Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Transplant ; 28(1): e14626, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37853942

RESUMO

BACKGROUND: Heart transplantation (HTx) is an established therapeutic option for children with end-stage heart failure. Comprehensive pediatric nationwide HTx program was introduced in 2014 in the Czech Republic. The aim of this study was to evaluate its mid-term characteristics and outcomes and to compare them with international data. METHODS: Retrospective observational study, including all patients who underwent HTx from June 2014 till December 2022. Data from the institutional database were used for descriptive statistics and survival analyses. RESULTS: A total of 30 HTx were performed in 29 patients with congenital heart disease (CHD, N = 15, single ventricular physiology in 10 patients) and cardiomyopathy (CMP, N = 14). Ten patients were bridged to HTx by durable left ventricular assist devices (LVADs) for a mean duration of 104 (SD 89) days. There was one early and one late death during median follow-up of 3.3 (IQR 1.3-6.1) years. Survival probability at 5 years after HTx was 93%. Two patients underwent re-transplantation (one of them in an adult center). Significant rejection-free survival at 1, 3, and 6 years after HTx was 76%, 63%, and 63%, respectively. CONCLUSIONS: The introduced pediatric HTx program reflects the complexity of the treated population, with half of the patients having complex CHD and one-third being bridged to HTx by LVADs. Mid-term results are comparable to worldwide data. The data confirm the possibility of establishing a successful nationwide pediatric HTx program in a relatively small population country with well-developed pediatric cardiovascular care and other transplantation programs.


Assuntos
Cardiomiopatias , Cardiopatias Congênitas , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adulto , Humanos , Criança , Insuficiência Cardíaca/cirurgia , República Tcheca , Estudos Retrospectivos , Resultado do Tratamento
2.
Cell Tissue Bank ; 25(1): 87-98, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37085639

RESUMO

Reconstruction of right ventricular outflow tract in patients with congenital heart disease in various age groups remains a controversial issue. Currently, a little is known about the fate of secondary and subsequent conduit. The aim of the study was to determine risk factors of conduit failure, evaluate long-term conduit survival, find out which type of conduit should be preferred in case of reoperations. We performed a retrospective analysis of a total of 249 records of valved conduit secondary and subsequent replacement in right ventricular outflow tract in 197 patients. Median follow-up was 5.7 years. The study endpoints were defined as conduit explants; balloon dilatation of the graft (excluding balloon dilatation of left/right pulmonary artery), transcatheter pulmonary valve implantation; heart transplantation or death of the patient. There were total of 21 deaths (11% mortality) among 197 patients during the follow-up, 2 patients underwent heart transplant, in 23 implanted conduits pulmonary angioplasty or/including transcatheter pulmonary valve implantation was afterwards performed due to graft failure, conduit had to be explanted in 46 cases. After 28 years follow-up, freedom from graft failure after 5 years was 77%, 48% after 10 years and 21% after 15 years. Reoperative right ventricular outflow tract reconstruction demonstrates good mid-term and acceptable long-term outcomes regardless of the type of conduit implanted. Worse long-term graft survival of secondary and further conduits is associated with younger age of the recipient at implantation, small size of the conduit, younger age of donor and male donor in case of allograft implantation.


Assuntos
Cardiopatias Congênitas , Humanos , Masculino , Lactente , Seguimentos , Estudos Retrospectivos , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/cirurgia , Reoperação , Fatores de Risco , Resultado do Tratamento
3.
Cell Tissue Bank ; 24(4): 779-788, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37227562

RESUMO

This study aimed to evaluate the efficacy of cryopreserved amniotic membrane (AM) grafts in chronic wound healing, including the mean percentage of wound closure per one AM application, and to determine whether the healing efficiency differs between AM grafts obtained from different placentas. A retrospective study analyzing inter-placental differences in healing capacity and mean wound closure after the application of 96 AM grafts prepared from nine placentas. Only the placentas from which the AM grafts were applied to patients suffering from long-lasting non-healing wounds successfully healed by AM treatment were included. The data from the rapidly progressing wound-closure phase (p-phase) were analyzed. The mean efficiency for each placenta, expressed as an average of wound area reduction (%) seven days after the AM application (baseline, 100%), was calculated from at least 10 applications. No statistical difference between the nine placentas' efficiency was found in the progressive phase of wound healing. The 7-day average wound reduction in particular placentas varied from 5.70 to 20.99% (median from 1.07 to 17.75) of the baseline. The mean percentage of wound surface reduction of all analyzed defects one week after the application of cryopreserved AM graft was 12.17 ± 20.12% (average ± SD). No significant difference in healing capacity was observed between the nine placentas. The data suggest that if there are intra- and inter-placental differences in AM sheets' healing efficacy, they are overridden by the actual health status of the subject or even the status of its individual wounds.


Assuntos
Âmnio , Placenta , Humanos , Feminino , Gravidez , Estudos Retrospectivos , Âmnio/transplante , Cicatrização , Criopreservação
4.
Am J Transplant ; 22(8): 2094-2098, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35000286

RESUMO

Patients with pulmonary hypertension and end-stage lung disease are fraught with high mortality while on a waiting list for lung transplant. With sometimes rapid deterioration they may require veno-arterial extracorporeal membrane oxygenation (VA-ECMO) as an immediate life-saving technique, which is a time-limited solution. The technique of pulmonary artery to left atrium (PA-LA) shunt fitted with an oxygenator enables bridging the patient to transplant for a longer time period. This low-resistance paracorporeal pumpless lung assist device allows for de-adaptation of the right ventricle back to lower afterload before the lung transplantation is carried out. The PA-LA shunt with an oxygenator also conveys a risk of multiple complications with reported median of 10-26 days until transplant. We report a case of pulmonary capillary hemangiomatosis in a 35-year-old female who had to wait for donor lungs during the pandemic of SARS-CoV-2 for 143 days on PA-LA shunt with oxygenator following 51 days on VA-ECMO. The extremely long course associated with multiple complications including three cerebral embolisms, episodes of sepsis and ingrowth of the return cannula into the left ventricular wall gives insight into the limits of this bridging technique.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Hipertensão Pulmonar , Adulto , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Átrios do Coração , Humanos , Hipertensão Pulmonar/etiologia , Pulmão , Pandemias , Artéria Pulmonar , SARS-CoV-2
5.
Ann Vasc Surg ; 85: 156-166, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35304297

RESUMO

BACKGROUND: Critical limb ischemia (CLI) is considered the most severe pattern of peripheral artery disease. CLI is associated with high rates of morbidity and mortality with high risk of limb amputation. In the absence of appropriate autologous grafts, unsuitability of prosthetic bypasses, and endovascular methods, fresh cold-stored venous allografts is an option. Endovascular interventional methods are essential methods for maintaining primary and secondary patency. METHODS: A single-centre retrospective analysis of 82 surgical revascularizations using allogeneic vascular grafts and rescue endovascular techniques restoring and maintaining the patency of these allogeneic revascularizations in the period between July 2005 and July 2021. RESULTS: We have performed 82 allogeneic revascularizations in 75 patients (52 reconstructions in men/63.4%/, 30 reconstructions in women/36.6%/). The median age of patients was 68 years (49 min, 87 max). We subsequently had to intervene a total of 26 bypasses. We intervened in 30 acute occluded allogeneic bypass grafts and 9 failing stenotic bypass grafts. We performed 52 angiographies. The success rate of rescue endovascular procedures in primary allogeneic reconstruction with distal anastomosis to the popliteal artery is statistically significant (P < 0.02) compared to procedures with distal anastomosis to the tibial and pedal bed. The cumulative patency (primary at time) of allogeneic reconstructions in our group was 89% after 1 month, 51.9% after 12 months, 24.2% after 3 years, 9.8% after 5 years. Limb salvage was 72.6% in 1 year, 53% in 3 years, 36.5% in 5 years, respectively. CONCLUSIONS: Cold-stored venous allografts may be used for performing below-the-knee revascularization for CLI with acceptable results, despite the poor long-term patency. Rescue endovascular techniques are an essential method for restoring or maintaining the patency of these reconstructions. These techniques have a high success rate and no other alternative.


Assuntos
Procedimentos Endovasculares , Doença Arterial Periférica , Idoso , Aloenxertos/cirurgia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/cirurgia , Salvamento de Membro , Masculino , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
6.
Int Wound J ; 19(5): 1243-1252, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34791774

RESUMO

We evaluated the effect of the application of cryo-preserved amniotic membrane on the healing of 26 non-healing wounds (18 patients) with varying aetiologies and baseline sizes (average of 15.4 cm2 ), which had resisted the standard of care treatment for 6 to 456 weeks (average 88.8 weeks). Based on their average general responses to the application of cryo-preserved AM, we could differentiate three wound groups. The first healed group was characterised by complete healing (100% wound closure, maximum treatment period 38 weeks) and represented 62% of treated wounds. The wound area reduction of at least 50% was reached for all wounds in this group within the first 10 weeks of treatment. Exactly 19% of the studied wounds responded partially to the treatment (partially healed group), reaching less than 25% of closure in the first 10 weeks and 90% at maximum for extended treatment period (up to 78 weeks). The remaining 19% of treated wounds did not show any reaction to the AM application (unhealed defects). The three groups have different profiles of wound area reduction, which can be used as a guideline in predicting the healing prognosis of non-healing wounds treated with a cryo-preserved amniotic membrane.


Assuntos
Âmnio , Cicatrização , Humanos , Cicatrização/fisiologia
7.
Cell Tissue Bank ; 22(2): 161-184, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32583302

RESUMO

Despite the wide choice of commercial heart valve prostheses, cryopreserved semilunar allograft heart valves (C-AHV) are required, and successfully transplanted in selected groups of patients. The expiration limit (EL) criteria have not been defined yet. Most Tissue Establishments (TE) use the EL of 5 years. From physiological, functional, and surgical point of view, the morphology and mechanical properties of aortic and pulmonary roots represent basic features limiting the EL of C-AHV. The aim of this work was to review methods of AHV tissue structural analysis and mechanical testing from the perspective of suitability for EL validation studies. Microscopic structure analysis of great arterial wall and semilunar leaflets tissue should clearly demonstrate cells as well as the extracellular matrix components by highly reproducible and specific histological staining procedures. Quantitative morphometry using stereological grids has proved to be effective, as the exact statistics was feasible. From mechanical testing methods, tensile test was the most suitable. Young's moduli of elasticity, ultimate stress and strain were shown to represent most important AHV tissue mechanical characteristics, suitable for exact statistical analysis. C-AHV are prepared by many different protocols, so as each TE has to work out own EL for C-AHV.


Assuntos
Valva Aórtica , Criopreservação , Aloenxertos , Aorta , Valva Aórtica/cirurgia , Módulo de Elasticidade , Humanos
8.
Eur J Pediatr ; 179(11): 1739-1750, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32424742

RESUMO

Atypical haemolytic uraemic syndrome is an ultra-rare, life-threatening disease. Causative variants in genes that encode complement factors can be identified in 40-70% of cases. We performed genetic analysis of 21 Czech children with atypical haemolytic uraemic syndrome. Genetic or acquired predisposition to the disease was identified in the majority of our patients: CFHR1 and CFHR3 deletions in 14/21 (67%; 13 of them were positive for anti-complement factor H antibodies), variants in complement genes or DGKE in 13/21 (62%). Multiple genetic findings were identified in eight patients (38%). The incidence of atypical haemolytic uraemic syndrome in the Czech paediatric population was estimated to be 0.092 (CI 0.053-0.131) cases per million inhabitants and 0.92 (CI 0.53-1.32) cases per 100,000 births for the entire reporting period. Ten patients were initially treated with plasma exchange and eight with eculizumab or with a combination of eculizumab and plasma exchange. At the last follow-up, 20 patients were alive and one patient had end-stage renal disease.Conclusion: The incidence of atypical haemolytic uraemic syndrome in the Czech paediatric population corresponds to the reported incidence in Europe. We detected the unusually high rate of CFHR1/CFHR3 deletions associated with anti-complement factor H antibodies in Czech paediatric patients. Treatment by eculizumab led to superior outcomes and prevention of the disease relapses compared with plasma exchange therapy. Our results may help to understand the polygenic nature of atypical haemolytic uraemic syndrome as a disease that results from a combination of various risk factors. What is Known: • Atypical haemolytic uraemic syndrome (aHUS) is considered a polygenic and multifactorial disease. Genetic predisposition to aHUS is identified in 40-70% of children. • Anti-complement factor H antibodies are usually found in 6-25% of affected children. What is New: • Potentially causative genetic or acquired factors were confirmed in the majority of patients. The prevailing finding was the unusually high rate of CFHR1/CFHR3 deletions associated with anti-complement factor H antibodies (62% of patients). • The incidence of aHUS in Czech children is 0.092 (CI 0.053-0.131) cases per million inhabitants and 0.92 (CI 0.53-1.32) cases per 100,000 births for the entire reporting period.


Assuntos
Síndrome Hemolítico-Urêmica Atípica , Síndrome Hemolítico-Urêmica Atípica/epidemiologia , Síndrome Hemolítico-Urêmica Atípica/genética , Síndrome Hemolítico-Urêmica Atípica/terapia , Criança , República Tcheca/epidemiologia , Europa (Continente) , Humanos , Troca Plasmática , Fatores de Risco
9.
Cell Tissue Bank ; 20(2): 221-241, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30903411

RESUMO

The aortic and pulmonary allograft heart valves (AHV) are used in the cardiac surgery for replacing the impaired semilunar valves. They are harvested from donor hearts and cryostored in tissue banks. The expiration period was set to 5 years arbitrarily. We hypothesized that their mechanical and structural properties do not deteriorate after this period. A total of 64 human AHV (31 aortic and 33 pulmonary) of different length of cryopreservation (fresh, 0-5, 5-10, over 10 years) were sampled to different tissue strips (artery, leaflet, ventriculo-arterial junction) and tested by tensile test with loading velocity 10 mm/min until tissue rupture. Neighbouring regions of tissue were processed histologically and evaluated for elastin and collagen area fraction. The results were evaluated statistically. In aortic AHV, the physical deformation response of wall samples to stress did not changed significantly neither during the process of cryopreservation nor during the first 10 years of storage. In pulmonary AHV, the ultimate strain dropped after 5 years of cryopreservation indicating that pulmonary artery was significantly less deformable at the time of rupture. On the other hand, the ultimate stress was equal during the first 10 years of cryostorage. The changes in collagen and elastin amount in the tissue samples were not associated with mechanical impairment. Neither elasticity, stiffness and solidity nor morphology of aortic and pulmonary AHV did not change reasonably with cryopreservation and in the first 10 years of cryostorage. This evidence suggests that the expiration period might be extended in the future.


Assuntos
Valva Aórtica/transplante , Criopreservação/métodos , Valva Pulmonar/transplante , Bancos de Tecidos , Adulto , Colágeno/análise , Elastina/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transplante Homólogo
10.
Cell Tissue Bank ; 19(4): 581-589, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30062597

RESUMO

Two decontamination solutions, commercially produced BASE•128 and laboratory decontamination solution (LDS), with analogous content of antibiotic and antimycotic agents, were compared in their antimicrobial efficiency and stability (pH and osmolarity). Both solutions were compared immediately after thawing aliquots frozen for 1, 3 or 6 months. Agar well diffusion method was used to test their antimicrobial efficiency against five human pathogens: Staphylococcus aureus, Pseudomonas aeruginosa, Proteus mirabilis, Escherichia coli and Enterococcus faecalis. The difference in the inhibition of growth between the two decontamination solutions was mostly not statistically significant, with few exceptions. The most pronounced difference between the LDS and BASE•128 was observed in their decontamination efficacy against E. coli and E. faecalis, where the LDS showed to be more efficient than BASE•128. The osmolarity value of LDS decreased with cold-storage, the osmolarity values of the BASE•128 could not be measured as they were below the range of the osmometer. Slight changes were found in pH of the less stable LDS solution, whose pH increased from initial value 7.36 ± 0.07 to 7.72 ± 0.19 after 6 m-storage. We verified that BASE•128 and LDS are similarly efficient in elimination of possible placental bacterial contaminants and may be used for decontamination of various tissues.


Assuntos
Anti-Infecciosos/farmacologia , Descontaminação , Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Concentração de Íons de Hidrogênio , Testes de Sensibilidade Microbiana , Concentração Osmolar , Soluções
12.
Cell Tissue Bank ; 18(3): 413-423, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28677080

RESUMO

Human amniotic membrane (HAM) is used as an allograft in regenerative medicine or as a source of pluripotent cells for stem cell research. Various decontamination protocols and solutions are used to sterilize HAM before its application, but little is known about the toxicity of disinfectants on HAM cells. In this study, we tested two decontamination solutions, commercial (BASE·128) and laboratory decontamination solution (LDS), with an analogous content of antimycotic/antibiotics for their cytotoxic effect on HAM epithelial (EC) and mesenchymal stromal cells (MSC). HAM was processed in a standard way, placed on nitrocellulose scaffold, and decontaminated, following three protocols: (1) 6 h, 37 °C; (2) 24 h, room temperature; (3) 24 h, 4 °C. The viability of EC was assessed via trypan blue staining. The apoptotic cells were detected using terminal deoxynucleotidyl transferase dUTP nick end labelling (TUNEL). The mean % (±SD) of dead EC (%DEC) from six fresh placentas was 12.9 ± 18.1. Decontamination increased %DEC compared to culture medium. Decontamination with BASE·128 for 6 h, 37 °C led to the highest EC viability (81.7%). Treatment with LDS at 24 h, 4 °C resulted in the lowest EC viability (55.9%) in the set. MSC were more affected by apoptosis than EC. Although the BASE·128 expresses lower toxicity compared to LDS, we present LDS as an alternative decontamination solution with a satisfactory preservation of cell viability. The basic formula of LDS will be optimised by enrichment with nutrient components, such as glucose or vitamins, to improve cell viability.


Assuntos
Âmnio/citologia , Descontaminação/métodos , Células-Tronco Mesenquimais/citologia , Apoptose , Contagem de Células , Sobrevivência Celular , Células Cultivadas , Criopreservação/métodos , Feminino , Humanos , Marcação In Situ das Extremidades Cortadas , Gravidez
13.
Bioengineering (Basel) ; 10(8)2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37627785

RESUMO

To compare the therapeutic efficacy of cryopreserved amniotic membrane (AM) grafts and standard of care (SOC) in treating nonhealing wounds (NHW) through a prospective multicenter clinical trial, 42 patients (76% polymorbid) with 54 nonhealing wounds of various etiologies (mainly venous) and an average baseline size of 20 cm2 were included. All patients were treated for at least 6 weeks in the center before they were involved in the study. In the SOC group, 29 patients (36 wounds) were treated. If the wound healed less than 20% of the baseline size after 6 weeks, the patient was transferred to the AM group (35 patients, 43 wounds). Weekly visits included an assessment of the patient's condition, photo documentation, wound debridement, and dressing. Quality of life and the pain degree were subjectively reported by patients. After SOC, 7 wounds were healed completely, 1 defect partially, and 28 defects remained unhealed. AM application led to the complete closure of 24 wounds, partial healing occurred in 10, and 9 remained unhealed. The degree of pain and the quality of life improved significantly in all patients after AM application. This study demonstrates the effectiveness of cryopreserved AM grafts in the healing of NHW of polymorbid patients and associated pain reduction.

14.
Bioengineering (Basel) ; 10(6)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37370671

RESUMO

The aim of this study was to compare concentrations of endogenous N-acylethanolamine (NAE) lipid mediators-palmitoylethanolamide (PEA), oleoylethanolamide (OEA), and anandamide (AEA)-in fresh, decontaminated, cryopreserved, and freeze-dried amniotic membrane (AM) allografts, thereby determining whether AM's analgesic and anti-inflammatory efficiency related to NAEs persists during storage. The concentrations of NAEs were measured using ultra-high-performance liquid chromatography-tandem mass spectrometry. Indirect fluorescent immunohistochemistry was used to detect the PEA PPAR-α receptor. The concentrations of PEA, OEA, and AEA were significantly higher after decontamination. A significant decrease was found in cryopreserved AM compared to decontaminated tissue for PEA but not for OEA and AEA. However, significantly higher values for all NAEs were detected in cryopreserved samples compared to fresh tissue before decontamination. The freeze-dried AM had similar values to decontaminated AM with no statistically significant difference. The nuclear staining of the PPAR-α receptor was clearly visible in all specimens. The stability of NAEs in AM after cryopreservation was demonstrated under tissue bank storage conditions. However, a significant decrease, but still higher concentration of PEA compared to fresh not decontaminated tissue, was found in cryopreserved, but not freeze-dried, AM. Results indicate that NAEs persist during storage in levels sufficient for the analgesic and anti-inflammatory effects. This means that cryopreserved AM allografts released for transplant purposes before the expected expiration (usually 3-5 years) will still show a strong analgesic effect. The same situation was confirmed for AM lyophilized after one year of storage. This work thus contributed to the clarification of the analgesic effect of NAEs in AM allografts.

15.
Nephrol Dial Transplant ; 27(2): 820-4, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21652544

RESUMO

BACKGROUND: We hypothesized that supplementing a higher mass of renal parenchyma from adult donors, and their younger age, would improve graft function in paediatric recipients. METHODS: We calculated estimated glomerular filtration rate (eGFR; Schwartz formula) and absolute glomerular filtration rate (absGFR) in 57 renal-grafted children (1995-2007) aged 3.1-17.9 years, weighing 12.9-85.0 kg, on discharge from the hospital after transplantation (TPL), 1 year after TPL and at the last follow-up (1.5-11.7 years after TPL). We correlated their eGFR with the individual ratio between the donor and the recipient body weight at the time of TPL (donor/recipient body weight ratio; D/R BWR), and we evaluated the effect of the donor and the actual recipient body weight on the eGFR and absGFR. RESULTS: The D/R BWR varied from 0.65 to 5.23. We found a significant positive correlation between D/R BWR and eGFR at discharge from the hospital (P < 0.001), 1-year post-TPL (P < 0.001) and at the last follow-up (P < 0.05). Using multiple linear regression analyses, we found that both eGFR and absGFR values were much more determined by the actual recipient weight than by the donor weight (27/6% and 43/4% at discharge, by 24/4% and 57/0% 1 year after TPL, and 0/0% and 20/0% at the end of the follow-up). A tendency for lower eGFR with increasing age of donors was apparent at discharge and 1 year after TPL, but it reached statistical significance only at the last follow-up (r = 0.4254, P < 0.01). CONCLUSION: In paediatric renal transplants, the value of D/R BWR directly correlated with eGFR in the early and late posttransplant periods. However, this correlation was mainly influenced by the recipient weight, while the donor weight played only a minor or negligible role.


Assuntos
Peso Corporal , Falência Renal Crônica/cirurgia , Transplante de Rim/métodos , Doadores Vivos , Tamanho do Órgão , Adolescente , Adulto , Fatores Etários , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Seguimentos , Taxa de Filtração Glomerular , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Falência Renal Crônica/diagnóstico , Testes de Função Renal , Transplante de Rim/efeitos adversos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo , Doadores de Tecidos
16.
Braz J Cardiovasc Surg ; 37(5)2022 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-35072402

RESUMO

INTRODUCTION: Cryopreserved allograft heart valves (CAHV) show longer event-free survival compared to other types of protheses. However, all patients develop early and/or late allograft failure. Negative predictors are clinical, and there is a lack of evidence whether they correspond with the microscopic structure of CAHV. We assessed histopathological signs of structural degeneration, degree of cellular preservation, and presence of antigen-presenting cells (APC) in CAHV and correlated the changes with donor clinical characteristics, cryopreservation times, and CAHV types and diameters. METHODS: Fifty-seven CAHV (48 pulmonary, nine aortic) used for transplantation between November/2017 and May/2019 were included. Donor variables were age, gender, blood group, height, weight, and body surface area (BSA). Types and diameters of CAHV, cold ischemia time, period from decontamination to cryopreservation, and cryopreservation time were recorded. During surgery, arterial wall (n=56) and valvar cusp (n=20) samples were obtained from the CAHV and subjected to microscopy. Microscopic structure was assessed using basic staining methods and immunohistochemistry (IHC). RESULTS: Most of the samples showed signs of degeneration, usually of mild degree, and markedly reduced cellular preservation, more pronounced in aortic CAHV, correlating with arterial APC counts in both basic staining and IHC. There was also a correlation between the degree of degeneration of arterial samples and age, height, weight, and BSA of the donors. These findings were independent of preservation times. CONCLUSION: CAHV show markedly reduced cellular preservation negatively correlating with the numbers of APC. More preserved CAHV may be therefore prone to stronger immune rejection.


Assuntos
Criopreservação , Doadores de Tecidos , Humanos , Transplante Homólogo , Valvas Cardíacas/transplante , Aloenxertos , Valva Aórtica/cirurgia , Valva Aórtica/patologia
17.
Front Pediatr ; 9: 752878, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34805047

RESUMO

Monogenic nephrotic syndrome (NS) is associated with a resistance to initial glucocorticoid therapy and causative variants, which may be found in several genes influencing podocyte stability and kidney development. The TTC21B gene, which encodes the retrograde intraflagellar transport protein IFT139, is found mostly in association with ciliopathies in humans. The role of this protein in podocyte cytoskeleton stability was confirmed later and the mutated TTC21B also may be associated with proteinuric diseases, such as nephrotic syndrome. Our patient manifested as an infant with brachydactyly, nephrotic-range proteinuria, and renal tubular acidosis, and a kidney biopsy revealed focal segmental glomerulosclerosis (FSGS). Multiple phalangeal cone-shaped epiphyses of the hand were seen on X-ray. Next-generation sequencing revealed the well-described p.Pro209Leu heterozygous variant and a novel heterozygous p.Cys14Arg variant in the TTC21B gene. Our finding confirmed that the causative variants in the TTC21B gene may contribute to a spectrum of clinical features, such as glomerular proteinuric disease with tubulointerstitial involvement and skeletal abnormalities.

18.
J Cardiothorac Surg ; 14(1): 94, 2019 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-31113456

RESUMO

BACKGROUND: Sparing Aortic Valve procedure requires to reproduction of the geometry of the physiologic anatomy of the aortic root. Thus, the materials adopted may make a difference. CARDIOROOT is a one-piece collagen-coated woven vascular graft with pseudo-sinuses, which was designed for use in the treatment of aortic root disease. We report the results of a prospective, multicenter, observational post-market surveillance study evaluating the safety and performance of the CARDIOROOT in patients requiring aortic root surgery. METHODS: Patients with aortic root disease suitable for treatment with a vascular graft with pseudo-sinuses CARDIOROOT graft were eligible for participation. The enrolled patients were assessed intraoperatively, post-operatively, at discharge and at 1-year. Sites assessed complications at each visit, and recorded any reported adverse events. The study endpoint was mortality and complications through 1-year post-procedure. RESULTS: Fifty-two patients were enrolled from 6 European centers. All procedures were technically successful. Operative mortality was 1.9%: one patient suffered hemorrhagic shock unrelated to the graft 1 day following surgery. At 1-year follow-up the survival rate was 96.2%, with a late death due to pneumonia 5 months post-procedure. Eleven serious adverse events occurred in 7 patients, which included cardiac complications (pericardial effusion, myocardial infarction and ventricular arrhythmia), infection (pericardial infection, deep sternal infection and superficial sternal infection), vascular disorders, including hemorrhagic shock and pleural effusion requiring drainage. Nine of the 11 events were deemed procedure-related by the local investigator, and all were deemed unrelated to the device. There were no reports of graft-related adverse events, infection, occlusion or graft failure. CONCLUSIONS: The results of this 1-year follow-up study showed that the CARDIOROOT vascular graft is safe and effective for the treatment of aneurysmal aortic root in immediate and mid-term follow-up. However, longer term follow-up is needed before conclusions can be made on the long-term safety and effectiveness. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01609270. Registered 31 May 2012.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Adulto , Idoso , Aneurisma da Aorta Torácica/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Taxa de Sobrevida , Adulto Jovem
19.
Adv Clin Exp Med ; 28(4): 529-534, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30684317

RESUMO

BACKGROUND: Vascular allotransplantations are performed worldwide in selected patients suffering from vascular prosthesis infection or critical limb ischemia. Either fresh or cryopreserved vascular allograft may be used. OBJECTIVES: In various points, we address several aspects (allograft procurement, cryopreservation and transplantation technique) of the program of vascular allotransplantations in the Czech Republic. MATERIAL AND METHODS: Vascular grafts retrieval has been done within multiorgan harvests using no-touch technique. Very short time of cold ischemia is achieved due to close cooperation with Tissue Establishment where the following processing of cryopreservation is performed. Meeting all necessary quality criteria is a prerequisity for releasing grafts for clinical application. Standardized thawing protocol and surgical handling aims to minimize microfractures before implantation. RESULTS: Based on experimental and clinical work, the first validation of cryopreserved arterial and venous grafts for clinical use was performed between 2011 and 2013 in the Czech Republic. The developement of storage of vascular tissue in banks was stimulated in 2000-2010 by the issue of EU directives and national harmonized norms, aimed at assurance of high quality and safety of cells and tissues used for transplantations in humans. CONCLUSIONS: There are several crucial moments affecting final quality, including graft retrieval within a multiorgan harvest, short ischemic time, cryopreservation and thawing technique used. The recommended surgical handling during implantation may also affect results and graft-related complications.


Assuntos
Prótese Vascular , Vasos Sanguíneos/transplante , Criopreservação , Obtenção de Tecidos e Órgãos , Transplante Homólogo/métodos , Enxerto Vascular/métodos , Aloenxertos , Vasos Sanguíneos/fisiologia , Criopreservação/métodos , República Tcheca , Humanos , Bancos de Tecidos , Obtenção de Tecidos e Órgãos/estatística & dados numéricos
20.
Adv Clin Exp Med ; 27(8): 1033-1036, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29975466

RESUMO

BACKGROUND: The aim of our experimental work was to assess the impact and morphological changes that arise during different thawing protocols on human aortic valve (AV) leaflets resected from cryopreserved aortic root allografts (CARAs). OBJECTIVES: Two thawing protocols were tested: 1. CARAs were thawed at a room temperature (23°C); 2. CARAs were placed directly into a water bath at a temperature of 37°C. After all the samples were thawed, non-coronary AV leaflets were sampled from each specimen and fixed in a 4% formaldehyde solution before they were sent for morphological analysis. MATERIAL AND METHODS: All the samples were washed in distilled water for 5 min and dehydrated in a graded ethanol series (70%, 85%, 95%, and 100%) for 5 min at each level. The tissue samples were then immersed in 100% hexamethyldisilazane (HMDS) for 10 min, and then air-dried in an exhaust hood at room temperature. Processed samples were mounted on stainless steel stubs and coated with gold. Histological analysis was performed with the use of an electron microscope on a scanning mode operating at 25 kV - BS 301. RESULTS: Thawing protocol 1 (room temperature at 23°C): 6 (100%) samples showed loss of the endothelial covering of the basal membrane with no damage to the basal lamina. Thawing protocol 2 (water bath at 37°C): 5 (83%) samples showed loss of the endothelial covering of the basal membrane with no damage to the basal lamina. One (17%) sample showed loss of the endothelial covering the basal membrane with significant damage to the basal membrane. CONCLUSIONS: Based on our experimental work, we can clearly conclude that cryopreserved AV leaflet allografts show identical structural changes at different rates of thawing.


Assuntos
Valva Aórtica/transplante , Criopreservação/métodos , Transplante Homólogo/métodos , Aloenxertos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA