Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Echocardiography ; 41(6): e15861, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38853674

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Assuntos
Ecocardiografia Transesofagiana , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Ecocardiografia Transesofagiana/métodos , Feminino , Masculino , Estudos Prospectivos , Insuficiência da Valva Tricúspide/cirurgia , Idoso , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais
2.
Echocardiography ; 40(2): 147-152, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36636809

RESUMO

Edge-to-edge tricuspid transcatheter repair requires extensive echocardiographic planning before the procedure. Sometimes, anatomic features may anticipate a suboptimal result. For this reason, a tailored strategy is the key to the procedural success. We report a case of massive tricuspid regurgitation due to multiple complex mechanisms that was successfully treated by clipping the antero-septal commissure to restore functional coaptation of the valve leaflets at multiple sites.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
3.
Int J Mol Sci ; 24(12)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37373551

RESUMO

SARS-CoV-2 vaccination offered the opportunity to emerge from the pandemic and, thereby, worldwide health, social, and economic disasters. However, in addition to efficacy, safety is an important issue for any vaccine. The mRNA-based vaccine platform is considered to be safe, but side effects are being reported more frequently as more and more people around the world become treated. Myopericarditis is the major, but not the only cardiovascular complication of this vaccine; hence it is important not to underestimate other side effects. We report a case series of patients affected by cardiac arrhythmias post-mRNA vaccine from our clinical practice and the literature. Reviewing the official vigilance database, we found that heart rhythm disorders after COVID vaccination are not uncommon and deserve more clinical and scientific attention. Since the COVID vaccine is the only vaccination related to this side effect, questions arose about whether these vaccines could affect heart conduction. Although the risk-benefit ratio is clearly in favor of vaccination, heart rhythm disorders are not a negligible issue, and there are red flags in the literature about the risk of post-vaccination malignant arrhythmias in some predisposed patients. In light of these findings, we reviewed the potential molecular pathways for the COVID vaccine to impact cardiac electrophysiology and cause heart rhythm disorders.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Humanos , Arritmias Cardíacas/etiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , SARS-CoV-2 , Vacinação/efeitos adversos
4.
Monaldi Arch Chest Dis ; 94(1)2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36883984

RESUMO

A 55-year-old male affected by heart failure with reduced ejection fraction and a history of a transient cerebrovascular accident was accepted to the Cardiology Department for worsening dyspnea. A cardiopulmonary exercise test was performed after therapy optimization to further evaluate exercise intolerance. A rapid increase in the minute ventilation/carbon dioxide production slope, end-tidal oxygen pressure, and respiratory exchange ratio, with a concomitant decrease in end-tidal carbon dioxide pressure and oxygen saturation, were observed during the test. These findings indicate exercise-induced pulmonary hypertension leading to a right-to-left shunt. Subsequent echocardiography with a bubble test unveiled the presence of an unknown patent foramen ovale. It is, therefore, necessary to exclude a right-to-left shunt by cardiopulmonary exercise testing, particularly in patients predisposed to develop pulmonary hypertension during exercise. Indeed, this eventuality might potentially provoke severe cardiovascular embolisms. However, the patent foramen ovale closure in patients with heart failure with reduced ejection fraction is still debated because of its potential hemodynamic worsening.


Assuntos
Forame Oval Patente , Insuficiência Cardíaca , Hipertensão Pulmonar , Masculino , Humanos , Pessoa de Meia-Idade , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Dióxido de Carbono , Ecocardiografia
5.
Int J Mol Sci ; 23(13)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35806265

