Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Foot Ankle Surg ; 27(2): 168-174, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32370949

RESUMO

BACKGROUND: For the diagnosis and treatment of foot and ankle disorders, objective quantification of the absolute and relative orientation angles is necessary. The present work aims at assessing novel techniques for 3D measures of foot bone angles from current Cone-Beam technology. METHODS: A normal foot was scanned via weight-bearing CT and 3D-model of each bone was obtained. Principal Component Analysis, landmark-based and mid-diaphyseal axes were exploited to obtain bone anatomical references. Absolute and relative angles between calcaneus and first metatarsal bone were calculated both in 3D and in a simulated sagittal projections. The effects of malpositioning were also investigated via rotations of the entire foot model. RESULTS: Large angle variations were found between the different definitions. For the 3D relative orientation, variations larger than 10 degrees were found. Foot malposition in axial rotation or in varus/valgus can result in errors larger than 5 and 3 degrees, respectively. CONCLUSIONS: New measures of foot bone orientation are possible in 3D and in weight-bearing, removing operator variability and the effects of foot positioning.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Ossos do Pé/diagnóstico por imagem , Imageamento Tridimensional , Modelagem Computacional Específica para o Paciente , Suporte de Carga , Calcâneo , Humanos , Masculino , Ossos do Metatarso , Adulto Jovem
2.
Foot Ankle Surg ; 27(2): 150-155, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32381452

RESUMO

BACKGROUND: In severe cases of ankle and subtalar arthritis, arthrodesis of the subtalar joint is performed in combination with ankle arthroplasty. In these special cases gait analysis reveals real motion at the replaced tibiotalar joint. METHODS: Twenty-three patients affected by ankle and subtalar arthritis, treated either with a 3-component or a 2-component prosthesis in combination with subtalar arthrodesis, were clinically evaluated preoperatively and at a minimum of 1-year follow-up. Gait analysis was performed postoperatively using a multi-segment foot protocol. Foot kinematics were compared to corresponding data from a healthy control group. RESULTS: Clinical scores significantly improved from preoperative to follow-up. The clinically measured passive ankle dorsiflexion/plantarflexion significantly improved at the follow-up. Patients' normalized walking speed and stride length were significantly lower than those in control. With exception of the ankle frontal-plane motion, sagittal-plane mobility of foot joints was about 50% than that in healthy joints. CONCLUSIONS: Improvement in clinical scores was found for both prostheses. Normal spatio-temporal parameters were not restored. In these patients, fusion of the subtalar joint appeared to be compensated by larger frontal-plane motion at the tibiotalar joint. LEVEL OF EVIDENCE: Level III- retrospective comparative study. The study was approved by the local Ethics Committee as protocol MAT (protocol registration at clinicaltrials.gov NCT03356951).


Assuntos
Artrite/cirurgia , Artrodese , Artroplastia de Substituição do Tornozelo , Articulações do Pé/fisiopatologia , Amplitude de Movimento Articular , Articulação Talocalcânea/cirurgia , Adulto , Idoso , Artrite/fisiopatologia , Fenômenos Biomecânicos , Feminino , Marcha/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Foot Ankle Surg ; 26(5): 509-517, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31402285

RESUMO

BACKGROUND: For the diagnosis and treatment of the foot and ankle, bone alignments have long been evaluated using planar radiographs in weight-bearing conditions and a large number of measurements have been reported. The present survey reviews the major radiographic angles that are currently present in the literature for a possible better comprehension and classification of them. METHODS: PubMed and Google Scholar were used to retrieve technical and clinical papers related to these angles, and were classified based on five typologies and the three projection planes. These angles were grouped into one definition if they described similar concepts, regardless of their anatomical references and names. A corresponding original definition and diagrammatic representation are offered. RESULTS: Thirty-one conceptual radiographic angles were identified across all descriptions from the literature: 18 in the sagittal plane, 9 in the transverse, and 4 in the coronal. Most angular measures represent relative bone orientations; absolute orientations, bone morphology and joint lines are less frequently used or reported. CONCLUSIONS: The present survey reveals a confused scenario of angular measures, particularly in terms of anatomical references and names. It is therefore recommended to establish common relevant techniques and terminology.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Radiografia/métodos , Suporte de Carga/fisiologia , Articulação do Tornozelo/fisiologia , Humanos
4.
Semin Musculoskelet Radiol ; 23(6): 643-656, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31745954

RESUMO

Musculoskeletal radiology has been mostly limited by the option between imaging under load but in two dimensions (i.e., radiographs) and three-dimensional (3D) scans but in unloaded conditions (i.e., computed tomography [CT] and magnetic resonance imaging in a supine position). Cone-beam technology is now also a way to image the extremities with 3D and weight-bearing CT. This article discusses the initial experience over a few studies in progress at an orthopaedic center. The custom design of total ankle replacements, the patellofemoral alignment after medial ligament reconstruction, the overall architecture of the foot bones in the diabetic foot, and the radiographic assessment of the rearfoot after subtalar fusion for correction of severe flat foot have all taken advantage of the 3D and weight-bearing feature of relevant CT scans. To further support these novel assessments, techniques have been developed to obtain 3D models of the bones from the scans and to merge these with state-of-the-art gait analyses.


Assuntos
Doenças do Pé/diagnóstico por imagem , Articulações do Pé/diagnóstico por imagem , Análise da Marcha/métodos , Artropatias/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Suporte de Carga , Pé/diagnóstico por imagem , Humanos , Imageamento Tridimensional
5.
J Orthop Traumatol ; 17(3): 249-54, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26883439

RESUMO

BACKGROUND: Aggressive bone neoplasms, such as giant cell tumors, often affect the proximal tibia warranting bony resection via curettage leaving behind massive defects that require extensive reconstruction. Reconstruction is usually accomplished with poly(methyl methacrylate) (PMMA) packing supplemented with an internal fixation construct. The purpose of this study is to compare Steinmann pin augmentation to locking plate constructs to determine which offers the stiffer reconstruction option. MATERIALS AND METHODS: Large defects were created below the lateral condyle of fresh frozen tibias. The defects extended for an average of 35 mm beneath the lateral plateau in the frontal plane, and from the anterior to posterior cortex in the sagittal plane. Distally the defect extended for an average of 35 mm to the metadiaphyseal junction. In the Pin group, the tibias were reconstructed with three 4-mm diameter Steinmann pins placed in the medullary canal and PMMA packing. In the Plate group, the tibias were reconstructed with a 6-hole 3.5-mm LCP Proximal locking plate fixed to the proximal-lateral tibia utilizing seven 3.5-mm screws and PMMA packing. The tibias were tested for stiffness on a MTS machine by applying up to 400 N to the tibial plateau in force control at 5 N/s. Fatigue properties were tested by applying a haversine loading waveform between 200 N and 1,200 N at 3 Hz simulating walking upstairs/downstairs. RESULTS: Locking plate constructs (801.8 ± 78 N/mm) had greater (p = 0.041) stiffness than tibial constructs fixed with Steinmann pins (646.5 ± 206.3 N/mm). CONCLUSIONS: Permanent deformation was similar between the Pin and Plate group; however, two tibia from the Pin group exhibited displacements >5 mm which we considered failure. LEVEL OF EVIDENCE: n/a.


Assuntos
Pinos Ortopédicos , Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Tíbia/patologia , Tíbia/cirurgia , Cadáver , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Polimetil Metacrilato , Resultado do Tratamento
6.
J Neuroeng Rehabil ; 11: 136, 2014 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-25212257

RESUMO

BACKGROUND: Several rehabilitation systems based on inertial measurement units (IMU) are entering the market for the control of exercises and to measure performance progression, particularly for recovery after lower limb orthopaedic treatments. IMU are easy to wear also by the patient alone, but the extent to which IMU's malpositioning in routine use can affect the accuracy of the measurements is not known. A new such system (Riablo™, CoRehab, Trento, Italy), using audio-visual biofeedback based on videogames, was assessed against state-of-the-art gait analysis as the gold standard. METHODS: The sensitivity of the system to errors in the IMU's position and orientation was measured in 5 healthy subjects performing two hip joint motion exercises. Root mean square deviation was used to assess differences in the system's kinematic output between the erroneous and correct IMU position and orientation.In order to estimate the system's accuracy, thorax and knee joint motion of 17 healthy subjects were tracked during the execution of standard rehabilitation tasks and compared with the corresponding measurements obtained with an established gait protocol using stereophotogrammetry. RESULTS: A maximum mean error of 3.1 ± 1.8 deg and 1.9 ± 0.8 deg from the angle trajectory with correct IMU position was recorded respectively in the medio-lateral malposition and frontal-plane misalignment tests. Across the standard rehabilitation tasks, the mean distance between the IMU and gait analysis systems was on average smaller than 5°. CONCLUSIONS: These findings showed that the tested IMU based system has the necessary accuracy to be safely utilized in rehabilitation programs after orthopaedic treatments of the lower limb.


Assuntos
Biorretroalimentação Psicológica/instrumentação , Marcha/fisiologia , Modalidades de Fisioterapia/instrumentação , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Fotogrametria/métodos
7.
J Hand Surg Am ; 39(10): 1971-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25257487

RESUMO

PURPOSE: To determine in a cadaver model which, among 5 fixation methods for proximal interphalangeal (PIP) joint arthrodesis, has the greatest stiffness. METHODS: Thirty-five cadaver digits were randomly assigned to 1 of 5 fixation groups: oblique K-wire with coronal intraosseous wiring, tension-band wire (TBW), dorsal plate, intramedullary linked screw (IMS), and 90/90 wiring (90/90W). Testing was done by applying bending moments to the PIP joint in the sagittal and frontal planes. The force/displacement curves were used to estimate the stiffness of each construct. Ultimate strength was determined by loading to failure in extension. RESULTS: The IMS had significantly higher stiffness than all wiring constructs in all planes of motion and significantly greater stiffness in extension than the dorsal plate. The IMS stiffness exceeded 10 N/mm across all bending directions and showed an ultimate strength of 21 N. The plate demonstrated higher stiffness in radial bending than the oblique K-wire with coronal intraosseous wiring and TBW. There were no differences in stiffness between the IMS and plate in all modes of testing except extension. Load-to-failure testing of the devices showed the IMS device to be significantly stronger than the TBW, 90/90W, and plating constructs. CONCLUSIONS: The IMS resisted larger bending moments than all wiring constructs and showed the greatest ultimate strength when compared with 3 of the tested arthrodesis techniques. The plate was significantly better than 2 of the wiring constructs, but only in radial bending. No differences were found between the, TBW, and 90/90W when compared with each other. CLINICAL RELEVANCE: The stiffness necessary for a successful PIP joint fusion has not been quantified, but according to this study, the IMS was the most favorable biomechanical construct for initial stability.


Assuntos
Artrodese/instrumentação , Articulações dos Dedos/cirurgia , Adulto , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fios Ortopédicos , Cadáver , Feminino , Articulações dos Dedos/diagnóstico por imagem , Articulações dos Dedos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia
8.
Gait Posture ; 100: 268-275, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36682320

RESUMO

BACKGROUND: Adult acquired flat foot (AAFF) is a symptomatic postural alteration of the foot due to modifications in bony structures and/or soft tissues supporting the medial longitudinal arch. For the most severe cases, when orthotic solutions do not provide enough pain relief, surgery may be necessary. RESEARCH QUESTION: Is it possible to restore a normal medial longitudinal arch and to correct the static and dynamic frontal plane alignment of the rearfoot via a modified Grice surgical procedure in AAFF patients? METHODS: Eleven patients with stage II AAFF were recruited in the study and underwent the Grice procedure. Patients were assessed via gait analysis using a validated multi-segment foot protocol. Double-leg standing static posture and foot joint kinematics during barefoot walking were measured before surgery and at a mean follow-up of 15 ± 8 months. Twenty-seven age-matched healthy subjects without foot morphological alterations were used as control. Patients' feet were clinically assessed via the Foot Function Index and the Foot Posture Index. Wilcoxon signed rank test was used to assess differences in kinematic and spatio-temporal parameters between pre-op and follow-up evaluations. 1D statistical parametric mapping was used to assess differences in temporal profiles of foot joint rotations. RESULTS: The clinical indexes significantly improved at post-op (p < 0.05). No differences in sagittal plane static and dynamic joint rotations were observed between pre-op and post-op. In the frontal plane, metatarsus to calcaneus and midfoot to calcaneus rotation angles significantly improved from pre-op to post-op, with the latter resulting consistent with control data. Range of motion and maximum value of the medial longitudinal arch angle were reduced following surgery. SIGNIFICANCE: The modified Grice procedure restored a good frontal-plane alignment of rearfoot and midfoot, and the clinical scores provided evidence of its effectiveness in significantly reducing pain and improving the quality of daily activities.


Assuntos
Pé Chato , Humanos , Adulto , Fenômenos Biomecânicos , , Artrodese , Dor , Marcha
9.
J Foot Ankle Res ; 15(1): 38, 2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35585544

RESUMO

Ankle-Foot Orthoses (AFO) can be prescribed to allow drop-foot patients to restore a quasi-normal gait pattern. Standard off-the-shelf AFOs are cost-effective solutions to treat most patients with foot and ankle weakness, but these devices have several limitations, especially in terms of comfort. Therefore, custom AFOs are increasingly adopted to address drop-foot when standard solutions are not adequate. While the solid ones are the most common type of AFO, providing full stability and strong resistance to ankle plantarflexion, passive dynamic AFOs (PD-AFOs) represent the ideal solution for patients with less severe ankle weakness. PD-AFOs have a flexible calf shell, which can bend during the stance phase of walking and absorb energy that can be released to support the limb in the push-off phase. The aim of this review is to assess the state-of-the-art and identify the current limitations of PD-AFOs. An extensive literature review was performed in Google Scholar to identify all studies on custom PD-AFOs. Only those papers reporting on custom PD-AFOs were included in the review. Non peer-reviewed papers, abstract shorter than three pages, lecture notes and thesis dissertations were excluded from the analysis. Particular attention was given to the customization principles and the mechanical and functional tests. For each topic, the main results from all relevant papers are reported and summarized herein. There were 75 papers that corresponded to the search criteria. These were grouped according to the following macro-topics: 16 focusing on scanning technologies and geometry acquisition; 14 on customization criteria; 19 on production techniques; 16 on mechanical testing, and 33 on functional testing. According to the present review, design and production of custom PD-AFOs are becoming increasingly feasible due to advancements in 3D scanning techniques and additive manufacturing. In general, custom PD-AFOs were shown to provide better comfort and improved spatio-temporal parameters with respect to standard solutions. However, no customization principle to adapt PD-AFO stiffness to the patient's degree of ankle impairment or mechanical/functional demand has thus far been proposed.


Assuntos
Órtoses do Pé , Tornozelo , Articulação do Tornozelo , Fenômenos Biomecânicos , Marcha , Humanos , Debilidade Muscular , Caminhada
10.
Front Bioeng Biotechnol ; 10: 862254, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35782520

RESUMO

Objective: Osteoarthritis (OA) is a multifactorial musculoskeletal disorder affecting mostly weight-bearing joints. Chondrocyte response to load is modulated by inflammatory mediators and factors involved in extracellular cartilage matrix (ECM) maintenance, but regulatory mechanisms are not fully clarified yet. By using a recently proposed experimental model combining biomechanical data with cartilage molecular information, basally and following ex-vivo load application, we aimed at improving the understanding of human cartilage response to cyclic mechanical compressive stimuli by including cartilage original anatomical position and OA degree as independent factors. Methods: 19 mono-compartmental Knee OA patients undergoing total knee replacement were recruited. Cartilage explants from four different femoral condyles zones and with different degeneration levels were collected. The response of cartilage samples, pooled according to OA score and anatomical position was tested ex-vivo in a bioreactor. Mechanical stimulation was obtained via a 3-MPa 1-Hz sinusoidal compressive load for 45-min to replicate average knee loading during normal walking. Samples were analysed for chondrocyte gene expression and ECM factor release. Results: Non parametric univariate and multivariate (generalized linear mixed model) analysis was performed to evaluate the effect of compression and IL-1ß stimulation in relationship to the anatomical position, local disease severity and clinical parameters with a level of significance set at 0.05. We observed an anti-inflammatory effect of compression inducing a significant downmodulation of IL-6 and IL-8 levels correlated to the anatomical regions, but not to OA score. Moreover, ADAMTS5, PIICP, COMP and CS were upregulated by compression, whereas COL-2CAV was downmodulated, all in relationship to the anatomical position and to the OA degree. Conclusion: While unconfined compression testing may not be fully representative of the in-vivo biomechanical situation, this study demonstrates the importance to consider the original cartilage anatomical position for a reliable biomolecular analysis of knee OA metabolism following mechanical stimulation.

11.
J Sports Med Phys Fitness ; 62(3): 350-355, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34137570

RESUMO

BACKGROUND: Asymmetrical posture maintained over long training periods may affect phenotypic plasticity, resulting functional to sporting goal but negative to the locomotor system. Aim of this study was to quantitatively evaluate these long-term effects in competitive boxers. METHODS: Baropodometric analysis was used to assess 20 competitive boxers and 20 non-sportsmen in upright bipedal posture for 5 s and for 51.2 s with open (OE) and closed (CE) eyes. RESULTS: The boxers' group (BOX) showed a larger total foot load (TFL) (p=0.022) on the right foot and a larger rearfoot load (RfL) (P=0.011) on the left foot compared to non-sport controls (CTR). Moreover, a larger forefoot load (FfL) (P=0.001) on the right foot respect to left one was found in the BOX group, with the inversion of the RfL to FfL ratio (P=0.001) between two feet, while no significant differences were found in the CTR group. These findings, associated to a significantly larger center of foot angle (COF) in the BOX group, may indicate an anticlockwise rotation of the anatomical structures above the ankle joint of the right hemisoma respect to the left one, that appears to be consistent with the orthodox stance. Eventually, the BOX group showed a larger centre-of-pressure sway area (COPsa) in the OE condition than what measured in the CE and a significant difference in Romberg Index (BOX< CTR). CONCLUSIONS: The results of this study seem to confirm the theory of neuromuscular plasticity imprinted by the repetitive movements and long-lasting postures. Moreover, competitive boxers show an increase of proprioceptive function and a decrease of visual dependence on the postural control.


Assuntos
Boxe , Humanos , Equilíbrio Postural , Postura , Rotação , Posição Ortostática
12.
Artigo em Inglês | MEDLINE | ID: mdl-35270606

RESUMO

Background: Postural stability and plantar pressure parameters can be assessed by baropodometry; nevertheless, they are often affected by low repeatability. The aim of the study was to test the accuracy and repeatability of a novel resistive sensor pressure plate and to establish the most reliable baropodometric parameters. Methods: Accuracy and repeatability of the FM12050 BTS-Bioengineering plate measurements were assessed by using different weights in static conditions across three sessions. Subsequently, 20 healthy subjects were assessed by 30-s stabilometric analysis in bipedal standing with open eyes across four trials in two sessions, morning and afternoon. Results: Pressure plate repeatability in measuring the static weights was very high, and plate measurements were correlated to the scale measurements (Pearson's coefficient = 0.99). Percentage of load distribution between left and right foot and in rearfoot and forefoot regions showed the largest repeatability (coefficient of variation < 5%) across trials. Eventually, median and percentiles (25−75%) were reported for each parameter. Conclusions: This study helped to assess the accuracy and repeatability of a novel pressure plate in static conditions and to define the most reliable parameters for the assessment of postural stability and foot morphology. The present healthy-subject stabilometric dataset may be used as reference data in the evaluation of pathological populations.


Assuntos
, Extremidade Inferior , Voluntários Saudáveis , Humanos , Equilíbrio Postural
13.
Front Bioeng Biotechnol ; 10: 890428, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35497357

RESUMO

This study investigated the effectiveness of an 8-week foot-core exercise training program on foot-ankle kinematics during running and also on running kinetics (impact loads), with particular interest in biomechanical outcomes considered risk factors for running-related injuries in recreational runners. A single-blind, randomized, controlled trial was conducted with 87 recreational runners randomly allocated to either the control (CG) or intervention (IG) group and assessed at baseline and after 8 weeks. The IG underwent foot-core training 3 times/week, while the CG followed a placebo lower-limb stretching protocol. The participants ran on a force-instrumented treadmill at a self-selected speed while foot-segment motion was captured simultaneously with kinetic measurements. After the intervention, there were statistically significant changed in foot biomechanics, such as: IG participants strike the ground with a more inverted calcaneus and a less dorsiflexed midfoot than those in the CG; at midstance, ran with a less plantarflexed and more adducted forefoot and a more abducted hallux; and at push-off, ran with a less dorsiflexed midfoot and a less adducted and more dorsiflexed hallux. The IG runners also had significantly decreased medial longitudinal arch excursion (p = 0.024) and increased rearfoot inversion (p = 0.037). The 8-week foot-core exercise program had no effect on impact (p = 0.129) and breaking forces (p = 0.934) or on vertical loading rate (p = 0.537), but it was positively effective in changing foot-ankle kinematic patterns."

14.
J Foot Ankle Res ; 14(1): 18, 2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33731179

RESUMO

BACKGROUND: Foot healthcare research is focusing increasingly on personalized orthotic and prosthetic devices to address patient-specific morphology and ailments. Customization requires advanced 3D image processing tools to assess foot and leg geometrical parameters and alterations. The aim of this study is to present a new software for the measurement of the foot shape from 3D scans of the foot plantar surface. METHODS: A Kinect-based scanning device was used to acquire the 3D foot shape of 44 healthy subjects. A software was developed in Matlab to measure the foot main morphological parameters from foot scans. Principal Component Analysis was used to orientate the foot scans with respect to the same reference system. Accuracy, via percentage errors and Bland-Altman plots, and correlation of the software-based foot parameters were assessed against manual measurements. A normalized Arch Volume Index (nAVI) was proposed and correlated to the traditional Arch Index. Test-retest Intraclass Correlation Coefficient was used to assess the inter-session repeatability of foot measurements. RESULTS: The average percentage error between software and manual measurements was 1.2 ± 0.8% for foot length, 9.1 ± 3.7% for foot width, 22.3 ± 13.5% for arch height and 23.1 ± 12.7% for arch depth. Very strong correlations were observed for foot length (R = 0.97) and foot width (R = 0.83), and strong correlations for arch height (R = 0.62) and arch depth (R = 0.74). nAVI was negatively correlated to the Arch Index (R = -0.54). A small difference was found between software and manual measurements of foot length (Δ = 0.92 mm), a software overestimation of foot width (Δ = 8.6 mm) and underestimation of arch height (Δ = -1.4%) and arch depth (Δ = -11%). Moderate to excellent repeatability was observed for all measurements (0.67-0.99). CONCLUSIONS: The present software appears capable to estimate the foot main morphological parameters without the need for skin markers or for identification of anatomical landmarks. Moreover, measurements are not affected by the foot orientation on the scanning device. The good accuracy and repeatability of measurements make the software a potentially useful operator-independent tool for the assessment of foot morphological alterations and for orthotics customization. nAVI may be used for a more realistic classification of foot types when 3D foot images are available.


Assuntos
Dermatoglifia , Pé/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Podiatria/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Software , Adulto Jovem
15.
J Biomech ; 125: 110581, 2021 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-34217032

RESUMO

The foot is anatomically and functionally complex, and thus an accurate description of intrinsic kinematics for clinical or sports applications requires multiple segments. This has led to the development of many multi-segment foot models for both kinematic and kinetic analyses. These models differ in the number of segments analyzed, bony landmarks identified, required marker set, defined anatomical axes and frames, the convention used to calculate joint rotations and the determination of neutral positions or other offsets from neutral. Many of these models lack validation. The terminology used is inconsistent and frequently confusing. Biomechanical and clinical studies using these models should use established references and describe how results are obtained and reported. The International Society of Biomechanics has previously published proposals for standards regarding kinematic and kinetic measurements in biomechanical research, and in this paper also addresses multi-segment foot kinematics modeling. The scope of this work is not to prescribe a particular set of standard definitions to be used in all applications, but rather to recommend a set of standards for collecting, calculating and reporting relevant data. The present paper includes recommendations for the overall modeling and grouping of the foot bones, for defining landmarks and other anatomical references, for addressing the many experimental issues in motion data collection, for analysing and reporting relevant results and finally for designing clinical and biomechanical studies in large populations by selecting the most suitable protocol for the specific application. These recommendations should also be applied when writing manuscripts and abstracts.


Assuntos
, Marcha , Fenômenos Biomecânicos , Articulações do Pé , Pele
16.
J Mech Behav Biomed Mater ; 121: 104608, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34077904

RESUMO

One of the main biomechanical causes for aseptic failure of orthopaedic implants is the stress shielding. This is caused by an uneven load distribution across the bone normally due to a stiff metal prosthesis component, leading to periprosthetic bone resorption and to implant loosening. To reduce the stress shielding and to improve osseointegration, biocompatible porous structures suitable for orthopaedic applications have been developed. Aim of this study was to propose a novel in-vitro model of the mechanical interaction between metal lattice structures and bovine cortical bone in compression. Analysis of the strain distribution between metal structure and bone provides useful information on the potential stress shielding of orthopaedic implants with the same geometry of the porous scaffold. Full density and lattice structures obtained by the repetition of 1.5 mm edge cubic elements via Laser Powder Bed Fusion of CoCrMo powder were characterized for mechanical properties using standard compressive testing. The two porous geometries were characterized by 750 µm and 1000 µm pores resulting in a nominal porosity of 43.5% and 63.2% respectively. Local deformation and strains of metal samples coupled with fresh bovine cortical bone samples were evaluated via Digital Image Correlation analysis up to failure in compression. Visualization and quantification of the local strain gradient across the metal-bone interface was used to assess differences in mechanical behaviour between structures which could be associated to stress-shielding. Overall stiffness and local mechanical properties of lattice and bone were consistent across samples. Full-density metal samples appeared to rigidly transfer the compression force to the bone which was subjected to large deformations (2.2 ± 0.3% at 15 kN). Larger porosity lattice was associated to lower stiffness and compressive modulus, and to a smoother load transfer to the bone. While tested on a limited sample size, the proposed in-vitro model appears robust and repeatable to assess the local mechanical interaction of metal samples suitable for orthopaedic applications with the bone tissue. CoCrMo scaffolds made of 1000 µm pores cubic cells may allow for a smoother load transfer to the bone when used as constitutive material of orthopaedic implants.


Assuntos
Ortopedia , Animais , Osso e Ossos , Bovinos , Porosidade , Próteses e Implantes , Estresse Mecânico , Titânio
17.
Front Bioeng Biotechnol ; 9: 634327, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34012954

RESUMO

Osteoarthritis (OA) is an evolving disease and a major cause of pain and impaired mobility. A deeper understanding of cartilage metabolism in response to loading is critical to achieve greater insight into OA mechanisms. While physiological joint loading helps maintain cartilage integrity, reduced or excessive loading have catabolic effects. The main scope of this study is to present an original methodology potentially capable to elucidate the effect of cyclic joint loading on cartilage metabolism, to identify mechanisms involved in preventing or slowing down OA progression, and to provide preliminary data on its application. In the proposed protocol, the combination of biomechanical data and medical imaging are integrated with molecular information about chondrocyte mechanotransduction and tissue homeostasis. The protocol appears to be flexible and suitable to analyze human OA knee cartilage explants, with different degrees of degeneration, undergoing ex vivo realistic cyclic joint loading estimated via gait analysis in patients simulating mild activities of daily living. The modulation of molecules involved in cartilage homeostasis, mechanotransduction, inflammation, pain and wound healing can be analyzed in chondrocytes and culture supernatants. A thorough analysis performed with the proposed methodology, combining in vivo functional biomechanical evaluations with ex vivo molecular assessments is expected to provide new insights on the beneficial effects of physiological loading and contribute to the design and optimization of non-pharmacological treatments limiting OA progression.

18.
J Biomed Mater Res B Appl Biomater ; 109(12): 2091-2103, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33964120

RESUMO

Human bones are biological examples of functionally graded lattice capable to withstand large in vivo loading and allowing optimal stress distribution. Disruption of bone integrity may require biocompatible implants capable to restore the original bone structure and properties. This study aimed at comparing mechanical properties and biological behavior in vitro of uniform (POR-FIX) and graded (POR-VAR) Cobalt-chrome alloy lattice structures manufactured via Selective Laser Melting. In compression, the POR-VAR equivalent maximum stress was about 2.5 times lower than that of the POR-FIX. According to the DIC analysis, the graded lattice structures showed a stratified deformation associated to unit cells variation. At each timepoint, osteoblast cells were observed to colonize the surface and the first layer of both scaffolds. Cell activity was always significantly higher in the POR-VAR (p < 0.0005). In terms of gene expression, the OPG/RANKL ratio increased significantly over time (p < 0.0005) whereas IL1ß and COX2 significantly decreased (7 day vs 1 day; p < 0.0005) in both scaffolds. Both uniform- and graded-porosity scaffolds provided a suitable environment for osteoblasts colonization and proliferation, but graded structures seem to represent a better solution to improve stress distribution between implant and bone of orthopedic implants.


Assuntos
Ligas , Próteses e Implantes , Ligas/química , Ligas de Cromo , Cobalto/farmacologia , Humanos , Osteoblastos/metabolismo , Porosidade , Titânio/química
19.
J Biomech ; 128: 110711, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34481280

RESUMO

Static and dynamic measurements of the medial longitudinal arch (MLA) in the foot are critical across different clinical and biomechanical research fields. While MLA deformation can be estimated using skin-markers for gait analysis, the current understanding of the correlates between skin-marker based models and radiographic measures of the MLA is limited. This study aimed at assessing the correlation and accuracy of skin-marker based measures of MLA deformation with respect to standard clinical X-ray based measures, used as reference. 20 asymptomatic subjects without morphological alterations of the foot volunteered in the study. A lateral X-ray of the right foot of each subject was taken in monopodalic upright posture with and without a metatarsophalangeal-joint dorsiflexing wedge. MLA angle was estimated in the two foot postures and during gait using 16 skin-marker based models, which were established according to the marker set of a validated multi-segment foot kinematic protocol. The error of each model in tracking MLA deformation was assessed and correlated with respect to standard radiographic measurements. Estimation of MLA deformation was highly affected by the skin-marker models. Skin-marker models using the marker on the navicular tuberosity as apex of the MLA angle showed the smallest errors (about 2 deg) and the largest correlations (R = 0.64-0.65; p < 0.05) with respect to the radiographic measurements. According to the outcome of this study, skin-marker based definitions of the MLA angle using the navicular tuberosity as apex of the arch may provide a more accurate estimation of MLA deformation with respect to that from radiographic measures.


Assuntos
, Ossos do Tarso , Fenômenos Biomecânicos , Pé/diagnóstico por imagem , Marcha , Humanos , Postura
20.
J Anat ; 217(3): 254-61, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20646107

RESUMO

The plantar aponeurosis (PA), in spanning the whole length of the plantar aspect of the foot, is clearly identified as one of the key structures that is likely to affect compliance and stability of the longitudinal arch. A recent study performed in our laboratory showed that tension/elongation in the PA can be predicted from the kinematics of the segments to which the PA is attached. In the present investigation, stereophotogrammetry and inverse kinematics were employed to shed light on the mechanics of the longitudinal arch and its main passive stabilizer, the PA, in relation to walking speed. When compared with a neutral unloaded position, the medial longitudinal arch underwent greater collapse during the weight-acceptance phase of stance at higher walking speed (0.1 degrees +/-1.9 degrees in slow walking; 0.9 degrees +/-2.6 degrees in fast walking; P = 0.0368). During late stance the arch was higher (3.4 degrees +/-3.1 degrees in slow walking; 2.8 degrees +/-2.7 degrees in fast walking; P = 0.0227) and the metatarsophalangeal joints more dorsiflexed (e.g. at the first metatarsophalangeal joint, 52 degrees +/-5 degrees in slow walking; 64 degrees +/-4 degrees in fast walking; P < 0.001) during fast walking. Early-stance tension in the PA increased with speed, whereas maximum tension during late stance did not seem to be significantly affected by walking speed. Although, on the one hand, these results give evidence for the existence of a pre-heel-strike, speed-dependent, arch-stiffening mechanism, on the other hand they suggest that augmentation of arch height in late stance is enhanced by higher forces exerted by the intrinsic muscles on the plantar aspect of the foot when walking at faster speeds.


Assuntos
Fáscia/fisiologia , Pé/fisiologia , Caminhada/fisiologia , Tendão do Calcâneo/anatomia & histologia , Tendão do Calcâneo/fisiologia , Adulto , Fenômenos Biomecânicos , Fáscia/anatomia & histologia , Pé/anatomia & histologia , Humanos , Articulação Metatarsofalângica/fisiologia , Fotogrametria/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA