Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Health Serv Res ; 22(1): 1296, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36307809

RESUMO

BACKGROUND: In the current pandemic context, dental professionals have greater occupational risks due to their healthcare activity, placing their expectations on the vaccine as a means of protection and at the same time hoping that the immunization process will be safe, reliable and comfortable, giving them greater peace of mind when they return to work. Therefore, the aim of the present study was to develop and provide a preliminary validation of a scale to measure perception of the COVID-19 vaccination process in Peruvian dental professionals. METHODS: Cross-sectional study with instrumental design. The scale was self-administered virtually. It was distributed through social networks to 220 dental professionals from two universities in the Peruvian capital between June and August 2021. The Aiken V was used for content analysis, while descriptive statistics such as mean, variance, kurtosis and skewness were used for construct validation, in addition to Pearson's correlation matrix for analysis of the 18 items. Subsequently, a Parallel Analysis based on minimum rank factor analysis was performed. Finally, the reliability of the total scale and its dimensions was evaluated with Cronbach's alpha. RESULTS: The Aiken V coefficient values were favorable for all items. Parallel analysis indicated the existence of three dimensions. Principal component analysis with rotation suggested grouping eight items for the first dimension, six items for the second dimension and four items for the third dimension. These dimensions showed good reliability, as Cronbach's alpha was 0.87, (95% confidence interval [CI]: 0.84-0.90), 0.80 (95% CI: 0.75-0.84) and 0.82 (95% CI: 0.78-0.86), respectively. In addition, the overall reliability of the scale was 0.89 (95% CI: 0.86-0.91), being acceptable. CONCLUSIONS: The perception scale of the COVID-19 vaccination process in dental professionals proved preliminarily to be a valid and reliable scale that can be used for research purposes. However, it is recommended to extend its application and evaluate its metric properties in other health professionals.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Humanos , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários , Estudos Transversais , COVID-19/epidemiologia , COVID-19/prevenção & controle , Peru/epidemiologia , Percepção , Odontólogos , Vacinação
2.
BMC Oral Health ; 22(1): 258, 2022 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-35754035

RESUMO

BACKGROUND: It has been demonstrated that dental restorations with rough surfaces can have several disadvantages such as pigment retention or plaque accumulation, which can facilitate caries formation, color variation, loss of brightness, degradation of restoration, among others. The present study aimed to assess surface roughness in bulk fill and conventional nanohybrid resins with and without polishing, controlling the oxygen inhibited layer. METHODS: This in vitro and longitudinal experimental study consisted of 120 resin blocks of 6 mm diameter and 4 mm depth, divided into two groups: Bulk Fill (Tetric® N-Ceram Bulk-fill, Opus Bulk Fill APS, Filtek™ Bulk Fill) and conventional nanohybrid (Tetric® N-Ceram, Opallis EA2, Filtek™ Z250 XT). Each resin group was divided into two equal parts, placing glycerin only on one of them, in order to control the oxygen inhibited layer. Subsequently, the surface roughness was measured before and after the polishing procedure with Sof-Lex discs. The data were analyzed with the T-test for related measures, and for comparison between groups before and after polishing, the non-parametric Kruskal Wallis test with the Bonferroni post hoc was used, considering a significance level of p < 0.05. RESULTS: Before polishing, the resin composites with the lowest surface roughness were Opus Bulk Fill APS (0.383 ± 0.186 µm) and Opallis EA2 (0.430 ± 0. 177 µm) with and without oxygen inhibited layer control, respectively; while after polishing, those with the lowest surface roughness were Opus Bulk Fill APS (0.213 ± 0.214 µm) and Tetric N-Ceram (0.097 ± 0.099 µm), with and without oxygen inhibited layer control, respectively. Furthermore, before and after polishing, all resins significantly decreased their surface roughness (p < 0.05) except Opus Bulk Fill APS resin with oxygen inhibited layer control (p = 0.125). However, when comparing this decrease among all groups, no significant differences were observed (p < 0.05). CONCLUSION: The Opus Bulk Fill APS resin with oxygen inhibited layer control presented lower surface roughness both before and after polishing, being these values similar at both times. However, after polishing the other bulk fill and conventional nanohybrid resins with and without oxygen inhibited layer control, the surface roughness decreased significantly in all groups, being this decrease similar in all of them.


Assuntos
Polimento Dentário , Oxigênio , Resinas Compostas , Polimento Dentário/métodos , Humanos , Teste de Materiais , Propriedades de Superfície
3.
J Int Soc Prev Community Dent ; 14(1): 43-51, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559644

RESUMO

Aim: Long-term clinical success on indirect restorations is largely determined by bonding efficiency of the luting agent, with adhesion to dentin being the main challenge. Therefore, aim of this study was to assess the microtensile bond strength when using flowable resin composite, preheated resin composite and dual self-adhesive resin cement as dentin luting agents. Materials and Methods: Occlusal thirds of molar teeth were cut and randomly divided into 3 groups to be cemented: RelyX™U200, Filtek™ Z250 XT- preheated to 70° and Filtek Flow™ Z350XT. They were then thermocycled 5000 times between 5+/-2°C and 55+/-2°C. Subsequently, 10 microbars per group were prepared. The 30 samples were placed in saline solution for 24 hours at room temperature prior to microtensile test. This was performed with a digital universal testing machine at a crosshead speed of 0.5 mm/min. The bond strength values obtained were analyzed in Megapascals (MPa). Measures of central tendency such mean and measures of dispersion such standard deviation were used. In addition, the Kruskall Wallis non-parametric test with Bonferroni post hoc test was applied, considering a significance value of 5% (P < 0.05), with type I error. Results: The dentin microtensile bond strengths of preheated resin composite, flowable resin composite and dual self-adhesive cement were 6.08 ± 0.66 Mpa, 5.25 ± 2.60Mpa and 2.82 ± 1.26Mpa, respectively. In addition, the preheated resin composite exhibited significantly higher microtensile bond strength compared to the dual self-adhesive cement (P < 0.001). While the flowable resin composite showed no significant difference with the dual self-adhesive cement (P = 0.054) and the preheated resin composite (P = 0.329). Conclusions: The microtensile bond strength in dentin was significantly higher when using a preheated resin composite at 70°C as a luting agent compared to dual self-adhesive cement. However, the preheated resin composite showed similar microtensile bond strength compared to the flowable resin composite.

4.
J Int Soc Prev Community Dent ; 13(2): 114-123, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37223443

RESUMO

Aim: The surface roughness of dental restorations can decrease resin durability, since it leads to its deterioration, color variation, and loss of gloss. Therefore, the aim was to assess the surface roughness of nanoparticle resin composites, subjected to two different polishing systems. Materials and Methods: This longitudinal in vitro experimental study consisted of 32 resin specimens made according to ISO 4049-2019 and divided equally into four groups: A1: Palfique LX5 / Sof-Lex, A2: Palfique LX5 / Super Snap, B1: Filtek Z350 XT / Sof-Lex, and B2: Filtek Z350 XT / Super Snap. The samples were stored in distilled water at 37°C for 24 h. Surface roughness was measured with a digital roughness tester, both before and after the polishing procedure. The data were analyzed with the Student's t-test for related samples, and with the inter-subject ANOVA test with two factors; considering significance at P < 0.05. Results: The surface roughness of Palfique LX5 resin with the Sof-lex system was 0.330 (CI: 0.282-0.378 µm) and 0.170 (CI: 0.087-0.253 µm) before and after polishing, respectively. With the Super Snap system, values of 0.448 (CI: 0.346-0.549 µm) and 0.206 (CI: 0.130-0.282 µm) were obtained before and after polishing, respectively. For the Filtek Z350 XT resin, the surface roughness obtained with the Sof-lex system was 0.353 (CI: 0.278-0.427 µm) and 0.134 (CI: 0.095-0.172 µm) before and after polishing, respectively. With the Super Snap system, values of 0.334 (CI: 0.247-0.421 µm) and 0.171 (CI: 0.122-0.221 µm) were obtained before and after polishing, respectively. Surface roughness did not show significant differences in all groups assessed both before (P = 0.068) and after (P = 0.335) polishing. However, before and after the application of the polishing systems, all groups significantly decreased their surface roughness (P < 0.05). Further, when comparing this decrease among all groups, no significant differences were observed (P = 0.437). Conclusion: The surface roughness of the Filtek Z350 XT and Palfique LX5 nanoparticle resin composites showed no significant differences when using the Sof-lex and Super Snap polishing systems. However, both polishing systems significantly decreased the surface roughness of the nanoparticulated resins, with this decrease being similar in all groups.

5.
Sci Rep ; 12(1): 14752, 2022 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-36042268

RESUMO

Peru was the country with the highest COVID-19 case fatality rate worldwide during second wave of infection, with dentists and pre-professional students being susceptible to infection due to clinical procedures they perform. This situation could have generated some kind of psychological disorder within this group. Therefore, the present study aimed to assess how COVID-19 pandemic affected this population group during second wave, in relation to depression, anxiety and stress. This observational and cross-sectional study in 368 Peruvian dentists (186 students and 182 professionals), was carried out during August to November 2021. The DASS-21 Scale was used to diagnose depression, anxiety and stress. For the statistical analysis, Pearson's chi-square test was used, in addition to a logit model using odds ratio (OR) to evaluate depression, anxiety and stress with the following factors: gender, age group, marital status, monthly family income, children, academic level, history of COVID-19, COVID-19 symptomatology, close relative with COVID-19, living with vulnerable people and work dedication. In addition, predictive models were constructed considering all possible significant causes. A significance level of p < 0.05 was considered. Dental students and professionals presented significant differences in levels of depression, anxiety and stress (p < 0.001, p = 0.022, p = 0.001; respectively). Male students were 56% less likely to develop stress (OR 0.44; CI 0.22-0.85) compared to females; while those unmarried were 81% less likely to develop stress (OR 0.19; CI 0.04-0.85). Likewise, those with children were 83% less likely to develop stress (OR 0.17; CI 0.06-0.52) and 65% less likely to develop depression (OR 0.35; CI 0.15-0.80). In addition, COVID-19 asymptomatics were 60% less likely to develop depression (OR 0.40; CI 0.17-0.92). However, having relatives with COVID-19 caused almost three times the probability of developing depression (OR 2.96; CI 1.29-6.79) and twice the probability of developing stress (OR 2.49; CI 1.07-5.78). As for dental professionals, it was noticed that those unmarried had almost three times the probability of developing stress (OR 2.93; CI 1.38-6.23); while those who only worked had twice the probability of developing stress (OR 2.37; CI 1.17-4.78). Dental students had a higher prevalence of depression, anxiety and stress. In addition, having children and being asymptomatic were protective predictors for depression, while being male, unmarried and having children were protective predictors for stress. However, having a relative with COVID-19 was a risk predictor for depression and stress. In professionals, only working and being unmarried were risk predictors for stress.


Assuntos
COVID-19 , Pandemias , Ansiedade/psicologia , COVID-19/epidemiologia , Criança , Estudos Transversais , Depressão/psicologia , Feminino , Humanos , Masculino , SARS-CoV-2 , Estresse Psicológico/epidemiologia , Estresse Psicológico/psicologia , Estudantes de Odontologia
6.
Polymers (Basel) ; 14(15)2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-35956567

RESUMO

The aim of this study was to assess the microhardness and surface roughness of bulk-fill resin composites treated with and without the application of an oxygen-inhibited layer (OIL) and a polishing system. This in vitro experimental study consisted of 72 resin composite blocks divided into three groups: Tetric N-Ceram Bulk Fill, Opus Bulk Fill APS, and Filtek Bulk Fill. Each resin composite group was further divided into two subgroups: with and without OIL control. Subsequently, surface roughness and microhardness were measured before and after polishing. A t-test was used to compare independent and related measures. For the intergroup comparison of variation before and after polishing, the Kruskal−Wallis test with Bonferroni post hoc was used considering a significance level of p < 0.05. When comparing surface roughness, significant differences were observed between Opus Bulk Fill resin composite with and without OIL control (p = 0.003) before polishing. The same occurred when comparing Tetric N-Ceram resin composite with and without OIL control (p = 0.039) after polishing. In addition, the surface roughness of Filtek Bulk Fill, Opus Bulk Fill, and Tetric N-Ceram Bulk Fill resin composites, with and without OIL control, decreased significantly after polishing (p < 0.001), while surface microhardness significantly increased (p < 0.05), with the exception of Opus Bulk Fill resin with OIL control (p = 0.413). In conclusion, OIL control and polishing significantly improved the surface roughness and surface microhardness of Filtek Bulk Fill and Tetric N-Ceram Bulk Fill resin composites. However, in the case of Opus Bulk Fill resin composite, only its surface roughness was significantly improved.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA