Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 197
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 26(1): 101007, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38316344

RESUMO

BACKGROUND: Quantitative cardiovascular magnetic resonance (CMR) first pass perfusion maps are conventionally acquired with 3 short-axis (SAX) views (basal, mid, and apical) in every heartbeat (3SAX/1RR). Thus, a significant part of the left ventricle (LV) myocardium, including the apex, is not covered. The aims of this study were 1) to investigate if perfusion maps acquired with 3 short-axis views sampled every other RR-interval (2RR) yield comparable quantitative measures of myocardial perfusion (MP) as 1RR and 2) to assess if acquiring 3 additional perfusion views (i.e., total of 6) every other RR-interval (2RR) increases diagnostic confidence. METHODS: In 287 patients with suspected ischemic heart disease stress and rest MP were performed on clinical indication on a 1.5T MR scanner. Eighty-three patients were examined by acquiring 3 short-axis perfusion maps with 1RR sampling (3SAX/1RR); for which also 2RR maps were reconstructed. Additionally, in 103 patients 3 short-axis and 3 long-axis (LAX; 2-, 3, and 4-chamber view) perfusion maps were acquired using 2RR sampling (3SAX + 3LAX/2RR) and in 101 patients 6 short-axis perfusion maps using 2RR sampling (6SAX/2RR) were acquired. The diagnostic confidence for ruling in or out stress-induced ischemia was scored according to a Likert scale (certain ischemia [2 points], probably ischemia [1 point], uncertain [0 points], probably no ischemia [1 point], certain no ischemia [2 points]). RESULTS: There was a strong correlation (R = 0.99) between 3SAX/1RR and 3SAX/2RR for global MP (mL/min/g). The diagnostic confidence score increased significantly when the number of perfusion views was increased from 3 to 6 (1.24 ± 0.68 vs 1.54 ± 0.64, p < 0.001 with similar increase for 3SAX+3LAX/2RR (1.29 ± 0.68 vs 1.55 ± 0.65, p < 0.001) and for 6SAX/2RR (1.19 ± 0.69 vs 1.53 ± 0.63, p < 0.001). CONCLUSION: Quantitative perfusion mapping with 2RR sampling of data yields comparable perfusion values as 1RR sampling, allowing for the acquisition of additional views within the same perfusion scan. The diagnostic confidence for stress-induced ischemia increases when adding 3 additional views, short- or long axes, to the conventional 3 short-axis views. Thus, future development and clinical implementation of quantitative CMR perfusion should aim at increasing the LV coverage from the current standard using 3 short-axis views.


Assuntos
Circulação Coronária , Ventrículos do Coração , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Valor Preditivo dos Testes , Humanos , Masculino , Feminino , Imagem de Perfusão do Miocárdio/métodos , Pessoa de Meia-Idade , Idoso , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Reprodutibilidade dos Testes , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Função Ventricular Esquerda , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Frequência Cardíaca
2.
BMC Neurol ; 24(1): 111, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575854

RESUMO

BACKGROUND: Rapamycin is an inhibitor of the mechanistic target of rapamycin (mTOR) protein kinase, and preclinical data demonstrate that it is a promising candidate for a general gero- and neuroprotective treatment in humans. Results from mouse models of Alzheimer's disease have shown beneficial effects of rapamycin, including preventing or reversing cognitive deficits, reducing amyloid oligomers and tauopathies and normalizing synaptic plasticity and cerebral glucose uptake. The "Evaluating Rapamycin Treatment in Alzheimer's Disease using Positron Emission Tomography" (ERAP) trial aims to test if these results translate to humans through evaluating the change in cerebral glucose uptake following six months of rapamycin treatment in participants with early-stage Alzheimer's disease. METHODS: ERAP is a six-month-long, single-arm, open-label, phase IIa biomarker-driven study evaluating if the drug rapamycin can be repurposed to treat Alzheimer's disease. Fifteen patients will be included and treated with a weekly dose of 7 mg rapamycin for six months. The primary endpoint will be change in cerebral glucose uptake, measured using [18F]FDG positron emission tomography. Secondary endpoints include changes in cognitive measures, markers in cerebrospinal fluid as well as cerebral blood flow measured using magnetic resonance imaging. As exploratory outcomes, the study will assess change in multiple age-related pathological processes, such as periodontal inflammation, retinal degeneration, bone mineral density loss, atherosclerosis and decreased cardiac function. DISCUSSION: The ERAP study is a clinical trial using in vivo imaging biomarkers to assess the repurposing of rapamycin for the treatment of Alzheimer's disease. If successful, the study would provide a strong rationale for large-scale evaluation of mTOR-inhibitors as a potential disease-modifying treatment in Alzheimer's disease. TRIAL REGISTRATION: ClinicalTrials.gov ID NCT06022068, date of registration 2023-08-30.


Assuntos
Doença de Alzheimer , Transtornos Cognitivos , Humanos , Envelhecimento , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/tratamento farmacológico , Doença de Alzheimer/complicações , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Ensaios Clínicos Fase II como Assunto , Glucose/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Serina-Treonina Quinases TOR
3.
J Magn Reson Imaging ; 57(1): 71-82, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35726779

RESUMO

BACKGROUND: Neonates with critical congenital heart disease require early intervention. Four-dimensional (4D) flow may facilitate surgical planning and improve outcome, but accuracy and precision in neonates are unknown. PURPOSE: To 1) validate two-dimensional (2D) and 4D flow MRI in a phantom and investigate the effect of spatial and temporal resolution; 2) investigate accuracy and precision of 4D flow and internal consistency of 2D and 4D flow in neonates; and 3) compare scan time of 4D flow to multiple 2D flows. STUDY TYPE: Phantom and prospective patients. POPULATION: A total of 17 neonates with surgically corrected aortic coarctation (age 18 days [IQR 11-20]) and a three-dimensional printed neonatal aorta phantom. FIELD STRENGTH/SEQUENCE: 1.5T, 2D flow and 4D flow. ASSESSMENT: In the phantom, 2D and 4D flow volumes (ascending and descending aorta, and aortic arch vessels) with different resolutions were compared to high-resolution reference 2D flow. In neonates, 4D flow was compared to 2D flow volumes at each vessel. Internal consistency was computed as the flow volume in the ascending aorta minus the sum of flow volumes in the aortic arch vessels and descending aorta, divided by ascending aortic flow. STATISTICAL TESTS: Bland-Altman plots, Pearson correlation coefficient (r), and Student's t-tests. RESULTS: In the phantom, 2D flow differed by 0.01 ± 0.02 liter/min with 1.5 mm spatial resolution and -0.01 ± 0.02 liter/min with 0.8 mm resolution; 4D flow differed by -0.05 ± 0.02 liter/min with 2.4 mm spatial and 42 msec temporal resolution, -0.01 ± 0.02 liter/min with 1.5 mm, 42 msec resolution and -0.01 ± 0.02 liter/min with 1.5 mm, 21 msec resolution. In patients, 4D flow and 2D flow differed by -0.06 ± 0.08 liter/min. Internal consistency in patients was -11% ± 17% for 2D flow and 5% ± 13% for 4D flow. Scan time was 17.1 minutes [IQR 15.5-18.5] for 2D flow and 6.2 minutes [IQR 5.3-6.9] for 4D flow, P < 0.0001. DATA CONCLUSION: Neonatal 4D flow MRI is time efficient and can be acquired with good internal consistency without contrast agents or general anesthesia, thus potentially expanding 4D flow use to the youngest and smallest patients. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Recém-Nascido , Humanos , Adolescente , Imageamento Tridimensional/métodos , Velocidade do Fluxo Sanguíneo , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Anestesia Geral , Reprodutibilidade dos Testes
4.
J Cardiovasc Magn Reson ; 25(1): 45, 2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37620886

RESUMO

BACKGROUND: Patients with heart failure and left bundle branch block (LBBB) may receive cardiac resynchronization therapy (CRT), but current selection criteria are imprecise, and many patients have limited treatment response. Hemodynamic forces (HDF) have been suggested as a marker for CRT response. The aim of this study was therefore to investigate left ventricular (LV) HDF as a predictive marker for LV remodeling after CRT. METHODS: Patients with heart failure, EF < 35% and LBBB (n = 22) underwent CMR with 4D flow prior to CRT. LV HDF were computed in three directions using the Navier-Stokes equations, reported in median N [interquartile range], and the ratio of transverse/longitudinal HDF was calculated for systole and diastole. Transthoracic echocardiography was performed before and 6 months after CRT. Patients with end-systolic volume reduction ≥ 15% were defined as responders. RESULTS: Non-responders had smaller HDF than responders in the inferior-anterior direction in systole (0.06 [0.03] vs. 0.07 [0.03], p = 0.04), and in the apex-base direction in diastole (0.09 [0.02] vs. 0.1 [0.05], p = 0.047). Non-responders had larger diastolic HDF ratio compared to responders (0.89 vs. 0.67, p = 0.004). ROC analysis of diastolic HDF ratio for identifying CRT non-responders had AUC of 0.88 (p = 0.005) with sensitivity 57% and specificity 100% for ratio > 0.87. Intragroup comparison found higher HDF ratio in systole compared to diastole for responders (p = 0.003), but not for non-responders (p = 0.8). CONCLUSION: Hemodynamic force ratio is a potential marker for identifying patients with heart failure and LBBB who are unlikely to benefit from CRT. Larger-scale studies are required before implementation of HDF analysis into clinical practice.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Remodelação Ventricular , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Bloqueio de Ramo , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Hemodinâmica
5.
J Nucl Cardiol ; 30(5): 1935-1946, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36913172

RESUMO

BACKGROUND: The solid-state cadmium-zinc-telluride (CZT) gamma camera for myocardial perfusion single-photon emission computed tomography (MPS) has theoretical advantages compared to the conventional gamma camera technique. This includes more sensitive detectors and better energy resolution. We aimed to explore the diagnostic performance of gated MPS with a CZT gamma camera compared to a conventional gamma camera for detection of myocardial infarct (MI) and assessment of left ventricular (LV) volumes and ejection fraction (LVEF), using cardiac magnetic resonance (CMR) as the reference method. METHODS: Seventy-three patients (26% female) with known or suspected chronic coronary syndrome were examined with gated MPS using both a CZT gamma camera and a conventional gamma camera as well as with CMR. Presence and extent of MI on MPS and late gadolinium enhancement (LGE) CMR was evaluated. For LV volumes, LVEF and LV mass, gated MPS images and cine CMR images were evaluated. RESULTS: MI was found in 42 patients on CMR. The overall sensitivity, specificity, positive and negative predictive values for the CZT and the conventional gamma camera were the same (67%, 100%, 100% and 69%). For infarct size > 3% on CMR, the sensitivity was 82% for the CZT and 73% for the conventional gamma camera, respectively. LV volumes were significantly underestimated by MPS compared to CMR (P ≤ .002 for all measures). The underestimation was slightly less pronounced for the CZT compared to the conventional gamma camera (2-10 mL, P ≤ .03 for all measures). For LVEF, however, accuracy was high for both gamma cameras. CONCLUSION: Differences between a CZT and a conventional gamma camera for detection of MI and assessment of LV volumes and LVEF are small and do not appear to be clinically significant.


Assuntos
Infarto do Miocárdio , Imagem de Perfusão do Miocárdio , Humanos , Feminino , Masculino , Câmaras gama , Meios de Contraste , Imagem de Perfusão do Miocárdio/métodos , Gadolínio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Telúrio , Cádmio , Infarto do Miocárdio/diagnóstico por imagem , Perfusão
6.
J Cardiovasc Magn Reson ; 24(1): 53, 2022 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-36336693

RESUMO

BACKGROUND: The objective of the study was to investigate variability and agreement of the commonly used image processing method "n-SD from remote" and in particular for quantifying myocardial infarction by late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR). LGE-CMR in tandem with the analysis method "n-SD from remote" represents the current reference standard for infarct quantification. This analytic method utilizes regions of interest (ROIs) and defines infarct as the tissue with a set number of standard deviations (SD) above the signal intensity of remote nulled myocardium. There is no consensus on what the set number of SD is supposed to be. Little is known about how size and location of ROIs and underlying signal properties in the LGE images affect results. Furthermore, the method is frequently used elsewhere in medical imaging often without careful validation. Therefore, the usage of the "n-SD" method warrants a thorough validation. METHODS: Data from 214 patients from two multi-center cardioprotection trials were included. Infarct size from different remote ROI positions, ROI size, and number of standard deviations ("n-SD") were compared with reference core lab delineations. RESULTS: Variability in infarct size caused by varying ROI position, ROI size, and "n-SD" was 47%, 48%, and 40%, respectively. The agreement between the "n-SD from remote" method and the reference infarct size by core lab delineations was low. Optimal "n-SD" threshold computed on a slice-by-slice basis showed high variability, n = 5.3 ± 2.2. CONCLUSION: The "n-SD from remote" method is unreliable for infarct quantification due to high variability which depends on different placement and size of remote ROI, number "n-SD", and image signal properties related to the CMR-scanner and sequence used. Therefore, the "n-SD from remote" method should not be used, instead methods validated against an independent standard are recommended.


Assuntos
Gadolínio , Infarto do Miocárdio , Humanos , Meios de Contraste , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Espectroscopia de Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos
7.
J Nucl Cardiol ; 29(6): 2974-2983, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34750725

RESUMO

BACKGROUND: Evaluation of cardiac resynchronization therapy (CRT) often includes New York Heart Association (NYHA) classification, and echocardiography. However, these measures have limitations. Perfusion gradients from ventilation/perfusion single-photon emission computed tomography (V/P SPECT) are related to left-heart filling pressures and have been validated against invasive right-heart catheterization. The aim was to assess if changes in perfusion gradients are associated with improvements in heart failure (HF) symptoms after CRT, and if they correlate with currently used diagnostic methods in the follow-up of patients with HF after receiving CRT. METHODS AND RESULTS: Nineteen patients underwent V/P SPECT, echocardiography, NYHA classification, and the quality-of-life scoring system "Minnesota living with HF" (MLWHF), before and after CRT. CRT caused improvement in perfusion gradients from V/P SPECT which were associated with improvements in NYHA classification (P = .0456), whereas improvements in end-systolic volume (LVESV) from echocardiography were not. After receiving CRT, the proportion of patients who improved was lower using LVESV (n = 7/19, 37%) than perfusion gradients (n = 13/19, 68%). Neither change in perfusion gradients nor LVESV was associated with changes in MLWHF (P = 1.0, respectively). CONCLUSIONS: Measurement of perfusion gradients from V/P SPECT is a promising quantitative user-independent surrogate measure of left-sided filling pressure in the assessment of CRT response in patients with HF.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Resultado do Tratamento , Coração , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Perfusão
8.
BMC Cardiovasc Disord ; 22(1): 253, 2022 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-35668358

RESUMO

BACKGROUND: Pressure-volume (PV) loops provide comprehensive information of cardiac function, but commonly implies an invasive procedure under general anesthesia. A novel technique has made it possible to non-invasively estimate PV loops with cardiac magnetic resonance (CMR) and brachial pressure which would enable good volume estimation of often anatomically complex ventricles without the need of anesthesia in most cases. In this study we aimed to compare how hemodynamic parameters derived from PV loops in patients with Fontan circulation differ to controls. METHODS: Patients with Fontan circulation (n = 17, median age 12 years, IQR 6-15) and healthy controls (n = 17, 14 years, IQR 13-22) were examined with CMR. Short axis balanced steady-state free-precession cine images covering the entire heart were acquired. PV loops were derived from left ventricular volumes in all timeframes and brachial blood pressure from cuff sphygmomanometry. RESULTS: Fontan patients had lower stroke work, ventricular mechanical efficiency and external power compared to controls. Fontan patients with dominant right ventricle had higher potential energy indexed to body surface area but lower contractility (Ees) compared to controls. Fontan patients had higher arterial elastance (Ea) and Ea/Ees ratio than controls. Contractility showed no correlation with ejection fraction (EF) in Fontan patients irrespective of ventricular morphology. No difference was seen in energy per ejected volume between Fontan patients and controls. CONCLUSIONS: This non-invasive PV-loop method could be used in future studies to show the potential prognostic value of these measures and if changes in ventricular function over time can be detected earlier by this method compared to changes in ventricular volumes and EF. In contrast to patients with acquired heart failure, Fontan patients had similar energy per ejected volume as controls which suggests similar ventricular oxygen consumption to deliver the same volume in Fontan patients as in controls.


Assuntos
Técnica de Fontan , Artéria Braquial , Criança , Técnica de Fontan/efeitos adversos , Ventrículos do Coração , Humanos , Volume Sistólico , Função Ventricular Esquerda/fisiologia
9.
J Cardiovasc Magn Reson ; 23(1): 123, 2021 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-34706735

RESUMO

BACKGROUND: Increased pulmonary blood volume (PBV) is a measure of congestion and is associated with an increased risk of cardiovascular events. PBV can be quantified using cardiovascular magnetic resonance (CMR) imaging as the product of cardiac output and pulmonary transit time (PTT), the latter measured from the contrast time-intensity curves in the right and left side of the heart from first-pass perfusion (FPP). Several methods of estimating PTT exist, including pulmonary transit beats (PTB), peak-to-peak, and center of gravity (CoG). The aim of this study was to determine the accuracy and precision for these methods of quantifying the PBV, taking the left atrium volume (LAV) into consideration. METHODS: Fifty-eight participants (64 ± 11 years, 24 women) underwent 1.5 T CMR. PTT was quantified from (1) a basal left ventricular short-axis image (FPP), and (2) the reference method with a separate contrast administration using an image intersecting the pulmonary artery (PA) and the LA (CoG(PA-LA)). RESULTS: Compared to the reference, PBV for (a) PTB(FPP) was 14 ± 17% larger, (b) peak-peak(FPP) was 17 ± 16% larger, and (c) CoG(FPP) was 18 ± 10% larger. Subtraction of the LAV (available for n = 50) decreased overall differences to - 1 ± 19%, 2 ± 18%, and 3 ± 12% for PTB(FPP), peak-peak(FPP), and CoG(FPP), respectively. Lowest interobserver variability was seen for CoG(FPP) (- 2 ± 7%). CONCLUSIONS: CoG(PA-LA) and FPP methods measured the same PBV only when adjusting for the LAV, since FPP inherently quantifies a volume consisting of PBV + LAV. CoG(FPP) had the best precision and lowest interobserver variability among the FPP methods of measuring PBV.


Assuntos
Volume Sanguíneo , Átrios do Coração , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
10.
J Nucl Cardiol ; 28(6): 2910-2922, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-32451797

RESUMO

INTRODUCTION: We investigated if uptake pattern on myocardial perfusion SPECT (MPS) in patients with left bundle branch block (LBBB) is related to myocardial fibrosis, myocardial wall motion, and electrocardiography (ECG) characteristics. METHODS: Twenty-three patients (9 women) with LBBB, examined with MPS and cardiac magnetic resonance (CMR), were included. Tracer uptake on MPS was classified by visual interpretation as typical LBBB pattern (Defect+, n = 13) or not (Defect-, n = 10) and quantitatively. CMR images were evaluated for wall thickness and for myocardial wall motion both by visual assessment and by regional myocardial radial strain from feature tracking, and for presence and location of myocardial fibrosis. ECGs were analyzed regarding QRS duration and the presence of strict criteria for LBBB. RESULTS: Wall thickness was slightly lower in the septum compared to the lateral wall in Defect+ patients (5.6 ± 1.1 vs 6.0 ± 1.3 mm, P = 0.03) but not in Defect- patients (5.6 ± 1.0 vs 5.6 ± 0.9 mm, P = 0.84). Defect+ patients showed a larger proportion of dyskinetic segments in the septum and hyperkinetic segments in the lateral wall compared to Defect- patients (P = 0.006 and P = 0.004, respectively). Decreased myocardial radial strain was associated with decreased tracer uptake by MPS (R = 0.37, P < 0.001). Areas of fibrosis did not match areas with uptake defect on MPS. No differences in ECG variables were seen. CONCLUSION: The heterogeneous regional tracer uptake in some patients with LBBB is related to underlying regional myocardial dyskinesia, wall thickening, and wall thickness rather than stress-induced ischemia, myocardial fibrosis, or specific ECG characteristics.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Coração/fisiopatologia , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Bloqueio de Ramo/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Estudos Retrospectivos
11.
J Nucl Cardiol ; 28(4): 1664-1672, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-31705424

RESUMO

BACKGROUND: Many patients undergo percutaneous coronary intervention (PCI) without the use of non-invasive stress testing prior to treatment. The aim of this study was to determine the potential added value of guiding revascularization by quantitative assessment of myocardial perfusion prior to intervention. METHODS AND RESULTS: Thirty-three patients (10 females) with suspected or established CAD who had been referred for a clinical coronary angiography (CA) with possibility for PCI were included. Adenosine stress and rest 13N-NH3 PET, cardiac magnetic resonance (CMR), and cardiopulmonary exercise test were performed 4 ± 3 weeks before and 5 ± 1 months after CA. The angiographer was blinded to the PET and CMR results. Myocardial flow reserve (MFR) < 2.0 by PET was considered abnormal. A PCI was performed in 19/33 patients. In 41% (11/27) of the revascularized vessel territories, a normal regional MFR was found prior to the PCI and no improvement in MFR was found at follow-up (P = 0.9). However, vessel territories with regional MFR < 2.0 at baseline improved significantly after PCI (P = 0.003). Of the 14 patients not undergoing PCI, four had MFR < 2.0 in one or more coronary territories. CONCLUSION: Assessment of quantitative myocardial perfusion prior to revascularization could lead to more appropriate use of CA when managing patients with stable CAD.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Tomografia por Emissão de Pósitrons , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Teste de Esforço , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos , Resultado do Tratamento
12.
BMC Cardiovasc Disord ; 21(1): 519, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34702172

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) restores ventricular synchrony and induces left ventricular (LV) reverse remodeling in patients with heart failure (HF) and dyssynchrony. However, 30% of treated patients are non-responders despite all efforts. Cardiac magnetic resonance imaging (CMR) can be used to quantify regional contributions to stroke volume (SV) as potential CRT predictors. The aim of this study was to determine if LV longitudinal (SVlong%), lateral (SVlat%), and septal (SVsept%) contributions to SV differ from healthy controls and investigate if these parameters can predict CRT response. METHODS: Sixty-five patients (19 women, 67 ± 9 years) with symptomatic HF (LVEF ≤ 35%) and broadened QRS (≥ 120 ms) underwent CMR. SVlong% was calculated as the volume encompassed by the atrioventricular plane displacement (AVPD) from end diastole (ED) to end systole (ES) divided by total SV. SVlat%, and SVsept% were calculated as the volume encompassed by radial contraction from ED to ES. Twenty age- and sex-matched healthy volunteers were used as controls. The regional measures were compared to outcome response defined as ≥ 15% decrease in echocardiographic LV end-systolic volume (LVESV) from pre- to 6-months post CRT (delta, Δ). RESULTS: AVPD and SVlong% were lower in patients compared to controls (8.3 ± 3.2 mm vs 15.3 ± 1.6 mm, P < 0.001; and 53 ± 18% vs 64 ± 8%, P < 0.01). SVsept% was lower (0 ± 15% vs 10 ± 4%, P < 0.01) with a higher SVlat% in the patient group (42 ± 16% vs 29 ± 7%, P < 0.01). There were no differences between responders and non-responders in neither SVlong% (P = 0.87), SVlat% (P = 0.09), nor SVsept% (P = 0.65). In patients with septal net motion towards the right ventricle (n = 28) ΔLVESV was - 18 ± 22% and with septal net motion towards the LV (n = 37) ΔLVESV was - 19 ± 23% (P = 0.96). CONCLUSIONS: Longitudinal function, expressed as AVPD and longitudinal contribution to SV, is decreased in patients with HF scheduled for CRT. A larger lateral contribution to SV compensates for the abnormal septal systolic net movement. However, LV reverse remodeling could not be predicted by these regional contributors to SV.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Estudos de Casos e Controles , Ecocardiografia , Feminino , Coração/fisiologia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Remodelação Ventricular
13.
Scand Cardiovasc J ; 55(3): 145-152, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33461362

RESUMO

OBJECTIVES: To evaluate the diagnostic yield of the ECG criteria for ST-elevation myocardial infarction in a large cohort of emergency department chest pain patients, and to determine whether extended ECG criteria or reciprocal ST depression can improve accuracy. Design: Observational, register-based diagnostic study on the accuracy of ECG criteria for ST-elevation myocardial infarction. Between Jan 2010 and Dec 2014 all patients aged ≥30 years with chest pain who had an ECG recorded within 4 h at two emergency departments in Sweden were included. Exclusion criteria were: ECG with poor technical quality; QRS duration ≥120 ms; ECG signs of left ventricular hypertrophy; or previous coronary artery bypass surgery. Conventional and extended ECG criteria were applied to all patients. The main outcome was acute myocardial infarction (AMI) and an occluded/near-occluded coronary artery at angiography. Results: Finally, 19932 patients were included. Conventional ECG criteria for ST elevation myocardial infarction were fulfilled in 502 patients, and extended criteria in 1249 patients. Sensitivity for conventional ECG criteria in diagnosing AMI with coronary occlusion/near-occlusion was 17%, specificity 98% and positive predictive value 12%. Corresponding data for extended ECG criteria were 30%, 94% and 8%. When reciprocal ST depression was added to the criteria, the positive predictive value rose to 24% for the conventional and 23% for the extended criteria. Conclusions: In unselected chest pain patients at the emergency department, the diagnostic yield of both conventional and extended ECG criteria for ST-elevation myocardial infarction is low. The PPV can be increased by also considering reciprocal ST depression.


Assuntos
Dor no Peito , Infarto do Miocárdio com Supradesnível do Segmento ST , Adulto , Dor no Peito/etiologia , Estudos de Coortes , Serviço Hospitalar de Emergência , Humanos , Valor Preditivo dos Testes , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico
14.
Pediatr Cardiol ; 42(3): 492-500, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33515326

RESUMO

An ECG risk-score has been described that predicts high risk of subsequent cardiac arrest in young patients with hypertrophic cardiomyopathy (HCM). Myocardial fibrosis measured by cardiac magnetic resonance (CMR) late gadolinium enhancement (LGE) also affects prognosis. We assessed whether an ECG risk-score could be used as an indicator of myocardial fibrosis or perfusion deficit on CMR in HCM. In total 42 individuals (7-31 years); 26 HCM patients, seven genotype-positive, phenotype-negative individuals at risk of HCM (first-degree relatives) and nine healthy volunteers, underwent CMR to identify, and grade extent of, myocardial fibrosis and perfusion defect. 12-lead ECG was used for calculating the ECG risk-score (grading 0-14p). High-risk ECG (risk-score > 5p) occurred only in the HCM group (9/26), and the proportion was significantly higher vs mutation carriers combined with healthy volunteers (0/16, p = 0.008). Extent of LGE correlated to the ECG-score (R2 = 0.47, p = 0.001) in sarcomeric mutations. In low-risk ECG-score patients (0-2p), median percent of myocardium showing LGE (LGE%LVM) were: 0% [interquartile range, IQR, 0-0%], in intermediate-risk (3-5p): 5.4% [IQR 0-13.5%] and in high-risk (6-14p): 10.9% [IQR 4.2-12.3%]. ECG-score > 2p had a sensitivity and specificity of 79% and 84% to detect positive LGE on CMR and 77% vs. 75% to detect perfusion defects in sarcomeric mutations carriers. In patients with myocardial fibrosis as identified by LGE, median ECG risk-score was 8p [range 3-10p]. In conclusions, ECG risk-score > 2 p could be used as a cut-off for screening of myocardial fibrosis. Thus ECG risk-score is an inexpensive complementary tool in risk stratification of HCM in the young.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Eletrocardiografia/métodos , Fibrose/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Adolescente , Adulto , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/patologia , Criança , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Coração/diagnóstico por imagem , Humanos , Masculino , Mutação , Fenótipo , Prognóstico , Fatores de Risco , Sarcômeros/genética , Sarcômeros/patologia , Sensibilidade e Especificidade , Adulto Jovem
15.
Am J Physiol Heart Circ Physiol ; 318(2): H345-H353, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31886724

RESUMO

Timing and indication for pulmonary valve replacement (PVR) in patients with repaired Tetralogy of Fallot (rToF) and pulmonary regurgitation (PR) are uncertain. To improve understanding of pumping mechanics, we investigated atrioventricular coupling before and after surgical PVR. Cardiovascular magnetic resonance was performed in patients (n = 12) with rToF and PR > 35% before and after PVR and in healthy controls (n = 15). Atrioventricular plane displacement (AVPD), global longitudinal peak systolic strain (GLS), atrial and ventricular volumes, and caval blood flows were analyzed. Right ventricular (RV) AVPD and RV free wall GLS were lower in patients before PVR compared with controls (P < 0.0001; P < 0.01) and decreased after PVR (P < 0.0001 for both). Left ventricular AVPD was lower in patients before PVR compared with controls (P < 0.05) and decreased after PVR (P < 0.01). Left ventricular GLS did not differ between patients and controls (P > 0.05). Right atrial reservoir volume and RV stroke volume generated by AVPD correlated in controls (r = 0.93; P < 0.0001) and patients before PVR (r = 0.88; P < 0.001) but not after PVR. In conclusion, there is a clear atrioventricular coupling in patients before PVR that is lost after PVR, possibly because of loss of pericardial integrity. Impaired atrioventricular coupling complicates assessment of ventricular function after surgery using measurements of longitudinal function. Changes in atrioventricular coupling seen in patients with rToF may be energetically unfavorable, and long-term effects of surgery on atrioventricular coupling is therefore of interest. Also, AVPD and GLS cannot be used interchangeably to assess longitudinal function in rToF.NEW & NOTEWORTHY There is a clear atrioventricular coupling in patients with Tetralogy of Fallot (ToF) and pulmonary regurgitation before surgical pulmonary valve replacement (PVR) that is lost after operation, possibly because of loss of pericardial integrity. The impaired atrioventricular coupling complicates assessment of ventricular function after surgery when using measurements of longitudinal function. Left ventricular atrioventricular plane displacement (AVPD) found differences between patients and controls and changes after PVR that longitudinal strain could not detect. This indicates that AVPD and strain cannot be used interchangeably to assess longitudinal function in repaired ToF.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar/cirurgia , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Teste de Esforço , Feminino , Testes de Função Cardíaca , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valva Pulmonar/diagnóstico por imagem , Volume Sistólico , Tetralogia de Fallot/diagnóstico por imagem , Resultado do Tratamento
16.
Magn Reson Med ; 84(4): 2231-2245, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32270549

RESUMO

PURPOSE: Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. METHODS: An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. RESULTS: Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. CONCLUSIONS: Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.


Assuntos
Hidrodinâmica , Imageamento Tridimensional , Velocidade do Fluxo Sanguíneo , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas
17.
Magn Reson Med ; 83(2): 662-672, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31418490

RESUMO

PURPOSE: To verify MR measurements of myocardial extracellular volume fraction (ECV) based on clinically applicable T1-mapping sequences against ECV measurements by radioisotope tracer in pigs and to relate the results to those obtained in volunteers. METHODS: Between May 2016 and March 2017, 8 volunteers (25 ± 4 years, 3 female) and 8 pigs (4 female) underwent ECV assessment with SASHA, MOLLI5(3b)3, MOLLI5(3s)3, and MOLLI5s(3s)3s. Myocardial ECV was measured independently in pigs using a radioisotope tracer method. RESULTS: In pigs, ECV in normal myocardium was not different between radioisotope (average ± standard deviation; 19 ± 2%) and SASHA (21 ± 2%; P = 0.086). ECV was higher by MOLLI5(3b)3 (26 ± 2%), MOLLI5(3s)3 (25 ± 2%), and MOLLI5s(3s)3s (25 ± 2%) compared with SASHA or radioisotope (P ≤ 0.001 for all). ECV in volunteers was higher by MOLLI5(3b)3 (26 ± 3%) and MOLLI5(3s)3 (26 ± 3%) than by SASHA (22 ± 3%; P = 0.022 and P = 0.033). No difference was found between MOLLI5s(3s)3s (25 ± 3%) and SASHA (P = 0.225). Native T1 of blood and myocardium as well as postcontrast T1 of myocardium was consistently lower using MOLLI compared with SASHA. ECV increased over time as measured by MOLLI5(3b)3 and MOLLI5(3s)3 for pigs (0.08% and 0.07%/min; P = 0.004 and P = 0.013) and by MOLLI5s(3s)3s for volunteers (0.07%/min; P = 0.032) but did not increase as measured by SASHA. CONCLUSION: Clinically available MOLLI and SASHA techniques can be used to accurately estimate ECV in normal myocardium where MOLLI-sequences show minor overestimation driven by underestimation of postcontrast T1 when compared with SASHA. The timing of imaging after contrast administration affected the measurement of ECV using some variants of the MOLLI sequence.


Assuntos
Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Miocárdio/patologia , Adulto , Algoritmos , Animais , Meios de Contraste , Feminino , Frequência Cardíaca , Hematócrito , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Suínos , Adulto Jovem
18.
J Magn Reson Imaging ; 51(5): 1412-1421, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31654470

RESUMO

BACKGROUND: In mitral valve dysfunction, noninvasive measurement of transmitral blood flow is an important clinical examination. Flow imaging of the mitral valve, however, is challenging, since it moves in and out of the image plane during the cardiac cycle. PURPOSE: To more accurately measure mitral flow, a slice-following MRI phase contrast sequence is proposed. This study aimed to implement such a sequence, validate its slice-following functionality in a phantom and healthy subjects, and test its feasibility in patients with mitral valve dysfunction. STUDY TYPE: Prospective. PHANTOM AND SUBJECTS: The slice-following functionality was validated in a cone-shaped phantom by measuring the depicted slice radius. Sixteen healthy subjects and 10 mitral valve dysfunction patients were enrolled at two sites. FIELD STRENGTH/SEQUENCE: 1.5T and 3T gradient echo cine phase contrast. ASSESSMENT: A single breath-hold retrospectively gated sequence using offline feature-tracking of the mitral valve was developed. Valve displacements were measured and imported to the scanner, allowing the slice position to change dynamically based on the cardiac phase. Mitral valve imaging was performed with slice-following and static imaging planes. Validation was performed by comparing mitral stroke volume with planimetric and aortic stroke volume. STATISTICAL TESTS: Measurements were compared using linear regression, Pearson's R, parametric paired t-tests, Bland-Altman analysis, and intraclass correlation coefficient (ICC). RESULTS: Phantom experiments confirmed accurate slice displacements. Slice-following was feasible in all subjects, yielding physiologically accurate mitral flow patterns. In healthy subjects, mitral and aortic stroke volumes agreed, with ICC = 0.72 and 0.90 for static and slice-following planes; with bias ±1 SDs 23.2 ± 13.2 mls and 8.4 ± 10.8 mls, respectively. Agreement with planimetry was stronger, with ICC = 0.84 and 0.96; bias ±1 SDs 13.7 ± 13.7 mls and -2.0 ± 8.8 mls for static and slice-following planes, respectively. DATA CONCLUSION: Slice-following outperformed the conventional sequence and improved the accuracy of transmitral flow, which is important for assessment of diastolic function and mitral regurgitation. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:1412-1421.


Assuntos
Imageamento por Ressonância Magnética , Insuficiência da Valva Mitral , Velocidade do Fluxo Sanguíneo , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
19.
J Nucl Cardiol ; 27(6): 2351-2359, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-30535919

RESUMO

BACKGROUND: To relate findings of qualitative evaluation of first-pass perfusion-CMR and anatomical evaluation on coronary angiography (CA) to the reference standard of quantitative perfusion, cardiac PET, in patients with suspected or known stable coronary artery disease (CAD). METHODS AND RESULTS: Forty-one patients referred for CA due to suspected stable CAD, prospectively performed adenosine stress/rest first-pass perfusion-CMR as well as 13N-NH3 PET on the same day, 4 ± 3 weeks before CA. Angiographers were blinded to PET and CMR results. Regional myocardial flow reserve (MFR) < 2.0 on PET was considered pathological. Vessel territories with stress-induced ischemia by CMR or vessels with stenosis needing revascularization had a significantly lower MFR compared to those with no regional stress-induced ischemia or vessels not needing revascularization (P < 0.001). In 4 of 123 vessel territories with stress-induced ischemia by CMR, PET showed a normal MFR. In addition, 12 of 123 vessels that underwent intervention showed normal MFR assessed by PET. CONCLUSION: The limited performance of qualitative assessment of presence of stable CAD with CMR and CA, when related to quantitative 13N-NH3 cardiac PET, shows the need for fully quantitative assessment of myocardial perfusion and the use of invasive flow reserve measurements for CA, to confirm the need of elective revascularization.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Adenosina/química , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Circulação Coronária , Estenose Coronária/fisiopatologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Revascularização Miocárdica , Miocárdio/patologia , Variações Dependentes do Observador , Estudos Prospectivos , Padrões de Referência , Tomografia Computadorizada por Raios X
20.
BMC Cardiovasc Disord ; 20(1): 309, 2020 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-32600336

RESUMO

BACKGROUND: Atrioventricular plane displacement (AVPD) reflects longitudinal left ventricular (LV) systolic function, and wall thickening (WT) regional radial LV function. The temporal evolution of these measures after STEMI with CMR has not been evaluated. We aimed to investigate how AVPD and WT are affected globally and regionally from the sub-acute to the chronic phase after ST-elevation myocardial infarction (STEMI). METHODS: Healthy volunteers without cardiovascular disease and medication (controls, n = 20) and patients from the CHILL-MI study ( NCT01379261 ) prospectively underwent magnetic resonance imaging (MRI) 2-6 days and 6 months after STEMI (n = 77). CHILL-MI randomized STEMI-patients to cooling therapy initiated before reperfusion or standard of care. AVPD was measured at six points in three long axis cine images and wall thickening in short axis cine images. Infarction was quantified using late gadolinium enhancement (LGE) and used to define infarct and remote segments. RESULTS: There were no difference in AVPD either at acute or chronic phase (p = 0.90 and p = 0.40) or WT (p = 0.85 and p = 0.99) between patients randomized to cooling therapy and standard of care. Therefore, the results are presented for the pooled cohort. Global AVPD was decreased in both the sub-acute (12 ± 2 mm, p < 0.001) and the chronic phase (13 ± 2 mm, p < 0.001) compared to controls (15 ± 2 mm) with a partial recovery of AVPD (p < 0.001) in the chronic phase. Patients with left anterior descending (LAD) and right coronary artery (RCA) infarcts had decreased AVPD in the chronic phase in both infarcted and remote segments. Mean WT was decreased in patients with LAD infarction both in the sub-acute and the chronic phase in both infarcted and remote segments. The decrease in WT in patients with RCA and left circumflex (LCx) infarcts was more affected in the infarcted segments, especially in the chronic phase. CONCLUSION: AVPD was a global rather than regional marker of cardiac function in this STEMI study and this may explain the prognostic importance of local measurements of mitral annular plane systolic excursion (MAPSE). The decrease in WT in remote myocardium even in the chronic phase needs to be taken into consideration when combining functional measurements with infarct quantification for diagnosis of post-ischemic stunning and hibernation.


Assuntos
Hipotermia Induzida , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Função Ventricular Esquerda , Idoso , Feminino , Humanos , Hipotermia Induzida/efeitos adversos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA