiratory outcome in cardiac surgery patients. Although a positive trend was notable for presepsin and adverse renal outcome (area under the ROC [receiver operating characteristic] curves [AUC] of 0.760, 95% CI 0.673-0.833 versus procalcitonin: AUC 0.692; 95% CI 0.601-0.773): no statistically significant difference was evident between the AUC of the 2 biomarkers (p = 0.25). CONCLUSIONS: Presepsin and -procalcitonin seem to have comparable predictive value for -adverse renal, cardiovascular, and respiratory outcome in cardiac surgery patients. Also, presepsin possesses a better predictive value for in-hospital, 30-days, and 6-months mortality.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Mortalidade Hospitalar , Receptores de Lipopolissacarídeos/sangue , Fragmentos de Peptídeos/sangue , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/mortalidade , Pró-Calcitonina/sangue , Idoso , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
11.
Nephrol Dial Transplant ; 33(suppl_3): iii41-iii47, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30281134

RESUMO

Recent advances in chemical composition and new production techniques resulted in improved biocompatibility and permeability of dialysis membranes. Among these, the creation of a new class of membranes called medium cut-off (MCO) represents an important step towards improvement of clinical outcomes. Such membranes have been developed to improve the clearance of medium to high molecular weight (MW) solutes (i.e. uraemic toxins in the range of 5-50 kDa). MCO membranes have peculiar retention onset and cut-off characteristics. Due to a modified sieving profile, MCO membranes have also been described as high-retention onset. The significant internal filtration achieved in MCO haemodialysers provides a remarkable convective clearance of medium to high MW solutes. The marginal loss of albumin observed in MCO membranes compared with high cut-off membranes is considered acceptable, if not beneficial, producing a certain clearance of protein-bound solutes. The application of MCO membranes in a classic dialysis modality characterizes a new technique called expanded haemodialysis. This therapy does not need specific software or dedicated hardware, making its application possible in every setting where the quality of dialysis fluid meets current standards.


Assuntos
Hemodiafiltração/instrumentação , Membranas Artificiais , Diálise Renal/instrumentação , Diálise Renal/métodos , Soluções para Diálise , Hemodiafiltração/métodos , Humanos , Peso Molecular
12.
Blood Purif ; 45(1-3): 278-283, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29478068

RESUMO

Arteriovenous fistula cannulation for dialysis treatments in Europe has traditionally been done by metal needles. In -Japan, plastic cannulas have been available for many years and are used in the majority of the dialysis patients. The mechanical structure and the cannulation procedure of the plastic cannulas differ from those of the metal needles. These differences are particularly beneficial for patients with delicate fistulas, tortuous vessels, metal allergies, oligophrenic patients, and also for the safety of the medical staff. In this paper, we present the main features of a novel fistula plastic cannula and the innovations introduced by it compared to the traditional metal needles.


Assuntos
Cateterismo/instrumentação , Segurança , Dispositivos de Acesso Vascular , Cateterismo/efeitos adversos , Cateterismo/métodos , Europa (Continente) , Humanos , Japão
13.
Blood Purif ; 46(3): 196-204, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29886489

RESUMO

BACKGROUND: Inadequate removal of molecules between 5 and 50 KDa may cause long-term complication in chronic hemodialysis. Medium cut-off (MCO) is a new class of membranes with enhanced sieving properties and negligible albumin loss. MCO membrane makes it possible to perform expanded hemodialysis (HDx), a technique based on high internal filtration (IF).The present study is designed to quantify IF in 2 MCO dialyzers (Theranova 400 and 500, Baxter, Deerfield, USA) using a nuclear imaging technique previously validated. METHODS: Blood and dialysate compartment pressure drop along with transmembrane pressure; they were measured in a closed in vitro circuit with human blood (blood flow [QB] = 300 and 400 mL/min; dialysate flow 500 mL/min; net ultrafiltration rate 0 mL/min). A non-diffusible marker molecule (albumin macro-aggregates labeled with 99Tc metastable) was injected in the blood compartment and nuclear emission was recorded by a gamma camera. Relative variations in the concentration of the marker molecule along the length of the filter were used to calculate local cross filtration. RESULTS: Based on marker concentration profiles, IF was estimated. For Theranova 400, IF were 29.7 and 41.6 mL/min for QB of 300 and 400 mL/min. For Theranova 500, IF were 31.6 and 53.1 mL/min for QB of 300 and 400 mL/min respectively. CONCLUSIONS: MCO membrane provides significant amounts of IF due to the particular combination between hydraulic permeability of the membrane and reduced inner diameter of the fibers. High IF combined with enhanced sieving profile of MCO membrane leads to improved removal of a wider spectrum of uremia retention molecules in HDx, without requiring complex equipment.


Assuntos
Membranas Artificiais , Diálise Renal/instrumentação , Filtração , Humanos , Diálise Renal/métodos
14.
Blood Purif ; 45(1-3): 270-277, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29478052

RESUMO

BACKGROUND: Acute kidney injury (AKI) diagnosis is based on a rise in serum creatinine and/or fall in urine output. It has been shown that there are patients that fulfill AKI definition but do not have AKI, and there are also patients with evidence of renal injury who do not meet any criteria for AKI. Recently the innovative and emerging proteomic technology has enabled the identification of novel biomarkers that allow improved risk stratification. METHODS: Tissue inhibitor of metalloproteinases-2 (TIMP-2), insulin-like growth factor-binding protein 7 (IGFBP7) were measured to a cohort of 719 consecutive patients admitted to Intensive Care Unit (ICU). The primary endpoint was the evaluation of clinical performances of the biomarkers focusing on the probability do develop AKI in the first 7 days. RESULTS: The Kaplan-Meier analysis considering the first 7 days of ICU stay suggested a lower risk of developing AKI (p < 0.0001) for patients with a negative (<0.3; TIMP-2*IGFBP7) test. CONCLUSION: (TIMP-2*IGFBP7) at ICU admission has a good performance in predicting AKI, especially in the first 4 days in ICU.


Assuntos
Injúria Renal Aguda/sangue , Injúria Renal Aguda/mortalidade , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/sangue , Unidades de Terapia Intensiva , Inibidor Tecidual de Metaloproteinase-2/sangue , Idoso , Biomarcadores/sangue , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taxa de Sobrevida
15.
Crit Care ; 20: 95, 2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-27060079

RESUMO

BACKGROUND: Studies have demonstrated a positive correlation between fluid overload (FO) and adverse outcomes in critically ill patients. The present study aims at defining the impact of hyperhydration on the Intensive Care Unit (ICU) mortality risk, comparing Bioelectrical Impedance Vector Analysis (BIVA) assessment with cumulative fluid balance (CFB) recording. METHODS: We performed a prospective, dual-centre, clinician-blinded, observational study of consecutive patients admitted to ICU with an expected length of ICU stay of at least 72 hours. During observational period (72-120 hours), CFB was recorded and cumulative FO was calculated. At the admission and daily during the observational period, BIVA was performed. We considered FO between 5% and 9.99% as moderate and a FO ≥ 10% as severe. According to BIVA hydration scale of lean body mass, patients were classified as normohydrated (>72.7%-74.3%), mild (>71%-72.7%), moderate (>69%-71%) and severe (≤ 69%) dehydrated and mild (>74.3%-81%), moderate (>81%-87%) and severe (>87%) hyperhydrated. Two multivariate logistic regression models were performed: the ICU mortality was the response variable, while the predictor variables were hyperhydration, measured by BIVA (BIVA model), and FO (FO model). A p-value <0.05 was considered to indicate statistical significance. RESULTS: One hundred and twenty-five patients were enrolled (mean age 64.8 ± 16.0 years, 65.6% male). Five hundred and fifteen BIVA measurements were performed. The mean CFB recorded at the end of the observational period was 2.7 ± 4.1 L, while the maximum hydration of lean body mass estimated by BIVA was 83.67 ± 6.39%. Severe hyperhydration measured by BIVA was the only variable found to be significantly associated with ICU mortality (OR 22.91; 95% CI 2.38-220.07; p < 0.01). CONCLUSIONS: The hydration status measured by BIVA seems to predict mortality risk in ICU patients better than the conventional method of fluid balance recording. Moreover, it appears to be safe, easy to use and adequate for bedside evaluation. Randomized clinical trials with an adequate sample size are needed to validate the diagnostic properties of BIVA in the goal-directed fluid management of critically ill patients in ICU.