RESUMO

Coronary artery disease (CAD) remains one of the most important causes of morbidity and mortality worldwide, and revascularization through percutaneous coronary interventions (PCI) significantly improves survival. In this setting, poor glycaemic control, regardless of diabetes, has been associated with increased incidence of peri-procedural and long-term complications and worse prognosis. Novel antidiabetic agents have represented a paradigm shift in managing patients with diabetes and cardiovascular diseases. However, limited data are reported so far in patients undergoing coronary stenting. This review intends to provide an overview of the biological mechanisms underlying hyperglycaemia-induced vascular damage and the contrasting actions of new antidiabetic drugs. We summarize existing evidence on the effects of these drugs in the setting of PCI, addressing pre-clinical and clinical studies and drug-drug interactions with antiplatelet agents, thus highlighting new opportunities for optimal long-term management of these patients.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Hiperglicemia , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/complicações , Diabetes Mellitus/tratamento farmacológico , Controle Glicêmico , Humanos , Hiperglicemia/complicações , Hiperglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Resultado do Tratamento
6.
Aging Clin Exp Res ; 33(7): 1875-1883, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33001403

RESUMO

BACKGROUND: Management of elderly patients with acute myocardial infarction (AMI) is challenging due to lack of knowledge about the link between fragility, outcomes and interventional procedures. AIMS: The aim of this study was to establish the prognostic role of the Multidimensional Prognostic Index (MPI) in elderly with AMI. METHODS: A total of 241 patients ≥ 65 years old with AMI were continuously enrolled in this prospective study and divided into three groups according to the MPI score. The primary endpoint was 30-day mortality. Secondary endpoints were 6-month mortality and rate of adverse events. RESULTS: In-hospital overall mortality rate was higher in MPI-3 (p = 0.009). Patients of MPI-3 had a significantly higher mortality rate regarding the primary endpoint with 30-day survival of 78.9%, compared to 97.4% and 97.2%, in MPI-1, MPI-2 (p < 0.001), respectively. The survival rate progressively decreased in the three MPI classes of risk with a 6-month survival of 96.5%, 96.3%, 73.7% in groups MPI-1, MPI-2, and MPI-3 (p < 0.001). Longer length of in-hospital stay was observed in MPI-3 group. In-hospital complications were more frequent in higher MPI score. DISCUSSION: Our findings are in agreement with the results of other studies that evaluated the risk of in-hospital complications and mortality in older patients. In our "real-world" population of elderly hospitalized for AMI we observed poorer outcomes in patients belonged to higher MPI groups. CONCLUSIONS: In the setting of AMI, MPI may be very useful in the daily clinical practice to manage older patients and predict the risk of in-hospital and follow-up complications.


Assuntos
Avaliação Geriátrica , Infarto do Miocárdio , Idoso , Humanos , Tempo de Internação , Prognóstico , Estudos Prospectivos , Fatores de Risco
7.
Surg Technol Int ; 39: 303-307, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34749422

RESUMO

Bicuspid aortic valve (BAV) disease is the most common congenital abnormality and is characterized by a risk of premature aortic valve disease, predominantly aortic stenosis. Surgery remains the treatment of choice for patients with symptomatic BAV disease, but, in patients who are unsuitable for surgical aortic valve replacement, transcatheter aortic valve replacement (TAVR) is currently used as an alternative to surgery, although there is no official recommendation for their management, since BAV patients with severe aortic stenosis have been excluded from the major TAVR randomized clinical trials. Patients with BAV stenosis present anatomic challenges for treatment with TAVR. The BAV annulus often has an elliptical shape and is larger than the tricuspid valve, and is more likely to exhibit severe eccentric calcification. In addition, BAV is often associated with a dilated, horizontal ascending aorta, and effaced sinuses. The calcified raphe may also place differential stress on the expansion of the transcatheter valve, increasing the risk of suboptimal positioning and consequently the risk of paravalvular leakage, new pacemaker implantation, new-onset left bundle branch block, and annular rupture. Moreover, coronary obstruction may occur when leaflet fusion results in a longer leaflet. Although some of these challenges have been successfully overcome using new-generation devices, the complication rate is still relatively high and requires a deeper understanding of the patient's specific complex and variable anatomy. Selection of the type and size of the transcatheter valve according to the patient's individual anatomy is critical to achieving successful results. Therefore, given the increasing frequency of BAV stenosis in younger patients, and the worldwide expansion in the application of TAVR in younger and lower surgical-risk patients, preprocedural multimodality imaging involving CT scan and three-dimensional echocardiography is mandatory to understand the complex and variable anatomy of BAV disease and improve both procedural results and short- and long-term outcomes in these patients.


Assuntos
Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Humanos , Seleção de Pacientes , Resultado do Tratamento
8.
Heart Fail Clin ; 17(4): 607-618, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34511209

RESUMO

In heart failure with reduced ejection fraction, the interventional landscape has recently expanded. New transcatheter approaches are emerging for both mitral and tricuspid secondary (functional) regurgitation. Transcatheter therapies for mitral and tricuspid valve require a more tailored approach than for the aortic valve, because of more heterogeneous clinical scenarios, anatomic features, and mechanisms of valvular lesions.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Insuficiência Cardíaca/cirurgia , Humanos , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
9.
Catheter Cardiovasc Interv ; 88(2): 307-11, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26354685

RESUMO

Transcatheter edge-to-edge mitral valve repair with MitraClip System (Abbott Vascular, Menlo Park, CA) needs a trans-septal access for positioning the 22-Fr guiding catheter in the left atrium. To the best of our knowledge no data are currently available about the hemodynamic consequences of a congenital atrial septal defect (ASD) after MitraClip repair. We report a case of MitraClip repair in a patient with ostium secundum ASD and ischemic cardiomyopathy, who needed intraprocedural closure of the defect for serious hemodynamic complications, secondary to worsening of the right ventricular function, increased pulmonary pressure and inversion of the interatrial shunt in right-to-left direction. These events, which were exacerbated by high blood levels of PaCO2 for the anesthesiological protocol used, led to left-side low-output syndrome and cardiorespiratory arrest. © 2015 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/cirurgia , Hemodinâmica , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Idoso , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Resultado do Tratamento
10.
Heart Vessels ; 31(10): 1633-42, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26694720

RESUMO

Transcatheter MitraClip repair is a new tool for the management of severe mitral regurgitation in patients at very high risk for conventional surgery. Aim of our study was reporting one-year clinical outcomes in candidates to MitraClip procedures, divided into three groups according to the cardiovascular medicine heart failure (CVM-HF) index. The study population consists of 46 consecutive patients, divided, in accordance with CVM-HF index, as follows: one patient in the low-risk category (group A); 27 patients in the medium-risk (group B) and 18 patients in high-risk category (group C). The primary study endpoint was a combined of all-cause mortality and re-hospitalization rate. Secondary endpoints were all-cause mortality and cardiac mortality. Patients of group B and group C were compared. Regarding the primary endpoint, patients in group C had significantly poorer outcomes than patients in group B, with a 12-month survival freedom from events of 44.4  and 74.1 %, respectively (log-rank test, p = 0.039); survival freedom from cardiac mortality was 100 and 83.3 % in group B and C, respectively (log-rank test, p = 0.027). One-year survival free from re-hospitalization was 74.1 % in group B and 39.9 % in group C (log-rank test; p = 0.036). Survival free from all-cause of mortality was 92.6 and 77.8 %, respectively (log-rank test; p = 0.129). In our initial experience the CVM-HF index showed to be valuable for understanding if the patient with advanced heart failure and functional mitral regurgitation can really benefit by MitraClip therapy.


Assuntos
Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/diagnóstico , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Readmissão do Paciente/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Teste de Esforço , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 83(2): 291-6, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23436381

RESUMO

We report the first human case of percutaneous edge-to-edge mitral valve repair using MitraClip System (Abbott Vascular, Abbott Park, IL) in a patient, who previously underwent left atrial appendage closure with PLAATO™ System (ev3. Inc., Plymouth, MN). The procedure was successfully performed using the standard MitraClip technique, in the catheterization laboratory, with transesophageal echocardiographic and fluoroscopic guidance. We showed that a double percutaneous procedure for stroke prevention and mitral regurgitation treatment might be a valid approach in selected patients ineligible for chronic anticoagulation therapy and at high risk for conventional cardiac surgery.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Instrumentos Cirúrgicos , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Fluoroscopia , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Radiografia Intervencionista/métodos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
12.
J Cardiovasc Dev Dis ; 11(2)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38392253

RESUMO

Takotsubo syndrome (TTS) is a clinical condition characterized by temporary regional wall motion anomalies and dysfunction that extend beyond a single epicardial vascular distribution. Various pathophysiological mechanisms, including inflammation, microvascular dysfunction, direct catecholamine toxicity, metabolic changes, sympathetic overdrive-mediated multi-vessel epicardial spasms, and transitory ischemia may cause the observed reversible myocardial stunning. Despite the fact that TTS usually has an acute coronary syndrome-like pattern of presentation, the absence of culprit atherosclerotic coronary artery disease is often reported at coronary angiography. However, the idea that coronary artery disease (CAD) and TTS conditions are mutually exclusive has been cast into doubt by numerous recent studies suggesting that CAD may coexist in many TTS patients, with significant clinical and prognostic repercussions. Whether the relationship between CAD and TTS is a mere coincidence or a bidirectional cause-and-effect is still up for debate, and misdiagnosis of the two disorders could lead to improper patient treatment with unfavourable outcomes. Therefore, this review seeks to provide a profound understanding of the relationship between CAD and TTS by analyzing potential common underlying pathways, addressing challenges in differential diagnosis, and discussing medical and procedural techniques to treat these conditions appropriately.

13.
JACC Case Rep ; 5: 101685, 2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36636505

RESUMO

Restrictive physiology, such as cardiac amyloidosis, compromises atrial and ventricular performance, often leading to "atrial" functional valvular regurgitation. While focusing on atrial functional tricuspid regurgitation we aimed at summarizing the pathophysiological characteristics of, and therapeutic options in, cardiac amyloidosis. (Level of Difficulty: Intermediate.).

14.
Front Cardiovasc Med ; 10: 1134828, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37123469

RESUMO

The most common organic etiology of mitral regurgitation is degenerative and consists of mitral valve prolapse (MVP). Volume overload because of mitral regurgitation is the most common complication of MVP. Advocating surgery before the consequences of volume overload become irreparable restores life expectancy, but carries a risk of mortality in patients who are often asymptomatic. On the other hand, the post-surgical outcome of symptomatic patients is dismal and life expectancy is impaired. In the present article, we aim to bridge the gap between these two therapeutic approaches, unifying the concepts of watchful waiting and early surgery in a "watchful surgery approach".

15.
J Clin Med ; 12(9)2023 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-37176756

RESUMO

Functional mitral regurgitation (FMR) and tricuspid regurgitation (FTR) occur due to cardiac remodeling in the presence of structurally normal valve apparatus. Two main mechanisms are involved, distinguishing an atrial functional form (when annulus dilatation is predominant) and a ventricular form (when ventricular remodeling and dysfunction predominate). Both affect the prognosis of patients with heart failure (HF) across the entire spectrum of left ventricle ejection fraction (LVEF), including preserved (HFpEF), mildly reduced (HFmrEF), or reduced (HFrEF). Currently, data on the management of functional valve regurgitation in the various HF phenotypes are limited. This review summarizes the epidemiology, pathophysiology, and treatment of FMR and FTR within the different patterns of HF, as defined by LVEF.

16.
J Clin Med ; 12(10)2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37240669

RESUMO

Observing mitral or tricuspid valve disease in an athlete raises many considerations for the clinician. Initially, the etiology must be clarified, with causes differing depending on whether the athlete is young or a master. Notably, vigorous training in competitive athletes leads to a constellation of structural and functional adaptations involving cardiac chambers and atrioventricular valve systems. In addition, a proper evaluation of the athlete with valve disease is necessary to evaluate the eligibility for competitive sports and identify those requiring more follow-up. Indeed, some valve pathologies are associated with an increased risk of severe arrhythmias and potentially sudden cardiac death. Traditional and advanced imaging modalities help clarify clinical doubts, allowing essential information about the athlete's physiology and differentiating between primary valve diseases from those secondary to training-related cardiac adaptations. Remarkably, another application of multimodality imaging is evaluating athletes with valve diseases during exercise to reproduce the sport setting and better characterize the etiology and valve defect mechanism. This review aims to analyze the possible causes of atrioventricular valve diseases in athletes, focusing primarily on imaging applications in diagnosis and risk stratification.

17.
J Clin Med ; 12(5)2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36902497

RESUMO

BACKGROUND: Cardiac computed tomography (CT) provides important insights into the geometrical configuration of the tricuspid valve (TV). The purpose of the present study was to assess the geometrical changes of TV in patients with functional tricuspid regurgitation (TR) using novel CT scan parameters and to correlate these findings with echocardiography. METHODS: This single-center study enrolled 86 patients undergoing cardiac CT and divided them into two groups according to the presence or not of severe TR (43 patients with TR ≥ 3+ and 43 controls). The measurements collected were as follows: TV annulus area and perimeter, septal-lateral and antero-posterior annulus diameters, eccentricity, distance between commissures, segment between the geometrical centroid and commissures, and the angles of commissures. RESULTS: We found a significant correlation between all annulus measurements and the grade of TR, except in regard to angles. TR ≥ 3+ patients had significantly larger TV annulus area and perimeter, larger septal-lateral, and antero-posterior annulus dimensions, as well as larger commissural distance and centroid-commissural distance. In patients with TR ≥ 3+ and controls, the eccentricity index predicted a circular shape and an oval shape of the annulus, respectively. CONCLUSIONS: These novel CT variables focusing on commissures increase the anatomical understanding of the TV apparatus and the TV geometrical changes in patients with severe functional TR.

18.
Minerva Cardiol Angiol ; 71(1): 12-19, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36305773

RESUMO

BACKGROUND: The COVID-19 pandemic severely impacted global health. The aim of this study was to compare predictors of symptoms-to-emergency-call timing delay in acute coronary syndrome (ACS) and their impact on mortality before and during the COVID-19 outbreak. METHODS: We collected sociodemographic, clinical data, procedural features, preadmission and intra-hospital outcomes of consecutive patients admitted for ACS in seventeen Italian centers from March to April 2018, 2019, and 2020. RESULTS: In 2020, a 32.92% reduction in ACS admissions was observed compared to 2018 and 2019. Unstable angina, typical and atypical symptoms, and intermittent angina were identified as significant predictors of symptoms-to-emergency-call timing delay before and during the COVID-19 pandemic (P<0.005 for all the items). Differently from 2018-2019, during the pandemic, hypertension and dyspnea (P=0.002 versus P=0.490 and P=0.001 vs. P=0.761 for 2018-2019 and 2020, respectively) did not result as predictors of delay in symptoms-to-emergency-call timing. Among these predictors, only the atypical symptoms (HR 3.36; 95% CI: 1.172-9.667, P=0.024) in 2020 and the dyspnea (HR 2.64; 95% CI: 1.345-5.190, P=0.005) in 2018-2019 resulted significantly associated with higher mortality. Finally, the family attendance at the onset of the symptoms resulted in a reduction in symptoms-to-emergency-call timing (in 2020 P<0.001; CI: -1710.73; -493.19) and in a trend of reduced mortality (HR 0.31; 95% CI: 0.089-1.079, P=0.066) in 2020. CONCLUSIONS: During the COVID-19 outbreak, atypical symptoms and family attendance at ACS onset were identified, respectively, as adverse and favorable predictors of symptoms-to-emergency-call timing delay and mortality.


Assuntos
Síndrome Coronariana Aguda , COVID-19 , Humanos , COVID-19/epidemiologia , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/epidemiologia , Pandemias , Angina Instável/epidemiologia , Dispneia/epidemiologia
19.
Am Heart J ; 163(4): 684-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22520535

RESUMO

BACKGROUND: Multislice computed tomography (MSCT) has generally been accepted as the most accurate modality fulfilling this purpose with good reproducibility. A major drawback of MSCT consists in the use of contrast dye, which may be unsafe in transcatheter aortic valve implantation (TAVI) patients who frequently are affected by renal failure. We sought to appraise the accuracy of intracardiac echocardiography (ICE) in measurements of structures in the aortic root in patients undergoing TAVI. METHODS: Aortic annulus and sinus of Valsalva diameters were measured using ICE, performed during standard invasive preprocedural assessment in 30 consecutive patients with severe aortic stenosis referred for TAVI. Multislice computed tomography was performed in all patients afterward, and aortic root measurements were made by an independent radiologist. RESULTS: Effective ICE measurements were obtained in all patients, easily and without any complication. Mean aortic annulus diameters were 21.9 ± 1.8 mm using ICE, 22.0 ± 1.9 mm using MSCT (3-chamber [3-C] view) and 22.8 ± 1.8 mm using the mean of long-axis and short-axis (L-ax/S-ax) view MSCT (P = .192, ICE vs 3-C MSCT; P < .001, ICE vs L-ax/S-ax MSCT, respectively). Correlation between ICE and both MSCT measurements was good (r(2) = 0.83, P < .001; r(2) = 0.80, P < .001, respectively). Mean sinus of Valsalva diameters were 32.3 ± 3.3 mm using ICE and 32.5 ± 3.1 mm using 3-C MSCT view (P = .141). Even in this case, correlation between ICE and both MSCT measurements was excellent (r(2) = 0.96, P < .001). CONCLUSIONS: In patients referred for TAVI, measurements of the aortic annulus and the sinus of Valsalva using ICE compare favorably with those made at MSCT. This approach might be a useful and reproducible strategy in patients with severe renal impairment to avoid the administration of contrast dye during MSCT.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Seio Aórtico/diagnóstico por imagem , Ultrassonografia de Intervenção , Adulto , Ecocardiografia/métodos , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Estudos Prospectivos , Reprodutibilidade dos Testes
20.
Catheter Cardiovasc Interv ; 79(1): 132-40, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21538786

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an emerging alternative to medical therapy reserved to a limited population with severe aortic stenosis. The European consensus document recommended TAVI for prohibitive-risk patients not eligible for conventional surgery (prohibitive risk defined as expected mortality ≥ 20% calculated with the Logistic EuroScore (LES) in association with clinical judgment). To date, there is lack of clarity on data about outcomes of TAVI in lower risk patients. We sought to evaluate the outcomes of patients undergoing TAVI with LES ≥ 20% in comparison with patients with LES < 20%. METHOD: Of 165 patients who underwent TAVI using the 18-French Medtronic CoreValve (N = 153) and the Sapien Edwards™ (N = 12) at our Institution between June 2007 and September 2010, we identified those with LES < 20%, with prosthesis implantation (n = 84), and reported on their clinical outcome compared with patients with LES ≥ 20% (n = 78). The primary endpoint was the incidence of overall death and major adverse cerebrovascular and cardiac events (MACCE) at 30-day and midterm follow-up stratifying patients by clinical characteristics. RESULTS: At 30-day, a significant higher incidence of MACCE (20.8% vs. 6.0%, odds ratio [OR] 4.08 95% confidence interval [CI] 1.42-11.74, P = 0.009) and death (15.6% vs. 2.4%, OR 7.45 95% CI 1.61-34.48, P = 0.010) was reported in the LES ≥ 20% group as compared with the LES < 20% group, respectively. The 12-month MACCE rates was (27.1% vs. 11.4%, hazard ratio [HR] 2.47 95% CI 0.93-6.63, P = 0. 071) for LES ≥ 20% and LES < 20% patients, respectively (mortality rates was 25.7% vs. 6.8% HR 4.21 95% CI 1.24-14.30, P = 0.021). CONCLUSION: This study tends to suggest that current mortality reported after TAVI could be significantly affected by the very-high risk profile of the population which currently undergoes this procedure, making comparison with surgical series rather unreliable.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Transtornos Cerebrovasculares/etiologia , Distribuição de Qui-Quadrado , Feminino , Cardiopatias/etiologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Itália , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Razão de Chances , Seleção de Pacientes , Modelos de Riscos Proporcionais , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA