Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 10: 1213817, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37928765

RESUMO

Symptomatic severe aortic stenosis (AS) in patients with intermediate-to-high surgical risk is currently being treated with transcatheter aortic valve replacement (TAVR). We present a case of a TAVR in a severe calcific AS with porcelain aorta and 'gothic' aortic arch. Pre-operative thoraco-abdominal computed tomography angiography showed also severe calcification at the sinotubular junction with protruding huge calcified nodules extending in ascending aorta and multiple calcific stenosis of both iliac-femoral vessels, severely tortuous. The choice of the interventional access was not easy and the high risk of an acute intra-procedural brain event guided the procedural planning. To our knowledge, this is the first case of TAVR with complete cerebral protection with Triguard system device and 'snaring-assisted' valve advancement.

2.
Front Cardiovasc Med ; 10: 1195486, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37795479

RESUMO

Transcatheter aortic valve replacement (TAVR) is a treatment of choice in patients with symptomatic severe aortic valve stenosis (AS) and intermediate-to-high surgical risk. The presence of a small aortic annulus (SAA) has been associated with a higher incidence of prosthesis-patient mismatch (PPM) when surgical aortic valve replacement (sAVR) is performed. TAVR might be a treatment option offering better hemodynamics with a lower incidence of PPM. When a severe AS with a SAA is treated, TAVR-related risk as the coronary obstruction and the annulus rupture, must be also prevented. We present a case of a TAVR in a very small aortic annulus; to our knowledge, this is the smallest native aortic annulus treated percutaneously in a tricuspid stenotic aortic valve with a Self-Expanding Transcatheter Heart Valve (THV) Acurate Neo 2.

3.
J Cardiothorac Surg ; 18(1): 231, 2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37443033

RESUMO

Symptomatic aortic valve stenosis (AS) and abdominal aortic aneurysm (AAA) are critical clinical conditions, increasingly more prevalent with aging of the population. Calcific aortic stenosis is the most common structural cardiac disease in the elderly population, and medical management of severe aortic stenosis of the elderly population is associated with poor outcomes as compared to surgical treatment. Transcatheter aortic valve replacement (TAVR) is a treatment of choice in inoperable, often elderly, patients with symptomatic severe AS and in intermediate-to-high surgical risk patients. It is not yet clarified the incidence of AAA and its impact on procedural and clinical outcomes among patients undergoing TAVR. It is known that after AS resolution with aortic valve replacement or TAVR there is an increase in blood pressure that increases the risk of dissection or abdominal aortic aneurysm rupture if AAA repair is delayed. The purpose of this report is to describe the anatomical details and technical and procedural considerations when proposing totally endovascular strategies dedicated to the treatment of patients with AS and AAA.


Assuntos
Aneurisma da Aorta Abdominal , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Humanos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Valva Aórtica/cirurgia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/cirurgia , Fatores de Risco
4.
J Clin Med ; 11(4)2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-35207232

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective treatment option for patients with severe, symptomatic AS, regardless of the transcatheter heart valve (THV) implanted. Prior studies demonstrated a higher device success with lower paravalvular leak (PVL) using the balloon-expandable (BE) Sapien/XT THV vs. a self-expanding (SE) THV. However, few data are available on the performance of a novel BE THV. PURPOSE: to compare early clinical performance and safety of the newly available BE Myval THV (Myval, Meril Life Sciences Pvt. Ltd., India) vs. the commonly used SE (Evolut R, Medtronic) THV. METHODS:  A single-center, retrospective cohort analysis was performed with 166 consecutive patients undergoing TAVR from March 2019 to March 2021 for severe symptomatic AS treated with either the novel BE Myval or the SE Evolut R (ER) bioprosthesis. The primary endpoint was device success at day 30 according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included 30-day all-cause mortality, cardiovascular mortality, more than mild PVL, permanent pacemaker implantation (PPI) rates and a composite of all-cause mortality and disabling stroke at 6 months. RESULTS:  Among the 166 included patients, 108 patients received the SE ER THV and 58 patients were treated with the BE Myval THV. At baseline, the two groups showed comparable demographic characteristics. The primary composite endpoint of early device success occurred in 55 patients (94.8%) in the BE Myval group and in 90 patients (83.3%) in the SE ER group (OR 3.667, 95% CI 1.094-12.14; p = 0.048). At day 30, the BE Myval THV group exhibited a significantly lower incidence of more than mild PVL (BE Myval 3.45% vs. SE ER 14.8%, OR 0.2, 95% CI 0.05-0.8; p = 0.0338), along with a lower rate of PPI (BE Myval 11% vs. SE ER 24.2%, OR 0.38, 95% CI 0.15-0.99; p = 0.0535). At the 6-month follow-up, the incidence of all-cause mortality and disabling stroke did not significantly differ between the two groups, while the incidence of PPI (BE Myval 11% vs. SE ER 27.5%, OR 0.32, CI 95% 0.1273-0.8; p = 0.02) and ≥moderate PVL (BE Myval 6.9% vs. SE ER 19.8%, OR 0.31, 95% CI 0.1-0.94; p = 0.0396) was significantly lower in the BE Myval group. CONCLUSIONS: In patients with severe symptomatic AS undergoing TAVR, the novel Myval BE THV provided a comparable performance to the well-known ER SE THV, and it was associated with a lower rate of PPI and ≥moderate PVL within 30 days and 6 months after the procedure. Randomized, head-to-head comparison trials are needed to confirm our results.

5.
ESC Heart Fail ; 8(1): 167-170, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33161652

RESUMO

We describe the case of a 58-year-old man presenting with myocardial infarction complicated by cardiogenic shock, treated with Impella CP which was escalated to an axillary 5.0 due to lack of cardiac recovery. Weaning from Impella 5.0 failed, and the patient was evaluated for heart transplantation (HTx) or left ventricular assist device (LVAD). HTx was excluded because of a rectal adenocarcinoma. The patient underwent colorectal surgery while on Impella. Perioperative course was uneventful. After 61 days of Impella, when the LVAD implantation was scheduled, the patient died due to K. pneumoniae infection.


Assuntos
Transplante de Coração , Coração Auxiliar , Infarto do Miocárdio , Humanos , Masculino , Pessoa de Meia-Idade , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
6.
Cardiovasc Revasc Med ; 28S: 81-84, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33674218

RESUMO

None of the commercially available self-expanding (SE)-trans-catheter heart valve (THVs) used for trans-catheter aortic valve replacement (TAVR) has a deflectable delivery system. This aspect can represent a shortcoming, especially in some anatomical scenario where THV advancement is challenging. The use of a snare catheter (SC), applying an external traction force, can increase THV trackability. We describe three different TAVR cases, in which a SE-THV was the only available option and where the THV delivery system advancement in the aortic arch was not feasible, if not with the combined use of a SC.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Cardiovasc Revasc Med ; 28S: 98-101, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33250405

RESUMO

Trans-catheter valve-in-valve (ViV) is a treatment option for patients affected by bioprosthetic heart valve (BHV) failure. Both aortic and mitral ViV procedures present several challenges compared to native valve replacement. To date, no data concerning the balloon-expandable MyVal (Meril, Vapi, India) trans-catheter heart valve (THV) use in ViV procedure have been provided. In this case series, we described for the first time its use in five different BHV failures.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Catéteres , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
8.
Stroke ; 39(8): 2380-1, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18535277

RESUMO

BACKGROUND AND PURPOSE: Right to left shunt is involved in conditions in which postural changes may be pathogenically relevant. The aim of this work was to assess the frequency of posturally dependent right to left shunt. METHODS: In 109 consecutive right to left shunt-positive subjects (male/female=40/69, age 43+/-12 years), we assessed with contrast-enhanced transcranial Doppler the bubble load during normal breathing and after the Valsalva maneuver in both standing and recumbent position randomizing the order of testing. RESULTS: During normal breathing, the average bubble count was 11+/-20 in the recumbent and 26+/-60 in the standing position. After the Valsalva maneuver, it was 40+/-38 and 42+/-37, respectively. The increase of bubble load in standing position occurred in 42% of patients and was independent of the order of testing. CONCLUSIONS: The amount of permanent right to left shunt is posture-dependent in 40% of patients. Testing in the sitting position may thus be warranted in doubtful or inconclusive results obtained with the subject in the horizontal position.


Assuntos
Lateralidade Funcional , Postura , Acidente Vascular Cerebral/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Adulto , Feminino , Humanos , Ataque Isquêmico Transitório/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Enxaqueca com Aura/diagnóstico por imagem , Estudos Prospectivos , Mecânica Respiratória , Manobra de Valsalva
10.
Int J Cardiovasc Imaging ; 33(11): 1655-1662, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28550589

RESUMO

To assess feasibility, efficacy and safety of carbon dioxide (CO2) digital subtraction angiography (DSA) to guide endovascular aneurysm repair (EVAR) in a cohort of patients with chronic kidney disease (CKD). After Ethical Committee approval, the records of 13 patients (all male, mean age 74.6 ± 8.0 years) with CKD, who underwent EVAR to exclude an abdominal aortic aneurysm (AAA) under CO2 angiography guidance, were reviewed. The AAA to be excluded had a mean diameter of 52.0 ± 8.0 mm. CO2 angiography was performed by automatic (n = 7) or hand (n = 6) injection. The endograft was correctly placed and the AAA was excluded in all cases, without any surgical conversions. Two patients (15.4%) had an endoleak: one type-Ia, detected by CO2-DSA and effectively treated with prosthesis dilatation; one type-III, detected by CO2-DSA, confirmed using 10 ml of ICM, and conservatively managed. In one patient, CO2 angiograms were considered of too low quality for guiding the procedure and 200 ml of ICM were administered. Overall, 11 patients (84.6%) underwent a successful EVAR under the guidance of the sole CO2 angiography. No patients suffered from major complications, including those typically CO2-related. Two patients suffered from abdominal pain during the procedure secondary to a transient splanchnic perfusion's reduction due to CO2, and one patient had a worsening of renal function probably caused by a cholesterol embolization during the procedure. In patients with CKD, EVAR under CO2 angiography guidance is feasible, effective, and safe.


Assuntos
Angiografia Digital/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/terapia , Implante de Prótese Vascular , Dióxido de Carbono/administração & dosagem , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares , Radiografia Intervencionista/métodos , Insuficiência Renal Crônica/complicações , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital/efeitos adversos , Aneurisma da Aorta Abdominal/complicações , Implante de Prótese Vascular/efeitos adversos , Dióxido de Carbono/efeitos adversos , Meios de Contraste/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Humanos , Masculino , Valor Preditivo dos Testes , Radiografia Intervencionista/efeitos adversos , Insuficiência Renal Crônica/diagnóstico , Estudos Retrospectivos , Resultado do Tratamento
11.
Stroke ; 37(2): 430-4, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16373630

RESUMO

BACKGROUND AND PURPOSE: Transcatheter closure of patent foramen ovale (PFO) has been reported to improve migraine in patients with cerebrovascular disorders in noncontrolled studies. The aim of the study was to compare the course of migraine assessed prospectively over a 12-month period in symptomatic (for cerebrovascular disease) and asymptomatic patients undergoing PFO closure and in patients with PFO treated medically. METHODS: Twenty-three stroke symptomatic (SS; 39+/-10 years of age; males/females [M/F] 5/18) and 27 stroke asymptomatic (SA; 40+/-12 years of age; M/F 5/22) patients with migraine underwent PFO closure. Twenty-seven patients with migraine and PFO (controls [CTRLS]; 36+/-11 years of age; M/F 4/23) were followed up medically. Migraine severity was assessed at baseline with a scale that takes into account the frequency, duration, and intensity of the attacks and the occurrence of aura (score range 0 to 10). Six months later, the patients were given a structured diary to annotate monthly with the same scale the characteristics of the attacks for the next 6 months. By the end of 1 year, the migraine score was averaged for the last 6 months. RESULTS: Baseline severity of migraine did not differ between groups (6.3 to 6.1 and 6.7 in SS, SA, and CTRLS groups, respectively). At the 1-year assessment, the overall migraine score had significantly improved by 3.7 and 2.8 points in SS and SA, respectively (P<0.001 on repeated-measure ANOVA), whereas it had nonsignificantly worsened by 0.1 points in CTRLS. Multiple linear regression analysis showed that the improvement in SS and SA was independent of migraine type, age, and cerebrovascular risk factors. Twenty-one of 21 patients with migraine with aura in the CTRLS group still had aura at the end of follow-up, whereas only 3 of 14 among SA and 4 of 19 among SS continued to have migraine preceded by aura (P<0.0001 on Fisher exact test). CONCLUSIONS: Compared with medical treatment, closure of PFO brings about a significant overall improvement in migraine. This seems to occur irrespective of migraine type and of previous cerebrovascular disease. In addition to the overall improvement, in migraine with aura, the occurrence of aura is dramatically reduced.


Assuntos
Cateterismo Cardíaco , Átrios do Coração/patologia , Comunicação Interatrial/cirurgia , Septos Cardíacos/patologia , Transtornos de Enxaqueca/etiologia , Transtornos de Enxaqueca/terapia , Adulto , Análise de Variância , Estudos de Casos e Controles , Feminino , Comunicação Interatrial/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/patologia , Complicações Pós-Operatórias/etiologia , Análise de Regressão , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
13.
Cardiovasc Revasc Med ; 17(1): 63-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26797428

RESUMO

The completely absorbable stents represent one of the latest innovations in the field of interventional cardiology, prospecting the possibility of "vascular repair". In the published trials (ABSORB Cohort A and B, ABSORB EXTEND, and ABSORB II, III and IV) chronic total occlusions (CTOs) were considered an exclusion criteria. More recently the CTO-ABSORB pilot study demonstrated the safety and feasibility of bioresorbable vascular scaffold (BVS) use in case of CTO recanalization. We present the first case, to our knowledge, of in-stent occlusion successfully treated with an everolimus-eluting BVS and discuss its potential advantages in such kind of lesions.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/terapia , Ultrassonografia de Intervenção/métodos , Doença Crônica , Angiografia Coronária , Everolimo/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Artéria Radial/diagnóstico por imagem , Resultado do Tratamento
14.
Eur J Cardiothorac Surg ; 50(6): 1139-1148, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27406375

RESUMO

OBJECTIVES: The aim of this multicentre study is to report the clinical experiences of all patients undergoing transcatheter aortic valve implantation (TAVI) with a balloon-expandable device in Italy. METHODS: The Italian Transcatheter balloon-Expandable valve Registry (ITER) is a real-world registry that includes patients who have undergone TAVI with the Sapien (Edwards Lifesciences, Irvine, CA, USA) bioprosthesis in Italy since it became available in clinical practice. From 2007 to 2012, 1904 patients were enrolled to undergo TAVI in 33 Italian centres. Outcomes were classified according to the updated Valve Academic Research Consortium (VARC-2) definitions. A multivariable analysis was performed to identify independent predictors of all-cause mortality. RESULTS: Mean age was 81.7 (SD:6.2) years, and 1147 (60.2%) patients were female. Mean Logistic EuroSCORE was 21.1% (SD:13.7). Transfemoral, transapical, transaortic and transaxillary TAVI was performed in 1252 (65.8%), 630 (33.1%), 18 (0.9%) and 4 (0.2%) patients, respectively. Operative mortality was 7.2% (137 patients). The VARC-2 outcomes were as follows: device success, 88.1%; disabling stroke, 1.0%; life-threatening and major bleeding 9.8 and 10.5%, respectively; major vascular complication, 9.7%; acute kidney injury, 8.2%; acute myocardial infarction ≤72 h, 1.5%. Perioperative pacemaker implantation was necessary in 116 (6.1%) patients. At discharge, the mean transprosthetic gradient was 10.7 (SD:4.5) mmHg. Incidence of postoperative mild, moderate or severe paravalvular leak was, respectively, 32.1, 5.0 and 0.4%. A total of 444/1767 (25.1%) deaths after hospital discharge were reported: of these, 168 (37.8%) were classified as cardiac death. Preoperative independent predictors of all-cause mortality were male gender (HR: 1.395; 95% CI:1.052-1.849); overweight, BMI 25-30 kg/m2 (HR: 0.775; 95% CI: 0.616-0.974); serum creatinine level (every 1 mg/dl increase; HR: 1.314; 95% CI:1.167-1.480); haemoglobin level (every 1 g/dl increase; HR: 0.905; 95% CI:0.833-0.984); critical preoperative state (HR: 2.282; 95% CI: 1.384-3.761); neurological dysfunction (HR: 1.552; 95% CI:1.060-2.272); atrial fibrillation (HR: 1.556; 95% CI:1.213-1.995); pacemaker rhythm (HR: 1.948; 95% CI:1.310-2.896); NYHA Class III or IV (HR: 1.800; 95% CI:1.205-2.689 or HR: 2.331; 95% CI:1.392-3.903, respectively). CONCLUSIONS: TAVI with a balloon-expandable device in the 'real world' shows good mid-term outcomes in terms of survival, technical success, valve-related adverse events and haemodynamic performance.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Itália , Masculino , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
15.
Ital Heart J ; 6(7): 603-7, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16274025

RESUMO

Valsalva sinus aneurysms are usually congenital and relatively rare and tend to be more frequent in adults. Rupture of these aneurysms can result in sudden death or in an abrupt and rapid progressive heart failure. Surgical repair is the traditional treatment of choice. We report the case of a 48-year-old female with a ruptured posterior non-coronary Valsalva sinus aneurysm, resulting in an anomalous aorto-right atrial fistula. Successful percutaneous catheter closure of the massive left-to-right shunt by using the Amplatzer duct occluder is presented.


Assuntos
Aneurisma Aórtico/complicações , Aneurisma Aórtico/terapia , Ruptura Aórtica/complicações , Ruptura Aórtica/terapia , Cateterismo Cardíaco , Átrios do Coração , Insuficiência Cardíaca/etiologia , Seio Aórtico , Cateterismo Cardíaco/instrumentação , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade
18.
G Ital Cardiol (Rome) ; 16(10): 578-81, 2015 Oct.
Artigo em Italiano | MEDLINE | ID: mdl-26444217

RESUMO

The radial artery approach has been accepted as an alternative to the traditional femoral approach in both diagnostic and interventional procedures, including treatment of complex coronary lesions such as chronic total occlusions. Catheterization of the left internal mammary artery (LIMA) graft is frequently performed through this route in order to limit catheter manipulation and avoid dissection of the subclavian and mammary artery, a dramatic event rarely reported in the literature. Nonetheless, indication for this approach should be carefully evaluated, especially if an unfavorable angle of origin of the mammary artery is present. We report the case of a patient who, following iatrogenic dissection of the LIMA during catheterization through the left radial artery, was electively treated with percutaneous coronary angioplasty on a complex anatomy, rather than with high-risk redo coronary artery bypass surgery. Using a combined radial and femoral approach, retrograde disobstruction of the left anterior descending artery, followed by plaque debulking with rotational atherectomy through the struts of a previously implanted stent in the left main-left circumflex artery, was performed. Although the radial approach might be considered even for the treatment of complex coronary anatomy subsets, appropriate use in diagnostic and interventional settings should always be carefully evaluated.


Assuntos
Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Artéria Radial , Dissecação , Humanos , Masculino , Artéria Torácica Interna/lesões , Pessoa de Meia-Idade
20.
Interv Cardiol Clin ; 2(1): 51-84, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28581988

RESUMO

Patent foramen ovale (PFO) is considered a risk factor for serious clinical syndromes, the most important of which is cryptogenic stroke in the setting of paradoxic embolism. The safety and feasibility of transcatheter PFO closure have been addressed in several studies; this procedure is performed worldwide with excellent results. Variations in the atrial septal configuration and PFO are frequent and have an impact on the technical aspects and success in transcatheter PFO closure. To minimize the rate of complications of percutaneous closure of PFO, patients must be carefully selected on the basis of morphology and location of the interatrial defect.

SELEÇÃO DE REFERÊNCIAS