Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Sensors (Basel) ; 22(23)2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36501850

RESUMO

Heart Rate Variability (HRV) and Blood Pressure Variability (BPV) are widely employed tools for characterizing the complex behavior of cardiovascular dynamics. Usually, HRV and BPV analyses are carried out through short-term (ST) measurements, which exploit ~five-minute-long recordings. Recent research efforts are focused on reducing the time series length, assessing whether and to what extent Ultra-Short-Term (UST) analysis is capable of extracting information about cardiovascular variability from very short recordings. In this work, we compare ST and UST measures computed on electrocardiographic R-R intervals and systolic arterial pressure time series obtained at rest and during both postural and mental stress. Standard time-domain indices are computed, together with entropy-based measures able to assess the regularity and complexity of cardiovascular dynamics, on time series lasting down to 60 samples, employing either a faster linear parametric estimator or a more reliable but time-consuming model-free method based on nearest neighbor estimates. Our results are evidence that shorter time series down to 120 samples still exhibit an acceptable agreement with the ST reference and can also be exploited to discriminate between stress and rest. Moreover, despite neglecting nonlinearities inherent to short-term cardiovascular dynamics, the faster linear estimator is still capable of detecting differences among the conditions, thus resulting in its suitability to be implemented on wearable devices.


Assuntos
Pressão Arterial , Eletrocardiografia , Frequência Cardíaca/fisiologia , Pressão Sanguínea , Entropia
2.
Entropy (Basel) ; 24(5)2022 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-35626609

RESUMO

This work investigates the temporal statistical structure of time series of electric field (EF) intensity recorded with the aim of exploring the dynamical patterns associated with periods with different human activity in urban areas. The analyzed time series were obtained from a sensor of the EMF RATEL monitoring system installed in the campus area of the University of Novi Sad, Serbia. The sensor performs wideband cumulative EF intensity monitoring of all active commercial EF sources, thus including those linked to human utilization of wireless communication systems. Monitoring was performed continuously during the years 2019 and 2020, allowing us to investigate the effects on the patterns of EF intensity of varying conditions of human mobility, including regular teaching and exam activity within the campus, as well as limitations to mobility related to the COVID-19 pandemic. Time series analysis was performed using both simple statistics (mean and variance) and combining the information-theoretic measure of information storage (IS) with the method of surrogate data to quantify the regularity of EF dynamic patterns and detect the presence of nonlinear dynamics. Moreover, to assess the possible coexistence of dynamic behaviors across multiple temporal scales, IS analysis was performed over consecutive observation windows lasting one day, week, month, and year, respectively coarse grained at time scales of 6 min, 30 min, 2 h, and 1 day. Our results document that the EF intensity patterns of variability are modulated by the movement of people at daily, weekly, and monthly scales, and are blunted during periods of restricted mobility related to the COVID-19 pandemic. Mobility restrictions also affected significantly the regularity of the EF intensity time series, resulting in lower values of IS observed simultaneously with a loss of nonlinear dynamics. Thus, our analysis can be useful to investigate changes in the global patterns of human mobility both during pandemics or other types of events, and from this perspective may serve to implement strategies for safety assessment and for optimizing the design of networks of EF sensors.

3.
Entropy (Basel) ; 21(5)2019 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-33267240

RESUMO

Heart rate variability (HRV; variability of the RR interval of the electrocardiogram) results from the activity of several coexisting control mechanisms, which involve the influence of respiration (RESP) and systolic blood pressure (SBP) oscillations operating across multiple temporal scales and changing in different physiological states. In this study, multiscale information decomposition is used to dissect the physiological mechanisms related to the genesis of HRV in 78 young volunteers monitored at rest and during postural and mental stress evoked by head-up tilt (HUT) and mental arithmetics (MA). After representing RR, RESP and SBP at different time scales through a recently proposed method based on multivariate state space models, the joint information transfer T RESP , SBP → RR is decomposed into unique, redundant and synergistic components, describing the strength of baroreflex modulation independent of respiration ( U SBP → RR ), nonbaroreflex ( U RESP → RR ) and baroreflex-mediated ( R RESP , SBP → RR ) respiratory influences, and simultaneous presence of baroreflex and nonbaroreflex respiratory influences ( S RESP , SBP → RR ), respectively. We find that fast (short time scale) HRV oscillations-respiratory sinus arrhythmia-originate from the coexistence of baroreflex and nonbaroreflex (central) mechanisms at rest, with a stronger baroreflex involvement during HUT. Focusing on slower HRV oscillations, the baroreflex origin is dominant and MA leads to its higher involvement. Respiration influences independent on baroreflex are present at long time scales, and are enhanced during HUT.

4.
Nano Lett ; 17(1): 150-155, 2017 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-27959556

RESUMO

Phase change materials (PCMs) are highly attractive for nonvolatile electrical and all-optical memory applications because of unique features such as ultrafast and reversible phase transitions, long-term endurance, and high scalability to nanoscale dimensions. Understanding their transient characteristics upon phase transition in both the electrical and the optical domains is essential for using PCMs in future multifunctional optoelectronic circuits. Here, we use a PCM nanowire embedded into a nanophotonic circuit to study switching dynamics in mixed-mode operation. Evanescent coupling between light traveling along waveguides and a phase-change nanowire enables reversible phase transition between amorphous and crystalline states. We perform time-resolved measurements of the transient change in both the optical transmission and resistance of the nanowire and show reversible switching operations in both the optical and the electrical domains. Our results pave the way toward on-chip multifunctional optoelectronic integrated devices, waveguide integrated memories, and hybrid processing applications.

5.
Opt Express ; 22(7): 7544-9, 2014 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-24718128

RESUMO

We report on backward second-harmonic generation using ps laser pulses in congruent lithium niobate with 3.2 µm periodic poling. Three resonant peaks were measured between 1530 and 1730 nm, corresponding to 16th, 17th and 18th quasi-phase-matching orders in the backward configuration, with a conversion efficiency of 4.75 x 10(-5%)/W for the 16th order. We could also discriminate the contributions from inverted domains randomized in duty-cycle.

6.
Biosensors (Basel) ; 14(4)2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38667198

RESUMO

Wearable health devices (WHDs) are rapidly gaining ground in the biomedical field due to their ability to monitor the individual physiological state in everyday life scenarios, while providing a comfortable wear experience. This study introduces a novel wearable biomedical device capable of synchronously acquiring electrocardiographic (ECG), photoplethysmographic (PPG), galvanic skin response (GSR) and motion signals. The device has been specifically designed to be worn on a finger, enabling the acquisition of all biosignals directly on the fingertips, offering the significant advantage of being very comfortable and easy to be employed by the users. The simultaneous acquisition of different biosignals allows the extraction of important physiological indices, such as heart rate (HR) and its variability (HRV), pulse arrival time (PAT), GSR level, blood oxygenation level (SpO2), and respiratory rate, as well as motion detection, enabling the assessment of physiological states, together with the detection of potential physical and mental stress conditions. Preliminary measurements have been conducted on healthy subjects using a measurement protocol consisting of resting states (i.e., SUPINE and SIT) alternated with physiological stress conditions (i.e., STAND and WALK). Statistical analyses have been carried out among the distributions of the physiological indices extracted in time, frequency, and information domains, evaluated under different physiological conditions. The results of our analyses demonstrate the capability of the device to detect changes between rest and stress conditions, thereby encouraging its use for assessing individuals' physiological state. Furthermore, the possibility of performing synchronous acquisitions of PPG and ECG signals has allowed us to compare HRV and pulse rate variability (PRV) indices, so as to corroborate the reliability of PRV analysis under stationary physical conditions. Finally, the study confirms the already known limitations of wearable devices during physical activities, suggesting the use of algorithms for motion artifact correction.


Assuntos
Eletrocardiografia , Dedos , Resposta Galvânica da Pele , Frequência Cardíaca , Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Humanos , Monitorização Fisiológica/instrumentação , Processamento de Sinais Assistido por Computador , Masculino , Adulto , Feminino
7.
Opt Lett ; 38(2): 178-80, 2013 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-23454954

RESUMO

Frequency conversion by means of Kerr nonlinearity is one of the most common and exploited nonlinear optical processes in the UV, visible, IR, and mid-IR spectral regions. Here we show that wave mixing of an optical field and a terahertz wave can be achieved in diamond, resulting in the frequency conversion of the terahertz radiation either by sum- or difference-frequency generation. In the latter case, we show that this process is phase matched and most efficient in a counterpropagating geometry.

8.
Biosensors (Basel) ; 13(4)2023 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-37185535

RESUMO

The increasing interest in innovative solutions for health and physiological monitoring has recently fostered the development of smaller biomedical devices. These devices are capable of recording an increasingly large number of biosignals simultaneously, while maximizing the user's comfort. In this study, we have designed and realized a novel wearable multisensor ring-shaped probe that enables synchronous, real-time acquisition of photoplethysmographic (PPG) and galvanic skin response (GSR) signals. The device integrates both the PPG and GSR sensors onto a single probe that can be easily placed on the finger, thereby minimizing the device footprint and overall size. The system enables the extraction of various physiological indices, including heart rate (HR) and its variability, oxygen saturation (SpO2), and GSR levels, as well as their dynamic changes over time, to facilitate the detection of different physiological states, e.g., rest and stress. After a preliminary SpO2 calibration procedure, measurements have been carried out in laboratory on healthy subjects to demonstrate the feasibility of using our system to detect rapid changes in HR, skin conductance, and SpO2 across various physiological conditions (i.e., rest, sudden stress-like situation and breath holding). The early findings encourage the use of the device in daily-life conditions for real-time monitoring of different physiological states.


Assuntos
Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Humanos , Fotopletismografia/métodos , Monitorização Fisiológica , Frequência Cardíaca/fisiologia , Resposta Galvânica da Pele
9.
Comput Methods Programs Biomed ; 226: 107126, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36130416

RESUMO

BACKGROUND AND OBJECTIVE: Recently, various algorithms have been introduced using wrist-worn photoplethysmography (PPG) to provide high accuracy of instantaneous heart rate (HR) estimation, including during high-intensity exercise. Most studies focus on using acceleration and/or gyroscope signals for the motion artifact (MA) reference, which attenuates or cancels out noise from the MA-corrupted PPG signals. We aim to open and pave the path to find an appropriate MA reference selection for MA cancelation in PPG. METHODS: We investigated how the acceleration and gyroscope reference signals correlate with the MAs of the distorted PPG signals and derived both mathematically and experimentally an adaptive MA reference selection approach. We applied our algorithm to five state-of-the-art (SOTA) methods for the performance evaluation. In addition, we compared the four MA reference selection approaches, i.e. with acceleration signal only, with gyroscope signal only, with both signals, and using our proposed adaptive selection. RESULTS: When applied to 47 PPG recordings acquired during intensive physical exercise from two different datasets, our proposed adaptive MA reference selection method provided higher accuracy than the other MA selection approaches for all five SOTA methods. CONCLUSION: Our proposed adaptive MA reference selection approach can be used in other MA cancelation methods and reduces the HR estimation error. SIGNIFICANCE: We believe that this study helps researchers to address acceleration and gyroscope signals as accurate MA references, which eventually improves the overall performance for estimating HRs through the various algorithms developed by research groups.


Assuntos
Artefatos , Fotopletismografia , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador , Movimento (Física) , Frequência Cardíaca/fisiologia , Algoritmos , Aceleração
10.
Opt Express ; 19(25): 25780-5, 2011 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-22273970

RESUMO

We report on bulk and guided-wave second-harmonic generation via random Quasi-Phase-Matching in Lithium Tantalate. By acquiring the far-field profiles at several wavelengths, we extract statistical information on the distribution of the quadratic nonlinearity as well as its average period, both at the surface and in the bulk of the sample. By investigating the distribution in the two regions we demonstrate a non-invasive approach to the study of poling dynamics.


Assuntos
Desenho Assistido por Computador , Lítio/química , Lítio/efeitos da radiação , Modelos Teóricos , Óxidos/química , Óxidos/efeitos da radiação , Refratometria/instrumentação , Tantálio/química , Tantálio/efeitos da radiação , Simulação por Computador , Campos Eletromagnéticos , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Refratometria/métodos , Espalhamento de Radiação
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 290-293, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891293

RESUMO

Extensive efforts have been recently devoted to implement fast and reliable algorithms capable of assessing the physiological response of the organism to physiological stress. In this study, we propose the comparison between model-free and linear parametric methods as regards their ability to detect alterations in the dynamics and in the complexity of cardiovascular and respiratory variability evoked by postural and mental stress. Dynamic entropy (DE) and information storage (IS) measures were calculated on three physiological time-series, i.e. heart period, respiratory volume and systolic arterial pressure, on 61 healthy subjects monitored in resting conditions as well as during head-up tilt and while performing a mental arithmetic task. The results of the comparison suggest the feasibility of DE and IS measures computed from different physiological signals to discriminate among resting and stress states. If compared to the model-free algorithm, the faster linear method appears to be capable of detecting the same (or even more) statistically significant variations of DE or IS between resting and stress conditions, being thus in perspective more suitable for the integration within wearable devices. The computation of entropy indices extracted from multiple physiological signals acquired through wearables will allow a real-time stress assessment on people in daily-life situations.


Assuntos
Sistema Cardiovascular , Coração , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Gravidez , Estresse Fisiológico
12.
Front Netw Physiol ; 1: 765332, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-36925567

RESUMO

The amount of information exchanged per unit of time between two dynamic processes is an important concept for the analysis of complex systems. Theoretical formulations and data-efficient estimators have been recently introduced for this quantity, known as the mutual information rate (MIR), allowing its continuous-time computation for event-based data sets measured as realizations of coupled point processes. This work presents the implementation of MIR for point process applications in Network Physiology and cardiovascular variability, which typically feature short and noisy experimental time series. We assess the bias of MIR estimated for uncoupled point processes in the frame of surrogate data, and we compensate it by introducing a corrected MIR (cMIR) measure designed to return zero values when the two processes do not exchange information. The method is first tested extensively in synthetic point processes including a physiologically-based model of the heartbeat dynamics and the blood pressure propagation times, where we show the ability of cMIR to compensate the negative bias of MIR and return statistically significant values even for weakly coupled processes. The method is then assessed in real point-process data measured from healthy subjects during different physiological conditions, showing that cMIR between heartbeat and pressure propagation times increases significantly during postural stress, though not during mental stress. These results document that cMIR reflects physiological mechanisms of cardiovascular variability related to the joint neural autonomic modulation of heart rate and arterial compliance.

13.
Nanomaterials (Basel) ; 11(2)2021 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-33499063

RESUMO

We present an innovative implementation of the solid-state-biased coherent detection (SSBCD) technique, which we have recently introduced for the reconstruction of both amplitude and phase of ultra-broadband terahertz pulses. In our previous works, the SSBCD method has been operated via a heterodyne scheme, which involves demanding square-wave voltage amplifiers, phase-locked to the THz pulse train, as well as an electronic circuit for the demodulation of the readout signal. Here, we demonstrate that the SSBCD technique can be operated via a very simple homodyne scheme, exploiting plain static bias voltages. We show that the homodyne SSBCD signal turns into a bipolar transient when the static field overcomes the THz field strength, without the requirement of an additional demodulating circuit. Moreover, we introduce a differential configuration, which extends the applicability of the homodyne scheme to higher THz field strengths, also leading a two-fold improvement of the dynamic range compared to the heterodyne counterpart. Finally, we demonstrate that, by reversing the sign of the static voltage, it is possible to directly retrieve the absolute THz pulse polarity. The homodyne configuration makes the SSBCD technique of much easier access, leading to a vast range of field-resolved applications.

14.
Opt Express ; 18(25): 25967-72, 2010 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-21164943

RESUMO

We report on stable optical waveguides fabricated by soft-proton exchange in periodically-poled congruent lithium tantalate in the α-phase. The channel waveguides are characterized in the telecom wavelength range in terms of both linear properties and frequency doubling. The measurements yield a nonlinear coefficient of about 9.5 pm/V, demonstrating that the nonlinear optical properties of lithium tantalate are left nearly unaltered by the process.


Assuntos
Lítio/química , Óxidos/química , Refratometria/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Tantálio/química , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Dinâmica não Linear , Prótons
15.
Opt Lett ; 35(22): 3760-2, 2010 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21081988

RESUMO

We report on experimental evidence of parametric spatial solitons in a quadratic crystal with randomized periodic ferroelectric poling. Two-color self-focusing via quadratic cascading overcomes the diffractive nature of both fundamental and frequency-doubled beams.

16.
Front Neurosci ; 14: 602584, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33613173

RESUMO

In this work, we extend to the multivariate case the classical correlation analysis used in the field of network physiology to probe dynamic interactions between organ systems in the human body. To this end, we define different correlation-based measures of the multivariate interaction (MI) within and between the brain and body subnetworks of the human physiological network, represented, respectively, by the time series of δ, θ, α, and ß electroencephalographic (EEG) wave amplitudes, and of heart rate, respiration amplitude, and pulse arrival time (PAT) variability (η, ρ, π). MI is computed: (i) considering all variables in the two subnetworks to evaluate overall brain-body interactions; (ii) focusing on a single target variable and dissecting its global interaction with all other variables into contributions arising from the same subnetwork and from the other subnetwork; and (iii) considering two variables conditioned to all the others to infer the network topology. The framework is applied to the time series measured from the EEG, electrocardiographic (ECG), respiration, and blood volume pulse (BVP) signals recorded synchronously via wearable sensors in a group of healthy subjects monitored at rest and during mental arithmetic and sustained attention tasks. We find that the human physiological network is highly connected, with predominance of the links internal of each subnetwork (mainly η-ρ and δ-θ, θ-α, α-ß), but also statistically significant interactions between the two subnetworks (mainly η-ß and η-δ). MI values are often spatially heterogeneous across the scalp and are modulated by the physiological state, as indicated by the decrease of cardiorespiratory interactions during sustained attention and by the increase of brain-heart interactions and of brain-brain interactions at the frontal scalp regions during mental arithmetic. These findings illustrate the complex and multi-faceted structure of interactions manifested within and between different physiological systems and subsystems across different levels of mental stress.

17.
Front Neurosci ; 14: 204, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32218722

RESUMO

Autonomic nervous system (ANS) activity and imbalance between its sympathetic and parasympathetic components are important factors contributing to the initiation and progression of many cardiovascular disorders related to obesity. The results on respiratory sinus arrhythmia (RSA) magnitude changes as a parasympathetic index were not straightforward in previous studies on young obese subjects. Considering the potentially unbalanced ANS regulation with impaired parasympathetic control in obese patients, the aim of this study was to compare the relative contribution of baroreflex and non-baroreflex (central) mechanisms to the origin of RSA in obese vs. control subjects. To this end, we applied a recently proposed information-theoretic methodology - partial information decomposition (PID) - to the time series of heart rate variability (HRV, computed from RR intervals in the ECG), systolic blood pressure (SBP) variability, and respiration (RESP) pattern measured in 29 obese and 29 age- and gender-matched non-obese adolescents and young adults monitored in the resting supine position and during postural and cognitive stress evoked by head-up tilt and mental arithmetic. PID was used to quantify the so-called unique information transferred from RESP to HRV and from SBP to HRV, reflecting, respectively, non-baroreflex and RESP-unrelated baroreflex HRV mechanisms, and the redundant information transferred from (RESP, SBP) to HRV, reflecting RESP-related baroreflex RSA mechanisms. Our results suggest that obesity is associated: (i) with blunted involvement of non-baroreflex RSA mechanisms, documented by the lower unique information transferred from RESP to HRV at rest; and (ii) with a reduced response to postural stress (but not to mental stress), documented by the lack of changes in the unique information transferred from RESP and SBP to HRV in obese subjects moving from supine to upright, and by a decreased redundant information transfer in obese compared to controls in the upright position. These findings were observed in the presence of an unchanged RSA magnitude measured as the high frequency (HF) power of HRV, thus suggesting that the changes in ANS imbalance related to obesity in adolescents and young adults are subtle and can be revealed by dissecting RSA mechanisms into its components during various challenges.

18.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 4258-4261, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946809

RESUMO

We present a new method to quantify in the frequency domain the strength of directed interactions between linear stochastic processes. This issue is traditionally addressed by the directed coherence (DC), a popular causality measure derived from the spectral representation of vector autoregressive (AR) processes. Here, to overcome intrinsic limitations of the DC when it needs to be objectively quantified within specific frequency bands, we propose an approach based on spectral decomposition, which allows to isolate oscillatory components related to the pole representation of the vector AR process in the Z-domain. Relating the causal and non-causal power content of these components we obtain a new spectral causality measure, denoted as pole-specific spectral causality (PSSC). In this study, PSSC is compared with DC in the context of cardiovascular variability analysis, where evaluation of the spectral causality from arterial pressure to heart period variability is of interest to assess baroreflex modulation in the low frequency band (0.04-0-15 Hz). Using both a theoretical example in which baroreflex interactions are simulated, and real cardiovascular variability series measured from a group of healthy subjects during a postural challenge, we show that - compared with DC- PSSC leads to a frequency-specific evaluation of spectral causality which is more objective and more focused on the frequency band of interest.


Assuntos
Pressão Arterial , Barorreflexo , Frequência Cardíaca , Causalidade , Coração , Humanos , Processos Estocásticos
19.
Med Biol Eng Comput ; 57(6): 1247-1263, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30730027

RESUMO

Heart rate variability (HRV) analysis represents an important tool for the characterization of complex cardiovascular control. HRV indexes are usually calculated from electrocardiographic (ECG) recordings after measuring the time duration between consecutive R peaks, and this is considered the gold standard. An alternative method consists of assessing the pulse rate variability (PRV) from signals acquired through photoplethysmography, a technique also employed for the continuous noninvasive monitoring of blood pressure. In this work, we carry out a thorough analysis and comparison of short-term variability indexes computed from HRV time series obtained from the ECG and from PRV time series obtained from continuous blood pressure (CBP) signals, in order to evaluate the reliability of using CBP-based recordings in place of standard ECG tracks. The analysis has been carried out on short time series (300 beats) of HRV and PRV in 76 subjects studied in different conditions: resting in the supine position, postural stress during 45° head-up tilt, and mental stress during computation of arithmetic test. Nine different indexes have been taken into account, computed in the time domain (mean, variance, root mean square of the successive differences), frequency domain (low-to-high frequency power ratio LF/HF, HF spectral power, and central frequency), and information domain (entropy, conditional entropy, self entropy). Thorough validation has been performed using comparison of the HRV and PRV distributions, robust linear regression, and Bland-Altman plots. Results demonstrate the feasibility of extracting HRV indexes from CBP-based data, showing an overall relatively good agreement of time-, frequency-, and information-domain measures. The agreement decreased during postural and mental arithmetic stress, especially with regard to band-power ratio, conditional, and self-entropy. This finding suggests to use caution in adopting PRV as a surrogate of HRV during stress conditions.


Assuntos
Determinação da Pressão Arterial , Eletrocardiografia , Frequência Cardíaca/fisiologia , Adolescente , Feminino , Humanos , Masculino , Pulso Arterial , Análise de Regressão , Fatores de Tempo
20.
Physiol Meas ; 40(7): 074003, 2019 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-30952152

RESUMO

OBJECTIVE: In this work we explore the potential of combining standard time and frequency domain indexes with novel information measures, to characterize pre- and post-ictal heart rate variability (HRV) in epileptic children, with the aim of differentiating focal and generalized epilepsy regarding the autonomic control mechanisms. APPROACH: We analyze short-term HRV in 37 children suffering from generalized or focal epilepsy, monitored 10 s, 300 s, 600 s and 1800 s both before and after seizure episodes. Nine indexes are computed in time (mean, standard deviation of normal-to-normal intervals, root mean square of the successive differences (RMSSD)), frequency (low-to-high frequency power ratio LF/HF, normalized LF and HF power) and information (entropy, conditional entropy and self-entropy) domains. Focal and generalized epilepsy are compared through statistical analysis of the indexes and using linear discriminant analysis (LDA). MAIN RESULTS: In children with focal epilepsy, early post-ictal phase is characterized by significant tachycardia, depressed HRV, increased LF power and LF/HF, and decreased complexity, progressively recovered across time windows after the episodes. Children with generalized seizures instead show significant tachycardia, lower RMSSD, higher LF power and LF/HF ratio before the seizure. These different behaviors are exploited by LDA analysis to separate focal and generalized epilepsy up to an accuracy of 75%. Results suggest a shift of the sympatho-vagal balance towards sympathetic dominance and vagal withdrawal, noticeable just after the termination of seizure episodes and then reverted in focal epilepsy, and persistent during inter-ictal and pre-ictal periods in generalized epilepsy. SIGNIFICANCE: Our analysis helps in elucidating the pathophysiology of inter-ictal HRV autonomic control and the differential diagnosis of generalized and focal epilepsy. These findings may have clinical relevance since altered sympatho-vagal control can be related to a higher danger of morbidity and mortality, may reduce thresholds for life-threatening arrhythmias, and could be a biomarker of risk for sudden unexpected death in epilepsy.


Assuntos
Frequência Cardíaca , Convulsões/fisiopatologia , Sistema Nervoso Autônomo/fisiopatologia , Criança , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA