Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Immunol ; 242: 109091, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35944880

RESUMO

BACKGROUND: The soluble urokinase Plasminogen Activator Receptor (suPAR) has been identified as a reliable marker of COVID-19 severity, helping in personalizing COVID-19 therapy. This study aims to evaluate the correlation between suPAR levels and COVID-19 severity, in relation to the traditional inflammatory markers. METHODS: Sera from 71 COVID-19 patients were tested for suPAR levels using Chorus suPAR assay (Diesse Diagnostica Senese SpA, Italy). suPAR levels were compared with other inflammatory markers: IL-1ß, IL-6, TNF-α, circulating calprotectin, neutrophil and lymphocyte counts, and Neutrophil/Lymphocytes Ratio (NLR). Respiratory failure, expressed as P/F ratio, and mortality rate were used as indicators of disease severity. RESULTS: A positive correlation of suPAR levels with IL-6 (r = 0.479, p = 0.000), TNF-α (r = 0.348, p = 0.003), circulating calprotectin (r = 0.369, p = 0.002), neutrophil counts (r = 0.447, p = 0.001), NLR (r = 0.492, p = 0.001) has been shown. Stratifying COVID-19 population by suPAR concentration above and below 6 ng/mL, we observed higher levels of circulating calprotectin (10.1 µg/mL, SD 7.9 versus 6.4 µg/mL, SD 7.5, p < 0.001), higher levels of P/F ratio (207.5 IQR 188.3 vs 312.0 IQR 127.8, p = 0.013) and higher mortality rate. Median levels of suPAR were increased in all COVID-19 patients requiring additional respiratory support (Nasal Cannula, Venturi Mask, BPAP and CPAP) (6.5 IQR = 4.9) compared to the group at room air (4.6 IQR = 4.2). CONCLUSION: suPAR levels correlate with disease severity and survival rate of COVID-19 patients, representing a promising prognostic biomarker for the risk assessment of the disease.


Assuntos
COVID-19 , Receptores de Ativador de Plasminogênio Tipo Uroquinase , Biomarcadores , Humanos , Interleucina-6 , Complexo Antígeno L1 Leucocitário , Prognóstico , Receptores de Ativador de Plasminogênio Tipo Uroquinase/metabolismo , Fator de Necrose Tumoral alfa
2.
Clin Chem Lab Med ; 60(6): 934-940, 2022 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-35303766

RESUMO

OBJECTIVES: Evaluating anti-SARS-CoV-2 antibody levels is a current priority to drive immunization, as well as to predict when a vaccine booster dose may be required and for which priority groups. The aim of our study was to investigate the kinetics of anti-SARS-CoV-2 Spike S1 protein IgG (anti-S1 IgG) antibodies and neutralizing antibodies (NAbs) in an Italian cohort of healthcare workers (HCWs), following the Pfizer/BNT162b2 mRNA vaccine, over a period of up to six months after the second dose. METHODS: We enrolled 57 HCWs, without clinical history of COVID-19 infection. Fluoroenzyme-immunoassay was used for the quantitative anti-S1 IgG antibodies at different time points T1 (one month), T3 (three months) and T6 (six months) following the second vaccine shot. Simultaneously, a commercial surrogate virus neutralization test (sVNT) was used for the determination of NAbs, expressed as inhibition percentage (% IH). RESULTS: Median values of anti-S1 IgG antibodies decreased from T1 (1,452 BAU/mL) to T6 (104 BAU/mL) with a percent variation of 92.8% while the sVNT showed a percent variation of 34.3% for the same time frame. The decline in anti-S1 IgG antibodies from T1 to T6 was not accompanied by a loss of the neutralizing capacity of antibodies. In fact at T6 a neutralization percentage <20% IH was observed only in 3.51% of HCWs. CONCLUSIONS: Our findings reveal that the decrease of anti-S1 IgG levels do not correspond in parallel to a decrease of NAbs over time, which highlights the necessity of using both assays to assess vaccination effectiveness.


Assuntos
Anticorpos Neutralizantes , COVID-19 , Anticorpos Antivirais , Vacina BNT162 , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Pessoal de Saúde , Humanos , Imunoglobulina G , SARS-CoV-2 , Testes Sorológicos , Vacinas Sintéticas , Vacinas de mRNA
3.
Int J Mol Sci ; 23(20)2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-36293190

RESUMO

The vulnerable population of kidney transplant recipients (KTRs) are low responders to COVID-19 vaccines, so specific immune surveillance is needed. The interferon-gamma (IFN-γ) release assay (IGRA) is effective in assessing T cell-mediated immunity. We assessed SARS-CoV-2-directed T cell responses in KTRs with absent antibody production after a third dose of the mRNA-1273 vaccine, using two different IGRAs. A cohort of 57 KTRs, who were actively followed up, received a third dose of the mRNA-1273 vaccine. After the evaluation of humoral immunity to SARS-CoV-2, 14 seronegative patients were tested with two commercial IGRAs (SD Biosensor and Euroimmun). Out of 14 patients, one and three samples were positive by IGRAs with Euroimmun and SD Biosensor, respectively. The overall agreement between the two assays was 85.7% (κ = 0.444). In addition, multivariate linear regression analysis showed no statistically significant association between the IFN-γ concentration, and the independent variables analyzed (age, gender, years since transplant, total lymphocytes cells/mcl, CD3+ cells/mcl, CD3+ CD4+ cells/mcl, CD3+ CD8+ cells/mcl, CD19+ cells/mcl, CD3-CD16+CD56+ cells/mcl) (p > 0.01). In a vulnerable setting, assessing cellular immune response to complement the humoral response may be advantageous. Since the two commercial IGRAs showed a good agreement on negative samples, the three discordant samples highlight the need for further investigations.


Assuntos
COVID-19 , Transplante de Rim , Humanos , Vacina de mRNA-1273 contra 2019-nCoV , Interferon gama/análise , Linfócitos T/química , Vacinas contra COVID-19 , Formação de Anticorpos , SARS-CoV-2 , COVID-19/prevenção & controle , Transplantados , Anticorpos Antivirais
4.
Genome Res ; 27(7): 1220-1229, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28588068

RESUMO

Chlamydia trachomatis is the world's most prevalent bacterial sexually transmitted infection and leading infectious cause of blindness, yet it is one of the least understood human pathogens, in part due to the difficulties of in vitro culturing and the lack of available tools for genetic manipulation. Genome sequencing has reinvigorated this field, shedding light on the contemporary history of this pathogen. Here, we analyze 563 full genomes, 455 of which are novel, to show that the history of the species comprises two phases, and conclude that the currently circulating lineages are the result of evolution in different genomic ecotypes. Temporal analysis indicates these lineages have recently expanded in the space of thousands of years, rather than the millions of years as previously thought, a finding that dramatically changes our understanding of this pathogen's history. Finally, at a time when almost every pathogen is becoming increasingly resistant to antimicrobials, we show that there is no evidence of circulating genomic resistance in C. trachomatis.


Assuntos
Chlamydia trachomatis/genética , Farmacorresistência Bacteriana/genética , Ecótipo , Evolução Molecular , Genoma Bacteriano , Chlamydia trachomatis/isolamento & purificação , Feminino , Humanos , Masculino
5.
J Med Virol ; 92(9): 1671-1675, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32330291

RESUMO

A pandemic of coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been spreading throughout the world. Though molecular diagnostic tests are the gold standard for COVID-19, serological testing is emerging as a potential surveillance tool, in addition to its complementary role in COVID-19 diagnostics. Indubitably quantitative serological testing provides greater advantages than qualitative tests but today there is still little known about serological diagnostics and what the most appropriate role quantitative tests might play. Sixty-one COVID-19 patients and 64 patients from a control group were tested by iFlash1800 CLIA analyzer for anti-SARS CoV-2 antibodies IgM and IgG. All COVID-19 patients were hospitalized in San Giovanni di Dio Hospital (Florence, Italy) and had a positive oro/nasopharyngeal swab reverse-transcription polymerase chain reaction result. The highest sensitivity with a very good specificity performance was reached at a cutoff value of 10.0 AU/mL for IgM and of 7.1 for IgG antibodies, hence near to the manufacturer's cutoff values of 10 AU/mL for both isotypes. The receiver operating characteristic curves showed area under the curve values of 0.918 and 0.980 for anti-SARS CoV-2 antibodies IgM and IgG, respectively. iFlash1800 CLIA analyzer has shown highly accurate results for the anti-SARS-CoV-2 antibodies profile and can be considered an excellent tool for COVID-19 diagnostics.


Assuntos
Anticorpos Antivirais/imunologia , COVID-19/diagnóstico , COVID-19/imunologia , Imunoensaio , Imunoglobulina G/imunologia , Imunoglobulina M/imunologia , Medições Luminescentes , SARS-CoV-2/imunologia , Idoso , Idoso de 80 Anos ou mais , Anticorpos Antivirais/sangue , Automação Laboratorial , COVID-19/virologia , Feminino , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Medições Luminescentes/métodos , Medições Luminescentes/normas , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
New Microbiol ; 38(2): 245-50, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25938749

RESUMO

Microbial identification from blood cultures is essential to institute optimal antibiotic therapy and improve survival possibilities. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been successfully applied to identify bacteria and yeasts from positive blood cultures broths. The aim of this multicentre study was to evaluate the reliability of the lysis-filtration technique associated with MALDI-TOF MS to directly identify microorganisms from 765 positive blood cultures collected in six Italian hospitals. Overall, 675/765 (78.1%) blood isolates were correctly identified at the species level, with significant differences between Gram-negative and Gram-positive bacteria (92.6%, and 69.8%, respectively). Some difficulties arise in identifying Streptococcus pneumoniae, Staphylococcus aureus, yeasts and anaerobes. The lysis-filtration protocol is a suitable procedure in terms of performance in identifying microorganisms, but it is quite expensive and technically time-consuming since the time of filtration is not regular for all the samples. The application of the MALDI-TOF MS technique to the direct microbial identification from positive blood cultures is a very promising approach, even if more experience must be gained to minimize errors and costs.


Assuntos
Bactérias/isolamento & purificação , Infecções Bacterianas/microbiologia , Técnicas de Tipagem Bacteriana/métodos , Sangue/microbiologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bactérias/química , Bactérias/classificação , Infecções Bacterianas/sangue , Humanos
9.
Int Immunopharmacol ; 122: 110460, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37392566

RESUMO

BACKGROUND AND PURPOSE: Data on immunoresponse after SARS-CoV-2 vaccines for patients treated with exclusive radiotherapy (RT) are scarce. Since RT may affect the immune system, we conducted the MORA trial (Antibody response and cell-mediated immunity of MOderna mRNA-1273 vaccine in patients treated with RAdiotherapy). MATERIALS AND METHODS: Data regarding humoral and cellular immune response of patients treated with RT were prospectively collected after the second and third dose of mRNA vaccines. RESULTS: Ninety-two patients were enrolled. With a median of 147 days after the second dose, the median SARS-CoV-2 IgG titer was 300 BAU/mL: six patients were seronegative (Spike IgG titer ≤ 40 BAU/mL), whereas 24, 46 and 16 were poor responders (Spike IgG titer:41-200 BAU/mL), responders (Spike IgG titer:201-800 BAU/mL) and ultraresponders (Spike IgG titer > 800 BAU/mL), respectively. Among seronegative patients, two patients were negative also for cell mediated response, as tested with IFN-γ release Assay (IGRA) test. With a median of 85 days after the third dose, the median SARS-CoV-2 IgG titer was 1632 BAU/mL in 81 patients: only two patients were seronegative, whereas 16 and 63 patients were responders and ultraresponders, respectively. Among the 2 persistently seronegative patients, IGRA test was negative in one who had previously received anti-CD20 therapy. Documented paucisymptomatic (n = 3) or asymptomatic (n = 4) infection occurred after the third dose, during the Omicron wave. CONCLUSION: In patients treated with exclusive RT, even during the Omicron breakthrough, robust humoral response and clinical protection from severe SARS-CoV-2 disease were achievable with three doses of mRNA vaccine.


Assuntos
COVID-19 , Neoplasias , Humanos , Vacina de mRNA-1273 contra 2019-nCoV , Vacinas contra COVID-19/uso terapêutico , COVID-19/prevenção & controle , SARS-CoV-2 , Vacinas de mRNA , Neoplasias/radioterapia , Anticorpos Antivirais , Imunoglobulina G
10.
Front Biosci (Landmark Ed) ; 27(2): 74, 2022 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-35227017

RESUMO

BACKGROUND: Several commercial surrogate Virus Neutralization Tests (sVNTs) have been developed in the last year. Neutralizing anti-SARS-CoV-2 antibodies through interaction with Spike protein Receptor Binding Domain (S-RBD) can block the virus from entering and infecting host cells. However, there is a lack of information about the functional activity of SARS-CoV-2 antibodies that may be associated with protective responses. For these reasons, to counteract viral infection, the conventional virus neutralization test (VNT) is still considered the gold standard. The aim of this study was to contribute more and detailed information about sVNTs' performance, by determining in vitro the anti-SARS-CoV-2 neutralizing antibody concentration using four different commercial assays and then comparing the obtained data to VNT. METHODS: Eighty-eight samples were tested using two chemiluminescence assays (Snibe and Mindray) and two ELISA assays (Euroimmun and Diesse). The antibody titers were subsequently detected and quantified by VNT. RESULTS: The overall agreement between each sVNT and VNT was 95.45% for Euroimmun and 98.86% for Diesse, Mindray and Snibe. Additionally, we investigated whether the sVNTs were closer to the gold standard than traditional anti-SARS-CoV-2 antibody assays S-RBD or S1 based, finding a higher agreement mean value for sVNTs (98.01 ± 1.705% vs 95.45 ± 1.921%; p < 0.05). Furthermore, Spearman's statistical analysis for the correlation of sVNT versus VNT showed r = 0.666 for Mindray; r = 0.696 for Diesse; r = 0.779 for Mindray and r = 0.810 for Euroimmun. CONCLUSIONS: Our data revealed a good agreement between VNT and sVNTs. Despite the VNT still remains the gold standard, the sVNT might be a valuable tool for screening wider populations.


Assuntos
Anticorpos Neutralizantes , COVID-19 , Anticorpos Antivirais , COVID-19/diagnóstico , Humanos , Testes de Neutralização , SARS-CoV-2
11.
Int Immunopharmacol ; 100: 108095, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34619529

RESUMO

BACKGROUND AND AIMS: SARS-CoV-2 antibody assays are relevant in managing the COVID-19 pandemic, providing valuable data on the immunization status of the population. However, current serology tests are highly variable, due to their different characteristics and to the lack of reference materials. The aim of the World Health Organization (WHO) first International Standard (IS) for anti-SARS-CoV-2 immunoglobulin is to harmonize humoral immune response assessment after natural infection or vaccination, and recommend reporting the results for binding activity in Binding Antibody Units (BAU). MATERIALS AND METHODS: This study analyzed six commercial quantitative anti-SARS-CoV-2 S-protein assays in a head-to-head comparison, using the manufacturers' conversion factors for the WHO IS to obtain BAU/mL values. RESULTS: Our data showed good alignment up to 1000 BAU/mL, then began to disperse, exhibiting some discrepancies. Moreover, correlations among methods varied with Cohen's Kappa ranging from 0.580 to 1.00, with the lowest agreement values for kits using different target antigens or different antibody isotypes, making it clear that the laboratory report should include this information. Values expressed as BAU/ml showed a reduced between-assays variability compared to AU/ml (median coefficients of variation 0.38 and 0.68, respectively; p < 0.001). CONCLUSION: On the basis of these data at present anti-SARS CoV-2 serological assays' results are not interchangeable, and, more importantly, individual immune monitoring should be performed with the same method.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/normas , COVID-19/diagnóstico , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Adulto , Idoso , Feminino , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Organização Mundial da Saúde
12.
Immunol Res ; 66(1): 74-78, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29159696

RESUMO

Immunofluorescence on HEp2-cells is the standard diagnostic assay for the detection of anti-nuclear antibodies (ANA). Cytoplasmic speckled patterns are a common finding, and are associated with various antibodies, including anti-synthetase antibodies. However, classic ENA testing generally identifies only anti-Jo-1. Moreover, anti-synthetase syndrome is increasingly recognized as a pleomorphic entity, possibly presenting as isolated arthritis or interstitial lung disease. Sera referred for routine ANA testing were selected on the basis of the presence of a fine dense speckled cytoplasmic pattern (254 samples) and compared to control sera with negative cytoplasm (239 samples). All 493 samples were tested with a commercial synthetase profile dot-blot (D TEK - Alphadia-Alifax) including anti-Jo1, anti-PL7, anti-PL12, anti-EJ, anti-OJ, anti-KS, anti-ZO, anti-HA, anti-SRP, and anti-Ribosome P0. Retrospective clinical data was searched for positive patients. Dot-blot identified 18/254 (7.1%) positive sera in the samples with a cytoplasmic fluorescence pattern and 4/239 (1.7%) in the control group (χ2 = 8.4627; p = 0.003625). Blot intensity was more intense in samples with concordant cytoplasmic staining (cytoplasmic negative 27 ± 12.4; cytoplasmic positive 53.9 27 ± 27.7; p = 0.0027). In the positive samples, 8/18 had a highly compatible diagnosis (myositis, interstitial lung disease, arthritis), 7/18 an uncharacterized connective tissue disease, and 3 a diagnosis not associated with the presence of anti-synthetase antibodies. We evaluated the performance of a dot-blot assay for anti-cytoplasmic antibodies in a serologic cohort presenting a cytoplasmic speckled pattern found during routine ANA testing. This algorithm enabled the identification of a significant quota of patients with rare anti-synthetase antibodies and an incomplete or atypical clinical picture. Reflex testing strategies of speckled cytoplasmic patterns with multiplex assays containing cytoplasm-specific antigens, as opposed to standard ENA testing, may yield important data and for this reason should be implemented in routine ANA testing.


Assuntos
Anticorpos Antinucleares/metabolismo , Doenças Autoimunes/imunologia , Citoplasma/metabolismo , Artrite , Autoantígenos/imunologia , Doenças Autoimunes/diagnóstico , Estudos de Coortes , Testes Diagnósticos de Rotina , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Immunoblotting , Ligases/imunologia , Doenças Pulmonares Intersticiais , Miosite , Estudos Retrospectivos , Síndrome
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA