Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
2.
J Pers Med ; 12(6)2022 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-35743719

RESUMO

Maxillofacial ballistic trauma represents a devastating functional and aesthetic trauma. The extensive damage to soft and hard tissue is unpredictable, and because of the diversity and the complexity of these traumas, a systematic algorithm is essential. This study attempts to define the best management of maxillofacial ballistic injuries and to describe a standardized, surgical and prosthetic rehabilitation protocol from the first emergency stage up until the complete aesthetic and functional rehabilitation. In low-velocity ballistic injuries (bullet speed <600 m/s), the wound is usually less severe and not-fatal, and the management should be based on early and definitive surgery associated with reconstruction, followed by oral rehabilitation. High-velocity ballistic injuries (bullet speed >600 m/s) are associated with an extensive hard and soft tissue disruption, and the management should be based on a three-stage reconstructive algorithm: debridement and fixation, reconstruction, and final revision. Rehabilitating a patient with ballistic trauma is a multi-step challenging treatment procedure that requires a long time and a multidisciplinary team to ensure successful results. The prosthodontic treatment outcome is one of the most important parameters by which a patient measures the restoration of aesthetic, functional, and psychological deficits. This study is a retrospective review: twenty-two patients diagnosed with outcomes of ballistic traumas were identified from the department database, and eleven patients met the inclusion criteria and were enrolled.

3.
J Pers Med ; 13(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36675726

RESUMO

A palatal fistula is a pathological condition that connects the nasal cavities with the oral cavity. An oral-nasal fistula is reported as a possible post-surgical complication after the removal of oral carcinomas. The presence of a palatal fistula affects the patient's quality of life, making it necessary to apply a prosthetic device, such as a palatal plate, to keep the nasal cavities separated from the oral one. There are several surgical techniques to close a palatal fistula, but it is not possible to define the optimal technique as the approach is extremely dependent on the characteristics of the fistula. The aim of this article is to propose a minimally invasive technique to reduce the size of palatal fistulae and to reduce the surgical difficulty (NSPF). A total of 20 patients fulfilled the inclusion criteria and were checked every two weeks. The fistula was injured with a needle every 2 weeks. Fifteen patients who healed with complete closure of the fistula reported no need for a palatal protection plate to eat, drink and speak normally. It is possible to conclude that the NSPF protocol is a valid approach for the non-surgical reduction of palatal fistulae, and it is possible, when the appropriate conditions are present, to achieve complete closure.

4.
Diagnostics (Basel) ; 12(8)2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-36010214

RESUMO

(1) Background: Patients with head and neck cancer are treated by ablative surgery, radiotherapy, chemotherapy, or a combination of these. The side effects of cancer therapies can compromise conventional prosthesis rehabilitation; therefore, dental implants can result in a more effective solution. The aim of the study is to explain how to rehabilitate a patient that underwent head and neck cancer therapy. (2) Methods: This retrospective study conducted from 2015 to 2021 included 223 postoncological patients, aged between 32 and 80 years old. Eighteen patients did not proceed with any treatment, and two died. Therefore, 203 patients have been analyzed and rehabilitated following our decisional protocol, with a mean period of follow-up of 4 years. The implant placement was considered successful when a mean bone loss of 1.6 mm for the first year and a mean of 0.13 mm in subsequent years occurred (3) Results: A total of 161 patients were rehabilitated with a conventional prosthesis, 42 patients (F:M ratio 19:23) with an implant-supported prosthesis and a total of 200 implants were placed; 9 implants were lost (4.5% of 200 implants). Conclusions: The results confirmed that by following our protocol it is possible to obtain an acceptable rate of implant survival, considering the delicacy and complexity of post-oncological patients.

5.
J Endod ; 47(3): 472-476, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33096192

RESUMO

INTRODUCTION: Previously published studies have deeply investigated the characteristics of flexural and torsional resistance of nickel-titanium rotary instruments, but none of them investigated the relationship between the 2 stresses. The objective of the present study was to evaluate the influence of flexural stresses over torsional resistance. METHODS: Sixty S-One 20.04 files (Fanta Dental, Shanghai, China) were used in the present study (N = 60) and divided into 3 test groups of 20 files. A customized device made of a mobile structure with a connection that holds the handpiece and the artificial canal was used for the experiment to make the measurements repeatable. The artificial canals were created with a 90° curvature, a 60° curvature, and lastly a straight canal. Each file was rotated at 300 rpm with a maximum torque value of 5.5 Ncm with the apical 2 mm firmly secured in a vise. The torque at fracture and the time to fracture were recorded by the software integrated in the handpiece and evaluated through statistical analysis. RESULTS: Statistical analysis found significant differences in the values of torque to fracture (TtF) between these 3 groups (P < .05). The 90° curved canal group showed the highest TtF value, and the 60° curved canal group showed a higher TtF value than the straight canal group. CONCLUSIONS: The results of the present study demonstrated a positive influence of flexural stresses over torque at fracture of rotary files. When nickel-titanium instruments were used in a 90° or 60° curvature, the values of torque at fracture increased compared with the same instruments that rotated in the straight canal.


Assuntos
Níquel , Titânio , China , Ligas Dentárias , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento , Preparo de Canal Radicular , Torque , Torção Mecânica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA