1.
Anesth Analg ; 128(3): 414-423, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-29944523

RESUMO

BACKGROUND: Rotational thromboelastometry (ROTEM) can provide clinical information in 10-20 minutes for guiding administration of fibrinogen, platelets, and fresh frozen plasma products. While ROTEM testing is well established for cardiac and other surgeries, it is less characterized for use in postpartum hemorrhage (PPH) patients. We wanted to determine if the earlier-measured ROTEM parameters (α-angle and amplitude at 10 minutes [A10]) could replace the later parameters (amplitude at 20 minutes and maximum amplitude [maximum clot firmness {MCF}]) in all patient groups studied. We also correlated the A10 and α-angle of the EXTEM and FIBTEM tests to the fibrinogen levels and platelet counts in these patients. METHODS: We retrospectively analyzed 100 sets of EXTEM and FIBTEM results ordered on patients undergoing operations for PPH, patients in intensive care units (ICU), and those undergoing cardiothoracic surgery (cardiothoracic operating room [C/T OR]). We determined if the correlations among the various parameters were similar among the PPH, ICU, and C/T OR patients. RESULTS: As expected, the EXTEM A10 (A10EX) and FIBTEM A10 (A10FIB) correlated highly to the EXTEM MCF and FIBTEM MCF in all patient groups. The A10EX parameter correlated significantly to both fibrinogen and platelet levels, and the A10FIB correlated to the fibrinogen levels. The difference between the A10EX and the A10FIB (PLTEM) is related to platelet activity, and we found that the PLTEM and platelet count correlated highly for all 100 PPH patients (r = 0.80), C/T OR patients (r = 0.70), and ICU patients (r = 0.66), despite 4 high platelet counts with relatively low PLTEM values in the ICU group. The earlier-reported parameter EXTEM α angle (α-EX) is an excellent indicator of the A10EX, with an α-EX ≥65° (ie, normal) giving a >96% probability that the A10EX was ≥44 mm, and an α-EX value below 65 mm giving an 86% probability that the A10EX was <44 mm. CONCLUSIONS: The correlations among the ROTEM parameters for the PPH comparisons were equivalent to the C/T OR patients studied, and the A10EX and A10FIB could replace the MCF results in all patient groups. Also, the α-EX was an early indicator of the A10EX and had good correlations to the A10FIB and the fibrinogen in all patient groups. Finally, in a separate group of 62 comparisons, the FIBTEM α angle showed promise as an early indicator of the A10FIB and the fibrinogen levels.


Assuntos
Coagulação Sanguínea/fisiologia , Cuidados Críticos/métodos , Fibrinogênio/metabolismo , Ativação Plaquetária/fisiologia , Hemorragia Pós-Parto/sangue , Tromboelastografia/métodos , Feminino , Humanos , Cuidados Pós-Operatórios/métodos , Hemorragia Pós-Parto/diagnóstico , Distribuição Aleatória , Estudos Retrospectivos
2.
J Appl Lab Med ; 6(5): 1228-1236, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34080626

RESUMO

BACKGROUND: Two previous reports from the same group concluded that the analytical reliability of Instrumentation Laboratory GEM4000 analyzers (GEM4K) deteriorated during a 24-hour period, based on results between samples from the same patient but collected at different times. Our routine blood gas Between-Laboratory Survey is done every 2 weeks using a freshly pooled heparinized blood sample taken to each analyzer location to verify comparability among our GEM4K and Radiometer ABL90 (Rad90) blood gas analyzers. Because another report found a few very large differences in glucose results between the GEM4K and central laboratory analyzers, we reviewed the glucose results on plasma from our Chemistry Between-Laboratory Surveys that includes comparisons between our central laboratory analyzers (Beckman DxC800; DxC800) and our GEM4K and Rad90 blood gas analyzers. METHOD: Using data from our Blood Gas and Chemistry Surveys over a 55-week period, we calculated the mean, standard deviation (SD), and concentration intervals of the 27 sets of results by the GEM4K or Rad90 analyzers. Agreement in plasma glucose between DxC800 and blood gas analyzers was evaluated by the limits of agreement and intraclass correlation coefficient analysis. RESULTS: For each analyte, the Rad90 had lower average SD than the GEM4K for the 55-week period, although both brands of analyzers showed acceptable performance. For plasma glucose results on our Chemistry Survey, the GEM4K results agreed more closely with the DxC800 results than the Rad90 results. CONCLUSIONS: Based on both our Blood Gas and Chemistry Surveys, we conclude that both brands of analyzers performed within analytically and clinically acceptable limits throughout the year, with no evidence for the type of errors reported previously.


Assuntos
Gasometria , Laboratórios , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes , Estudos Retrospectivos