Assuntos
Cuidados Críticos/métodos , Impedância Elétrica , Hidratação/métodos , Resultado do Tratamento , Idoso , Idoso de 80 Anos ou mais , Cuidados Críticos/normas , Estado Terminal/mortalidade , Estado Terminal/terapia , Feminino , Hidratação/normas , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Risco , Equilíbrio Hidroeletrolítico/fisiologia
16.
Clin Nephrol ; 86(7): 18-26, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27285313

RESUMO

BACKGROUND: Renal function reserve (RFR) describes the capacity of the kidney to increase glomerular filtration rate (GFR) in response to physiological or pathological stimuli. The scope of our study was to evaluate the optimal level of stimulation using different doses of protein load (PL) for a standard renal stress test (RST). METHODS: 18 young healthy individuals were given sessions of PL with 1 and 2 g/kg body weight. Endogenous creatinine clearance was calculated. Baseline GFR (bGFR) and stress GFR (sGFR) (post-PL) were obtained; RFR is the difference between stress and baseline GFR. A p-value < 0.05 was considered statistically significant. RESULTS: Mean bGFR was 107.97 ± 12.33 mL/min/1.73m2. sGFR with 1 and 2 g PL were significantly higher than bGFR in all subjects. The sGFR after 2 g PL (141.75 ± 19.90 mL/min/1.73m2) was not statistically different from the sGFR after 1 g PL (142.37 ± 22.35 mL/min/1.73m2). sGFR and therefore RFR were independent from the value of bGFR. CONCLUSIONS: We found no difference between 1 and 2 g/kg body weight PL to elicit sGFR. RST may be useful to predict susceptibility and risk of developing acute kidney injury and/or progression to chronic kidney disease. RST uncovers the possible loss of renal functional mass when this condition is not manifested clinically. Further studies are needed to set this hypothesis.


Assuntos
Creatinina , Taxa de Filtração Glomerular , Rim/fisiologia , Proteínas/administração & dosagem , Adulto , Creatinina/sangue , Creatinina/urina , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
17.
Blood Purif ; 41(1-3): 171-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26764970

RESUMO

BACKGROUND: Dialysate fluid connection to the membrane in continuous dialysis may affect solute clearance. Although circuit connections are routinely made counter-current to blood flow in intermittent dialysis, no study has assessed the effect of this dialysate fluid flow direction on removal of small solutes creatinine and urea during treatment using continuous veno-venous haemodialysis (CVVHD). AIMS: To assess if dialysate flow direction during CVVHD affects small solute removal. METHODS: This ethics-approved study recruited a convenience sample of 26 adult ICU patients requiring continuous dialysis to assess urea and creatinine removal for con-current vs. counter-current dialysate flow direction. The circuit was adjusted from continuous veno-venous haemodiafiltration to CVVHD 20 min prior to sampling with no fluid removal. Blood (b) and spent dialysate fluid (f) were taken in both concurrent and counter-current fluid flow at 1 (T1) and 4 (T4) hours with a new treatment. Blood flow was 200 ml/min. Dialysate flow 33 ml/min. Removal of urea and creatinine was expressed as the diafiltrate/plasma concentration ratio: Uf/b and Cf/b respectively. Data lacking normal distribution are presented as median with 25th and 75th interquartile ranges (IQR), otherwise as mean with SD and assessed with the independent t test for paired data. p < 0.5 was considered significant. RESULTS: Fifteen male patients were included with a median (IQR) age of 67 years (52-75), and APACHE x0399;x0399; score 17 (14-19) with all patients meeting RIFLE criteria 'F'. At both times, the counter-current dialysate flow was associated with higher mean (SD) diafiltrate/plasma concentration ratios: T1 0.87 (0.16) vs. 0.77 (0.10), p = 0.006; T2 0.96 (0.16) vs. 0.76 (0.09), p < 0.001 for creatinine and T1 0.98 (0.09) vs. 0.81 (0.09), p < 0.001; T2 0.99 (0.07) vs. 0.82 (0.08), p < 0.001 for urea. CONCLUSION: Counter-current dialysate flow during CVVHD for ICU patients is associated with an approximately 20% increase in removal of small solutes creatinine and urea. Video Journal Club 'Cappuccino with Claudio Ronco' at http://www.karger.com/?doi=441270.


Assuntos
Injúria Renal Aguda/terapia , Soluções para Diálise/uso terapêutico , Hemodiafiltração/métodos , Insuficiência Renal Crônica/terapia , Injúria Renal Aguda/sangue , Injúria Renal Aguda/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Creatinina/sangue , Feminino , Hemodiafiltração/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/patologia , Resultado do Tratamento , Ureia/sangue
18.
Lancet ; 383(9931): 1807-13, 2014 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-24856026

RESUMO

BACKGROUND: Peritoneal dialysis is the renal replacement therapy of choice for acute kidney injury in neonates, but in some cases is not feasible or effective. Continuous renal replacement therapy (CRRT) machines are used off label in infants smaller than 15 kg and are not designed specifically for small infants. We aimed to design and create a CRRT machine specifically for neonates and small infants. METHODS: We prospectively planned a 5-year project to conceive, design, and create a miniaturised Cardio-Renal Pediatric Dialysis Emergency Machine (CARPEDIEM), specifically for neonates and small infants. We created the new device and assessed it with in-vitro laboratory tests, completed its development to meet regulatory requirements, and obtained a licence for human use. Once approved, we used the machine to treat a critically ill neonate FINDINGS: The main characteristics of CARPEDIEM are the low priming volume of the circuit (less than 30 mL), miniaturised roller pumps, and accurate ultrafiltration control via calibrated scales with a precision of 1 g. In-vitro tests confirmed that both hardware and software met the specifications. We treated a 2·9 kg neonate with haemorrhagic shock, multiple organ dysfunction, and severe fluid overload for more than 400 h with the CARPEDIEM, using continuous venovenous haemofiltration, single-pass albumin dialysis, blood exchange, and plasma exchange. The patient's 65% fluid overload, raised creatinine and bilirubin concentrations, and severe acidosis were all managed safely and effectively. Despite the severity of the illness, organ function was restored and the neonate survived and was discharged from hospital with only mild renal insufficiency that did not require renal replacement therapy. INTERPRETATION: The CARPEDIEM CRRT machine can be used to provide various treatment modalities and support for multiple organ dysfunction in neonates and small infants. The CARPEDIEM could reduce the range of indications for peritoneal dialysis, widen the range of indications for CRRT, make the use of CRRT less traumatic, and expand its use as supportive therapy even when complete renal replacement therapy is not indicated. FUNDING: Associazione Amici del Rene di Vicenza.


Assuntos
Injúria Renal Aguda/terapia , Rins Artificiais , Terapia de Substituição Renal/instrumentação , Injúria Renal Aguda/sangue , Bilirrubina/sangue , Biomarcadores/sangue , Creatinina/sangue , Desenho de Equipamento , Humanos , Lactente , Recém-Nascido , Terapia Intensiva Neonatal/métodos , Teste de Materiais/métodos , Insuficiência de Múltiplos Órgãos/sangue , Insuficiência de Múltiplos Órgãos/terapia , Estudos Prospectivos
19.
Blood Purif ; 40(2): 180-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26305014

RESUMO

BACKGROUND/AIM: Bisphenol A (BPA) is used in the production of many plastics, which are used to build biomaterials that sometimes are in direct contact with blood. It is believed that the release of BPA into bloodstream may give rise to cytotoxic events for blood components. The aim of the present study was to perform an in vitro investigation of the observable cytotoxic effect of BPA, at increasing concentrations, on the monocyte cell line. METHODS: We incubated in vitro monocyte cells (U937) for 24 h in cell line medium samples (RPMI 1640) at different concentrations of BPA. We then generated curves to evaluate viability, necrosis and apoptosis of monocytes against increasing concentrations of BPA. RESULTS: The percentage values of concentrations of BPA corresponding to 50% of the viability and necrosis of the monocytes were 1.39 and 1.48 ng/ml, respectively. Based on our observations, we reported an increasing cytotoxic effect for higher concentrations. The apoptotic effect reached the maximum value at BPA concentration of 1.5 ng/ml; at still higher concentrations, we observed a predominantly necrotic cell death. CONCLUSION: Viability, necrosis and apoptosis of monocytes are strongly and positively correlated with BPA concentration. A direct contact of such compound with biological components of blood may lead to high levels of cytotoxicity, and require us to evaluate additional factors while judging the bio-incompatibility of BPA.


Assuntos
Compostos Benzidrílicos/toxicidade , Disruptores Endócrinos/toxicidade , Poluentes Ambientais/toxicidade , Monócitos/efeitos dos fármacos , Necrose/induzido quimicamente , Fenóis/toxicidade , Apoptose/efeitos dos fármacos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Fragmentação do DNA/efeitos dos fármacos , Humanos , Concentração Inibidora 50 , Monócitos/patologia , Necrose/patologia
20.
BMC Nephrol ; 15: 26, 2014 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-24490775

RESUMO

BACKGROUND: While fluid overload (FO) and alterations in the autonomic nervous system (ANS) such as hypersympathetic activity, are known risk factors for cardiovascular morbidity and mortality in patients on chronic hemodialysis (HD), their relationship has not been thoroughly studied. METHODS: In this observational study involving 69 patients on chronic HD, FO was assessed by whole body bioimpedance measurements before the midweek HD session and ANS activity reflected by Heart Rate Variability (HRV) was measured using 24-hour Holter electrocardiogram recordings starting before the same HD treatment. In total, 13 different HRV indices were analyzed, comprising a mixture of time domain, frequency domain and complexity parameters. A correlation analysis was performed between the HRV indices and hydration status indices. Successively, patients were retrospectively assigned to a high FO (H, FO > 2.5 L) or low FO (L, FO ≤ 2.5 L) group and these were further compared also after stratification by diabetes mellitus. Finally, a small number of patients without diabetes with significant and persistent FO were followed up for 3 months post-study to investigate how normalization of fluid status affects HRV. RESULTS: SDANN, VLF, LZC and HF% parameters significantly correlate with FO (correlation coefficients were respectively r = -0.40, r = -0.37, r = -0.28 and r = 0.26, p-value < 0.05). Furthermore, LF% and LF/HF were inversely correlated with hydration status (correlation coefficients were respectively r = -0.31 and r = -0.33, p-value < 0.05). These results indicate an association between FO and reduced HRV, higher parasympathetic activation and reduced sympathetic response to the HD session. Indeed, group H tended to have lower values of SDANN, VLF and LZC, and higher values of HF% than patients in the L group. Finally, there was a trend towards lower LF% measured during the last 30 minutes of HD for the H group versus the L group. Reduction in FO achieved over 3 months by implementation of a strict fluid management plan resulted in an increase of HRV. CONCLUSIONS: Our results suggest that depressed HRV is associated with fluid overload and that normalization of hydration status is accompanied by improved HRV.


Assuntos
Hidratação/métodos , Frequência Cardíaca , Diálise Renal , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/terapia , Desequilíbrio Hidroeletrolítico/fisiopatologia , Desequilíbrio Hidroeletrolítico/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/complicações , Resultado do Tratamento , Desequilíbrio Hidroeletrolítico/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA