Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Aesthetic Plast Surg ; 48(4): 568-579, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37608189

RESUMO

BACKGROUND: Although three-dimensional (3D) simulations are becoming more common in preoperative breast augmentation planning, this does not necessarily imply that the simulated results are highly accurate. OBJECTIVES: We aimed to evaluate the accuracy of the 3D simulation technique by comparing the differences in breast morphology between the 3D prediction model and the actual results. METHODS: The simulation and actual postoperative results of 103 patients who underwent breast augmentation were analyzed retrospectively. Therefore, a 3D model was created, and the parameters of line spacing, nipple position, breast projection, surface area, and volume were evaluated. Furthermore, consider the difference in chest circumferences and breast volume. RESULTS: In comparison with the simulation results, the actual results had a mean increase in the nipple to the inframammary fold (N-IMF) of 0.3 cm (P < 0.05) and a mean increase in basal breast width (BW) of 0.3 cm (P < 0.001), a difference that was not statistically significant in patients with larger breast volumes. There was a significant difference in the mean upper and lower breast volume distribution between simulated and actual breasts (upper pole 52.9% vs. 49.2%, P < 0.05, and lower pole 47.1% vs. 50.8%, P < 0.001). However, it was not statistically significant in patients with larger chest circumferences. CONCLUSIONS: Our study shows that 3D simulation has uncertainties related to the patient's chest circumference and breast volume. Therefore, these two critical factors must be considered when using simulation assessment in preoperative planning. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Implantes de Mama , Mamoplastia , Humanos , Estudos Retrospectivos , Estudos de Coortes , Resultado do Tratamento , Mamoplastia/métodos , Mamilos/cirurgia , Estética
2.
Aesthetic Plast Surg ; 48(9): 1698-1705, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38480656

RESUMO

BACKGROUND: Knowledge of the anatomy of the infraorbital artery (IOA) is crucial for the rejuvenation of the anterior medial aspect of the midface; however, studies adequately describing the anatomy of the IOA branches are lacking, and their connection with the ophthalmic artery branches remains unclear. OBJECTIVES: This study aims to elucidate the anatomical characteristics of the IOA in its deployment within the lower eyelid using three-dimensional (3D) technology, thereby offering an anatomical foundation for clinical surgical procedures. METHODS: An analysis was conducted on computed tomography scans of 132 cadaveric head sides post-contrast injection, utilizing the Mimics software for reconstruction. The study focused on examining the anastomosis of the IOA, its principal branches, and the branches emanating from the ophthalmic artery. RESULTS: The prevalence of type I IOA was observed at 38.6% (51/132), while Type II IOA was found in 61.4% (81/132) of cases. A 7.6% incidence (10/132) of IOA directly anastomosing with the angular artery was noted. The presence of palpebral branches (PIOA) was identified in 57.6% (76/132) of instances. In the lower eyelid, four distinct distribution patterns of IOA were discerned: The likelihood of Type I PIOA was 5.3%, whereas for Types IIA, IIB, and IIC PIOA, the probabilities were 8.3%, 32.6%, and 11.4%, respectively. The occurrence of the orbital branch of IOA was recorded at 41.7% (55/132). CONCLUSIONS: 3D technology can map IOA variants and identify the deployment patterns of IOA branches in the lower eyelid vascular vesicles at high resolution as a guide in clinical practice. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Cadáver , Imageamento Tridimensional , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Feminino , Masculino , Pálpebras/irrigação sanguínea , Pálpebras/diagnóstico por imagem , Pálpebras/anatomia & histologia , Órbita/irrigação sanguínea , Órbita/diagnóstico por imagem , Órbita/anatomia & histologia , Artéria Oftálmica/anatomia & histologia , Artéria Oftálmica/diagnóstico por imagem , Idoso , Pessoa de Meia-Idade , Variação Anatômica , Idoso de 80 Anos ou mais , Artérias/anatomia & histologia , Artérias/diagnóstico por imagem , Relevância Clínica
3.
Aesthetic Plast Surg ; 48(12): 2231-2238, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38528128

RESUMO

BACKGROUND:  Infraorbital filler injection is a commonly used minimally invasive cosmetic procedure on the face, which can cause vascular complications. OBJECTIVE:  In this study, we aimed to explore the anatomical structure of the infraorbital vasculature and to establish an accurate protocol for infraorbital filler injection. METHODS:  The vascular structure of the infraorbital region was evaluated in 84 hemifacial specimens using computed tomography. Four segments (P1-P4) and five sections (C1-C5) were considered. We recorded the number of identified arteries in each slice and at each location and the number of deep arteries. Furthermore, we also measured the infraorbital artery (IOA) distribution. RESULTS:  At P1-P4, the lowest number of arteries was detected in segment P4, with a 317/1727 (18.4%) and 65/338 (2.3%) probability of total and deep arterial identification, respectively. The probabilities of encountering an identified artery at the five designated locations (C1-C5) were 277/1727 (16%), 318/1727 (18.4%), 410/1727 (23.7%), 397/1727 (23%), and 325/1727 (18.8%), respectively. The probability of an IOA being identified at C2 was 68/84 (81%). CONCLUSION:  We described an effective filler injection technique in the infraorbital region to minimize the associated risks. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Preenchedores Dérmicos , Órbita , Humanos , Feminino , Masculino , Preenchedores Dérmicos/efeitos adversos , Preenchedores Dérmicos/administração & dosagem , Órbita/irrigação sanguínea , Técnicas Cosméticas/efeitos adversos , Cadáver , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Idoso , Face/irrigação sanguínea , Idoso de 80 Anos ou mais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA