Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Radiologe ; 61(1): 13-20, 2021 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-33052442

RESUMO

CLINICAL ISSUE: Image-guided radiotherapy (IGRT) using X­rays and cone-beam computed tomography (CT) has fostered precision radiotherapy. However, inter- and intrafractional variations of target volume position and organs at risk still limit target volume dose and sparing of radiosensitive organs at risk. METHODOLOGICAL INNOVATIONS: Hybrid machines directly combining linear accelerators and magnetic resonance (MR) imaging allow for live imaging during radiotherapy. PERFORMANCE: Besides highly improved soft tissue contrast, MR-linacs enable online, on-table adaptive radiotherapy. Thus, adaptation of the treatment plan to the anatomy of the day, dose escalation and superior sparing of organs at risk become possible. ACHIEVEMENTS: This article summarizes the underlying intention for the development of MR-guided radiotherapy, technical innovations and challenges as well as the current state-of-the-art. Potential clinical benefits and future developments are discussed. PRACTICAL RECOMMENDATIONS: Increasing availability of MR imaging at linear accelerators calls for the ability to review and interpret MR images. Therefore, close collaborations of diagnostic radiologists and radiation oncologists are mandatory to foster this fascinating technique.


Assuntos
Radioterapia (Especialidade) , Radioterapia Guiada por Imagem , Humanos , Imageamento por Ressonância Magnética , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
2.
Z Med Phys ; 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38184375

RESUMO

INTRODUCTION: Patient specific quality assurance (QA) in MR-Linacs can be performed with MR-compatible ion chamber arrays. However, the presence of a static magnetic field can alter the angular response of such arrays substantially. This works investigates the suitability of two ion chamber arrays, an air-filled and a liquid-filled array, for patient specific QA at a 0.35 T MR-Linac using a static phantom. METHODS: In order to study the angular response, the two arrays were placed in a static, solid phantom and irradiated with 9.96 × 9.96 cm2 fields every 10° beam angle at a 0.35 T MR-Linac. Measurements were compared to the TPS calculated dose in terms of gamma passing rate and relative dose to the central chamber. 20 patient specific quality assurance plans were measured using the liquid-filled array. RESULTS: The air-filled array showed asymmetric angular response changes of central chamber dose of up to 18% and down to local 3 mm / 3% gamma rates of 20%, while only minor differences within 3% (excluding parallel irradiation and beams through the couch edges) were found for the liquid-filled ion chamber array without rotating the phantom. Patient plan QA using the liquid-filled array yielded a median local 3 mm / 3% 3D gamma passing rate of 99.8% (range 96.9%-100%). CONCLUSION: A liquid-filled ionization chamber array in combination with a static phantom can be used for efficient patient specific plan QA in a single measurement set-up in a 0.35 T MR-Linac, while the air-filled ion chamber array phantom shows large angular response changes and has its limitations regarding patient specific QA measurements.

3.
Clin Transl Radiat Oncol ; 46: 100771, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38586081

RESUMO

Background: Due to superior image quality and daily adaptive planning, MR-guided stereotactic body radiation therapy (MRgSBRT) has the potential to further widen the therapeutic window in radiotherapy of localized prostate cancer. This study reports on acute toxicity rates and patient-reported outcomes after MR-guided adaptive ultrahypofractionated radiotherapy for localized prostate cancer within the prospective, multicenter phase II SMILE trial. Materials and methods: A total of 69 patients with localized prostate cancer underwent MRgSBRT with daily online plan adaptation. Inclusion criteria comprised a tumor stage ≤ T3a, serum PSA value ≤ 20 ng/ml, ISUP Grade group ≤ 4. A dose of 37.5 Gy was prescribed to the PTV in five fractions on alternating days with an optional simultaneous boost of 40 Gy to the dominant intraprostatic lesion defined by multiparametric MRI. Acute genitourinary (GU-) and gastrointestinal (GI-) toxicity, as defined by CTCAE v. 5.0 and RTOG as well as patient-reported outcomes according to EORTC QLQ-C30 and -PR25 scores were analyzed at completion of radiotherapy, 6 and 12 weeks after radiotherapy and compared to baseline symptoms. Results: There were no toxicity-related treatment discontinuations. At the 12-week follow-up visit, no grade 3 + toxicities were reported according to CTCAE. Up until the 12-week visit, in total 16 patients (23 %) experienced a grade 2 GU or GI toxicity. Toxicity rates peaked at the end of radiation therapy and subsided within the 12-week follow-up period. At the 12-week follow-up visit, no residual grade 2 GU toxicities were reported and 1 patient (1 %) had residual grade 2 enteritic symptoms. With exception to a significant improvement in the emotional functioning score following MRgSBRT, no clinically meaningful changes in the global health status nor in relevant subscores were reported. Conclusion: Daily online-adaptive MRgSBRT for localized prostate cancer resulted in an excellent overall toxicity profile without any major negative impact on quality of life.

4.
Biomed Phys Eng Express ; 9(6)2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37591227

RESUMO

The combination of magnetic resonance (MR) imaging and linear accelerators (linacs) into MR-Linacs enables continuous MR imaging and advanced gated treatments of patients. Previously, a dose-rate transient (∼8% reduced dose rate during the initial 0.5 s of each beam) was identified for a Viewray MRIdian MR-Linac (Klavsenet al2022Radiation Measurement106759). Here, the dose-rate transient is studied in more detail at four linacs of the same type at different hospitals. The implications of dose-rate transients were examined for gated treatments. The dose-rate transients were investigated using dose-per pulse measurements with organic plastic scintillators in three experiments: (i) A gated treatment with the scintillator placed in a moving target in a dynamic phantom, (ii) a gated treatment with the same dynamic conditions but with the scintillator placed in a stationary target, and (iii) measurements in a water-equivalent material to examine beam quality deviations at a dose-per-pulse basis. Gated treatments (i) compared with non-gated treatments with a static target in the same setup showed a broadening of accumulated dose profiles due to motion (dose smearing). The linac with the largest dose-rate transient had a reduced accumulated dose of up to (3.1 ± 0.65) % in the center of the PTV due to the combined dose smearing and dose-rate transient effect. Dose-rate transients were found to vary between different machines. Two MR-Linacs showed initial dose-rate transients that could not be identified from conventional linearity tests. The source of the transients includes an initial change in photon fluence rate and an initial change in x-ray beam quality. For gated treatments, this caused a reduction of more than 1% dose delivered at the central part of the beam for the studied, cyclic-motion treatment plan. Quality assurance of this effect should be considered when gated treatment with the Viewray MRIdian is implemented clinically.


Assuntos
Fótons , Plásticos , Humanos , Frequência Cardíaca , Movimento (Física) , Imagens de Fantasmas
5.
Radiat Oncol ; 17(1): 75, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35428327

RESUMO

BACKGROUND: Normofractionated radiation regimes for definitive prostate cancer treatment usually extend over 7-8 weeks. Recently, moderate hypofractionation with doses per fraction between 2.2 and 4 Gy has been shown to be safe and feasible with oncologic non-inferiority compared to normofractionation. Radiobiologic considerations lead to the assumption that prostate cancer might benefit in particular from hypofractionation in terms of tumor control and toxicity. First data related to ultrahypofractionation demonstrate that the overall treatment time can be reduced to 5-7 fractions with single doses > 6 Gy safely, even with simultaneous focal boosting of macroscopic tumor(s). With MR-guided linear accelerators (MR-linacs) entering clinical routine, invasive fiducial implantations become unnecessary. The aim of the multicentric SMILE study is to evaluate the use of MRI-guided stereotactic radiotherapy for localized prostate cancer in 5 fractions regarding safety and feasibility. METHODS: The study is designed as a prospective, one-armed, two-stage, multi-center phase-II-trial with 68 patients planned. Low- and intermediate-risk localized prostate cancer patients will be eligible for the study as well as early high-risk patients (cT3a and/or Gleason Score ≤ 8 and/or PSA ≤ 20 ng/ml) according to d'Amico. All patients will receive definitive MRI-guided stereotactic radiation therapy with a total dose of 37.5 Gy in 5 fractions (single dose 7.5 Gy) on alternating days. A focal simultaneous integrated boost to MRI-defined tumor(s) up to 40 Gy can optionally be applied. The primary composite endpoint includes the assessment of urogenital or gastrointestinal toxicity ≥ grade 2 or treatment-related discontinuation of therapy. The use of MRI-guided radiotherapy enables online plan adaptation and intrafractional gating to ensure optimal target volume coverage and protection of organs at risk. DISCUSSION: With moderate hypofractionation being the standard in definitive radiation therapy for localized prostate cancer at many institutions, ultrahypofractionation could be the next step towards reducing treatment time without compromising oncologic outcomes and toxicities. MRI-guided radiotherapy could qualify as an advantageous tool as no invasive procedures have to precede in therapeutic workflows. Furthermore, MRI guidance combined with gating and plan adaptation might be essential in order to increase treatment effectivity and reduce toxicity at the same time.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Hipofracionamento da Dose de Radiação , Radiocirurgia/métodos
6.
Radiat Oncol ; 17(1): 59, 2022 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-35346270

RESUMO

BACKGROUND: Stereotactic body radiotherapy (SBRT) is an established local treatment method for patients with hepatic oligometastasis or oligoprogression. Liver metastases often occur in close proximity to radiosensitive organs at risk (OARs). This limits the possibility to apply sufficiently high doses needed for optimal local control. Online MR-guided radiotherapy (oMRgRT) is expected to hold potential to improve hepatic SBRT by offering superior soft-tissue contrast for enhanced target identification as well as the benefit of gating and daily real-time adaptive treatment. The MAESTRO trial therefore aims to assess the potential advantages of adaptive, gated MR-guided SBRT compared to conventional SBRT at a standard linac using an ITV (internal target volume) approach. METHODS: This trial is conducted as a prospective, randomized, three-armed phase II study in 82 patients with hepatic metastases (solid malignant tumor, 1-3 hepatic metastases confirmed by magnetic resonance imaging (MRI), maximum diameter of each metastasis ≤ 5 cm (in case of 3 metastases: sum of diameters ≤ 12 cm), age ≥ 18 years, Karnofsky Performance Score ≥ 60%). If a biologically effective dose (BED) ≥ 100 Gy (α/ß = 10 Gy) is feasible based on ITV-based planning, patients will be randomized to either MRgRT or ITV-based SBRT. If a lesion cannot be treated with a BED ≥ 100 Gy, the patient will be treated with MRgRT at the highest possible dose. Primary endpoint is the non-inferiority of MRgRT at the MRIdian Linac® system compared to ITV-based SBRT regarding hepatobiliary and gastrointestinal toxicity CTCAE III or higher. Secondary outcomes investigated are local, locoregional (intrahepatic) and distant tumor control, progression-free survival, overall survival, possible increase of BED using MRgRT if the BED is limited with ITV-based SBRT, treatment-related toxicity, quality of life, dosimetric parameters of radiotherapy plans as well as morphological and functional changes in MRI. Potential prognostic biomarkers will also be evaluated. DISCUSSION: MRgRT is known to be both highly cost- and labor-intensive. The MAESTRO trial aims to provide randomized, higher-level evidence for the dosimetric and possible consecutive clinical benefit of MR-guided, on-table adaptive and gated SBRT for dose escalation in critically located hepatic metastases adjacent to radiosensitive OARs. TRIAL REGISTRATION: The study has been prospectively registered on August 30th, 2021: Clinicaltrials.gov, "Magnetic Resonance-guided Adaptive Stereotactic Body Radiotherapy for Hepatic Metastases (MAESTRO)", NCT05027711.


Assuntos
Neoplasias Hepáticas , Radiocirurgia , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética , Estudos Prospectivos , Qualidade de Vida , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem
7.
Phys Med Biol ; 66(24)2021 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-34845991

RESUMO

Objective.In MR-guided radiotherapy (MRgRT) for prostate cancer treatments inter-fractional anatomy changes such as bladder and rectum fillings may be corrected by an online adaption of the treatment plan. To clinically implement such complex treatment procedures, however, specific end-to-end tests are required that are able to validate the overall accuracy of all treatment steps from pre-treatment imaging to dose delivery.Approach.In this study, an end-to-end test of a fractionated and online adapted MRgRT prostate irradiation was performed using the so-called ADAM-PETer phantom. The phantom was adapted to perform 3D polymer gel (PG) dosimetry in the prostate and rectum. Furthermore, thermoluminescence detectors (TLDs) were placed at the center and on the surface of the prostate for additional dose measurements as well as for an external dose renormalization of the PG. For the end-to-end test, a total of five online adapted irradiations were applied in sequence with different bladder and rectum fillings, respectively.Main results.A good agreement of measured and planned dose was found represented by highγ-index passing rates (3%/3mmcriterion) of the PG evaluation of98.9%in the prostate and93.7%in the rectum. TLDs used for PG renormalization at the center of the prostate showed a deviation of-2.3%.Significance.The presented end-to-end test, which allows for 3D dose verification in the prostate and rectum, demonstrates the feasibility and accuracy of fractionated and online-adapted prostate irradiations in presence of inter-fractional anatomy changes. Such tests are of high clinical importance for the commissioning of new image-guided treatment procedures such as online adaptive MRgRT.


Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pelve/diagnóstico por imagem , Pelve/efeitos da radiação , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA