Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
G Ital Cardiol (Rome) ; 18(6): 525-528, 2017 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-28631767

RESUMO

Pseudoaneurysm of the mitral-aortic intervalvular fibrosa (MAIVF-P) is one of the rare complications of endocarditis or, more rarely, of surgical trauma. This condition is characterized by a pseudoaneurysm in the intra-annular area between the mitral valve and the aortic valve communicating with the outflow tract of the left ventricle, between the coronary or noncoronary left aortic valve and the front flap of the mitral valve. Nowadays, surgery is recommended to avoid further growth and complications. We hereby describe the case of a patient with MAIVF-P as a consequence of a surgical trauma and early appearance of MAIVF-P. During the long echocardiographic and clinical follow-up, the patients showed stable clinical and hemodynamic conditions despite the increase in size of the MAIVF-P. A conservative treatment based on a medical follow-up can represent an alternative in patients refusing surgery, in high-risk surgical patients as well as in patients showing a stable echocardiographic and clinical picture regardless of the MAIVF-P size.


Assuntos
Falso Aneurisma/terapia , Valva Aórtica/patologia , Tratamento Conservador , Doenças das Valvas Cardíacas/terapia , Valva Mitral/patologia , Complicações Pós-Operatórias/terapia , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Valva Aórtica/diagnóstico por imagem , Bioprótese , Diagnóstico Diferencial , Progressão da Doença , Ecocardiografia , Feminino , Seguimentos , Aneurisma Cardíaco/diagnóstico , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Imageamento Tridimensional , Valva Mitral/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Tomografia Computadorizada por Raios X , Recusa do Paciente ao Tratamento
2.
Eur J Radiol ; 75(2): 212-4, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19481400

RESUMO

PURPOSE: The aim of this study was to evaluate reproducibility of a fast MRI protocol to measure gastric emptying and motility of the gastric antrum. METHODS AND MATERIALS: Gastric emptying and antral speed were measured in 12 type 1 diabetic patients (mean age 43 years) and 9 healthy volunteers (mean age 31 years). Subjects, fasting from 6h, were evaluated in supine position using a 1.5T MR scanner and a eight-channels phased-array body coil after ingestion of 400 ml of a vanillas pudding mixed with 5 ml of Gd-DTPA. Axial 3D T1w sequence at 0 and 30 min for volume evaluation and cine-steady state acquisition every 5 min for a total time of 30 min for gastric wave speed assessing were acquired. Two blinded observers extrapolated T(1/2) from gastric volume assessment and speed of gastric waves. RESULTS: All the patients tolerated the examination. The T(1/2) cut-off was of 115 min with an accuracy in differentiate controls from diabetics of 96% (95% CI 0.766-0.992; p<0.001), while the antral speed cut-off was of 0.15 mm/s with an accuracy of 87% (95% CI 0.628-0.977; p<0.001). The inter-observer agreement for the volumes at time 0 and 30 min was respectively 0.983 (95% CI 0.9628-0.9929; p<0.001) and 0.9933 (95% CI 0.9847-0.9971; p<0.001) with an agreement of 0.9918 (95% CI 0.9853-0.9954; p<0.001), while for antral speed it was of 0.935 (95% CI 0.9097-0.9528; p<0.001). CONCLUSIONS: MRI is a reproducible technique for the evaluation of gastric emptying and antral motility.


Assuntos
Esvaziamento Gástrico , Motilidade Gastrointestinal , Imageamento por Ressonância Magnética/métodos , Antro Pilórico/fisiopatologia , Adulto , Meios de Contraste , Diabetes Mellitus Tipo 1/fisiopatologia , Estudos de Viabilidade , Feminino , Gadolínio DTPA , Humanos , Masculino , Antro Pilórico/patologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA